993 resultados para Autogenous shrinkage


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ongoing use of various mineral additions along with chemical admixtures such as superplasticizers justifies the need for further research. Understanding and quantifying their effects and possible synergies on the fresh and hardened properties of cement-based materials is necessary, especially if some of these components are known to have a pozzolanic effect. This paper describes and models the fresh and hardened properties of cement mortars including nanosilica and fly ash, and relates their properties to the proportioning of these materials and the superplasticizer dosage. Mini-slump, Marsh cone and Lombardi cone tests were used to examine the properties of the fresh mortars, and to assess density, plastic shrinkage, and drying shrinkage up to 20 days. The equations presented in this paper make it possible to optimize mortar proportionings to the required levels of performance in both fresh and hardened states.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work project regards a challenge presented by a Portuguese organization on the retail sector, SONAEMC, which is a case study of how and why fruit shrinkage occurs in the fruit supply chain within their convenience stores. A qualitative research methodology enabled to infer in which stages throughout the chain shrinkage’s causes occur and, to conclude that internal rules for procedures and processes are not always followed and whose compliance would be enough to reduce fruit shrinkage. The key conclusion is that if fruit stock loss is reduced by as much as 15% the category’s profitability could increase about 8%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper examines changes in the surface area of glaciers in the North and South Chuya Ridges, Altai Mountains in 1952-2004 and their links with regional climatic variations. The glacier surface areas for 2004 were derived from the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) imagery. Data from the World Glacier Inventory (WGI)dating to 1952 and aerial photographs from 1952 were used to estimate the changes. 256 glaciers with a combined area of 253±5.1 km2 have been identified in the region in 2004. Estimation of changes in extent of 126 glaciers with the individual areas not less than 0.5 km2 in 1952 revealed a 19.7±5.8% reduction. The observed glacier retreat is primarily driven by an increase in summer temperatures since the 1980s when air temperatures were increasing at a rate of 0.10 - 0.13oC a-1 at the glacier tongue elevation. The regional climate projections for A2 and B2 CO2 emission scenarios developed using PRECIS regional climate model indicate that summer temperatures will increase in the Altai in 2071-2100 by 6-7oC and 3-5oC respectively in comparison with 1961-1990 while annual precipitation will increase by 15% and 5%. The length of the ablation season will extend from June-August to the late April – early October. The projected increases in precipitation will not compensate for the projected warming and glaciers will continue to retreat in the 21st century under both B2 and A2 scenarios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We used Little Ice Age (LIA) trimlines and moraines to assess changes in South American glaciers over the last ∼140 years. We determined the extent and length of 640 glaciers during the LIA (∼ AD 1870) and 626 glaciers (the remainder having entirely disappeared) in 1986, 2001 and 2011. The calculated reduction in glacierized area between the LIA and 2011 is 4131 km2 (15.4%), with 660 km2 (14.2%) being lost from the Northern Patagonia Icefield (NPI), 1643 km2 (11.4%) from the Southern Patagonia Icefield (SPI) and 306 km2 (14.4%) from Cordillera Darwin. Latitude, size and terminal environment (calving or land-terminating) exert the greatest control on rates of shrinkage. Small, northerly, land-terminating glaciers shrank fastest. Annual rates of area loss increased dramatically after 2001 for mountain glaciers north of 52° S and the large icefields, with the NPI and SPI now shrinking at 9.4 km2 a–1 (0.23% a–1) and 20.5 km2 a–1 (0.15% a–1) respectively. The shrinkage of glaciers between 52° S and 54° S accelerated after 1986, and rates of shrinkage from 1986 to 2011 remained steady. Icefield outlet glaciers, isolated glaciers and ice caps south of 54° S shrank faster from 1986 to 2001 than they did from 2001 to 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of the present study was to investigate the healing, integration, and maintenance of autogenous onlay bone grafts and implant osseointegration either loaded in the early or the delayed stages. Materials and Methods: A total of 5 male clogs received bilateral blocks of onlay bone grafts harvested from the contralateral alveolar ridge of the mandible. On one side, the bone block was secured by 3 dental implants (3.5 mm x 13.0 mm, Osseospeed; Astra Tech AB, Molndal, Sweden). Two implants at the extremities of the graft were loaded 2 clays after installation by abutment connection and prosthesis (simultaneous implant placement group); the implant in the middle remained unloaded and served as the control. On the other side, the block was fixed with 2 fixation screws inserted in the extremities of the graft. Four weeks later, the fixation screws were replaced with 3 dental implants. The loading procedure (delayed implant placement group) was performed 2 clays later, as described for the simultaneous implant placement sites. The animals were sacrificed 12 weeks after the grafting procedure. Implant stability was measured through resonance frequency analysis. The bone volume and density were assessed on computed tomography. The bone to implant contact and bone area in a region of interest were evaluated on histologic slides. Results: The implant stability quotient showed statistical significance in favor of the delayed loaded grafts (P=.001). The bone-to-implant contact (P=.008) and bone area in a region of interest (P=0.005) were significantly greater in the delayed group. Nevertheless, no difference was found in terms of graft volume and density between the early loaded and delayed-loaded approaches. Conclusions: The protocol in which the implant and bone graft were given delayed loading allows for effective quality of implant osseointegration and stabilization, with healing and remodeling occurring in areas near the implant resulting in denser bone architecture. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Sing 68:825-832, 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the influence of different light sources and photo-activation methods on degree of conversion (DC%) and polymerization shrinkage (PS) of a nanocomposite resin (Filtek (TM) Supreme XT, 3M/ESPE). Two light-curing units (LCUs), one halogen-lamp (QTH) and one light-emitting-diode (LED), and two different photo-activation methods (continuous and gradual) were investigated in this study. The specimens were divided in four groups: group 1-power density (PD) of 570 mW/cm(2) for 20 s (QTH); group 2-PD 0 at 570 mW/cm(2) for 10 s + 10 s at 570 mW/cm(2) (QTH); group 3-PD 860 mW/cm(2) for 20 s (LED), and group 4-PD 125 mW/cm(2) for 10 s + 10 s at 860 mW/cm(2) (LED). A testing machine EMIC with rectangular steel bases (6 x 1 x 2 mm) was used to record the polymerization shrinkage forces (MPa) for a period that started with the photo-activation and ended after two minutes of measurement. For each group, ten repetitions (n = 40) were performed. For DC% measurements, five specimens (n = 20) for each group were made in a metallic mold (2 mm thickness and 4 mm diameter, ISO 4049) and them pulverized, pressed with bromide potassium (KBr) and analyzed with FT-IR spectroscopy. The data of PS were analyzed by Analysis of Variance (ANOVA) with Welch`s correction and Tamhane`s test. The PS means (MPa) were: 0.60 (G1); 0.47 (G2); 0.52 (G3) and 0.45 (G4), showing significant differences between two photo-activation methods, regardless of the light source used. The continuous method provided the highest values for PS. The data of DC% were analyzed by Analysis of Variance (ANOVA) and shows significant differences for QTH LCUs, regardless of the photo-activation method used. The QTH provided the lowest values for DC%. The gradual method provides lower polymerization contraction, either with halogen lamp or LED. Degree of conversion (%) for continuous or gradual photo-activation method was influenced by the LCUs. Thus, the presented results suggest that gradual method photo-activation with LED LCU would suffice to ensure adequate degree of conversion and minimum polymerization shrinkage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the shrinkage of a microhybrid dental composite resin photo-activated by one LED with different power densities by means of speckle technique. The dental composite resin Filtek (TM) Z-250 (3M/ESPE) at color A(2) was used for the samples preparation. Uncured composite was packed in a metallic mold and irradiated during 20 s from 100 to 1000 mW cm(-2). For the photo-activation of the samples, it was used a LED prototype (Light Emission Diode) with wavelength centered at 470 nm and adjustable power density until 1 W cm(-2). The speckle patterns obtained from the bottom composite surfaces were monitored using a CCD camera without lens. The speckle field is recorded in a digital picture and stored by CCD camera as the carrier of information on the displacement of the tested surface. The calculated values were obtained for each pair of adjacent patterns and the changes in speckle contrast as a function of time were obtained from six repeated measurements. The speckle contrasts obtained from the bottom surface with 100 mW cm(-1) were smaller than those than the other power densities. The higher power densities provided the higher shrinkage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The standard tests for relaxation shrinkage and hygral expansion of wool fabric take no account of pH. It is shown in this work that the pH of the solution in which wool fabric is relaxed as part of the procedure for measuring dimensional properties has a significant influence on the results. At around pH 4.8, which is close to the isoelectric point of wool, the hygral expansion reaches its greatest value and drops at both lower and higher pHs. A similar relationship between pH and extensibility of wool fabric was observed. Values of relaxation shrinkage were found to be dependant on pH. The reasons for the pH dependence of dimensional properties are discussed and these include changes in wool fiber swelling, yarn crimp and polymer relaxation phenomena with changes in pH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel thermo-mechanical shrinking method is reported to fabricate a three dimensional (3D) stretchable and highly conductive micro-wrinkled reduced graphene oxide (MWrGO) supported on an elastic polydimethylsiloxane (PDMS) substrates. This 3D rGO architecture not only increases the specific area for more electrons to pass through but also bestows stretchability to the conductive pathway. The structural change of micro-wrinkles has been monitored by an in situ straining microscopy. The electrical conductivity of the samples remained fairly constant and stayed above 25 S/m under low deformation (no more than 30% strain) for up to 500 mechanical stretching-release cycles. Additionally, the MWrGO/PDMS composite can be stretched bi-axially because the shrinking process itself is isotropic. This MWrGO based stretchable composite with stable electrical properties and long life span could form a new platform of stretchable electronics.