958 resultados para Anatomic diameter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the results of an anatomic open stabilization procedure. Twenty-three consecutive patients with traumatic, recurrent, anterior glenohumeral instability were managed with a modified open procedure. All had a Bankart lesion. A standardized, true anatomic capsulolabral reconstruction was performed with suture anchors. Two patients were lost to follow-up, and twenty-one were evaluated after 36 months [range, 24-49 months] by an independent observer. Shoulder stability and function were the principal outcome measures. None of the patients had subsequent dislocations. All returned to full working capacity, and 19 reached their previous level of sport activities. The mean loss in active abduction and flexion was 1 degrees, in internal rotation, one vertebral level, and in external rotation, 7 degrees (arm at 90 degrees of abduction). Two patients had a positive anterior apprehension test. No sign of shoulder osteoarthritis was observed. The open anatomic capsulolabral reconstruction provides excellent results and allows the restoration of stability with good function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate whether peroperative perfluorocarbon liquids (PFCL) improve the long term anatomical success of retinal detachment associated with severe proliferative vitreoretinopathy (PVR). PATIENTS AND METHODS: The charts of 62 successive patients operated on for retinal detachment associated with severe PVR were retrospectively analyzed. For one group of 39 patients PFCL were used intraoperatively to improve membrane dissection. The anatomical status of the two groups were compared one month after surgery and at least 6 months after silicone oil ablation. RESULTS: Anatomical success was observed in 84.6% in the group of patients operated with PFCL compared to 52% in the other group (P = 0.005). At the end of the follow up, anatomical success was observed in 64% of patients operated with PFCL compared to 61% in the control group (P = 0.8). However, recurrences were observed later in the group operated on with PFCL. CONCLUSION: Perfluorocarbons liquids significantly improve the initial reattachment of retinal detachment complicated with severe PVR, but they do not seem to improve their final anatomical status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intracranial hypertension is an emergency suspected from clinical symptoms, imaging data and ophthalomologic signs. Intracranial hypertension is confirmed by invasive intracranial monitoring, which is the gold standard technique to measure intracranial pressure (ICP). Because of complications, hemorrhage or infection, non-invasive methods have been developed such as neuroimaging, transcranial Doppler sonography and optic nerve sheath diameter (ONSD) ultrasonography. We have reviewed ONSD technique that detects intracranial hypertension related volume variations of subarachnoid space along the retro bulbar segment of the optic nerve. Technique, indications and prospects are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Polyethylene wear is a recurrent problem in joint arthroplasty. Small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. The goal of this study was thus to estimate the volume of polyethylene wear of a reversed prosthesis, and compare it to an anatomic prosthesis, during one year of activities of daily living. Material and Methods: A numerical musculoskeletal model of the glenohumeral joint was used for this comparative study. The reversed (RP) and anatomic (AP) Aequalis prostheses were positioned in the numerical model. Eight levels of abduction were considered. Their daily frequency was estimated from in-vivo recorded data on healthy volunteers during activities of daily living. One year of use was simulated to predict the linear and volumetric wear. The volumetric wear was the difference of volume between the original and worn component. Results: With the AP, the contact pattern on the glenoid surface moved rapidly from the inferior to the superior side during the first 30 degrees of abduction, and then went back to the inferior side. With the RP, the contact pattern on the humeral cup surface remained at the inferior side. Contact pressure was 20 times lower with the RP than with the AP. One year of use produced a maximum linear wear of 0.2 mm with the AP, and 0.13 mm with the RP. However, the volumetric wear was 8.4 mm3 with the AP, but reached 44.6 mm3 with the RP. Conclusion: Polyethylene particles are a matter of concern with AP. Infiltration of these particles within the bone-implant interface can induce a implant loosening. This problem should not be underestimated with RP. It might be associated to a higher level of humeral stem loosening reported with RP. The long term survival of RP might be improved by using a highly cross-linked polyethylene, which has a better abrasion resistance but lower plastic resistance.