899 resultados para (Gas-liquid) partition coefficients


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Stratum corneum (SC) desorption experiments have yielded higher calculated steady-state fluxes than those obtained by epidermal penetration studies. A possible explanation of this result is a variable diffusion or partition coefficient across the SC. We therefore developed the diffusion model for percutaneous penetration and desorption to study the effects of either a variable diffusion coefficient or variable partition coefficient in the SC over the diffusion path length. Steady-state flux, lag time, and mean desorption time were obtained from Laplace domain solutions. Numerical inversion of the Laplace domain solutions was used for simulations of solute concentration-distance and amount penetrated (desorbed)-time profiles. Diffusion and partition coefficients heterogeneity were examined using six different models. The effect of heterogeneity on predicted flux from desorption studies was compared with that obtained in permeation studies. Partition coefficient heterogeneity had a more profound effect on predicted fluxes than diffusion coefficient heterogeneity. Concentration-distance profiles show even larger dependence on heterogeneity, which is consistent with experimental tape-stripping data reported for clobetasol propionate and other solutes. The clobetasol propionate tape-stripping data were most consistent with the partition coefficient decreasing exponentially for half the SC and then becoming a constant for the remaining SC. (C) 2004 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The work is a logical continuation of research started at Aston some years ago when studies were conducted on fermentations in bubble columns. The present work highlights typical design and operating problems that could arise in such systems as waste water, chemical, biochemical and petroleum operations involving three-phase, gas-liquid-solid fluidisation; such systems are in increasing use. It is believed that this is one of few studies concerned with `true' three-phase, gas-liquid-solid fluidised systems, and that this work will contribute significantly to closing some of the gaps in knowledge in this area. The research work was mainly experimentally based and involved studies of the hydrodynamic parameters, phase holdups (gas and solid), particle mixing and segregation, and phase flow dynamics (flow regime and circulation patterns). The studies have focused particularly on the solid behaviour and the influence of properties of solids present on the above parameters in three-phase, gas-liquid-solid fluidised systems containing single particle components and those containing binary and ternary mixtures of particles. All particles were near spherical in shape and two particle sizes and total concentration levels were used. Experiments were carried out in two- and three-dimensional bubble columns. Quantitative results are presented in graphical form and are supported by qualitative results from visual studies which are also shown as schematic diagrams and in photographic form. Gas and solid holdup results are compared for air-water containing single, binary and ternary component particle mixtures. It should be noted that the criteria for selection of the materials used are very important if true three-phase fluidisation is to be achieved: this is very evident when comparing the results with those in the literature. The fluid flow and circulation patterns observed were assessed for validation of the generally accepted patterns, and the author believes that the present work provides more accurate insight into the modelling of liquid circulation in bubble columns. The characteristic bubbly flow at low gas velocity in a two-phase system is suppressed in the three-phase system. The degree of mixing within the system is found to be dependent on flow regime, liquid circulation and the ratio of solid phase physical properties. Evidence of strong `trade-off' of properties is shown; the overall solid holdup is believed to be a major parameter influencing the gas holdup structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The simulation of two-phase flow for an experimental airlift reactor (32-l volume) using commercially available software from Fluent Incorporated is presented here (http://www.fluent.co.uk). Data from the simulation is compared with the experimental data obtained by the tracking of a magnetic particle and analysis of the pressure drop to determine the gas hold-up. Comparisons between vertical velocity and gas hold-up were made for a series of experiments where the superficial gas velocity in the riser was adjusted between 0.01 and 0.075 m s-1. © 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An alternative approach to the modelling of solid-liquid and gas-liquid-solid flows for a 5:1 height to width aspect ratio bubble column is presented here. A modified transport equation for the volume fraction of a dispersed phase has been developed for the investigation of turbulent buoyancy driven flows (Chem. Eng. Proc., in press). In this study, a modified transport equation has been employed for discrete phase motion considering both solid-liquid and gas-liquid-solid flows. The modelling of the three-phase flow in a bubble column was achieved in the following case: injecting a slug of solid particles into the column for 10 s at a velocity of 0.1 m s-1 and then the gas phase flow was initiated with a superficial gas velocity of 0.02 cm s-1. © 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Basic hydrodynamic parameters of an airlift reactor with internal loop were estimated experimentally and simulated using commercially available CFD software from Fluent. Circulation velocity in a 32-dm(3)-airlift reactor was measured using the magnetic tracer method, meanwhile the gas hold-up was obtained by analysis of the pressure drop using the method of inverted U-tube manometers. Comparison of simulated (in two and three dimensions) and experimental data was performed at different superficial gas velocities in the riser.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Peptides are of great therapeutic potential as vaccines and drugs. Knowledge of physicochemical descriptors, including the partition coefficient P (commonly expressed in logarithm form: logP), is useful for screening out unsuitable molecules and also for the development of predictive Quantitative Structure-Activity Relationships (QSARs). In this paper we develop a new approach to the prediction of LogP values for peptides based on an empirical relationship between global molecular properties and measured physical properties. Our method was successful in terms of peptide prediction (total r2 = 0.641). The final model consisted of 5 physicochemical descriptors (molecular weight, number of single bonds, 2D-VDW volume, 2D-VSA hydrophobic and 2D-VSA polar). The approach is peptide specific and its predictive accuracy was high. Overall, 67% of the peptides were able to be predicted within +/-0.5 log units from the experimental values. Our method thus represents a novel prediction method with proven predictive ability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper addresses experiments and modeling studies on the use of producer gas, a bio-derived low energy content fuel in a spark-ignited engine. Producer gas, generated in situ, has thermo-physical properties different from those of fossil fuel(s). Experiments on naturally aspirated and turbo-charged engine operation and subsequent analysis of the cylinder pressure traces reveal significant differences in the heat release pattern within the cylinder compared with a typical fossil fuel. The heat release patterns for gasoline and producer gas compare well in the initial 50% but beyond this, producer gas combustion tends to be sluggish leading to an overall increase in the combustion duration. This is rather unexpected considering that producer gas with nearly 20% hydrogen has higher flame speeds than gasoline. The influence of hydrogen on the initial flame kernel development period and the combustion duration and hence on the overall heat release pattern is addressed. The significant deviations in the heat release profiles between conventional fuels and producer gas necessitates the estimation of producer gas-specific Wiebe coefficients. The experimental heat release profiles are used for estimating the Wiebe coefficients. Experimental evidence of lower fuel conversion efficiency based on the chemical and thermal analysis of the engine exhaust gas is used to arrive at the Wiebe coefficients. The efficiency factor a is found to be 2.4 while the shape factor m is estimated at 0.7 for 2% to 90% burn duration. The standard Wiebe coefficients for conventional fuels and fuel-specific coefficients for producer gas are used in a zero D model to predict the performance of a 6-cylinder gas engine under naturally aspirated and turbo-charged conditions. While simulation results with standard Wiebe coefficients result in excessive deviations from the experimental results, excellent match is observed when producer gas-specific coefficients are used. Predictions using the same coefficients on a 3-cylinder gas engine having different geometry and compression ratio(s) indicate close match with the experimental traces highlighting the versatility of the coefficients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microelectrode voltammetry is used to study the electrochemical reduction of dioxygen, O-2, in the room-temperature ionic liquid trihexyl(tetradecyl)phosphonium trifluorotris(pentafluoroethyl)phosphate [P6,6,6,14][FAP]. The nature of the unusual voltammetric waves is quantitatively modeled via digital simulation with the aim of clarifying apparent inconsistencies in the literature. The reduction is shown to proceed via a two-electron reaction and involve the likely capture of a proton from the solvent system. The oxidative voltammetric signals seen at fast scan rates are interpreted as resulting from the reoxidation of HO2 center dot. In the presence of large amounts of dissolved carbon dioxide the reductive currents decrease by a factor of ca. two, consistent with the trapping of the superoxide radical, O-2(center dot), intermediate in the two-electron reduction process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Os coeficientes de difusão (D 12) são propriedades fundamentais na investigação e na indústria, mas a falta de dados experimentais e a inexistência de equações que os estimem com precisão e confiança em fases comprimidas ou condensadas constituem limitações importantes. Os objetivos principais deste trabalho compreendem: i) a compilação de uma grande base de dados para valores de D 12 de sistemas gasosos, líquidos e supercríticos; ii) o desenvolvimento e validação de novos modelos de coeficientes de difusão a diluição infinita, aplicáveis em amplas gamas de temperatura e densidade, para sistemas contendo componentes muito distintos em termos de polaridade, tamanho e simetria; iii) a montagem e teste de uma instalação experimental para medir coeficientes de difusão em líquidos e fluidos supercríticos. Relativamente à modelação, uma nova expressão para coeficientes de difusão a diluição infinita de esferas rígidas foi desenvolvida e validada usando dados de dinâmica molecular (desvio relativo absoluto médio, AARD = 4.44%) Foram também estudados os coeficientes de difusão binários de sistemas reais. Para tal, foi compilada uma extensa base de dados de difusividades de sistemas reais em gases e solventes densos (622 sistemas binários num total de 9407 pontos experimentais e 358 moléculas) e a mesma foi usada na validação dos novos modelos desenvolvidos nesta tese. Um conjunto de novos modelos foi proposto para o cálculo de coeficientes de difusão a diluição infinita usando diferentes abordagens: i) dois modelos de base molecular com um parâmetro específico para cada sistema, aplicáveis em sistemas gasosos, líquidos e supercríticos, em que natureza do solvente se encontra limitada a apolar ou fracamente polar (AARDs globais na gama 4.26-4.40%); ii) dois modelos de base molecular biparamétricos, aplicáveis em todos os estados físicos, para qualquer tipo de soluto diluído em qualquer solvente (apolar, fracamente polar e polar). Ambos os modelos dão origem a erros globais entre 2.74% e 3.65%; iii) uma correlação com um parâmetro, específica para coeficientes de difusão em dióxido de carbono supercrítico (SC-CO2) e água líquida (AARD = 3.56%); iv) nove correlações empíricas e semi-empíricas que envolvem dois parâmetros, dependentes apenas da temperatura e/ou densidade do solvente e/ou viscosidade do solvente. Estes últimos modelos são muito simples e exibem excelentes resultados (AARDs entre 2.78% e 4.44%) em sistemas líquidos e supercríticos; e v) duas equações preditivas para difusividades de solutos em SC-CO2, em que os erros globais de ambas são inferiores a 6.80%. No global, deve realçar-se o facto de os novos modelos abrangerem a grande variedade de sistemas e moléculas geralmente encontrados. Os resultados obtidos são consistentemente melhores do que os obtidos com os modelos e abordagens encontrados na literatura. No caso das correlações com um ou dois parâmetros, mostrou-se que estes mesmos parâmetros podem ser ajustados usando um conjunto muito pequeno de dados, e posteriormente serem utilizados na previsão de valores de D 12 longe do conjunto original de pontos. Uma nova instalação experimental para medir coeficientes de difusão binários por técnicas cromatográficas foi montada e testada. O equipamento, o procedimento experimental e os cálculos analíticos necessários à obtenção dos valores de D 12 pelo método de abertura do pico cromatográfico, foram avaliados através da medição de difusividades de tolueno e acetona em SC-CO2. Seguidamente, foram medidos coeficientes de difusão de eucaliptol em SC-CO2 nas gamas de 202 – 252 bar e 313.15 – 333.15 K. Os resultados experimentais foram analisados através de correlações e modelos preditivos para D12.