978 resultados para wave pocket method


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sustainable Construction, Materials and Practice, p. 426-432

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show here a simplified RT-PCR for identification of dengue virus types 1 and 2. Five dengue virus strains, isolated from Brazilian patients, and yellow fever vaccine 17DD as a negative control, were used in this study. C6/36 cells were infected and supernatants were collected after 7 days. The RT-PCR, done in a single reaction vessel, was carried out following a 1/10 dilution of virus in distilled water or in a detergent mixture containing Nonidet P40. The 50 µl assay reaction mixture included 50 pmol of specific primers amplifying a 482 base pair sequence for dengue type 1 and 210 base pair sequence for dengue type 2. In other assays, we used dengue virus consensus primers having maximum sequence similarity to the four serotypes, amplifying a 511 base pair sequence. The reaction mixture also contained 0.1 mM of the four deoxynucleoside triphosphates, 7.5 U of reverse transcriptase, 1U of thermostable Taq DNA polymerase. The mixture was incubated for 5 minutes at 37ºC for reverse transcription followed by 30 cycles of two-step PCR amplification (92ºC for 60 seconds, 53ºC for 60 seconds) with slow temperature increment. The PCR products were subjected to 1.7% agarose gel electrophoresis and visualized by UV light after staining with ethidium bromide solution. Low virus titer around 10 3, 6 TCID50/ml was detected by RT-PCR for dengue type 1. Specific DNA amplification was observed with all the Brazilian dengue strains by using dengue virus consensus primers. As compared to other RT-PCRs, this assay is less laborious, done in a shorter time, and has reduced risk of contamination

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No dia-a-dia, os organismos vivos estão sujeitos a vários tipos de agressões de origem endógena e exógena. A produção endógena exagerada de agentes oxidantes que ocorre nos processos metabólicos dos seres vivos está intimamente associada ao aparecimento e desenvolvimento de várias patologias. Por outro lado, e devido às atividades antropogénicas, muitos agentes oxidantes de origem ambiental e alimentar entram por via exógena no organismo dos seres vivos provocando igualmente danos a nível celular. De modo a protegerem-se dos efeitos pejorativos provocados por estes compostos, os organismos vivos desenvolveram mecanismos complexos de defesa antioxidante. Este trabalho consistiu no estudo eletroquímico do dano oxidativo induzido por agentes oxidantes (PAH (hidrocarbonetos aromáticos policíclicos), H2O2, NO• e HClO) e do efeito protetor, ao dano oxidativo, promovido por antioxidantes no material baseado no ADN recorrendo à utilização de um biossensor de bases púricas, adenina-EPC (elétrodo pasta de carbono) e dA20-EPC, utilizando a voltametria de onda quadrada (VOQ) como técnica de deteção. A aplicação da eletroquímica apresenta várias vantagens para a quantificação da capacidade antioxidante total (CAT) pois, permite a redução da quantidade de reagentes e amostra em análise, elimina a etapa de remoção de cor (a cor é um interferente nos métodos óticos) e não requer equipamentos dispendiosos. Foram seguidas diferentes abordagens para a construção dos biossensores. A primeira consistiu na construção de um adenina-EPC em três etapas: i) condicionamento do EPC, ii) eletrodeposição da adenina no EPC e iii) leitura do sinal eletroquímico. Assim, foram otimizados diversos parâmetros: concentração de adenina (150,0 mg/L), potencial de condicionamento (Ec) (+ 1,80 V), potencial de deposição (Ed) (+ 0,40 V), tempo de condicionamento (tc) (180 s) e tempo de deposição (td) (240 s). Foi aplicado o adenina-EPC no estudo do dano oxidativo provocado por PAH (benzo (g,h,i) perileno) e constatou-se que era necessário transformar o benzo (g,h,i) perileno num radical para se possível observar danos oxidativos induzidos no biossensor. A nova estratégia consistiu na construção de um dA20-EPC, através da adsorção física de uma gota de dA20 na superfície do EPC, com posterior secagem e leitura do sinal eletroquímico. Neste procedimento foi otimizada a concentração de dA20 (100,0 mg/L). O dano oxidativo provocado pelo H2O2, NO• e HClO foi estudado sobre o dA20-EPC e verificou-se que os três agentes oxidantes induziam dano oxidativo no dA20-EPC. Confirmou-se a capacidade do ácido ascórbico (AA) em proteger o dA20-EPC do dano oxidativo induzido por H2O2 e NO•. O biossensor desenvolvido (dA20-EPC) foi aplicado na avaliação da CAT de diferentes amostras reais (café, sumo de laranja e água aromatizada de laranja) usando-se como agentes oxidantes o H2O2 e NO•. Todas as amostras analisadas apresentaram ter capacidade antioxidante. Quando se utilizou o dA20-EPC na presença de H2O2, verificou-se que as amostras de café apresentam valores mais elevados de CAT (1130-1488 mg AAE/L) do que as amostras de bebidas (110 mg AAE/L em água aromatizada e 775 mg AAE/L em sumo). Os valores de CAT obtidos para amostras de sumo e água aromatizada na presença de NO• indicam que a amostra de sumo possui maior teor de CAT (871 mg AAE/L) conforme era esperado, do que a amostra de água aromatizada (172 mg AAE/L). Na presença de HClO, o valor de CAT mais elevado pertence a uma amostra de sumo (513 mg AAE/L) mas, o valor de CAT da amostra de sumo natural é muito mais baixa do que o esperado (17 mg AAE/L). Foram estudados outros antioxidantes para além do AA (ácido cumárico, ácido gálico e ácido cafeico), e constatou-se que cada um deles promove proteção ao dA20-EPC na presença de cada um dos diferentes contaminantes (H2O2, NO• e HClO).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: A presente dissertação para tese de doutoramento apresenta o desenvolvimento e a validação de um método simples e original para o diagnóstico de calcificações vasculares em doentes em diálise, utilizando um score semiquantitativo criado por nós e obtido em RX simples da bacia e das mãos, denominado score de calcifi cação vascular simples. Demonstramos que este score vascular simples é preditor de risco cardiovascular nos doentes em diálise. O score de calcificação vascular simples associou-se ainda à baixa densidade mineral óssea avaliada por dual energy X -ray absortiometry (DXA) no colo do fémur. Verifi camos igualmente que, em doentes em diálise, as calcifi cações coronárias quantifi cadas pelo score de Agatston e o score de calcifi cação vascular simples se associaram a um menor volume ósseo avaliado em biopsias ósseas. Estes trabalhos corroboram a hipótese da existência de um elo de ligação entre a doença óssea e a doença vascular nos doentes em diálise, e um dos elementos que contribuem para este elo de ligação podem ser as calcificações vasculares. Este score de calcificação vascular simples avalia calcifi cações em artérias de grande, médio e pequeno calibre, e inclui os dois padrões radiológicos de calcificação: calcificação linear, associada à calcifi cação da camada média da parede arterial, e calcificação irregular, associada à calcifi cação da camada íntima arterial1. Nos diferentes trabalhos por nós publicados demonstramos que as calcificações vasculares avaliadas por este método simples e barato permitem a identificação de indivíduos com elevado risco cardiovascular. Este score vascular associa -se a maior risco de mortalidade cardiovascular2, de mortalidade de causa global3, de internamentos cardiovasculares2, de doença ardiovascular2, de doença arterial periférica2,4,de calcifi cações valvulares5 e de rigidez arterial3. As guidelines KDIGO (Kidney disease: improving global outcomes), publicadas em 2009,sugerem que os doentes renais crónicos nos estadios 3 a 5, com calcificações vasculares e valvulares, devem ser considerados como apresentando o mais elevado risco cardiovascular6. A elevada mortalidade dos doentes renais crónicos não é totalmente explicada pelos fatores de risco tradicionais7. A organização KDIGO defende, desde 2006, a hipótese da existência de um elo de ligação entre a doença óssea e a doença vascular8. Esta ligação pode ser explicada pelas alterações do metabolismo mineral e ósseo e pela sua interação com as calcificações vasculares. Verificamos, nos nossos trabalhos, uma associação entre calcifi cações vasculares e doença óssea. O baixo volume ósseo diagnosticado por análise histomorfométrica de biopsias ósseas foi preditor de maior risco de calcificações vasculares avaliadas pelo score de calcifi cação vascular simples (dados apresentados nesta dissertação, no capítulo 6) e pelo score coronário de Agatston num grupo de doentes em diálise9. A contribuição original deste artigo9 foi considerada merecedora de um editorial feito pelo Dr. Gérard London10, investigador líder na área da calcificação vascular dos doentes renais crónicos e actual Presidente da EDTA (European Dialysis and Transplantation Association). Fomos também os primeiros a descrever uma associação independente e inversa entre a densidade mineral avaliada no colo do fémur por DXA (dual energy X -ray absortiometry) com calcificações vasculares avaliadas pelo score de calcificação vascular simples, com rigidez arterial avaliada por velocidade de onda de pulsocarotidofemoral e com doença arterial periférica diagnosticada por critérios clínicos11. Fomos igualmente os primeiros a mostrar uma correlação signifi cativa entre a densidade mineral óssea avaliada por DXA no colo do fémur, mas não na coluna lombar, com a espessura cortical avaliada por análise histomorfométrica em biopsia óssea12. O nosso estudo atribui pela primeira vez à DXA um papel no diagnóstico de porosidade cortical nos doentes em diálise. A utilidade da avaliação diferencial da densidade mineral óssea cortical e trabecular necessita ainda de ser confirmada em estudos prospectivos. Este achado inovador do nosso estudo foi mencionado pela ERBP (European Renal Best Practice) no comentário feito à posição da KDIGO que considera ser reduzida a utilidade da densidade mineral óssea nos doentes em diálise13. Dois dos trabalhos incluídos nesta dissertação foram referenciados nas guidelines KDIGO 2009 para avaliar a prevalência das calcificações vasculares (KDIGO 2009: Tabela suplementar 10, Fig. 3.6) e para validar a associação entre calcificações vasculares e mortalidade cardiovascular (KDIGO 2009: Tabela suplementar 12, Fig. 3.7)6. A inclusão destes nossos dois estudos nas referências destas guidelines, que utilizaram o exigente sistema GRADE (Grades of recommendation, assessment, development, and evaluation) na classificação e selecção dos estudos, valida o interesse científico dos nossos trabalhos. O diagnóstico de calcificações vasculares tem um interesse prático para os doentes renais crónicos. A presença de calcifi cações vasculares é um sinal de alerta para a existência de um elevado risco cardiovascular, e esta informação pode ser utilizada para modificar a terapêutica nestes doentes6. Diferentes métodos podem ser usados para diagnosticar calcificações vasculares nos doentes em diálise14,15. O score de calcificação vascular simples tem a vantagem da simplicidade e de poder ser facilmente interpretado pelo nefrologista, sem necessidade de um radiologista. A reprodutibilidade deste score já foi demonstrada por diferentes grupos em estudos nacionais e internacionais16-24. Nestes estudos foi demonstrado que as calcifi cações vasculares avaliadas pelo método criado por nós são preditoras de maior risco de eventos cardiovasculares16, de amputações dos membros inferiores17, de velocidade de onda de pulso18,19, de calcificações corneanas e conjuntivais20 e de calcifi cações coronárias21. Também foi demonstrada uma associação inversa entre o score de calcificação vascular simples com os níveis séricos de PTH21, com os níveis de 25(OH)vitamina D 22,23 e com os níveis de fetuína A19,24. Todos estes estudos, realizados por diferentes grupos, que utilizaram o score de calcificação vascular simples na sua metodologia, comprovam a facilidade de utilização deste score e a concordância de resultados atestam a sua reprodutibilidade e a utilidade na avaliação dos doentes renais crónicos. ---------------------------ABSTRACT: This thesis presents the development and validation of a simple and original method to identify vascular calcifications in dialysis patients, using a semi -quantitative score that we have created and that is obtained in plain X -ray of pelvis and hands. This score was named in different publications as “simple vascular calcifi cation score”. We have demonstrated that this score is a predictor of higher cardiovascular risk in dialysis patients. The simple vascular calcification score was also associated with lower mineral bone density evaluated by DXA in femoral neck. In hemodialysis patients coronary calcifications evaluated by the coronary Agatston score and by the simple vascular calcification score were associated with lower bone volume analysed in bone biopsies. These studies corroborate the hypothesis of the existence of a link between bone disease and vascular disease in dialysis patients and one of the elements of this link may be vascular calcifications. This simple vascular calcification score identifi es calcifications in large, medium and small calibre arteries and includes the two radiological patterns of arterial calcifi cation: linear calcification which has been associated with the calcifi cation of the media layer of the arterial wall and irregular and patchy calcification which has been associated with the calcifi cation of the intima layer of the arterial wall1. In the several studies that we have published we have demonstrated that vascular calcifications evaluated by this simple and inexpensive method allow the identification of patients with high cardiovascular risk. This simple vascular calcification score is an independent predictor of cardiovascular mortality2, all -cause mortality3, cardiovascular hospitalizations2, cardiovascular disease2, peripheral artery disease2,4, valvular calcifi cations5 and arterial stiffness3.KDIGO (Kidney Disease: Improving Global Outcomes) guidelines published in 2009 suggest that chronic kidney disease patients in stages 3 to 5, with vascular and valvular calcifications should be considered to be at the highest cardiovascular risk6. The high mortality of chronic kidney disease patients is not completely explained by the traditional risk factors7 and KDIGO group supports, since 2006, the hypothesis of the existence of a link between bone disease and vascular disease8.This link may be explained by the alterations of the bone and mineral metabolism and their interaction with development and progression of vascular calcifications. We have also verifi ed in our studies the existence of an association between vascular calcifications and bone disease. Low bone volume diagnosed by histomorphometric analysis of bone biopsies, in a group of dialysis patients, was independently associated with the simple vascular calcification score (data presented in this thesis,chapter 6) and with coronary calcifications evaluated by the Agatston score9. The original contribution of this article published in CJASN9 deserved a commentary in an Editorial written by Prof. Gérard London10 leader investigator in this area and current EDTA (European Dialysis and Transplantation Association) President. We were also the fi rst group to describe an independent and inverse association between bone mineral density evaluated in the femoral neck by DXA (dual energy X -ray absortiometry) with vascular calcifications evaluated by the simple vascular calcification score, with arterial stiffness evaluated by carotid-femoral pulse wave velocity and with peripheral artery disease diagnosed by clinical criteria11. We were also the first group to demonstrate a significant correlation between bone mineral density evaluated by DXA in femoral neck but not in lumbar spine, with cortical thickness evaluated by histomorphometric analysis of bone biopsy12. Our study has attributed to DXA, for the first time, a role in the diagnosis of cortical porosity in dialysis patients. The clinical utility of the differential evaluation of bone mineral density in cortical or trabecular bone needs, however, to be confi rmed in prospective studies. This original fi nding of our study was mentioned by ERBP (European Renal Best Practice) commenting the KDIGO position in relation with the reduced utility of bone mineral density evaluation in dialysis patients13. Two of the studies included in this thesis have been integrated in a group of studies selected as references by the KDIGO guidelines published in 2009 to evaluate the prevalence of vascular calcifications in CKD patients (KDIGO 2009: Supplementary Table 10, Fig. 3.6) and to corroborate the association between vascular calcifications and cardiovascular mortality (KDIGO 2009: Supplementary Table 12, Fig. 3.7)6. The inclusion of both studies as references in the KDIGO guidelines that have used the exigent GRADE system (Grades of Recommendation, Assessment, Development, and Evaluation) in the classifi cation and selection of studies, validates the scientifi c value of our studies. The diagnosis of vascular calcifi cations has a practical interest for chronic kidney disease patients. The presence of vascular calcifications is an alert sign to the existence of a high cardiovascular risk and this information may be used to modify the treatment of these patients6. Different methods may be used to detect the presence of vascular calcifications in dialysis patients14,15. The simple vascular calcifi cation score has the advantage of being simple, inexpensive and easily evaluated by the Nephrologist without the need for a Radiologist interpretation. The reproducibility of this method has already been demonstrated by other groups in national and international studies16 -24. It was demonstrated in those studies that vascular calcifi cations evaluated by the method created by us, predict higher risk of cardiovascular events16, higher risk of lower limbs amputations17, higher pulse wave velocity18,19, corneal and conjuntival calcifi cations 20 and coronary calcifi cations21. A negative association between the simple vascular calcification score and PTH levels21, 25(OH) vitamin D levels22,23 and Fetuin A levels19,24 has also been demonstrated. All these studies performed by different groups that have used the simple vascular calcifi cation score in their methods demonstrate that this score is simple, useful and reproducible in the evaluation of chronic kidney disease patients simple, useful and reproducible in the evaluation of chronic kidney disease patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparison of the Etest and the reference broth macrodilution susceptibility test for fluconazole, ketoconazole, itraconazole and amphotericin B was performed with 59 of Candida species isolated from the oral cavities of AIDS patients. The Etest method was performed according to the manufacturer's instructions, and the reference method was performed according to National Committee for Clinical Laboratory Standards document M27-A guidelines. Our data showed that there was a good correlation between the MICs obtained by the Etest and broth dilution methods. When only the MIC results at ± 2 dilutions for both methods were considered, the agreement rates were 90.4% for itraconazole, ketoconazole and amphotericin B and 84.6% for fluconazole of the C. albicans tested. In contrast, to the reference method, the Etest method classified as susceptible three fluconazole-resistant isolates and one itraconazole-resistant isolate, representing four very major errors. These results indicate that Etest could be considered useful for antifungal sensitivity evaluation of yeasts in clinical laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ammonia is an important gas in many power plants and industrial processes so its detection is of extreme importance in environmental monitoring and process control due to its high toxicity. Ammonia’s threshold limit is 25 ppm and the exposure time limit is 8 h, however exposure to 35 ppm is only secure for 10 min. In this work a brief introduction to ammonia aspects are presented, like its physical and chemical properties, the dangers in its manipulation, its ways of production and its sources. The application areas in which ammonia gas detection is important and needed are also referred: environmental gas analysis (e.g. intense farming), automotive-, chemical- and medical industries. In order to monitor ammonia gas in these different areas there are some requirements that must be attended. These requirements determine the choice of sensor and, therefore, several types of sensors with different characteristics were developed, like metal oxides, surface acoustic wave-, catalytic-, and optical sensors, indirect gas analyzers, and conducting polymers. All the sensors types are described, but more attention will be given to polyaniline (PANI), particularly to its characteristics, syntheses, chemical doping processes, deposition methods, transduction modes, and its adhesion to inorganic materials. Besides this, short descriptions of PANI nanostructures, the use of electrospinning in the formation of nanofibers/microfibers, and graphene and its characteristics are included. The created sensor is an instrument that tries to achieve a goal of the medical community in the control of the breath’s ammonia levels being an easy and non-invasive method for diagnostic of kidney malfunction and/or gastric ulcers. For that the device should be capable to detect different levels of ammonia gas concentrations. So, in the present work an ammonia gas sensor was developed using a conductive polymer composite which was immobilized on a carbon transducer surface. The experiments were targeted to ammonia measurements at ppb level. Ammonia gas measurements were carried out in the concentration range from 1 ppb to 500 ppb. A commercial substrate was used; screen-printed carbon electrodes. After adequate surface pre-treatment of the substrate, its electrodes were covered by a nanofibrous polymeric composite. The conducting polyaniline doped with sulfuric acid (H2SO4) was blended with reduced graphene oxide (RGO) obtained by wet chemical synthesis. This composite formed the basis for the formation of nanofibers by electrospinning. Nanofibers will increase the sensitivity of the sensing material. The electrospun PANI-RGO fibers were placed on the substrate and then dried at ambient temperature. Amperometric measurements were performed at different ammonia gas concentrations (1 to 500 ppb). The I-V characteristics were registered and some interfering gases were studied (NO2, ethanol, and acetone). The gas samples were prepared in a custom setup and were diluted with dry nitrogen gas. Electrospun nanofibers of PANI-RGO composite demonstrated an enhancement in NH3 gas detection when comparing with only electrospun PANI nanofibers. Was visible higher range of resistance at concentrations from 1 to 500 ppb. It was also observed that the sensor had stable, reproducible and recoverable properties. Moreover, it had better response and recovery times. The new sensing material of the developed sensor demonstrated to be a good candidate for ammonia gas determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low-cost disposable was developed for rapid detection of the protein biomarker myoglobin (Myo) as a model analyte. A screen printed electrode was modified with a molecularly imprinted material grafted on a graphite support and incorporated in a matrix composed of poly(vinyl chloride) and the plasticizer o-nitrophenyloctyl ether. The protein-imprinted material (PIM) was produced by growing a reticulated polymer around a protein template. This is followed by radical polymerization of 4-styrenesulfonic acid, 2-aminoethyl methacrylate hydrochloride, and ethylene glycol dimethacrylate. The polymeric layer was then covalently bound to the graphitic support, and Myo was added during the imprinting stage to act as a template. Non-imprinted control materials (CM) were also prepared by omitting the Myo template. Morphological and structural analysis of PIM and CM by FTIR, Raman, and SEM/EDC microscopies confirmed the modification of the graphite support. The analytical performance of the SPE was assessed by square wave voltammetry. The average limit of detection is 0.79 μg of Myo per mL, and the slope is −0.193 ± 0.006 μA per decade. The SPE-CM cannot detect such low levels of Myo but gives a linear response at above 7.2 μg · mL−1, with a slope of −0.719 ± 0.02 μA per decade. Interference studies with hemoglobin, bovine serum albumin, creatinine, and sodium chloride demonstrated good selectivity for Myo. The method was successfully applied to the determination of Myo urine and is conceived to be a promising tool for screening Myo in point-of-care patients with ischemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sol-gel chemistry allows the immobilization of organic molecules of biological origin on suibtable solid supports, permitting their integration into biosensing devices widening the possibility of local applications. The present work is an application of this principle, where the link between electrical receptor platform and the antibody acting as biorecognition element is made by sol-gel chemistry. The immunosensor design was targeted for carcinoembryonic antigen (CEA), an important biomarker for screening the colorectal cancer, by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SVW). The device displayed linear behavior to CEA in EIS and in SWV assays ranging from 0.50 to 1.5ng/mL, and 0.25 to 1.5ng/mL, respectively. The corresponding detection limits were 0.42 and 0.043 ng/mL. Raman spectroscopy was used to characterize the surface modifications on the conductive platform (FTO glass). Overall, simple sol-gel chemistry was effective at the biosensing design and the presented approach can be a potential method for screening CEA in point-of-care, due to the simplicity of fabrication, short response time and low cost. - See more at: http://www.eurekaselect.com/127192/article#sthash.m1AWhINx.dpuf

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The local fractional Poisson equations in two independent variables that appear in mathematical physics involving the local fractional derivatives are investigated in this paper. The approximate solutions with the nondifferentiable functions are obtained by using the local fractional variational iteration method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1st ASPIC International Congress

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryptococcus neoformans detection was optimized using PCR technique with the objective of application in the clinical laboratory diagnosis. The amplification area was ITS and 5,6S which encodes the ribosomal RNA (rRNA). A total of 72 cerebrospinal fluid (CSF) samples were used, obtained from cases with and without AIDS. The patients had cryptococcal meningitis (n = 56) and meningitis caused by other agents (n = 16). The results demonstrated that PCR test had the highest sensitivity rates, superior to culture (85.7%) and to India ink test (76.8%). PCR was found to be sensitive in detecting 1 cell/mL and highly specific since it did not amplify other fungal DNA. The comparative analysis of the methods showed that PCR is more sensitive and specific and is applicable as an important laboratorial resource for neurocryptococcosis diagnosis.