913 resultados para repetition tunable
Resumo:
This work develops a methodology (using the degree-days concept and linear regression), to forecast the duration of phenological phases in crops. An experiment was conducted in the greenhouse with three cultivars of cowpea (Vigna unguiculata (C.) Walp.), cv. California-781, Tvx 5058-09C and IT 81D-1032. The methodology was based on the relative thermal efficiency rate, determined for each species or cv. The results show that the proposed methodology may be a good alternative in works involving crops, especially because it does not require the repetition of the experiments.
Resumo:
A constant-current stimulator for high-impedance loads using only low-cost standard high-voltage components Is presented. A voltage-regulator powers an oscillator built across the primary of a step-up transformer whose secondary supplies, after rectification, the high voltage to a switched current-mirror in the driving stage. Adjusting the regulated voltage controls the pulsed-current intensity. A prototype produces stimulus of amplitude and pulsewidth within 0 less than or equal to I-skin less than or equal to 20 mA and 50 mus less than or equal to T-pulse less than or equal to 1 ms, respectively. Pulse-repetition spans from 1 Hz to 10 Hz. Worst case ripple is 3.7% at I-skin = 1 mA. Overall consumption is 5.6 W at I-skin = 20 mA.
Resumo:
Surface modifications have been applied in endosteal bone devices in order to improve the osseointegration through direct contact between neoformed bone and the implant without an intervening soft tissue layer. Surface characteristics of titanium implants have been modified by addictive methods, such as metallic titanium, titanium oxide and hydroxyapatite powder plasma spray, as well as by subtractive methods, such as acid etching, acid etching associated with sandblasting by either AlO2 or TiO2, and recently by laser ablation. Surface modification for dental and medical implants can be obtained by using laser irradiation technique where its parameters like repetition rate, pulse energy, scanning speed and fluency must be taken into accounting to the appropriate surface topography. Surfaces of commercially pure Ti (cpTi) were modified by laser Nd:YVO4 in nine different parameters configurations, all under normal atmosphere. The samples were characterized by SEM and XRD refined by Rietveld method. The crystalline phases alpha Ti, beta Ti, Ti6O, Ti3O and TiO were formed by the melting and fast cooling processes during irradiation. The resulting phases on the irradiated surface were correlated with the laser beam parameters: the aim of the present work was to control titanium oxides formations in order to improve implants osseointegration by using a laser irradiation technique which is of great importance to biomaterial devices due to being a clean and reproducible process. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
Introduction Oral mucositis (OM) is a significant early complication of hematopoietic cell transplantation (HCT). This phase III randomized double-blind placebo-controlled study was designed to compare the ability of 2 different low level GaAlAs diode lasers (650 nm and 780 nm) to prevent oral mucositis in HCT patients conditioned with chemotherapy or chemoradiotherapy.Materials and methods Seventy patients were enrolled and randomized into 1 of 3 treatment groups: 650 nm laser, 780 nm laser or placebo. All active laser treatment patients received daily direct laser treatment to the lower labial mucosa, right and left buccal mucosa, lateral and ventral surfaces of the tongue, and floor of mouth with energy densities of 2 J/cm(2). Study treatment began on the first day of conditioning and continued through day +2 post HCT. Mucositis and oral pain was measured on days 0, 4, 7, 11, 14, 18, and 21 post HCT.Results the 650 nm wavelength reduced the severity of oral mucositis and pain scores. Low level laser therapy was well-tolerated and no adverse events were noted.Discussion While these results are encouraging, further study is needed to truly establish the efficacy of this mucositis prevention strategy. Future research needs to determine the effects of modification of laser parameters (e.g., wavelength, fluence, repetition rate of energy delivery, etc.) on the effectiveness of LLE laser to prevent OM.
Resumo:
The objective of this study was to compare the effect of different strength training protocols added to endurance training on running economy (RE). Sixteen well-trained runners (27.4 +/- 4.4 years; 62.7 +/- 4.3 kg; 166.1 +/- 5.0 cm), were randomized into two groups: explosive strength training (EST) (n = 9) and heavy weight strength training (HWT) (n = 7) group. They performed the following tests before and after 4 weeks of training: 1) incremental treadmill test to exhaustion to determine of peak oxygen uptake and the velocity corresponding to 3.5 mM of blood lactate concentration; 2) submaximal constant-intensity test to determine RE; 3) maximal countermovernent jump test and; 4) one repetition maximal strength test in leg press. After the training period, there was an improvement in RE only in the HWT group (HWT = 47.3 +/- 6.8 vs. 44.3 +/- 4.9 ml.kg(-1) -min(-1); EST = 46.4 +/- 4.1 vs. 45.5 +/- 4.1 ml.kg(-1) .min(-1)). In conclusion, a short period of traditional strength training can improve RE in well-trained runners, but this improvement can be dependent on the strength training characteristics. When comparing to explosive training performed in the same equipment, heavy weight training seems to be more efficient for the improvement of RE.
Resumo:
The slope of the distance-time relationship from maximal 200 and 400 in bouts (S(200-400)) has been increasingly employed for setting training intensities in swimming. However, physiological and mechanical responses at this speed are poorly understood. Thus, this study investigated blood lactate, heart rate (HR), stroke rate (SR), stroke length (SL) and RPE responses to an interval swimming set at S(200-400) in trained swimmers. In a 50-m pool, twelve athletes (16.5 +/- 1.2 yr, 176 +/- 7 cm, 68.4 +/- 5.4 kg, and 7.8 +/- 2.5% body fat) performed maximal 200 and 400 m crawl trials for S(200-400) determination (1.28 +/- 0.05 m/s). Thereafter, swimmers were instructed to perform 5 x 400 in at this speed with 1.5 min rest between repetitions. Three athletes Could not complete the set (exhaustion at 21.0 +/- 3.1 min). For the remaining swimmers (total set duration = 32.0 +/- 1.3 min) significant increases) (p < 0.05) in blood lactate (5.7 +/- 0.8-7.9 +/- 2.4 mmol/l), SR (29.6 +/- 3.2-32.1 +/- 4.1 cycles/min), HR (169 +/- 11-181 +/- 8 bpm) and RPE (13.3 +/- 1.6-16.3 +/- 2.6) were observed through the IS. Conversely, SL decreased significantly (p < 0.05) from the first to the fifth repetition (2.48 +/- 0.22-2.31 +/- 0.24 m/cycle). These results suggest that interval swimming at S(200-400) represents an intense physiological, mechanical and perceptual stimulus that can be sustained for a prolonged period by most athletes. (C) 2008 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The effects of ultrasound on the wound healing process after teeth extractions were studied histologically. The right upper incisor was extracted in 56 rats. They were divided into 2 groups, one control (I) and one experimental (II). Group II received ultrasound stimulation that was applied with the frequency of repetition of 1,000 Hz and pulse length of 2,000 us continuously, during five minutes daily since the extraction day until 24 hours before the death. The rats were sacrificed at 3, 6, 9, 12, 15, 18, and 21 postoperative days. The results showed a precocious granulation tissue formation, faster remodeling of osseous ridges, and consequently acceleration of the alveolar wound healing process.
Resumo:
Three species of filamentous fungi, Aspergillus niger, Penicillium fellutanum and Mucor hiemalis, were selected and cultivated in vinasse media with different addition of molasses, pasteurized to 85°C for 30 minutes and with pH = 5.0. The microorganisms, previously adapted to the respective medium for 48 hours, from a solution of 107 spores.ml-1, were cultivated in pure and mixed cultures in Erlenmeyer vessel of 500ml, to 30°C, with constant agitation of 170 rpm, for 24, 48 and 72 hours, with four repetition for each samples. The biomass was separated by vacuum filtration in filter Whatman #1 and dried in oven at 105°C until right weight, the obtained liquid was submited to COD analysis. The datas were statistically analysed using a response surface methodology, to improve the effect on the molasses proportion and culture time, in the biomass production by microorganism in research. According to the obtained results (5.02% of molasses, 55.59h, 70% of spores solution of A. niger and 30% of spores solution of P. fellutanum), cultivating was carried out in Microferm Fermentor New Brunswick for 48 hours at 300 rpm, aired at 1v/v/m, using 5 liters of medium added with 5.0% of molasses on the conditions above described. The average of the results obtained (6.81g.l-1) was higher than the confidence interval (5.937 ; 6.369) and was inside the prediction interval (4.471 ; 7.834) both of them significant at 95% by the statistical test employed.
Resumo:
This work develops a methodology (using the degree-days concept and linear regression), to forecast the duration of phenological phases in crops. An experiment was conducted in the greenhouse with three cultivars of cowpea (Vigna unguiculata (L.) Walp.), cv. Califórnia-781, Tvx 5058-09C and IT 81D-1032. The methodology was based on the relative thermal efficiency rate, determined for each species or cv. The results show that the proposed methodology may be a good alternative in works involving crops, especially because it does not require the repetition of the experiments.
Resumo:
A simple constant-current electrocutaneous stimulator for high-impedance loads using low-cost, standard high-voltage components is presented. A voltage-regulator powers an oscillator built across the primary of a transformer whose secondary delivers, after rectification, the high-voltage supply to switched current-mirrors in the driving stage. Since the compliance high-voltage is proportional to the stimulation current, overall power consumption is minimized. By adjusting the regulated voltage, control of the pulsed-current amplitude is achieved. A prototype with readily available components features stimulation currents of amplitude and pulsewidth in the range 0≤Iskin≤20mA and 50μs ≤Tpulse≤1ms, respectively. Pulse-repetition spans from 1 Hz to 10Hz. Worst-case ripple is 3.7% @Iskin=1mA. Measured pulse fall-time is shorter than 32μs. Overall consumption is 4.4W @Iskin=20mA. Subject isolation from line is 4KV.
Resumo:
A quasi-sinusoidal linearly tunable OTA-C VCO built with triode-region transconductors is presented. Oscillation upon power-on is ensured by RHP poles associated with gate-drain capacitances of OTA input devices. Since the OTA nonlinearity stabilizes the amplitude, the oscillation frequency f0 is first-order independent of VDD, making the VCO adequate to mixed-mode designs. A range of simulations attests the theoretical analysis. As part of a DPLL, the VCO was prototyped on a 0.8μm CMOS process, occupying an area of 0.15mm2. Nominal f0 is 1MHz, with K VCo=8.4KHz/mV. Measured sensitivity to VDD is below 2.17, while phase noise is -86dBc at 100-KHz offset. The feasibility of the VCO for higher frequencies is verified by a redesign based on a 0.35μm CMOS process and VDD=3.3V, with a linear frequency-span of l3.2MHz - 61.5MHz.
Resumo:
A low-voltage low-power 2nd-order CMOS pseudo-differential bump-equalizer is presented. Its topology comprises a bandpass section with adjustable center frequency and quality factor, together with a programmable current amplifier. The basic building blocks are triode-operating transconductors, tunable by means of either a DC voltage or a digitally controlled current divider. The bump-equalizer as part of a battery-operated hearing aid device is designed for a 1.4V-supply and a 0.35μm CMOS fabrication process. The circuit performance is supported by a set of simulation results, which indicates a center frequency from 600Hz to 2.4kHz, 1≤Q≤5, and an adjustable gain within ±6dB at center frequency. The filter dynamic range lies around 40dB. Quiescent consumption is kept below 12μW for any configuration of the filter.
Resumo:
In this work we present a description of the advertisement call of H. jimi, the locality type, and of H. elianeae, until now unknown in the literature. Field activities were carried out from August 1997 through June 1999; recordings were made in two open-area environments in the Botucatu region, São Paulo State. Vocalizations of 100 individuals (49 H. jimi and 51 H. elianeae) were recorded; nine characteristics of the advertisement call were examined. The advertisement calls of both species consist of consecutive series of simple notes with relatively fast repetition rates. Males of H. jimi and H. elianeae presented two patterns of note emission: one emitted by individuals beginning vocalization activity or isolated from the aggregate, and another emitted by males in chorus activity interacting with closely neighboring males. A significant difference was verified in the temporal structure of the two vocalization patterns.