985 resultados para partial discharge measurement
Resumo:
A simple method is described to combine a modern function generator and a digital oscilloscope to configure a setup that can directly measure the amplitude frequency response of a system. This is achieved by synchronously triggering both instruments, with the function generator operated in the ``Linear-Sweep'' frequency mode, while the oscilloscope is operated in the ``Envelope'' acquisition mode. Under these conditions, the acquired envelopes directly correspond to the (input and output signal) spectra, whose ratio yields the amplitude frequency response. The method is easy to configure, automatic, time-efficient, and does not require any external control or interface or programming. This method is ideally suited to impart hands-on experience in sweep frequency response measurements, demonstrate resonance phenomenon in transformer windings, explain the working principle of an impedance analyzer, practically exhibit properties of network functions, and so on. The proposed method is an inexpensive alternative to existing commercial equipment meant for this job and is also an effective teaching aid. Details of its implementation, along with some practical measurements on an actual transformer, are presented.
Resumo:
A wire-cylinder corona discharge was studied in nitrogen and dry air in crossed electric and magnetic fields for values of magnetic field ranging from 0 to 3000 G with the wire at positive potential. In the absence of a magnetic field pre-onset streamers and pulses were observed in nitrogen. In both nitrogen and dry air breakdown streamers were observed just before spark breakdown of the gap. Furthermore, experiments in dry air at atmospheric pressure in an electric field indicate regular pre-onset streamers appearing at time intervals of 19.5 µs. The appearance of regular pre-onset streamers suggests that it is not possible for negative ions to form a sheath close to the anode as postulated by Hermstein (1960) for the formation of steady or glow corona in a point-plane gap.
Resumo:
We present a laser-based system to measure the refractive index of air over a long path length. In optical distance measurements it is essential to know the refractive index of air with high accuracy. Commonly, the refractive index of air is calculated from the properties of the ambient air using either Ciddor or Edlén equations, where the dominant uncertainty component is in most cases the air temperature. The method developed in this work utilises direct absorption spectroscopy of oxygen to measure the average temperature of air and of water vapor to measure relative humidity. The method allows measurement of temperature and humidity over the same beam path as in optical distance measurement, providing spatially well matching data. Indoor and outdoor measurements demonstrate the effectiveness of the method. In particular, we demonstrate an effective compensation of the refractive index of air in an interferometric length measurement at a time-variant and spatially non-homogenous temperature over a long time period. Further, we were able to demonstrate 7 mK RMS noise over a 67 m path length using 120 s sample time. To our knowledge, this is the best temperature precision reported for a spectroscopic temperature measurement.
Resumo:
The proportion of patients over 75 years of age, receiving all different types of healthcare, is constantly increasing. The elderly undergo surgery and anaesthetic procedures more often than middle-aged patients. Poor pain management in the elderly is still an issue. Although the elderly consumes the greatest proportion of prescribed medicines in Western Europe, most clinical pharmacological studies have been performed in healthy volunteers or middle-aged patients. The aim of this study was to investigate pain measurement and management in cognitively impaired patients in long term hospital care and in cognitively normal elderly patients after cardiac surgery. This thesis incorporated 366 patients, including 86 home-dwelling or hospitalized elderly with chronic pain and 280 patients undergoing cardiac surgery with acute pain. The mean age of patients was 77 (SD ± 8) years and approximately 8400 pain measurements were performed with four pain scales: Verbal Rating Scale (VRS), the Visual Analogue Scale (VAS), the Red Wedge Scale (RWS), and the Facial Pain Scale (FPS). Cognitive function, depression, functional ability in daily life, postoperative sedation and postoperative confusion were assessed with MMSE, GDS, Barthel Index, RASS, and CAM-ICU, respectively. The effects and plasma concentrations of fentanyl and oxycodone were measured in elderly (≥ 75 years) and middle-aged patients (≤ 60 years) and the opioid-sparing effect of pregabalin was studied after cardiac surgery. The VRS pain scores after movement correlated with the Barthel Index. The VRS was most successful in the groups of demented patients (MMSE 17-23, 11-16 and ≤ 10) and in elderly patients on the first day after cardiac surgery. The elderly had a higher plasma concentration of fentanyl at the end of surgery than younger patients. The plasma concentrations of oxycodone were comparable between the groups. Pain intensity on the VRS was lower and the sedation scores were higher in the elderly. Total oxycodone consumption during five postoperative days was reduced by 48% and the CAM-ICU scores were higher on the first postoperative day in the pregabalin group. The incidence of postoperative pain during movement was lower in the pregabalin group three months after surgery. This investigation demonstrates that chronic pain did not seem to impair daily activities in home-dwelling Finnish elderly. The VRS appeared to be applicable for elderly patients with clear cognitive dysfunction (MMSE ≤17) and it was the most feasible pain scale for the early postoperative period after cardiac surgery. After cardiac surgery, plasma concentrations of fentanyl in elderly were elevated, although oxycodone concentrations were at similar level compared to middle-aged patients. The elderly had less pain and were more sedated after doses of oxycodone. Therefore, particular attention must be given to individual dosing of the opioids in elderly surgical patients, who often need a smaller amount for adequate analgesia than middle-aged patients. The administration of pregabalin reduced postoperative oxycodone consumption after cardiac surgery. Pregabalin-treated patients had less confusion, and additionally to less postoperative pain on the first postoperative day and during movement at three months post-surgery. Pregabalin might be a new alternative as analgesic for acute postoperative and chronic pain management in the elderly. Its clinical role and safety remains to be verified in large-scale randomized and controlled studies. In the future, many clinical trials in the older category of patients will be needed to facilitate improvements in health care methods.
Resumo:
The phase diagram of the Ni-W-O system at 1200 K was established by metallographic and X-ray identification of the phases present after equilibration at controlled oxygen potentials. The oxygen partial pressures over the samples were fixed by metered streams of CO+CO2 gas mixtures. There was only one ternary oxide, nickel tungstate (NiWO4), in the Ni-W-O system at a total pressure of 1 atm, and this compound decomposed to a mixture of Ni+WO2.72 on lowering the oxygen potential. The Gibbs' free energy of formation of NiWO4 was determined from the measurement of the e.m.f. of the solid oxide galvanic cell, Pt, Ni+NiWO4+WO2.72/CaO-ZrO2/Ni+NiO, Pt and thermodynamic properties of tungsten and nickel oxides available in the literature. For the reaction, NiO(s)+WO3(s)rarrNiWO4(s) DeltaG°=–10500–0.708 T (±250) cal mol–1.
Resumo:
In this note we demonstrate the use of top polarization in the study of t (t) over bar resonances at the LHC, in the possible case where the dynamics implies a non-zero top polarization. As a probe of top polarization we construct an asymmetry in the decay-lepton azimuthal angle distribution (corresponding to the sign of cos phi(l)) in the laboratory. The asymmetry is non-vanishing even for a symmetric collider like the LHC, where a positive z axis is not uniquely defined. The angular distribution of the leptons has the advantage of being a faithful top-spin analyzer, unaffected by possible anomalous tbW couplings, to linear order. We study, for purposes of demonstration, the case of a Z' as might exist in the little Higgs models. We identify kinematic cuts which ensure that our asymmetry reflects the polarization in sign and magnitude. We investigate possibilities at the LHC with two energy options: root s = 14TeV and root s = 7TeV, as well as at the Tevatron. At the LHC the model predicts net top quark polarization of the order of a few per cent for M-Z' similar or equal to 1200GeV, being as high as 10% for a smaller mass of the Z' of 700GeV and for the largest allowed coupling in the model, the values being higher for the 7TeV option. These polarizations translate to a deviation from the standard-model value of azimuthal asymmetry of up to about 4% (7%) for 14 (7) TeV LHC, whereas for the Tevatron, values as high as 12% are attained. For the 14TeV LHC with an integrated luminosity of 10 fb(-1), these numbers translate into a 3 sigma sensitivity over a large part of the range 500 less than or similar to M-Z' less than or similar to 1500GeV.
Resumo:
A numerical analysis of flow to a dug well in an unconfined aquifer is made, taking into account well storage, elastic storage release, gravity drainage, anisotropy, partial penetration, vertical flow and seepage surface at the well face, and treating the water table in the aquifer and water level in the well as unknown boundaries. The pumped discharge is maintained constant. The solution is obtained by a two-level iterative scheme. The effects of governing parameters on the drawdown, development of seepage surface and contribution from aquifer flow to the total discharge are discussed. The degree of anisotropy and partial penetration are found to be the parameters which affect the flow characteristics most significantly. The effect of anisotropy on the development of seepage surface is very pronounced.
Resumo:
A simple three step procedure was used to purify microsomal NADH-cytochrome b5 (ferricyanide) reductase to homogeneity from the higher plant C. roseus. The microsomal bound reductase was solubilized using zwitterionic detergent-CHAPS. The solubilized reductase was subjected to affinity chromatography on octylamino Sepharose 4B, blue 2-Sepharose CL-6B and NAD+-Agarose. The homogeneous enzyme has an apparent molecular weight of 33,000 as estimated by SDS-PAGE. The purified enzyme catalyzes the reduction of purified cytochrome b5 from C. roseus in the presence of NADH. The reductase also readily transfers electrons from NADH to ferricyanide (Km 56 μM), 2,6-dichlorophenolindophenol (Km 65 μM) and cytochrome Image via cytochrome b5 but not to menadione.
Resumo:
Equilibrium of dissolution of sulfur dioxide at ppm levels in aqueous solutions of dilute sulfuric acid is analyzed, and a general expression is derived relating the total concentration of sulfur dioxide in the liquid phase to the partial pressure of SO2 in the gas and to the concentration of sulfuric acid in the solution. The equation is simplified for zero and high concentrations of the acid. Experiments at high concentrations of sulfuric acid have enabled the direct determination of Henry’s constant and its dependency on temperature. Heat of dissolution is -31.47 kJ/mol. Experiments in the absence of sulfuric acid and the related simplified expression have led to the determination of the equilibrium constant of the hydrolysis of aqueous sulfur dioxide and its temperature dependency.The heat of hydrolysis is 15.69 kJ/mol. The model equation with these parameters predicts the experimental data of the present work as well as the reported data very well.
Resumo:
Sesbania mosaic virus (SMV) is a plant virus infecting Sesbania grandiflora plants in Andhra Pradesh, India. Amino acid sequence of the tryptic peptides of SMV coat protein were determined using a gas phase sequenator. These sequences showed identical amino acids at 69% of the positions when aligned with the corresponding residues of southern bean mosaic virus (SBMV).Crystals diffracting to better than 3 Å resolution were obtained by precipitating the virus with ammonium sulphate. The crystals belonged to rhombohedral space group R3 with α = 291·4 Å and α = 61·9°. Three-dimensional X-ray diffraction data on these crystals were collected to a resolution of 4·7 Å, using a Siemens-Nicolet area detector system. Self-rotation function studies revealed the icosahedral symmetry of the virus particles, as well as their precise orientation in the unit cell. Cross-rotation function and modelling studies with SBMV showed that it is a valid starting model for SMV structure determination. Low resolution phases computed using a polyalanine model of SBMV were subjected to refinement and extension by real-space electron density averaging and solvent flattening. The final electron density map revealed a polypeptide fold similar to SBMV. The single disulphide bridge of SBMV coat protein is retained in SMV. Four icosahedrally independent cation binding sites have been tentatively identified. Three of these sites, related by a quasi threefold axis, are also found in SBMV. The fourth site is situated on the quasi threefold axis. Aspartic acid residues, which replace Ile218 of SBMV from the quasi threefold-related subunits are suitable ligands to the cation at this site