977 resultados para load-sensitive materials


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Sensitive Aunt Provotype was designed as part of Indoor Climate, a three-year research study of participatory design and user-driven innovation. It resulted from collaboration between two universities and five industry partners. Indoor Climate sought to understand experiences of comfort in domestic, business and institutional environments. This involved a literature review on the meaning of comfort, an ethnographic study of indoor environments, a provotyping process designed to provoke debate, and the design development of new products. A provotype is a provocative prototype. The title of the work Sensitive Aunt was derived from an analogy by one of the project partners and the colours emitted by the device represent the temperature, light intensity and air quality of the environment in which it is placed. In addition, the LED screen suggests actions to improve the indoor climate. The sensitive aunt provotype was designed to provoke conversation around different conceptions of a new product or service from the perspectives of manufacturers and design users. While both speculative design and provotypes inspire debate, speculative design focuses on the normative protocols of design industries while provotypes trigger discussion with the industry partners. Critically challenging ideas such as 21 degrees is the temperature in which people should be comfortable, provotypes combine participation and provocation and open up design to issues of refocus on usability and values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lecturing is a traditional method for teaching in discipline-based teaching environments and its success in legal discipline depends upon its alignment with learner backgrounds, learning objectives and the lecturing approaches utilised in the classes. In a situation where students do not have any prior knowledge of the given discipline that requires a particular lecturing approach, a mismatch in such an alignment would place learner knowledge acquisition into a challenging situation. From this perspective, this study tests the suitability of two dominant lecturing approaches—the case and the law-based lecturing approaches. It finds that a lecturer should put more emphasis on the case-based approach while lecturing to non-law background business students at the postgraduate level, provided that such an emphasis should be relative to the cognitive ability of the students and their motivation for learning law units.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanotubes and nanosheets are low-dimensional nanomaterials with unique properties that can be exploited for numerous applications. This book offers a complete overview of their structure, properties, development, modeling approaches, and practical use. It focuses attention on boron nitride (BN) nanotubes, which have had major interest given their special high-temperature properties, as well as graphene nanosheets, BN nanosheets, and metal oxide nanosheets. Key topics include surface functionalization of nanotubes for composite applications, wetting property changes for biocompatible environments, and graphene for energy storage applications

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports work involved with the automation of a Hot Metal Carrier — a 20 tonne forklift-type vehicle used to move molten metal in aluminium smelters. To achieve efficient vehicle operation, issues of autonomous navigation and materials handling must be addressed. We present our complete system and experiments demontrating reliable operation. One of the most significant experiments was five-hours of continuous operation where the vehicle travelled over 8 km and conducted 60 load handling operations. We also describe an experiment where the vehicle and autonomous operation were supervised from the other side of the world via a satellite phone network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osseointegration has been introduced in the orthopaedic surgery in the 1990’s in Gothenburg (Sweden). To date, there are two frequently used commercially available human implants: the OPRA (Integrum, Sweden) and ILP (Orthodynamics, Germany) systems. The rehabilitation program with both systems include some form of static load bearing exercises. These latter involved following a load progression that is monitored by the bathroom scale, providing only the load applied on the vertical axis. The loading data could be analysed through different biomechanical variables. For instance, the load compliance, corresponding to the difference between the load recommended (LR) and the load actually applied on the implant, will be presented here.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rehabilitation programs of bone-anchorage prostheses relying either on the OPRA (Integrum, Sweden) or the ILP (Orthodynamics, Germany) fixation involve some forms of static load bearing exercises (LBE). So far, most of biomechanical studies of these static LBEs focused on the direct measurements of the actual forces and moments applied on the OPRA fixation of individuals with transfemoral amputation (TFA). To date, the proof-of-concept of an apparatus to conduct these kinetic measurements has been presented, along with some preliminary data. The understanding of the kinetic data is essential to improve rehabilitation programs as well as the design of upcoming loading frames. However, kinetic information alone is difficult to interpret without concomitant kinematic data. The purpose of this preliminary study was to introduce a qualitative analysis describing the different body postures during LBE for a group of TFAs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Individuals with lower limb amputation fitted with an OPRA osseointegrated fixation are facing an extensive rehabilitation program including static load bearing exercises (LBE). The application of a suitable amount of stress stimulates osseointegration and prepares the bone to tolerate the forces and moments that will be incurred during activities of daily living (ADL. At present, the monitoring is typically carried out using a normal bathroom weighing scale. This scale provides information only on the magnitude of the vertical component of the applied force. The moment around the long axis of the fixation when the femur is perpendicular to the ground is not assessed and neither are the components of force and moment generated on the other two axes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The desire to solve problems caused by socket prostheses in transfemoral amputees and the acquired success of osseointegration in the dental application has led to the introduction of osseointegration in the orthopedic surgery. Since its first introduction in 1990 in Gothenburg Sweden the osseointegrated (OI) orthopedic fixation has proven several benefits[1]. The surgery consists of two surgical procedures followed by a lengthy rehabilitation program. The rehabilitation program after an OI implant includes a specific training period with a short training prosthesis. Since mechanical loading is considered to be one of the key factors that influence bone mass and the osseointegration of bone-anchored implants, the rehabilitation program will also need to include some form of load bearing exercises (LBE). To date there are two frequently used commercially available human implants. We can find proof in the literature that load bearing exercises are performed by patients with both types of OI implants. We refer to two articles, a first one written by Dr. Aschoff and all and published in 2010 in the Journal of Bone and Joint Surgery.[2] The second one presented by Hagberg et al in 2009 gives a very thorough description of the rehabilitation program of TFA fitted with an OPRA implant. The progression of the load however is determined individually according to the residual skeleton’s quality, pain level and body weight of the participant.[1] Patients are using a classical bathroom weighing scale to control the load on the implant during the course of their rehabilitation. The bathroom scale is an affordable and easy-to-use device but it has some important shortcomings. The scale provides instantaneous feedback to the patient only on the magnitude of the vertical component of the applied force. The forces and moments applied along and around the three axes of the implant are unknown. Although there are different ways to assess the load on the implant for instance through inverse dynamics in a motion analysis laboratory [3-6] this assessment is challenging. A recent proof- of-concept study by Frossard et al (2009) showed that the shortcomings of the weighing scale can be overcome by a portable kinetic system based on a commercial transducer[7].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were (A) to record the inner prosthesis loading during activities of daily living (ADL), (B) to present a set of variables comparing loading data, and (C) to provide an example of characterisation of two prostheses. The load was measured at 200 Hz using a multi-axial transducer mounted between the residuum and the knee of an individual with unilateral transfemoral amputation fitted with a bone-anchored prosthesis. The load was measured while using two different prostheses including a mechanically (PRO1) and a microprocessor controlled (PRO2) knee during six ADL. The characterisation of prosthesis was achieved using a set of variables split into four categories, including temporal characteristics, maximum loading, loading slopes and impulse. Approximately 360 gait cycles were analysed for each prosthesis. PRO1 showed a cadence improved by 19% and 7%, a maximum force on the long axis reduced by 11% and 19%, as well as an impulse reduced by 32% and 15% during descent of incline and stairs compared to PRO2, respectively. This work confirmed that the proposed apparatus and characterisation can reveal how changes of prosthetic components are translated into inner loading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed at presenting the intra-tester reliability of the static load bearing exercises (LBEs) performed by individuals with transfemoral amputation (TFA) fitted with an osseointegrated implant to stimulate the bone remodelling process. There is a need for a better understanding of the implementation of these exercises particularly the reliability. The intra-tester reliability is discussed with a particular emphasis on inter-load prescribed, inter-axis and inter-component reliabilities as well as the effect of body weight normalisation. Eleven unilateral TFAs fitted with an OPRA implant performed five trials in four loading conditions. The forces and moments on the three axes of the implant were measured directly with an instrumented pylon including a six-channel transducer. Reliability of loading variables was assessed using intraclass correlation coefficients (ICCs) and percentage standard error of measurement values (%SEMs). The ICCs of all variables were above 0.9 and the %SEM values ranged between 0 and 87%. This study showed a high between-participants’ variance highlighting the lack of loading consistency typical of symptomatic population as well as a high reliability between the loading sessions indicating a plausible correct repetition of the LBE by the participants. However, these outcomes must be understood within the framework of the proposed experimental protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The risk for late periprosthetic femoral fractures is higher in patients treated for a neck of femur fracture compared to osteoarthritis. It has been hypothesised that osteopenia and consequent decreased stiffness of the proximal femur are responsible for this. We investigated whether a femoral component with a bigger body would increase the torque to failure in a biaxially loaded composite Sawbone model. Material and methods: A biomechanical bone analogue was used. Two different body sizes (Exeter 44-1 vs 44-4) of a polished tapered cemented femoral stem were implanted by an experienced surgeon in 7 bone analogues each and internally rotated at 40°/s until failure. Torque to fracture and fracture energy were measured using a biaxial materials testing device (Instron 8874, MI, USA). The data were non-parametric and therefore tested with the Mann-Whitney U-test. Results: The median torque to fracture was 156.7 Nm (IQR 19.7) for the 44-1 stem and 237.1 Nm (IQR 52.9) for the 44-4 stem (p=0.001). The median fracture energy was 8.5J (IQR 7.3) for the 44-1 stem and 19.5J (IQR 8.8) for the 44-4 stem (p=0.014). Conclusions: The use of a large body polished tapered cemented stems for neck of femur fractures increases the torque to failure in a biomechanical model and therefore is likely to reduce late periprosthetic fracture risk in this vulnerable cohort.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present contribution deals with the numerical modelling of railway track-supporting systems-using coupled finite-infinite elements-to represent the near and distant field stress distribution, and also employing a thin layer interface element to account for the interfacial behaviour between sleepers and ballast. To simulate the relative debonding, slipping and crushing at the contact area between sleepers and ballast, a modified Mohr-Coulomb criterion was adopted. Further more an attempt was made to consider the elasto plastic materials’ non-linearity of the railway track supporting media by employing different constitutive models to represent steel, concrete and other supporting materials. It is seen that during an incremental-iterative mode of load application, the yielding initially started from the edge of the sleepers and then flowed vertically downwards and spread towards the centre of the railway supporting system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: It is important for nutrition intervention in malnourished patients to be guided by accurate evaluation and detection of small changes in the patient’s nutrition status over time. However, the current Subjective Global Assessment (SGA) is not able to detect changes in a short period of time. The aim of the study was to determine whether 7-point SGA is more time sensitive to nutrition changes than the conventional SGA. Methods: In this prospective study, 67 adult inpatients assessed as malnourished using both the 7-point SGA and conventional SGA were recruited. Each patient received nutrition intervention and was followed up post-discharge. Patients were reassessed using both tools at 1, 3 and 5 months from baseline assessment. Results: It took significantly shorter time to see a one-point change using 7-point SGA compared to conventional SGA (median: 1 month vs. 3 months, p = 0.002). The likelihood of at least a one-point change is 6.74 times greater in 7-point SGA compared to conventional SGA after controlling for age, gender and medical specialties (odds ratio = 6.74, 95% CI 2.88-15.80, p<0.001). Fifty-six percent of patients who had no change in SGA score had changes detected using 7-point SGA. The level of agreement was 100% (k = 1, p < 0.001) between 7-point SGA and 3-point SGA and 83% (k=0.726, p<0.001) between two blinded assessors for 7-point SGA. Conclusion: The 7-point SGA is more time sensitive in its response to nutrition changes than conventional SGA. It can be used to guide nutrition intervention for patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses the issue of sensing and control for stabilizing a swinging load. Our work has focused in particular on the dragline as used for overburden stripping in open-pit coal mining, but many of the principles would also be applicable to construction cranes. Results obtained from experimental work on a full-scale production dragline are presented.