951 resultados para air-liquid interface
Resumo:
This work reports a recently developed electro-optical (EO) device that can potentially be used as a light shutter or a privacy window. By using nanocrystalline cellulose rods, we were able to improve some of the most relevant parameters characterising the EO behaviour. A brief description of the proposed working mechanism for these devices is presented, and numerical simulations based on this mechanism of both the optical transmission and the cells' electrical capacitance are compared with the obtained results, validating the underlying working model considered.
Resumo:
Water-based cellulose cholesteric liquid crystalline phases at rest can undergo structural changes induced by shear flow. This reflects on the deuterium spectra recorded when the system is investigated by rheo-nuclear magnetic resonance (rheo-NMR) techniques. In this work, the model system hydroxypropylcellulose (HPC)+water is revisited using rheo-NMR to clarify unsettled points regarding its behavior under shear and in relaxation. The NMR spectra allow the identification of five different stable ordering states, within shear and relaxation, which are well integrated in a mesoscopic picture of the system's structural evolution under shear and relaxation. This picture emerging from the large body of studies available for this system by other experimental techniques, accounts well for the NMR data and is in good agreement with the three distinct regions of steady shear flow recognized for some lyotropic LC polymers. Shear rates in between 0.1 and 1.0 s(-1) where investigated using a Taylor-Couette flow and deuterated water was used as solvent for the deuterium NMR (DNMR) analysis.
Resumo:
Relevant past events can be remembered when visualizing related pictures. The main difficulty is how to find these photos in a large personal collection. Query definition and image annotation are key issues to overcome this problem. The former is relevant due to the diversity of the clues provided by our memory when recovering a past moment and the later because images need to be annotated with information regarding those clues to be retrieved. Consequently, tools to recover past memories should deal carefully with these two tasks. This paper describes a user interface designed to explore pictures from personal memories. Users can query the media collection in several ways and for this reason an iconic visual language to define queries is proposed. Automatic and semi-automatic annotation is also performed using the image content and the audio information obtained when users show their images to others. The paper also presents the user interface evaluation based on tests with 58 participants.
Resumo:
Throughout the world, epidemiological studies were established to examine the relationship between air pollution and mortality rates and adverse respiratory health effects. However, despite the years of discussion the correlation between adverse health effects and atmospheric pollution remains controversial, partly because these studies are frequently restricted to small and well-monitored areas. Monitoring air pollution is complex due to the large spatial and temporal variations of pollution phenomena, the high costs of recording instruments, and the low sampling density of a purely instrumental approach. Therefore, together with the traditional instrumental monitoring, bioindication techniques allow for the mapping of pollution effects over wide areas with a high sampling density. In this study, instrumental and biomonitoring techniques were integrated to support an epidemiological study that will be developed in an industrial area located in Gijon in the coastal of central Asturias, Spain. Three main objectives were proposed to (i) analyze temporal patterns of PM10 concentrations in order to apportion emissions sources, (ii) investigate spatial patterns of lichen conductivity to identify the impact of the studied industrial area in air quality, and (iii) establish relationships amongst lichen conductivity with some site-specific characteristics. Samples of the epiphytic lichen Parmelia sulcata were transplanted in a grid of 18 by 20 km with an industrial area in the center. Lichens were exposed for a 5-mo period starting in April 2010. After exposure, lichen samples were soaked in 18-MΩ water aimed at determination of water electrical conductivity and, consequently, lichen vitality and cell damage. A marked decreasing gradient of lichens conductivity relative to distance from the emitting sources was observed. Transplants from a sampling site proximal to the industrial area reached values 10-fold higher than levels far from it. This finding showed that lichens reacted physiologically in the polluted industrial area as evidenced by increased conductivity correlated to contamination level. The integration of temporal PM10 measurements and analysis of wind direction corroborated the importance of this industrialized region for air quality measurements and identified the relevance of traffic for the urban area.
Resumo:
This project was developed to fully assess the indoor air quality in archives and libraries from a fungal flora point of view. It uses classical methodologies such as traditional culture media – for the viable fungi – and modern molecular biology protocols, especially relevant to assess the non-viable fraction of the biological contaminants. Denaturing high-performance liquid chromatography (DHPLC) has emerged as an alternative to denaturing gradient gel electrophoresis (DGGE) and has already been applied to the study of a few bacterial communities. We propose the application of DHPLC to the study of fungal colonization on paper-based archive materials. This technology allows for the identification of each component of a mixture of fungi based on their genetic variation. In a highly complex mixture of microbial DNA this method can be used simply to study the population dynamics, and it also allows for sample fraction collection, which can, in many cases, be immediately sequenced, circumventing the need for cloning. Some examples of the methodological application are shown. Also applied is fragment length analysis for the study of mixed Candida samples. Both of these methods can later be applied in various fields, such as clinical and sand sample analysis. So far, the environmental analyses have been extremely useful to determine potentially pathogenic/toxinogenic fungi such as Stachybotrys sp., Aspergillus niger, Aspergillus fumigatus, and Fusarium sp. This work will hopefully lead to more accurate evaluation of environmental conditions for both human health and the preservation of documents.
Resumo:
Mestrado em Engenharia Química.Ramo Tecnologias de Protecção Ambiental
Resumo:
Mestrado em Engenharia Informática. Área de Especialização em Tecnologias do Conhecimento e Decisão.
Resumo:
Actualmente, a poluição do ar, água e solo são problemáticas nas quais se têm centrado diversos estudos. Reduzir ou eliminar a concentração dos diversos poluentes presentes nestes meios é uma meta que se pretende atingir. Neste âmbito, têm sido desenvolvidos diversos estudos e trabalhos, utilizando diversas tecnologias, como químicas e biológicas, de forma a conseguir-se atingir este fim. Esta tese teve como principal objectivo estudar a remediação de solos contaminados com produtos farmacêuticos recorrendo à oxidação/redução química. Assim, começou por se estudar a remediação de água contaminada com ibuprofeno, uma vez, que a matriz líquida é mais fácil de estudar que o solo. Neste âmbito escolheram-se os seguintes reagentes para estudar a descontaminação da água: permanganato de potássio, reagente de Fenton e nanopartículas de ferro zero valente. Analisando os resultados obtidos nestas análises, verificou-se que o permanganato de potássio não foi capaz de reduzir a concentração de ibuprofeno presente na água. No entanto, o reagente de Fenton e as nanopartículas produzidas a partir do extracto da casca de castanha e do chá conseguirem reagir com o ibuprofeno, apresentando taxas de degradação de 90 % e 77 %, respectivamente, nas melhores condições experimentadas. Com os resultados obtidos, passou-se a analisar solos contaminados com o ibuprofeno, utilizando o reagente de Fenton e as nanopartículas produzidas a partir de um extracto de chá. Verificou-se que estes reagentes conseguiram reduzir a concentração de ibuprofeno presente no solo (areia) para valores residuais, obtendo-se taxas de degradação acima de 95 % após 5 dias de reacção. Conclui-se que, o objectivo principal desta tese foi cumprido pois foi reduzida, e quase eliminada, a concentração do ibuprofeno presente no solo, recorrendo à oxidação/redução química.
Resumo:
Thesis submitted in the fulfilment of the requirements for the Degree of Master in Electronic and Telecomunications Engineering
Resumo:
No trabalho realizado nesta tese, procedeu-se ao estudo hidrodinâmico de uma
coluna de borbulhamento de recirculação externa do líquido (CREL), que permitiu ampliar o
conhecimento já existente sobre este tipo de colunas. Para realizar este estudo utilizaram-se
líquidos viscosos Newtonianos, nomeadamente soluções aquosas de glicerina com
viscosidades entre 0,007 e 0,522 Pa.s. Para a gama de caudais de ar injectados, 1,5x10-5
até 1,35x10-4 m3/s, o ar ascendia ao longo da coluna de borbulhamento sob a forma de
bolhas tubulares. Após a realização dos ensaios, verificou-se que o regime de escoamento
do líquido entre bolhas tubulares variou desde o tipo laminar até transição (1,9
Resumo:
The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.
Resumo:
Grande parte dos triples-stores são open source e desenvolvidos em Java, disponibilizando interfaces standards e privadas de acesso. A grande maioria destes sistemas não dispõe de mecanismos de controlo de acessos nativos, o que dificulta ou impossibilita a sua adopção em ambientes em que a segurança dos factos é importante (e.g. ambiente empresarial). Complementarmente observa-se que o modelo de controlo de acesso a triplos e em particular a triplos descritos por ontologias não está standardizado nem sequer estabilizado, havendo diversos modelos de descrição e algoritmos de avaliação de permissões de acesso. O trabalho desenvolvido nesta tese/dissertação propõe um modelo e interface de controlo de acesso que permite e facilite a sua adopção por diferentes triple-stores já existentes e a integração dos triples-stores com outros sistemas já existentes na organização. Complementarmente, a plataforma de controlo de acesso não impõe qualquer modelo ou algoritmo de avaliação de permissões, mas pelo contrário permite a adopção de modelos e algoritmos distintos em função das necessidades ou desejos. Finalmente demonstra-se a aplicabilidade e validade do modelo e interface propostos, através da sua implementação e adopção ao triple-store SwiftOWLIM já existente, que não dispõe de mecanismo de controlo de acessos nativo.
Resumo:
O intuito principal desta Tese é criar um interface de Dados entre uma fonte de informação e fornecimento de Rotas para turistas e disponibilizar essa informação através de um sistema móvel interactivo de navegação e visualização desses mesmos dados. O formato tecnológico será portátil e orientado à mobilidade (PDA) e deverá ser prático, intuitivo e multi-facetado, permitindo boa usabilidade a públicos de várias faixas etárias. Haverá uma componente de IA (Inteligência Artificial), que irá usar a informação fornecida para tomar decisões ponderadas tendo em conta uma diversidade de aspectos. O Sistema a desenvolver deverá ser, assim, capaz de lidar com imponderáveis (alterações de rota, gestão de horários, cancelamento de pontos de visita, novos pontos de visita) e, finalmente, deverá ajudar o turista a gerir o seu tempo entre Pontos de Interesse (POI – Points os Interest). Deverá também permitir seguir ou não um dado percurso pré-definido, havendo possibilidade de cenários de exploração de POIs, sugeridos a partir de sugestões in loco, similares a Locais incluídos no trajecto, que se enquadravam no perfil dos Utilizadores. O âmbito geográfico de teste deste projecto será a zona ribeirinha do porto, por ser um ex-líbris da cidade e, simultaneamente, uma zona com muitos desafios ao nível geográfico (com a inclinação) e ao nível do grande número de Eventos e Locais a visitar.
Resumo:
Com a generalização das tecnologias de informação e comunicação na área da saúde, a monitorização remota de pacientes, a partir de dispositivos móveis, é uma realidade que contribui para uma melhor qualidade de vida dos pacientes. Mas, não são só os pacientes que ganham com a introdução destas tecnologias, também os profissionais de saúde e os hospitais retiram as suas vantagens. Os profissionais de saúde são munidos de uma ferramenta móvel de monitorização permanente de sinais vitais, aumentando desta forma a ligação médico-paciente. Relativamente aos hospitais, estes vêem os custos de manutenção reduzirem, em virtude da possibilidade dos pacientes puderem ser monitorizados a partir dos seus lares. Neste projecto pretende-se identificar mecanismos que possibilitem responder de forma eficaz à necessidade de partilha de informação, nomeadamente protocolos de comunicação, segurança e sistemas de integração. Foi projectado um protótipo, constituído por um middleware e uma aplicação cliente móvel, onde o middleware tem como missão garantir a interoperabilidade entre um servidor HL7 e a aplicação cliente, utilizada pelo profissional de saúde. A normalização da informação médica trocada entre o servidor HL7 e o middleware obedece à norma internacional HL7.
Resumo:
Web tornou-se uma ferramenta indispensável para a sociedade moderna. A capacidade de aceder a enormes quantidades de informação, disponível em praticamente todo o mundo, é uma grande vantagem para as nossas vidas. No entanto, a quantidade avassaladora de informação disponível torna-se um problema, que é o de encontrar a informação que precisamos no meio de muita informação irrelevante. Para nos ajudar nesta tarefa, foram criados poderosos motores de pesquisa online, que esquadrinham a Web à procura dos melhores resultados, segundo os seus critérios, para os dados que precisamos. Actualmente, os motores de pesquisa em voga, usam um formato de apresentação de resultados simples, que consiste apenas numa caixa de texto para o utilizador inserir as palavras-chave sobre o tema que quer pesquisar e os resultados são dispostos sobre uma lista de hiperligações ordenada pela relevância que o motor atribui a cada resultado. Porém, existem outras formas de apresentar resultados. Uma das alternativas é apresentar os resultados sobre interfaces em 3 dimensões. É nestes tipos de sistemas que este trabalho vai incidir, os motores de pesquisa com interfaces em 3 dimensões. O problema é que as páginas Web não estão preparadas para serem consumidas por este tipo de motores de pesquisa. Para resolver este problema foi construído um modelo generalista para páginas Web, que consegue alimentar os requisitos das diversas variantes destes motores de pesquisa. Foi também desenvolvido um protótipo de instanciação automático, que recolhe as informações necessárias das páginas Web e preenche o modelo.