921 resultados para Three-phase line analysis
Resumo:
The study proposes an understanding of nurses training in reflexivity and the overcome the limits of biomedical formation model, from the thought of John Dewey, inserted in the panorama of the reflective practitioner introduced by Donald Schön and dialoguing with the perspective of the transforming action of Paulo Freire. We used a qualitative approach to collect empirical data through focus groups conducted with nursing students from 3rd to 5th year in the Faculty of Health Sciences, Trairi / UFRN in the year 2012. Data analysis occurred through the technique of thematic content analysis constituted of three stages: pre-analysis, exploration of the material, treatment of results, inference and interpretation of the material. Thus, the categories formulated by organizing, classifying and aggregating the the content of the speeches to groups who shared opinions approximations of thought generating a set of categories of analysis designed from the contents. The results present the experiences of nursing students and their reflections, demonstrating that the process of reflection permeates the journey of life. It is inferred that the knowledge acquired in these experiences do not always participate in this dialogue in this formative process, reducing previous experiences in the field of exemplification of everyday situations. We conclude that it is necessary to consolidate innovative pedagogical proposals that allow the continuous dialogue with reality, breaking with the decontextualized teaching process from reality insertion of the university. Rethinking of the structures is recommended, reinforcing the break with the biomedical model and the integration of knowledge dynamically
Resumo:
At present, the Brazilian market prefers cabbage (Brassica oleracea var. capitata) of smaller size, which can be achieved by increasing population density; yet this management can alter the optimum rate of nitrogen (N), its second most required nutrient. This study was conducted in the Universidade Estadual Paulista, Jaboticabal, São Paulo, Brazil, from February to June 2004. The objective was to evaluate the effect of population density: 31 250 (DI) and 46 875 plants ha(-1) (D2) with 0, 100, 200 and 300 kg N ha-1 on the growth and production of cabbage Astrus. The experimental design consisted of randomized blocks with a 2 x 4 factorial arrangement and three replicates. Statistical analysis were a variance analysis (F test), the Tukey test for population density averages and polynomial regression for the N rates. In D1, an increase was recorded in the number of inner and outer leaves, dry matter of inner and outer leaves, the stem diameter at the insertion of the head, and the stem dry and fresh matter. The maximum size of the plant in D2 was 1.57 kg and was obtained with 300 kg N ha(-1), while in D1 it was 2.1 kg and was obtained with 244 kg N ha(-1). The optimal economic rate in 131 was 227.1 kg N ha(-1). The highest yield (72.7 t ha(-1)) was obtained with the highest N rate in D2. Smaller cabbage heads, commercially preferred, were obtained without the application of N, regardless of plant population.
Resumo:
The studies paths in the maze: life story of individuals with oncological diseases into use of blood transfusion in Natal has the hemotherapy as a primordial procedure to review the relationship between users of oncological health and the due ramifications. The hemotherapy looks for supply the organic needs through blood transfusion, which acquires vital function to the ones that have cancer, because it might reestablish the functionality of the organism throughout the raising of blood components. The impact over the transfusion affects emotionally and physically the users life. Aiming to reflect on these impacts, this study tried, through narratives of lives, rescue their experience since their knowledge of the disease until the time of blood transfusion using. It s about an exploratory-descriptive study, where the qualitative approach uses the theoretical-methodological reference of the oral life history to analyze a colony consisting of five users of health diagnosed with cancer, with achievement of at least three blood transfusions, the clinic Núcleo de Hematologia e Hemoterapia - UFRN, in Natal-RN. The network, in turn, was composed by employees of both sexes, regardless of age, who voluntarily agreed to participate in the study. The data collection, with approval of the Ethics Committee in Research, Liga Norte Riograndense Contra o Cancer, on the number 001/001/2012, occurred through semi-structured interviews, recorded individually in the home context that was previously chosen by employees. The methodological procedure occurred with the transcription of the interviews and their transcreations, and analysis of reports by thematic content analysis. At the reading orientation and interpretation of the employees stories, were discussed three categories of analysis: the impact on psychological REVIEW; impact on socialization and group membership, the environment and the impact of blood transfusion on treatment. Based on the narrative of the life histories of employees, we conclude that the experiences and feelings, hope and sorrow, pain and faith, even when facing a disease like cancer, bring lots of teaching and learning to health professional that deposits humanization health and reinstate hemotherapy forms of clinical critical
Resumo:
This work describes the study and the implementation of the vector speed control for a three-phase Bearingless induction machine with divided winding of 4 poles and 1,1 kW using the neural rotor flux estimation. The vector speed control operates together with the radial positioning controllers and with the winding currents controllers of the stator phases. For the radial positioning, the forces controlled by the internal machine magnetic fields are used. For the radial forces optimization , a special rotor winding with independent circuits which allows a low rotational torque influence was used. The neural flux estimation applied to the vector speed controls has the objective of compensating the parameter dependences of the conventional estimators in relation to the parameter machine s variations due to the temperature increases or due to the rotor magnetic saturation. The implemented control system allows a direct comparison between the respective responses of the speed and radial positioning controllers to the machine oriented by the neural rotor flux estimator in relation to the conventional flux estimator. All the system control is executed by a program developed in the ANSI C language. The DSP resources used by the system are: the Analog/Digital channels converters, the PWM outputs and the parallel and RS-232 serial interfaces, which are responsible, respectively, by the DSP programming and the data capture through the supervisory system
Resumo:
In this work, the variable structure adaptive pole placement controller (VS-APPC) robustness and performance are evaluated and this algorithm is applied in a motor control system. The controller robustness evaluation will be done through simulations, where will be introduced in the system the following adversities: time delay, actuator response boundeds, disturbances, parametric variation and unmodeled dynamics. The VS-APPC will be compared with PI control, pole placement control (PPC) and adaptive pole placement controller (APPC). The VS-APPC will be simulated to track a step and a sine reference. It will be applied in a three-phase induction motor control system to track a sine signal in the stator reference frame. Simulation and experimental results will prove the efficiency and robustness of this control strategy
Resumo:
This work describes the study and the implementation of the speed control for a three-phase induction motor of 1,1 kW and 4 poles using the neural rotor flux estimation. The vector speed control operates together with the winding currents controller of the stator phasis. The neural flux estimation applied to the vector speed controls has the objective of compensating the parameter dependences of the conventional estimators in relation to the parameter machine s variations due to the temperature increases or due to the rotor magnetic saturation. The implemented control system allows a direct comparison between the respective responses of the speed controls to the machine oriented by the neural rotor flux estimator in relation to the conventional flux estimator. All the system control is executed by a program developed in the ANSI C language. The main DSP recources used by the system are, respectively, the Analog/Digital channels converters, the PWM outputs and the parallel and RS-232 serial interfaces, which are responsible, respectively, by the DSP programming and the data capture through the supervisory system
Resumo:
This work presents a proposal for a voltage and frequency control system for a wind power induction generator. It has been developed na experimental structure composes basically by a three phase induction machine, a three phase capacitor and a reactive static Power compensator controlled by histeresys. lt has been developed control algorithms using conventional methods (Pl control) and linguistic methods (using concepts of logic and fuzzy control), to compare their performances in the variable speed generator system. The control loop was projected using the ADJDA PCL 818 model board into a Pentium 200 MHz compu ter. The induction generator mathematical model was studied throught Park transformation. It has been realized simulations in the Pspice@ software, to verify the system characteristics in transient and steady-state situations. The real time control program was developed in C language, possibilish verify the algorithm performance in the 2,2kW didatic experimental system
Resumo:
This work deals with the development of an experimental study on a power supply of high frequency that provides the toch plasmica to be implemented in PLASPETRO project, which consists of two static converters developed by using Insulated Gate Bipolar Transistor (IGBT). The drivers used to control these keys are triggered by Digital Signal Processor (DSP) through optical fibers to reduce problems with electromagnetic interference (EMI). The first stage consists of a pre-regulator in the form of an AC to DC converter with three-phase boost power factor correction which is the main theme of this work, while the second is the source of high frequency itself. A series-resonant inverter consists of four (4) cell inverters operating in a frequency around 115 kHz each one in soft switching mode, alternating itself to supply the load (plasma torch) an alternating current with a frequency of 450 kHz. The first stage has the function of providing the series-resonant inverter a DC voltage, with the value controlled from the power supply provided by the electrical system of the utility, and correct the power factor of the system as a whole. This level of DC bus voltage at the output of the first stage will be used to control the power transferred by the inverter to the load, and it may vary from 550 VDC to a maximum of 800 VDC. To control the voltage level of DC bus driver used a proportional integral (PI) controller and to achieve the unity power factor it was used two other proportional integral currents controllers. Computational simulations were performed to assist in sizing and forecasting performance. All the control and communications needed to stage supervisory were implemented on a DSP
Resumo:
The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using a prototype three-phase active filter of 1 kVA
Resumo:
This work describes the experimental implementation of a shunt active power filter applied to a three-phase induction generator. The control strategy of active filter turned to the excitation control of the machine and to decrease the harmonics in the generator output current. Involved the implementation of a digital PWM switching, and was made a comparison of two techniques for obtaining the reference currents. The first technique is based on the synchronous dq reference method and the second on the theory of instantaneous power. The comparison is performed via simulation and experimental results. To obtain the experimental results, was mounted a bench trial and the control and communications needed were implemented using DSP - MS320F2812. The simulation results and experimental data proved the efficiency of the filter to apply, highlighting the technique of instantaneous power
Resumo:
This work presents a diagnosis faults system (rotor, stator, and contamination) of three-phase induction motor through equivalent circuit parameters and using techniques patterns recognition. The technology fault diagnostics in engines are evolving and becoming increasingly important in the field of electrical machinery. The neural networks have the ability to classify non-linear relationships between signals through the patterns identification of signals related. It is carried out induction motor´s simulations through the program Matlab R & Simulink R , and produced some faults from modifications in the equivalent circuit parameters. A system is implemented with multiples classifying neural network two neural networks to receive these results and, after well-trained, to accomplish the identification of fault´s pattern
Resumo:
There are two main approaches for using in adaptive controllers. One is the so-called model reference adaptive control (MRAC), and the other is the so-called adaptive pole placement control (APPC). In MRAC, a reference model is chosen to generate the desired trajectory that the plant output has to follow, and it can require cancellation of the plant zeros. Due to its flexibility in choosing the controller design methodology (state feedback, compensator design, linear quadratic, etc.) and the adaptive law (least squares, gradient, etc.), the APPC is the most general type of adaptive control. Traditionally, it has been developed in an indirect approach and, as an advantage, it may be applied to non-minimum phase plants, because do not involve plant zero-pole cancellations. The integration to variable structure systems allows to aggregate fast transient and robustness to parametric uncertainties and disturbances, as well. In this work, a variable structure adaptive pole placement control (VS-APPC) is proposed. Therefore, new switching laws are proposed, instead of using the traditional integral adaptive laws. Additionally, simulation results for an unstable first order system and simulation and practical results for a three-phase induction motor are shown
Resumo:
The present work shows the development and construction of a robot manipulator with two rotary joints and two degrees of freedom, driven by three-phase induction motors. The positions of the arm and base are made, for comparison, by a fuzzy controller and a PID controller implemented in LabVIEW® programming environment. The robot manipulator moves in an area equivalent to a quarter of a sphere. Experimental results have shown that the fuzzy controller has superior performance to PID controller when tracking single and multiple step trajectories, for the cases of load and no load
Resumo:
The organic matter. (OM) removal efficiency in the biochemical oxygen demand (BOD) and chemical oxygen demand (COD) forms for domestic wastewater and semi-intensive fish culture effluents by using three phase aerobic fluidized bed reactors with circulation in concentric tubes was studied. Three different ratios between external and internal areas by different internal diameter configurations (100, 125 and 150mm) to the same external diameter of 250mm were used; sand for filters and granulated activated carbon were used as supporting media. The reactors were tested for three hydraulic retention times: 11.5min to the R100, and 3h for the R125 and R150 reactors. The results demonstrated that this kind of reactors had good performance in the BOD and COD removal for different concentrations of waste waters. BOD mean removal efficiencies obtained were: 47% at the R100 reactor, 57% and 93% of raw and filtered BOD respectively at R125, 48 and 89% of raw and filtered BOD at R150. The COD mean calculated removal efficiencies were: 75% at the R100 reactor, 56 and 86% of raw and filtered COD at R125, and 54 and 86% of raw and filtered COD at R150. In the case of domestic wastewater it is necessary to provide a solids removal system at the reactor outflow in order to increase the removal of suspended OM from the final effluent.
Resumo:
O objetivo deste trabalho foi monitorar o desempenho de remoção de nitrogênio amoniacal no tratamento das águas residuárias da produção intensiva de tilápia nilótica em sistema com recirculação de água. O sistema foi constituído por um sedimentador convencional e um reator aeróbio de leito fluidizado trifásico com circulação, operados com tempos de detenção hidráulica de 176.4 e 11.9 minutos respectivamente. O meio suporte utilizado no reator foi o carvão ativado granular com densidade aparente de 1.64 g/cm3 e tamanho efetivo de 0.34 mm; a concentração do meio suporte no reator foi mantida constante em 80 g/L. A eficiência média de remoção do nitrogênio amoniacal total foi de 41.2%. O sistema avaliado é uma alternativa efetiva para o reuso da água em sistemas de recirculação para aqüicultura. Embora a variabilidade das concentrações do nitrogênio amoniacal afluente cujo valor médio foi de 0.136 mg/L, o efluente do reator conservou as características de qualidade da água estáveis, com concentrações médias de nitrogênio amoniacal de 0.079 mg/L e do oxigênio dissolvido de 6.70 mg/L, recomendáveis para a criação dos peixes e nas faixas de valores permitidos pela legislação Brasileira (Resolução CONAMA No. 357 de março 5 de 2005) para lançamento de efluentes finais nos corpos de água receptores.