954 resultados para Septic Tank


Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT: The CIAO Study ("Complicated Intra-Abdominal infection Observational" Study) is a multicenter investigation performed in 68 medical institutions throughout Europe over the course of a 6-month observational period (January-June 2012).Patients with either community-acquired or healthcare-associated complicated intra-abdominal infections (IAIs) were included in the study.2,152 patients with a mean age of 53.8 years (range: 4-98 years) were enrolled in the study. 46.3% of the patients were women and 53.7% were men. Intraperitoneal specimens were collected from 62.2% of the enrolled patients, and from these samples, a variety of microorganisms were collectively identified.The overall mortality rate was 7.5% (163/2.152).According to multivariate analysis of the compiled data, several criteria were found to be independent variables predictive of patient mortality, including patient age, the presence of an intestinal non-appendicular source of infection (colonic non-diverticular perforation, complicated diverticulitis, small bowel perforation), a delayed initial intervention (a delay exceeding 24 hours), sepsis and septic shock in the immediate post-operative period, and ICU admission.Given the sweeping geographical distribution of the participating medical centers, the CIAO Study gives an accurate description of the epidemiological, clinical, microbiological, and treatment profiles of complicated intra-abdominal infections (IAIs) throughout Europe.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Controversy still exists as to the best surgical treatment for periprosthetic shoulder infections. The aim of this multi-institutional study was to review a continuous retrospective series of patients treated in four European centres and to assess the respective eradication rate of various treatment approaches. METHODS: Forty-four patients were available for this retrospective follow-up evaluation. Functional and clinical evaluation of treatment for infection was performed using the Constant-Murley score, visual analogue scale and patient satisfaction Neer score. Erythrocyte sedimentation rate, serum leucocyte count and C-reactive protein were measured and shoulder X-ray examination performed prior to surgery and at the latest follow-up. RESULTS: At a mean follow-up of 41 months (range 24-98), 42 of 44 patients (95.5%) showed no signs of infection recurrence/persistence. Comparable eradication rates were observed after resection arthroplasty (100%; 6/6), two-stage revision (17/17) or permanent antibiotic-loaded spacer implant (93.3%; 14/15). No patient was treated by one-stage revision. On average, both functional and pain scores improved significantly; the worst joint function was observed after resection arthroplasty. CONCLUSIONS: This retrospective analysis conducted on the largest published series of patients to date shows comparable infection eradication rates after two-stage revision, resection arthroplasty or permanent spacer implant for the treatment of septic shoulder prosthesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabajo final de carrera se basa en la redacción de un proyecto de ejecución de una zona lúdica situada en el interior del recinto de un camping, la cual estará formada por una piscina de grandes dimensiones formada por tres vasos de tipo desbordante, una piscina de tipo infantil, un jacuzzi y finalmente un edificio de servicios complementarios (bar, aseos y enfermería). La piscina grande estará formada por tres vasos donde el agua va deslizándose de uno a otro hasta ser recogida por un depósito de compensación desde donde se realizará la filtración y tratamiento antes de ser devuelta al piscina de nuevo. La instalación está también preparada para ser utilizado cada vaso como una piscina individual, recogiendo el agua por los rebosaderos laterales y conduciéndola al mismo vaso de compensación. El tratamiento del agua se realizará de forma física a través de la filtración mediante filtros de arena y de forma química analizando la cantidad de cloro residual y el nivel de PH y posteriormente añadiendo de forma automática las cantidades de cloro y corrector de PH adecuados mediante bombas dosificadoras de precisión. La piscina infantil es de pequeñas dimensiones y esta preparada para ser utilizada por niños de muy corta edad. Se diferencia de la piscina grande en el sistema de recirculación de agua (en este casos e utilizarán skimmers) y en el tratamiento posterior, ya que se utilizará el sistema de hidrólisis salina para su desinfección en lugar de añadir directamente cloro. Este sistema de tratamiento del agua no es tan agresivo como el tradicional, siendo cada vez mas utilizado en piscinas de mediano y pequeño tamaño. El jacuzzi es de grandes dimensiones, disponiendo de su propio sistema de tratamiento de agua, utilizando el sistema de hidrólisis salina como en el caso de la piscina infantil. El edificio de servicios dispone de zonas de bar, enfermería y aseos. Se ha descrito desde la estructura a las instalaciones, justificando las conclusiones a través de los cálculos correspondientes, bien de forma manual, bien utilizando diverso software especializado.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In patients suffering from sickle cell disease (SCD), bone is a preferred site of infection. We report the case of a five-year-and-eight-month-old black African boy with homozygous-SS disease who developed a cranial epidural abscess. This intracranial infectious complication originated from a Salmonella enteritidis osteitis of the frontal bone. Antibiotic treatment alone did not control the disease, so surgery was necessary to remove the necrotic bone and to evacuate the epidural pus. The numerous factors interfering with normal healing of a septic focus in sickle cell anemia, particularly in this previously undescribed intracranial complication, emphasize the need for a primary and early surgical treatment in similar situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the survival benefit and safety profile of low-dose (850 mg/kg) and high-dose (1350 mg/kg) phospholipid emulsion vs. placebo administered as a continuous 3-day infusion in patients with confirmed or suspected Gram-negative severe sepsis. Preclinical and ex vivo studies show that lipoproteins bind and neutralize endotoxin, and experimental animal studies demonstrate protection from septic death when lipoproteins are administered. Endotoxin neutralization correlates with the amount of phospholipid in the lipoprotein particles. DESIGN: A three-arm, randomized, blinded, placebo-controlled trial. SETTING: Conducted at 235 centers worldwide between September 2004 and April 2006. PATIENTS: A total of 1379 patients participated in the study, 598 patients received low-dose phospholipid emulsion, and 599 patients received placebo. The high-dose phospholipid emulsion arm was stopped, on the recommendation of the Independent Data Monitoring Committee, due to an increase in life-threatening serious adverse events at the fourth interim analysis and included 182 patients. MEASUREMENTS AND MAIN RESULTS: A 28-day all-cause mortality and new-onset organ failure. There was no significant treatment benefit for low- or high-dose phospholipid emulsion vs. placebo for 28-day all-cause mortality, with rates of 25.8% (p = .329), 31.3% (p = .879), and 26.9%, respectively. The rate of new-onset organ failure was not statistically different among groups at 26.3%, 31.3%, 20.4% with low- and high-dose phospholipid emulsion, and placebo, respectively (one-sided p = .992, low vs. placebo; p = .999, high vs. placebo). Of the subjects treated, 45% had microbiologically confirmed Gram-negative infections. Maximal changes in mean hemoglobin levels were reached on day 10 (-1.04 g/dL) and day 5 (-1.36 g/dL) with low- and high-dose phospholipid emulsion, respectively, and on day 14 (-0.82 g/dL) with placebo. CONCLUSIONS: Treatment with phospholipid emulsion did not reduce 28-day all-cause mortality, or reduce the onset of new organ failure in patients with suspected or confirmed Gram-negative severe sepsis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Macrophage migration inhibitory factor (MIF) is an upstream activator of the immune response that counter-regulates the immunosuppressive effects of glucocorticoids. While MIF is released by cells in response to diverse microbial and invasive stimuli, evidence that glucocorticoids in low concentrations also induce MIF secretion suggests an additional regulatory relationship between these mediators. We investigated the expression of MIF from the human CEM T cell line, which exists in two well-characterized, glucocorticoid-sensitive (CEM-C7) and glucocorticoid-resistant (CEM-C1) variant clones. Dexamethasone in low concentrations induced MIF secretion from CEM-C7 but not CEM-C1 T cells by a bell-shaped dose response that was similar to that reported previously for the release of MIF by monocytes/macrophages. Glucocorticoid stimulation of CEM-C7 T cells was accompanied by an MIF transcriptional response, which by promoter analysis was found to involve the GRE and ATF/CRE transcription factor binding sites. These data support a glucocorticoid-mediated MIF secretion response by T cells that may contribute to the regulation of the adaptive immune response.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Macrophage migration inhibitory factor (MIF) has emerged as a pivotal mediator of innate immunity and has been shown to be an important effector molecule in severe sepsis. Melioidosis, caused by Burkholderia pseudomallei, is an important cause of community-acquired sepsis in Southeast-Asia. We aimed to characterize the expression and function of MIF in melioidosis. METHODOLOGY AND PRINCIPAL FINDINGS: MIF expression was determined in leukocytes and plasma from 34 melioidosis patients and 32 controls, and in mice infected with B. pseudomallei. MIF function was investigated in experimental murine melioidosis using anti-MIF antibodies and recombinant MIF. Patients demonstrated markedly increased MIF mRNA leukocyte and MIF plasma concentrations. Elevated MIF concentrations were associated with mortality. Mice inoculated intranasally with B. pseudomallei displayed a robust increase in pulmonary and systemic MIF expression. Anti-MIF treated mice showed lower bacterial loads in their lungs upon infection with a low inoculum. Conversely, mice treated with recombinant MIF displayed a modestly impaired clearance of B. pseudomallei. MIF exerted no direct effects on bacterial outgrowth or phagocytosis of B. pseudomallei. CONCLUSIONS: MIF concentrations are markedly elevated during clinical melioidosis and correlate with patients' outcomes. In experimental melioidosis MIF impaired antibacterial defense.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To discuss the difficulty in using the concept of sepsis for clinical trials and propose new ways for designing future trials for severe infections. DESIGN: Short position statement. METHODS AND MAIN RESEARCH: Using a thorough evaluation of the recent literature in the field of severe sepsis and septic shock, the authors challenge the concept of sepsis as used in the past two decades and propose new ideas for designing future trials in this setting. The two main proposals are first to use a systematic assessment of the targeted inflammatory mediators when the study intends to counteract or replace those mediators (e.g., anti-tumor necrosis factor-alpha, activated protein C) and, second, to select more homogeneous populations, coming back to "precise infectious diseases," such as severe community-acquired pneumonia, severe peritonitis, or meningitis. CONCLUSIONS: The concept of sepsis has been useful to help clinicians to suspect and detect severe infections. Due to a considerable heterogeneity in the patients and type of infections included in the trials performed in the last two decades, it has not been useful in demonstrating the efficacy of new compounds. The authors propose a dramatic change in the design of future trials dealing with severe infections.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Central Park Lake Watershed Assessment and Management Plan identified four categories where improvements are needed to remove the 23 acre lake from the impaired waters list. These include the wastewater system, runoff from surrounding lands, in-lake nutrient re-suspension and runoff from hard surfaces within the park. The lake is currently impaired for bacteria, algae and pH. Through outcomes of the Watershed Assessment and Management Plan, this proposal includes for abandonment and reclamation of the single cell wastewater lagoon site, replacement with three conventional septic systems and construction of two wetlands. One of the wetlands is located on the same site as the reclaimed lagoon and the other is located to intercept sediment and trap nutrients transported by tile lines. The prescribed wastewater system improvements are based on assessment by grab samples test by the State Hygienic Lab, development of a Preliminary Engineering Report, soil analysis and communication with IDNR wastewater officials. The two wetland sites were assessed by officials from IDALS and the Jones County SWCD. This project is part of $1.7 million lake restoration effort to reclaim the 47 year old lake. The lake has a positive economic impact of more than $7.6 million annually and supports an average annual visitation of 58,145, according to the Iowa Lakes Valuation Project, conducted by Iowa State University.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The proposed project will include the construction of a sanitary sewer collection system and a community gravel filter wastewater treatment system in the unsewered community of Maple River Junction in Carroll County. The system will be built to include approximately 1,150 feet of 4-inch sanitary sewer main, 3,540 feet of 4-inch service main an approximately 35 septic tanks. Some existing 4-inch PVC sewer piping as well as existing septic tanks in good condition will continue to be used in order to control capital costs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Leisure Lake is approximately a 67 acre water body located in northwest Jackson County with a 2,681 acre drainage area. The watershed including the lake is a tributary to Lytle Creek which drains into the North Fork of the Maquoketa River. Portions of the Lytle Creek and North Fork Maquoketa River are on the 303(d) impaired waterbodies list. The project area includes a community of 370 residential properties and one business that currently has no central wastewater collection and treatment system. The purpose of this project is to construct a wastewater collection and treatment facility to improve water quality in the creek and river. The project will eliminate the non-permitted septic systems and construct a new wastewater system to properly treat wastewater prior to its discharge into the waterways.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mills County proposes to reduce the identified impairment of the watershed, Keg Creek, by eliminating one of the main reasons for the impairment - non-conforming, on-site septic tanks that allow effluent to drain into the creek from the unincorporated community of Mineola. This has been identified by the county as a major priority. Therefore, the county proposes to construct a collection system and lagoon treatment facility, which would eliminate effluent from draining into Keg Creek. Regional Water will own, operate, and manage the collection and treatment systems in Mineola for Mills County.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Enzymatic biodiesel is becoming an increasingly popular topic in bioenergy literature because of its potential to overcome the problems posed by chemical processes. However, the high cost of the enzymatic process still remains the main drawback for its industrial application, mostly because of the high price of refined oils. Unfortunately, low cost substrates, such as crude soybean oil, often release a product that hardly accomplishes the final required biodiesel specifications and need an additional pretreatment for gums removal. In order to reduce costs and to make the enzymatic process more efficient, we developed an innovative system for enzymatic biodiesel production involving a combination of a lipase and two phospholipases. This allows performing the enzymatic degumming and transesterification in a single step, using crude soybean oil as feedstock, and converting part of the phospholipids into biodiesel. Since the two processes have never been studied together, an accurate analysis of the different reaction components and conditions was carried out. Results Crude soybean oil, used as low cost feedstock, is characterized by a high content of phospholipids (900 ppm of phosphorus). However, after the combined activity of different phospholipases and liquid lipase Callera Trans L, a complete transformation into fatty acid methyl esters (FAMEs >95%) and a good reduction of phosphorus (P <5 ppm) was achieved. The combination of enzymes allowed avoidance of the acid treatment required for gums removal, the consequent caustic neutralization, and the high temperature commonly used in degumming systems, making the overall process more eco-friendly and with higher yield. Once the conditions were established, the process was also tested with different vegetable oils with variable phosphorus contents. Conclusions Use of liquid lipase Callera Trans L in biodiesel production can provide numerous and sustainable benefits. Besides reducing the costs derived from enzyme immobilization, the lipase can be used in combination with other enzymes such as phospholipases for gums removal, thus allowing the use of much cheaper, non-refined oils. The possibility to perform degumming and transesterification in a single tank involves a great efficiency increase in the new era of enzymatic biodiesel production at industrial scale.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Viking Lake State Park is beautiful resource which has been special to residents of Southwest Iowa and visitors from around the region. Unfortunately, Viking Lake itself is being impacted by non-point source pollution. Water quality conditions are becoming the reason that visitors are shying away from the park instead of flocking to it. To combat these non-point source problems the Viking Lake Water Quality Project has been initiated and $327,000 has been allocated through the Section 319/WSPF Program which will address water quality concerns in the watershed. Additionally, IDNR Fisheries is preparing for an entire renovation of Viking Lake in 2006. One funding gap remains, that may prevent this comprehensive water quality project from achieving a successful endpoint. Funds are still needed for the renovation of malfunctioning septic systems at Viking Village housing development which is adjacent to the park, and has been identified as a primary source of contamination entering the lake. The intent of this application is to secure funds so that these septic system problems can be corrected and water quality conditions of this important natural resource restored for public enjoyment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An overall effort has been initiated to improve the quality of the Yellow River in Northeast Iowa by reducing the amount of sediment and bacteria entering the stream. Funding for this project will be utilized to improve stream quality to the level of fully supporting game fish such as brown, rainbow and brook trout, walleye, northern pike and smallmouth bass. The Yellow River has the potential to be one of the top trout streams, not only in Iowa, but in the entire Upper Midwest. This project will greatly enhance recreational activities such as fishing, canoeing and inner tubing and will greatly increase tourism dollars to the state. The project will specifically address two sources of impairment: stream bank erosion and coliform bacteria from both livestock and inadequate human septic systems.