931 resultados para Receiver


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method of determining spectral parameters p (slope of the phase PSD) and T (phase PSD at 1 Hz) and hence tracking error variance in a GPS receiver PLL from just amplitude and phase scintillation indices and an estimated value of the Fresnel frequency has been previously presented. Here this method is validated using 50 Hz GPS phase and amplitude data from high latitude receivers in northern Norway and Svalbard. This has been done both using (1) a Fresnel frequency estimated using the amplitude PSD (in order to check the accuracy of the method) and (2) a constant assumed value of Fresnel frequency for the data set, convenient for the situation when contemporaneous phase PSDs are not available. Both of the spectral parameters (p, T) calculated using this method are in quite good agreement with those obtained by direct measurements of the phase spectrum as are tracking jitter variances determined for GPS receiver PLLs using these values. For the Svalbard data set, a significant difference in the scintillation level observed on the paths from different satellites received simultaneously was noted. Then, it is shown that the accuracy of relative GPS positioning can be improved by use of the tracking jitter variance in weighting the measurements from each satellite used in the positioning estimation. This has significant advantages for scintillation mitigation, particularly since the method can be accomplished utilizing only time domain measurements thus obviating the need for the phase PSDs in order to extract the spectral parameters required for tracking jitter determination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ionospheric scintillations are caused by time-varying electron density irregularities in the ionosphere, occurring more often at equatorial and high latitudes. This paper focuses exclusively on experiments undertaken in Europe, at geographic latitudes between similar to 50 degrees N and similar to 80 degrees N, where a network of GPS receivers capable of monitoring Total Electron Content and ionospheric scintillation parameters was deployed. The widely used ionospheric scintillation indices S4 and sigma(phi) represent a practical measure of the intensity of amplitude and phase scintillation affecting GNSS receivers. However, they do not provide sufficient information regarding the actual tracking errors that degrade GNSS receiver performance. Suitable receiver tracking models, sensitive to ionospheric scintillation, allow the computation of the variance of the output error of the receiver PLL (Phase Locked Loop) and DLL (Delay Locked Loop), which expresses the quality of the range measurements used by the receiver to calculate user position. The ability of such models of incorporating phase and amplitude scintillation effects into the variance of these tracking errors underpins our proposed method of applying relative weights to measurements from different satellites. That gives the least squares stochastic model used for position computation a more realistic representation, vis-a-vis the otherwise 'equal weights' model. For pseudorange processing, relative weights were computed, so that a 'scintillation-mitigated' solution could be performed and compared to the (non-mitigated) 'equal weights' solution. An improvement between 17 and 38% in height accuracy was achieved when an epoch by epoch differential solution was computed over baselines ranging from 1 to 750 km. The method was then compared with alternative approaches that can be used to improve the least squares stochastic model such as weighting according to satellite elevation angle and by the inverse of the square of the standard deviation of the code/carrier divergence (sigma CCDiv). The influence of multipath effects on the proposed mitigation approach is also discussed. With the use of high rate scintillation data in addition to the scintillation indices a carrier phase based mitigated solution was also implemented and compared with the conventional solution. During a period of occurrence of high phase scintillation it was observed that problems related to ambiguity resolution can be reduced by the use of the proposed mitigated solution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

After removal of the Selective Availability in 2000, the ionosphere became the dominant error source for Global Navigation Satellite Systems (GNSS), especially for the high-accuracy (cm-mm) demanding applications like the Precise Point Positioning (PPP) and Real Time Kinematic (RTK) positioning.The common practice of eliminating the ionospheric error, e. g. by the ionosphere free (IF) observable, which is a linear combination of observables on two frequencies such as GPS L1 and L2, accounts for about 99% of the total ionospheric effect, known as the first order ionospheric effect (Ion1). The remaining 1% residual range errors (RREs) in the IF observable are due to the higher - second and third, order ionospheric effects, Ion2 and Ion3, respectively. Both terms are related with the electron content along the signal path; moreover Ion2 term is associated with the influence of the geomagnetic field on the ionospheric refractive index and Ion3 with the ray bending effect of the ionosphere, which can cause significant deviation in the ray trajectory (due to strong electron density gradients in the ionosphere) such that the error contribution of Ion3 can exceed that of Ion2 (Kim and Tinin, 2007).The higher order error terms do not cancel out in the (first order) ionospherically corrected observable and as such, when not accounted for, they can degrade the accuracy of GNSS positioning, depending on the level of the solar activity and geomagnetic and ionospheric conditions (Hoque and Jakowski, 2007). Simulation results from early 1990s show that Ion2 and Ion3 would contribute to the ionospheric error budget by less than 1% of the Ion1 term at GPS frequencies (Datta-Barua et al., 2008). Although the IF observable may provide sufficient accuracy for most GNSS applications, Ion2 and Ion3 need to be considered for higher accuracy demanding applications especially at times of higher solar activity.This paper investigates the higher order ionospheric effects (Ion2 and Ion3, however excluding the ray bending effects associated with Ion3) in the European region in the GNSS positioning considering the precise point positioning (PPP) method. For this purpose observations from four European stations were considered. These observations were taken in four time intervals corresponding to various geophysical conditions: the active and quiet periods of the solar cycle, 2001 and 2006, respectively, excluding the effects of disturbances in the geomagnetic field (i.e. geomagnetic storms), as well as the years of 2001 and 2003, this time including the impact of geomagnetic disturbances. The program RINEX_HO (Marques et al., 2011) was used to calculate the magnitudes of Ion2 and Ion3 on the range measurements as well as the total electron content (TEC) observed on each receiver-satellite link. The program also corrects the GPS observation files for Ion2 and Ion3; thereafter it is possible to perform PPP with both the original and corrected GPS observation files to analyze the impact of the higher order ionospheric error terms excluding the ray bending effect which may become significant especially at low elevation angles (Ioannides and Strangeways, 2002) on the estimated station coordinates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: O objetivo do presente estudo foi analisar a eficiência de diferentes equações antropométricas para a identificação de excesso de gordura corporal entre crianças e adolescentes. MÉTODOS: A amostra foi composta por 1.498 indivíduos (678 meninos e 820 meninas), com idade entre 7 e 17 anos (M=13,7, DP=2,0), da cidade de Presidente Prudente (SP). A massa corporal e a estatura foram mensuradas para o cálculo do Índice de Massa Corporal. Também foi realizada a mensuração da circunferência de cintura e das dobras cutâneas subescapular, tricipital, abdominal e da panturrilha. O percentual de gordura corporal foi calculado por meio de quatro equações: Slaughter et al., Slaughter II et al., Dezenberg et al., e Deurenberg et al.. Para indicar a eficiência das diferentes equações antropométricas na indicação da obesidade, foi utilizada a análise da curva Receiver Operating Characteristic Curve. RESULTADOS: No grupo masculino, foram observados valores de sensibilidade elevados (82,4% a 100,0%) e valores oscilando de baixo a alto, para a especificidade (20,9% a 94,9%). Para o sexo feminino, os valores de sensibilidade variaram entre moderado e alto (72,2% a 99,4%); e os de especificidade apresentaram, também, grande oscilação entre baixo e alto (21,6% a 98,2%). CONCLSÃO: A equação proposta por Deurenberg et al., apresentou o melhor desempenho no diagnóstico tanto da presença como da ausência de obesidade na amostra investigada.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To assess viability of the development of percentage body fat cutoffs based on blood pressure values in Brazilian adolescents.Methods: A cross-sectional study was conducted with a sample of 358 male subjects from 8 to 18 years old. Blood pressure was measured by the oscilometric method, and body composition was measured by dual-energy X-ray absorptiometry (DXA).Results: For the identification of elevated blood pressure, these nationally developed body fat cutoffs presented relative accuracy. The cutoffs were significantly associated with elevated blood pressure [odds ratio = 5.91 (95% confidence interval: 3.54-9.86)].Conclusions: Development of national body fat cutoffs is viable, because presence of high accuracy is an indication of elevated blood pressure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The SPPB provides information about physical function and is a predictor of adverse events in the elderly. Frailty is a multidimensional syndrome that increases susceptibility to diseases and disability. However it may be possible to prevent or postpone frailty if is identified early. Our objective is to analyze SPPB s ability in screening for frailty a community-dwelling young elderly from cities with distinct socioeconomic conditions. Methods: Data were originated from community dwelling adults (65-74 years old) in Canada (Saint Bruno; n = 60) and Brazil (Santa Cruz; n = 64). SPPB was used to assess physical performance. Frailty was defined as the presence of ≥ 3 of these criteria: weight loss, exhaustion, weakness, mobility limitation and low physical activity. One point was given for each criterion met, totalizing a frailty score ranged from 0 to 5. The Linear Regression and Receiver Operating Characteristics analyses were performed to evaluate the SPPB s screening ability. Results: Mean age was 69.48, 10.0% of the Saint Bruno s sample and 28.1% of Santa Cruz s were frail (p = 0.001), the SPPB score means were 9.6 and 8.5 respectively (p = 0.01). SPPB correlated with the frailty score (R2 = 0.33), with better results for Saint Bruno. A cutoff of 9 in SPPB had good sensitivity and specificity in discriminating frail from non frail in Saint Bruno (AUC = 0.81) but showed fair results in Santa Cruz (AUC = 0.61). Conclusion: The SPPB has moderate ability in predicting frailty among older adult s population, and is an useful test to identify people with good functionality and low frailty when SPPB scores are ≥9

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the use of a large-aperture PVDF receiver in the measurement of liquid density and composite material elastic constants. The density measurement of several liquids is obtained with accuracy of 0.2% using a conventional NDE emitter transducer and a 70-mm-diameter, 52-mu m P(VDF-TrFE) membrane with gold electrodes. The determination of the elastic constants is based on the phase velocity measurement. Diffraction can lead to errors around 1% in velocity measurement when using alternatively the conventional pair of ultrasonic transducers (1-MHz frequency and 19-mm-diameter) operating in through-transmission mode, separated by a distance of 100 mm. This effect is negligible when using a pair of 10-MHz, 19-mm-diameter transducers. Nevertheless, the dispersion at 10 MHz can result in errors of about 0.5%, when measuring the velocity in composite materials. The use of an 80-mm diameter, 52-mu m-thick PVDF membrane receiver practically eliminates the diffraction effects in phase velocity measurement. The elastic constants of a carbon fiber reinforced polymer were determined and compared with the values obtained by a tensile test. (C) 2009 Elsevier B. V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Cryptococcus neoformans causes meningitis and disseminated infection in healthy individuals, but more commonly in hosts with defective immune responses. Cell-mediated immunity is an important component of the immune response to a great variety of infections, including yeast infections. We aimed to evaluate a specific lymphocyte transformation assay to Cryptococcus neoformans in order to identify immunodeficiency associated to neurocryptococcosis (NCC) as primary cause of the mycosis.Methods: Healthy volunteers, poultry growers, and HIV-seronegative patients with neurocryptococcosis were tested for cellular immune response. Cryptococcal meningitis was diagnosed by India ink staining of cerebrospinal fluid and cryptococcal antigen test (Immunomycol-Inc, SP, Brazil). Isolated peripheral blood mononuclear cells were stimulated with C. neoformans antigen, C. albicans antigen, and pokeweed mitogen. The amount of H-3-thymidine incorporated was assessed, and the results were expressed as stimulation index (SI) and log SI, sensitivity, specificity, and cut-off value (receiver operating characteristics curve). We applied unpaired Student t tests to compare data and considered significant differences for p<0.05.Results: The lymphotoxin alpha showed a low capacity with all the stimuli for classifying patients as responders and non-responders. Lymphotoxin alpha stimulated by heated-killed antigen from patients with neurocryptococcosis was not affected by TCD4+ cell count, and the intensity of response did not correlate with the clinical evolution of neurocryptococcosis.Conclusion: Response to lymphocyte transformation assay should be analyzed based on a normal range and using more than one stimulator. The use of a cut-off value to classify patients with neurocryptococcosis is inadequate. Statistical analysis should be based on the log transformation of SI. A more purified antigen for evaluating specific response to C. neoformans is needed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Determinar a acurácia das variáveis: tempo de escada (tTE), potência de escada (PTE), teste de caminhada (TC6) e volume expiratório forçado (VEF1) utilizando o consumo máximo de oxigênio (VO2máx) como padrão-ouro. MÉTODOS: Os testes foram realizados em 51 pacientes. O VEF1 foi obtido através da espirometria. O TC6 foi realizado em corredor plano de 120m. O TE foi realizado em escada de 6 lances obtendo-se tTE e PTE. O VO2máx foi obtido por ergoespirometria, utilizando o protocolo de Balke. Foram calculados a correlação linear de Pearson (r) e os valores de p, entre VO2máx e variáveis. Para o cálculo da acurácia, foram obtidos os pontos de corte, através da curva característica operacional (ROC). A estatística Kappa (k) foi utilizada para cálculo da concordância. RESULTADOS: Obteve-se as acurácias: tTE - 86%, TC6 - 80%, PTE - 71%, VEF1(L) - 67%, VEF1% - 63%. Para o tTE e TC6 combinados em paralelo, obteve-se sensibilidade de 93,5% e em série, especificidade de 96,4%. CONCLUSÃO: O tTE foi a variável que apresentou a melhor acurácia. Quando combinados o tTE e TC6 podem ter especificidade e sensibilidade próxima de 100%. Estes testes deveriam ser mais usados rotineiramente, especialmente quando a ergoespirometria para a medida de VO2máx não é disponível.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The concern with issues related to consumer protection has emerged in North America and then spread throughout the world. In Brazil, consumer‟s rights and interests only gained greater importance after their consolidation in the Constitution of 1988 and the enactment of the 8078/90 Law (Consumer‟s Protection and Defense Code), which established the consumerist microsystem. The understanding of the legal relationship of consumption concept is necessarily connected to knowledge of the elements that compose it. Among these, we can find the consumer and the provider (subjective elements), the product or service (objective elements), and the consumer‟s condition as final receiver of the consumption object (finalistic element). In order to elucidate the configuration of consumer protection before advertising communication, this work will analyze the advertising through the prism of consumerist laws, conceptualizing it and presenting a differentiation of it in relation to practices such as marketing, offer and commercial communication as well as examining its several kinds of manifestation, focusing mainly the ones categorized as misleading or unfair advertising. All kinds of advertising communication against the consumerist microsystem are subject to judicial control exercised by the State. Besides individual protection possibilities, this state-owned control can be collectively exercised as a result of the utilization of public civil action and popular action. Some specific categories of advertising (smoking products, alcoholic beverages, pesticides, medicines and therapies) are still subject to a set of particular restraints provided by the 9294/96 Law, which enables the performance of a special control in relation to them. In addition to state control, there is also a system of advertising communication self-regulation, which develops itself through the actions of the National Council of Advertising Self-Regulation that are based mainly on the laws established by the Brazilian Code of Advertising Self-Regulation and its annexes. However, this system of advertising self-regulation still has some deficiencies that hinder its effectiveness

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The objective of this study was to determine the early echocardiographic predictors of elevated left ventricular end-diastolic pressure (LVEDP) after a long follow-up period in the infarcted rat model.Material/Methods: Five days and three months after surgery, sham and infarcted animals were subjected to transthoracic echocardiography. Regression analysis and receiver-operating characteristic (ROC) curve were performed for predicting increased LVEDP 3 months after MI.Results: Among all of the variables, assessed 5 days after myocardial infarction, infarct size (OR: 0.760; CI 95% 0.563-0.900; p=0.005), end-systolic area (ESA) (OR: 0.761; Cl 95% 0.564-0.900; p=0.008), fractional area change (FAC) (OR: 0.771; CI 95% 0.574-0.907; p=0.003), and posterior wall-shortening velocity (PWSV) (OR: 0.703; CI 95% 0.502-0.860; p=0.048) were predictors of increased LVEDP. The LVEDP was 3.6 +/- 1.8 mmHg in the control group and 9.4 +/- 7.8 mmHg among the infarcted animals (p=0.007). Considering the critical value of predictor variables in inducing cardiac dysfunction, the cut-off value was 35% for infarct size, 0.33 cm(2) for ESA, 40% for FAC, and 26 mm/s for PWSV.Conclusions: Infarct size, FAC, ESA, and PWSV, assessed five days after myocardial infarction, can be used to estimate an increased LVEDP three months following the coronary occlusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o desempenho diagnóstico do índice de respiração rápida e superficial (IRRS) na predição do insucesso da extubação de pacientes adultos em terapia intensiva e verificar a adequação do valor de corte clássico para esse índice. MÉTODOS: Estudo prospectivo realizado na unidade de terapia intensiva de adultos do Hospital das Clínicas da Faculdade de Medicina de Botucatu, através da avaliação do IRRS em 73 pacientes consecutivos considerados clinicamente prontos para extubação. RESULTADOS: O IRRS com valor de corte clássico (105 ciclos/min/L) apresentou sensibilidade de 20% e especificidade de 95% (soma = 115%). A análise da curva receiver operator characteristic (ROC) demonstrou melhor valor de corte (76,5 ciclos/min/L), o qual forneceu sensibilidade de 66% e especificidade de 74% (soma = 140%), e a área sob a curva ROC para o IRRS foi de 0,78. CONCLUSÕES: O valor de corte clássico do IRRS se mostrou inadequado nesta casuística, prevendo apenas 20% dos pacientes com falha na extubação. A obtenção do novo valor de corte permitiu um acréscimo substancial de sensibilidade, com aceitável redução da especificidade. O valor da área sob a curva ROC indicou satisfatório poder discriminativo do índice, justificando a validação de sua aplicação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Crustal thickness and VP/VS estimates are essential to the studies of subsurface geological structures and also to the understanding of the regional tectonic evolution of a given area. In this dissertation, we use the Langston´s (1979) Receiver Function Method using teleseismic events reaching the seismographic station with angles close to the vertical. In this method, the information of the geologic structures close to the station is isolated so that effects related to the instrument response and source mechanics are not present. The resulting time series obtained after the deconvolution between horizontal components contains the larger amplitude referring to the P arrival, followed by smaller arrival caused by the reverberation and conversion of the P-wave at the base of the crust. We also used the HK-Stacking after Zhu & Kanamori (2000) to obtain crustal thickness and Vp/VS estimates. This method works stacking receiver functions so that the best estimates of crustal thickness and Vp/VS are found when the direct P, the Ps wave and the first multiple are coherently stacked. We used five broadband seismographic stations distributed over the Borborema Province, NE Brazil. Crustal thickness and Vp/VS estimates are consistent with the crust-mantle interface obtained using gravity data. We also identified crutal thickening in the NW portion of the province, close to Sobral/CE. Towards the center-north portion of the province, there is an evident crustal thinning which coincides with a geological feature consisting of an alignment of sedimentary basins known as the Cariris-Potiguar trend. Towards the NE portion of the province, in Solânea/PB and Agrestina/PE regions, occurs a crustal thickening and a systematic increase in the VP/VS values which suggest the presence of mafic rocks in the lower crust also consistent with the hypothesis of underplating in the region