999 resultados para Plastic expression
Resumo:
Thesis presented to obtain the Ph.D. degree in Biology (Molecular Genetics), by the Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia.
Resumo:
A S. mansoni adult worm cDNA expression library was screened with sera from baboons in a early phase after infection. The clones that were positive with the early infection sera were examined for reactivity with pre-infection sera and heterologous infection sera. In order to discriminate a positive antibody reaction from the reactivity due to residual anti-E. coli antibodies, an unrelated cDNA clone was plated with the positive clone. The unrelated clone provided the negative background and the contrast necessary to discern a positive antibody reaction. In this way, we were able to eliminate selected clones that were positive with the pre-infection sera or heterologous infection sera. This characterization of the expression library clones enabled us to quickly target only clones with the desired pattern of antibody reactivity for sequencing, subcloning, and expressing
Resumo:
Dissertation presented to obtain a Ph.D. degree in Sciences of Engineering and Technology, Cell Technology, at the Instituto de Tecnologia Química e Biológica, Universidade Nova de Lisboa
Resumo:
Plos Genetics, 5(7): ARTe1000566
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
Dissertação para obtenção do Grau de Mestre em Genética Molecular e Biomedicina
Resumo:
RESUMO: Os Staphylococcus aureus resistentes à meticilina (MRSA, do inglês “methicillin-resistant Staphylococcus aureus”) são um dos principais agentes responsáveis por infeções hospitalares. Os MRSA são resistentes a praticamente todos os antibióticos β-lactâmicos devido a dois mecanismos principais: produção de β-lactamase (bla), codificada pelo gene blaZ, e produção de uma proteína de ligação à penicilina (PBP2a, do inglês “penicillin binding protein 2”), codificada pelo gene mecA. Estes dois genes são regulados por sistemas homólogos, constituídos por um sensor-transdutor (BlaR1 e MecR1) e um repressor (BlaI e MecI), de tal modo que ambos os sistemas são capazes de co-regular os genes mecA e blaZ, embora com eficiências de indução muito diferentes. De facto, a indução mediada pelo sistema mecI-mecR1 é tão lenta que se acredita que este sistema não está funcional na maioria das estirpes MRSA. No entanto, dados recentes do nosso laboratório, demonstram a ausência de relação entre a presença do gene mecI e o nível de resistência à meticilina em estirpes MRSA epidémicas, e também que, o fenótipo de resistência da grande maioria das estirpes não é perturbado pela sobre-expressão em trans do repressor mecI. Curiosamente, as duas estirpes em que a expressão da resistência foi afetada pela sobre-expressão do mecI são negativas para o locus da β-lactamase, o que sugere que este locus pode interferir diretamente com a repressão do gene mecA mediada pelo MecI. Nesta tese de mestrado esta hipótese foi explorada usando estratégias de biologia molecular e ensaios fenotípicos da resistência aos -lactâmicos. Os resultados obtidos demonstram que a presença do plasmídeo nativo da β-lactamase não só anula a repressão mediada pelo MecI, como também aumenta o nível de resistência das estirpes parentais. Várias hipóteses foram então formuladas para explicar estas observações. Dados preliminares, em conjunto com evidências experimentais publicadas, sugerem que o BlaI forma hetero-dímeros com o MecI que, após a indução, são inativados eficientemente pelo BlaR1. Em conclusão, estes resultados apresentam novas perspetivas para o mecanismo de regulação do mecA e para uma nova importante função do operão da β-lactamase para o fenótipo das estirpes MRSA.-------------------ABSTRACT: Methicillin-resistant Staphylococcus aureus (MRSA) is an important nosocomial pathogen and is also emerging in the community. MRSA is cross-resistant to virtually all β-lactam antibiotics and has acquired two main resistance mechanisms: production of β-lactamase (bla), coded by blaZ, and production of penicillin binding protein 2a (PBP2a), coded by mecA. Both genes are regulated by homologous sensor-transducers (BlaR1 and MecR1) and repressors (BlaI and MecI), and coregulation of mecA and blaZ by both systems has been demonstrated, although with remarkable different efficiencies. In fact, induction of mecA by mecI-mecR1 is so slow that it is believed it is not functional in most MRSA strains. However, recent data from our laboratory has unexpectedly demonstrated that not only there is no correlation between the presence of mecI gene and the resistance level in epidemic MRSA strains, but also that for most strains there were no significant changes on the resistance phenotype upon the mecI overexpression in trans. Interestingly, the two strains in which mecI overexpression affected the resistance expression were negative for the bla locus, suggesting that this locus may interfere directly with the MecI-mediated repression of mecA and account for those puzzling observations. In this master thesis we have explored this hypothesis using molecular biology strategies and phenotypic analysis of -lactam resistance. The data obtained demonstrate that the presence of a wild-type plasmid containing the bla locus not only disrupts the MecImediated repression, but also significantly enhances the expression of resistance. Several preliminary hypotheses were formulated to explain these observations and preliminary data, together with published evidence, support the working model that BlaI forms functional hetero-dimers with MecI, which upon induction are readily inactivated by BlaR1. These results provide new insights into the regulatory mechanism(s) of mecA and open new perspectives for the role of β-lactamase operon in the MRSA phenotype.
Resumo:
Dissertation to obtain a Master Degree in Biotechnology
Resumo:
The P System antigens have been detected in numerous parasites, bacterias and viruses, nevertheless the clinical significance is still unknown. The aim was to study the presence of P1 antigenic determiners in A. lumbricoides extracts by means of the use of 6 different monoclonal antibodies of well-known concentrations and Ig class. We worked with 14 A. lumbricoides extracts. Inhibition Agglutination Test was made in a bromelin enzymatic medium and 4 ºC temperature. Titre, Score and Sensitivity Parameter were determined for each monoclonal antibody against red cells suspension used as revealing system. Ten extracts inhibited the agglutination of all anti P1 monoclonal antibodies. The 4 remaining extracts only inhibited the agglutination of some of them. It is demonstrated that the extracts have P1 activity. This activity is independent of titre, Score, Sensitivity Parameter, concentration and Ig class and it depends on the epitope at which the monoclonal antibody is directed.
Resumo:
This work shows that the synthesis of protein plastic antibodies tailored with selected charged monomersaround the binding site enhances protein binding. These charged receptor sites are placed over a neutralpolymeric matrix, thus inducing a suitable orientation the protein reception to its site. This is confirmed bypreparing control materials with neutral monomers and also with non-imprinted template. This concepthas been applied here to Prostate Specific Antigen (PSA), the protein of choice for screening prostate can-cer throughout the population, with serum levels >10 ng/mL pointing out a high probability of associatedcancer.Protein Imprinted Materials with charged binding sites (C/PIM) have been produced by surfaceimprinting over graphene layers to which the protein was first covalently attached. Vinylben-zyl(trimethylammonium chloride) and vinyl benzoate were introduced as charged monomers labellingthe binding site and were allowed to self-organize around the protein. The subsequent polymerizationwas made by radical polymerization of vinylbenzene. Neutral PIM (N/PIM) prepared without orientedcharges and non imprinted materials (NIM) obtained without template were used as controls.These materials were used to develop simple and inexpensive potentiometric sensor for PSA. Theywere included as ionophores in plasticized PVC membranes, and tested over electrodes of solid or liq-uid conductive contacts, made of conductive carbon over a syringe or of inner reference solution overmicropipette tips. The electrodes with charged monomers showed a more stable and sensitive response,with an average slope of -44.2 mV/decade and a detection limit of 5.8 × 10−11mol/L (2 ng/mL). The cor-responding non-imprinted sensors showed lower sensitivity, with average slopes of -24.8 mV/decade.The best sensors were successfully applied to the analysis of serum, with recoveries ranging from 96.9to 106.1% and relative errors of 6.8%.
Resumo:
This work uses surface imprinting to design a novel smart plastic antibodymaterial (SPAM) for Haemoglobin (Hb). Charged binding sites are described here for the first time to tailor plastic antibody nanostructures for a large size protein such as Hb. Its application to design small, portable and low cost potentiometric devices is presented. The SPAM material was obtained by linking Hb to silica nanoparticles and allowing its ionic interaction with charged vinyl monomers. A neutral polymeric matrix was created around these and the imprinted protein removed. Additional materials were designed in parallel acting as a control: a neutral imprinted material (NSPAM), obtained by removing the charged monomers from the procedure, and the Non-Imprinted (NI) versions of SPAM and NSPAM by removing the template. SEM analysis confirmed the surface modification of the silica nanoparticles. All materials were mixed with PVC/plasticizer and applied as selective membranes in potentiometric transduction. Electromotive force (emf) variations were detected only for selective membranes having a lipophilic anionic additive in the membrane. The presence of Hb inside these membranes was evident and confirmed by FTIR, optical microscopy and Raman spectroscopy. The best performance was found for SPAM-based selective membranes with an anionic lipophilic additive, at pH 5. The limits of detection were 43.8 mg mL 1 and linear responses were obtained down to 83.8 mg mL 1, with an average cationic slope of +40 mV per decade. Good selectivity was also observed against other coexisting biomolecules. The analytical application was conducted successfully, showing accurate and precise results.
Resumo:
Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.
Resumo:
A backside protein-surface imprinting process is presented herein as a novel way to generate specific synthetic antibody materials. The template is covalently bonded to a carboxylated-PVC supporting film previously cast on gold, let to interact with charged monomers and surrounded next by another thick polymer. This polymer is then covalently attached to a transducing element and the backside of this structure (supporting film plus template) is removed as a regular “tape”. The new sensing layer is exposed after the full template removal, showing a high density of re-binding positions, as evidenced by SEM. To ensure that the templates have been efficiently removed, this re-binding layer was cleaned further with a proteolytic enzyme and solution washout. The final material was named MAPS, as in the back-side reading of SPAM, because it acts as a back-side imprinting of this recent approach. It was able to generate, for the first time, a specific response to a complex biomolecule from a synthetic material. Non-imprinted materials (NIMs) were also produced as blank and were used as a control of the imprinting process. All chemical modifications were followed by electrochemical techniques. This was done on a supporting film and transducing element of both MAPS and NIM. Only the MAPS-based device responded to oxLDL and the sensing layer was insensitive to other serum proteins, such as myoglobin and haemoglobin. Linear behaviour between log(C, μg mL−1) versus charged tranfer resistance (RCT, Ω) was observed by electrochemical impedance spectroscopy (EIS). Calibrations made in Fetal Calf Serum (FCS) were linear from 2.5 to 12.5 μg mL−1 (RCT = 946.12 × log C + 1590.7) with an R-squared of 0.9966. Overall, these were promising results towards the design of materials acting close to the natural antibodies and applied to practical use of clinical interest.
Resumo:
Sulfadimethoxine (SDM) is one of the drugs, often used in the aquaculture sector to prevent the spread of disease in freshwater fish aquaculture. Its spread through the soil and surface water can contribute to an increase in bacterial resistance. It is therefore important to control this product in the environment. This work proposes a simple and low-cost potentiometric device to monitor the levels of SDM in aquaculture waters, thus avoiding its unnecessary release throughout the environment. The device combines a micropipette tip with a PVC membrane selective to SDM, prepared from an appropriate cocktail, and an inner reference solution. The membrane includes 1% of a porphyrin derivative acting as ionophore and a small amount of a lipophilic cationic additive (corresponding to 0.2% in molar ratio). The composition of the inner solution was optimized with regard to the kind and/or concentration of primary ion, chelating agent and/or a specific interfering charged species, in different concentration ranges. Electrodes constructed with inner reference solutions of 1 × 10−8 mol/L SDM and 1 × 10−4 mol/L chromate ion showed the best analytical features. Near-Nernstian response was obtained with slopes of −54.1 mV/decade, an extraordinary detection limit of 7.5 ng/mL (2.4 × 10−8 mol/L) when compared with other electrodes of the same type. The reproducibility, stability and response time are good and even better than those obtained by liquid contact ISEs. Recovery values of 98.9% were obtained from the analysis of aquaculture water samples.
Resumo:
A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.