936 resultados para POTENTIOMETRIC BIOSENSOR
Resumo:
ELECTROCHEMICAL AND CALORIMETRIC INVESTIGATION OF INTERACTION OF NOVEL BISCATIONIC ANTICANCER AGENTS WITH DNA. Biscationic amidines bind in the DNA minor groove and present biological activity against a range of infectious diseases. Two new biscationic compounds (bis-alpha,omega-S-thioureido, amino and sulfide analogues) were synthesized in good yields and fully characterized, and their interaction with DNA was also investigated. Isothermal titration calorimetry (ITC) was used to measure the thermodynamic properties of binding interactions between DNA and these ligands. A double stranded calf thymus DNA immobilized on an electrode surface was used to study the possible DNA-interacting abilities of these compounds towards dsDNA in situ. A remarkable interaction of these compounds with DNA was demonstrated and their potential application as anticancer agents was furthered.
Resumo:
The search for bioactive molecules to be employed as recognition elements in biosensors has stimulated researchers to pore over the rich Brazilian biodiversity. In this sense, we introduce the use of natural cashew gum (Anacardium occidentale L) as an active biomaterial to be used in the form of layer-by-layer films, in conjunction with phthalocyanines, which were tested as electrochemical sensors for dopamine detection. We investigated the effects of chemical composition of cashew gum from two different regions of Brazil (Piaui and Ceara states) on the physico-chemical characteristics of these nanostructures. The morphology of the nanostructures containing cashew gum was studied by atomic force microscopy which indicates that smooth films punctuated by globular features were formed that showed low roughness values. The results indicate that, independent of the origin, cashew gum stands out as an excellent film forming material with potential application in nanobiomedical devices as electrochemical sensors. (c) 2012 Elsevier B.V. All rights reserved.
Resumo:
We report an efficient alternative to obtain recessed microelectrodes device on gold electrode surface, in which mixed self-assembled monolayer of long and short carbon alkanethiol chains was used for this purpose. Development of the modified electrodes included the chemical adsorption of 11-mercaptoundecanoic acid and 2-mercaptoethanol solution, as well as their mixtures, on gold surface, resulting in the final mixed self-assembled monolayer configuration. For comparison, the electrochemical performance of self-assembled monolayer of 11-mercaptoundecanoic acid. 3-mercaptopropionic acid, 4-mercapto-1-butanol and 6-mercapto-1-hexanol modified electrodes was also investigated. It was verified that, in the mixed self-assembled monolayer, the 11-mercaptoundecanoic acid acts as a barrier for electron transfer while the short alkanethiol chair is deposited in an island-like shape through which electrons can be freely transferred to ions in solution, allowing electrochemical reactions to occur. The performance of the modified electrodes toward microelectrode behavior was investigated via cyclic voltammetry and electrochemical impedance spectroscopy measurements using [Fe(CN)(6)](3-/4-) redox couple as a probe. In this case, sigmoidal voltammetric responses were obtained, very similar to those observed for microelectrodes. Such behavior reinforces the proposition of electron transfer through the short alkanethiol chain layer and surface blockage by the long chain one. Electrochemical impedance results allowed calculated the mean radius value of each microelectrode disks of 3.8 mu m with about 22 mu m interval between them. The microelectrode environment provided by the mixed self-assembled monolayer can be conveniently used to provide an efficient catalytic conversion in biosensing applications. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
A new biomaterial, based on silica organofunctionalized with p-phenylenediamine (p-PDA) and the enzyme peroxidase, was used in the development of an enzymatic solid-phase reactor. The analytical techniques used in the characterization showed that the organic ligand was incorporated into the silica matrix. Thus, the silica modified with p-PDA allowed the incorporation of peroxidase by the electrostatic interaction between the carboxylic groups present in the enzyme molecules and the amino groups attached to the silica. The enzymatic solid-phase reactor was used for chemical oxidation of phenols in 1, 4-benzoquinone that was then detected by chronoamperometry. The system allowed the analysis of hydroquinone with a detection limit of 83.6 nmol L-1. Thus, the new material has potential in the determination of phenolic compounds river water samples.
Resumo:
The aim of this study is to develop a new enzymeless electroanalytical method for the indirect quantification of creatinine from urine sample. This method is based on the electrochemical monitoring of picrate anion reduction at a glassy carbon electrode in an alkaline medium before and after it has reacted with creatinine (Jaffe's reaction). By using the differential pulse voltammetry technique under the optimum experimental conditions (step potential, amplitude potential, reaction time, and temperature), a linear analytical curve was obtained for concentrations of creatinine ranging from 1 to 80 mu mol L-1, with a detection limit of 380 nmol L-1. This proposed method was used to measure creatinine in human urine without the interference of most common organic species normally present in biological fluids (e.g., uric acid, ascorbic acid, glucose, and phosphocreatinine). The results obtained using urine samples were highly similar to the results obtained using the reference spectrophotometric method (at a 95% confidence level). (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Despite growing knowledge on the biological effects of ultraviolet (UV) radiation on human health and ecosystems, it is still difficult to predict the negative impacts of the increasing incidence of solar UV radiation in a scenario of global warming and climate changes. Hence, the development and application of DNA-based biological sensors to monitor the solar UV radiation under different environmental conditions is of increasing importance. With a mind to rendering a molecular view-point of the genotoxic impact of sunlight, field experiments were undertaken with a DNA-dosimeter system in parallel with physical photometry of solar UVB/UVA radiation, at various latitudes in South America. Onapplying biochemical and immunological approaches based on specific DNA-repair enzymes and antibodies, for evaluating sunlight-induced DNA damage profiles, it became clear that the genotoxic potential of sunlight does indeed vary according to latitude. Notwithstanding, while induction of oxidized DNA bases is directly dependent on an increase in latitude, the generation of 6-4PPs is inversely so, whereby the latter can be regarded as a biomolecular marker of UVB incidence. This molecular DNA lesion-pattern largely reflects the relative incidence of UVA and UVB energy at any specific latitude. Hereby is demonstrated the applicability of this DNA-based biosensor for additional, continuous field experiments, as a means of registering variations in the genotoxic impact of solar UV radiation. Environ. Mol. Mutagen. 2012. (c) 2012 Wiley Periodicals, Inc.
Resumo:
The layer-by-layer (LbL) technique combined with field-effect transistor (FET) based sensors has enabled the production of pH-sensitive platforms with potential application in biosensors. A variation of the FET architecture, so called separative extended gate FET (SEGFET) devices, are promise as an alternative to conventional ion sensitive FET (ISFET). SEGFET configuration exhibits the advantage of combining the field-effect concept with organic and inorganic materials directly adsorbed on the extended gate, allowing the test of new pH-sensitive materials in a simple and low cost way. In this communication, poly(propylene imine) dendrimer (PPI) and TiO2 nanoparticles (TiO2-np) were assembled onto gold-covered substrates via layer-by-layer technique to produce a low cost SEGFET pH sensor. The sensor presented good pH sensitivity, ca. 57 mV pH(-1), showing that our strategy has potential advantages to fabricate low cost pH-sensing membranes. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
In this paper we discuss the detection of glucose and triglycerides using information visualization methods to process impedance spectroscopy data. The sensing units contained either lipase or glucose oxidase immobilized in layer-by-layer (LbL) films deposited onto interdigitated electrodes. The optimization consisted in identifying which part of the electrical response and combination of sensing units yielded the best distinguishing ability. It is shown that complete separation can be obtained for a range of concentrations of glucose and triglyceride when the interactive document map (IDMAP) technique is used to project the data into a two-dimensional plot. Most importantly, the optimization procedure can be extended to other types of biosensors, thus increasing the versatility of analysis provided by tailored molecular architectures exploited with various detection principles. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Magnetic nanoparticles are promising for a variety of applications, such as biomedical devices, spin electronics, magnetic data storage media, to name a few. However, these goals may only be reached if stable and organized structures are fabricated. In this article, we report on a single-step synthetic route with the coprecipitation method, in which iron oxide magnetic nanoparticles (Fe3O4 NPs) were stabilized in aqueous media using the poly(diallyldimethylammonium chloride) (PDAC) polyelectrolyte. The Fe3O4 NPs had a diameter of ca. 5 nm, according to transmission electron microscopy (TEM) images, being arranged in an inverse spinel structure typical of magnetite. An investigation with infrared spectroscopy indicated that the mechanisms of stabilization in the polymer matrix were based on the interaction between quaternary amide groups from PDAC and the nanoparticle surface. The Fe3O4-PDAC NPs exhibited considerable magnetic susceptibility, with a monotonic increase in the magnetization with decreasing temperature. These Fe3O4-PDAC NPs were immobilized in layer-by-layer (LbL) films, being alternated with layers of poly(vinylsulfonic acid) (PVS). The LbL films were much rougher than typical films made with polyelectrolytes, and Fe3O4-PDAC NPs have been responsible for the high electrocatalytic activity toward H2O2 reduction, with an overpotential shift of 0.69 V. Overall, the stability, magnetic properties and film-forming ability indicate that the Fe3O4-PDAC NPs may be used for nanoelectronics and bioelectrochemical devices requiring reversible and magnetic redox materials.
Resumo:
Background: Due to the increase of solar ultraviolet radiation (UV) incidence over the last few decades, the use of sunscreen has been widely adopted for skin protection. However, considering the high efficiency of sunlight-induced DNA lesions, it is critical to improve upon the current approaches that are used to evaluate protection factors. An alternative approach to evaluate the photoprotection provided by sunscreens against daily UV radiation-induced DNA damage is provided by the systematic use of a DNA dosimeter. Methodology/Principal Findings: The Sun Protection Factor for DNA (DNA-SPF) is calculated by using specific DNA repair enzymes, and it is defined as the capacity for inhibiting the generation of cyclobutane pyrimidine dimers (CPD) and oxidised DNA bases compared with unprotected control samples. Five different commercial brands of sunscreen were initially evaluated, and further studies extended the analysis to include 17 other products representing various formulations and Sun Protection Factors (SPF). Overall, all of the commercial brands of SPF 30 sunscreens provided sufficient protection against simulated sunlight genotoxicity. In addition, this DNA biosensor was useful for rapidly screening the biological protection properties of the various sunscreen formulations. Conclusions/Significance: The application of the DNA dosimeter is demonstrated as an alternative, complementary, and reliable method for the quantification of sunscreen photoprotection at the level of DNA damage.
Resumo:
Biscationic amidines bind in the DNA minor groove and present biological activity against a range of infectious diseases. Two new biscationic compounds (bis-α,ω-S-thioureido, amino and sulfide analogues) were synthesized in good yields and fully characterized, and their interaction with DNA was also investigated. Isothermal titration calorimetry (ITC) was used to measure the thermodynamic properties of binding interactions between DNA and these ligands. A double stranded calf thymus DNA immobilized on an electrode surface was used to study the possible DNA-interacting abilities of these compounds towards dsDNA in situ. A remarkable interaction of these compounds with DNA was demonstrated and their potential application as anticancer agents was furthered.
Sviluppo di biosensori: modifiche di superfici elettrodiche e sistemi di immobilizzazione enzimatica
Resumo:
An amperometric glucose biosensor was developed using an anionic clay matrix (LDH) as enzyme support. The enzyme glucose oxidase (GOx) was immobilized on a layered double hydroxide Ni/Al-NO3 LDH during the electrosynthesis, which was followed by crosslinking with glutaraldehyde (GA) vapours or with GA and bovine serum albumin (GABSA) to avoid the enzyme release. The electrochemical reaction was carried out potentiostatically, at -0.9V vs. SCE, using a rotating disc Pt electrode to assure homogeneity of the electrodeposition suspension, containing GOx, Ni(NO3)2 and Al(NO3)3 in 0.3 M KNO3. The mechanism responsible of the LDH electrodeposition involves the precipitation of the LDH due to the increase of pH at the surface of the electrode, following the cathodic reduction of nitrates. The Pt surface modified with the Ni/Al-NO3 LDH shows a much reduced noise, giving rise to a better signal to noise ratio for the currents relative to H2O2 oxidation, and a linear range for H2O2 determination wider than the one observed for bare Pt electrodes. We pointed out the performances of the biosensor in terms of sensitivity to glucose, calculated from the slope of the linear part of the calibration curve for enzimatically produced H2O2; the sensitivity was dependent on parameters related to the electrodeposition in addition to working conditions. In order to optimise the glucose biosensor performances, with a reduced number of experimental runs, we applied an experimental design. A first screening was performed considering the following variables: deposition time (30 - 120 s), enzyme concentration (0.5 - 3.0 mg/mL), Ni/Al molar ratio (3:1 or 2:1) of the electrodeposition solution at a total metals concentration of 0.03 M and pH of the working buffer solution (5.5-7.0). On the basis of the results from this screening, a full factorial design was carried out, taking into account only enzyme concentration and Ni/Al molar ratio of the electrosynthesis solution. A full factorial design was performed to study linear interactions between factors and their quadratic effects and the optimal setup was evaluated by the isoresponse curves. The significant factors were: enzyme concentration (linear and quadratic terms) and the interaction between enzyme concentration and Ni/Al molar ratio. Since the major obstacle for application of amperometric glucose biosensors is the interference signal resulting from other electro-oxidizable species present in the real matrices, such as ascorbate (AA), the use of different permselective membranes on Pt-LDHGOx modified electrode was discussed with the aim of improving biosensor selectivity and stability. Conventional membranes obtained using Nafion, glutaraldehyde (GA) vapours, GA-BSA were tested together with more innovative materials like palladium hexacyanoferrate (PdHCF) and titania hydrogels. Particular attention has been devoted to hydrogels, because they possess some attractive features, which are generally considered to favour biosensor materials biocompatibility and, consequently, the functional enzyme stability. The Pt-LDH-GOx-PdHCF hydrogel biosensor presented an anti-interferant ability so that to be applied for an accurate glucose analysis in blood. To further improve the biosensor selectivity, protective membranes containing horseradish peroxidase (HRP) were also investigated with the aim of oxidising the interferants before they reach the electrode surface. In such a case glucose determination was also accomplished in real matrices with high AA content. Furthermore, the application of a LDH containing nickel in the oxidised state was performed not only as a support for the enzyme, but also as anti-interferant sistem. The result is very promising and it could be the starting point for further applications in the field of amperometric biosensors; the study could be extended to other oxidase enzymes.
Resumo:
Negli ultimi anni, un crescente numero di studiosi ha focalizzato la propria attenzione sullo sviluppo di strategie che permettessero di caratterizzare le proprietà ADMET dei farmaci in via di sviluppo, il più rapidamente possibile. Questa tendenza origina dalla consapevolezza che circa la metà dei farmaci in via di sviluppo non viene commercializzato perché ha carenze nelle caratteristiche ADME, e che almeno la metà delle molecole che riescono ad essere commercializzate, hanno comunque qualche problema tossicologico o ADME [1]. Infatti, poco importa quanto una molecola possa essere attiva o specifica: perché possa diventare farmaco è necessario che venga ben assorbita, distribuita nell’organismo, metabolizzata non troppo rapidamente, ne troppo lentamente e completamente eliminata. Inoltre la molecola e i suoi metaboliti non dovrebbero essere tossici per l’organismo. Quindi è chiaro come una rapida determinazione dei parametri ADMET in fasi precoci dello sviluppo del farmaco, consenta di risparmiare tempo e denaro, permettendo di selezionare da subito i composti più promettenti e di lasciar perdere quelli con caratteristiche negative. Questa tesi si colloca in questo contesto, e mostra l’applicazione di una tecnica semplice, la biocromatografia, per caratterizzare rapidamente il legame di librerie di composti alla sieroalbumina umana (HSA). Inoltre mostra l’utilizzo di un’altra tecnica indipendente, il dicroismo circolare, che permette di studiare gli stessi sistemi farmaco-proteina, in soluzione, dando informazioni supplementari riguardo alla stereochimica del processo di legame. La HSA è la proteina più abbondante presente nel sangue. Questa proteina funziona da carrier per un gran numero di molecole, sia endogene, come ad esempio bilirubina, tiroxina, ormoni steroidei, acidi grassi, che xenobiotici. Inoltre aumenta la solubilità di molecole lipofile poco solubili in ambiente acquoso, come ad esempio i tassani. Il legame alla HSA è generalmente stereoselettivo e ad avviene a livello di siti di legame ad alta affinità. Inoltre è ben noto che la competizione tra farmaci o tra un farmaco e metaboliti endogeni, possa variare in maniera significativa la loro frazione libera, modificandone l’attività e la tossicità. Per queste sue proprietà la HSA può influenzare sia le proprietà farmacocinetiche che farmacodinamiche dei farmaci. Non è inusuale che un intero progetto di sviluppo di un farmaco possa venire abbandonato a causa di un’affinità troppo elevata alla HSA, o a un tempo di emivita troppo corto, o a una scarsa distribuzione dovuta ad un debole legame alla HSA. Dal punto di vista farmacocinetico, quindi, la HSA è la proteina di trasporto del plasma più importante. Un gran numero di pubblicazioni dimostra l’affidabilità della tecnica biocromatografica nello studio dei fenomeni di bioriconoscimento tra proteine e piccole molecole [2-6]. Il mio lavoro si è focalizzato principalmente sull’uso della biocromatografia come metodo per valutare le caratteristiche di legame di alcune serie di composti di interesse farmaceutico alla HSA, e sul miglioramento di tale tecnica. Per ottenere una miglior comprensione dei meccanismi di legame delle molecole studiate, gli stessi sistemi farmaco-HSA sono stati studiati anche con il dicroismo circolare (CD). Inizialmente, la HSA è stata immobilizzata su una colonna di silice epossidica impaccata 50 x 4.6 mm di diametro interno, utilizzando una procedura precedentemente riportata in letteratura [7], con alcune piccole modifiche. In breve, l’immobilizzazione è stata effettuata ponendo a ricircolo, attraverso una colonna precedentemente impaccata, una soluzione di HSA in determinate condizioni di pH e forza ionica. La colonna è stata quindi caratterizzata per quanto riguarda la quantità di proteina correttamente immobilizzata, attraverso l’analisi frontale di L-triptofano [8]. Di seguito, sono stati iniettati in colonna alcune soluzioni raceme di molecole note legare la HSA in maniera enantioselettiva, per controllare che la procedura di immobilizzazione non avesse modificato le proprietà di legame della proteina. Dopo essere stata caratterizzata, la colonna è stata utilizzata per determinare la percentuale di legame di una piccola serie di inibitori della proteasi HIV (IPs), e per individuarne il sito(i) di legame. La percentuale di legame è stata calcolata attraverso il fattore di capacità (k) dei campioni. Questo parametro in fase acquosa è stato estrapolato linearmente dal grafico log k contro la percentuale (v/v) di 1-propanolo presente nella fase mobile. Solamente per due dei cinque composti analizzati è stato possibile misurare direttamente il valore di k in assenza di solvente organico. Tutti gli IPs analizzati hanno mostrato un’elevata percentuale di legame alla HSA: in particolare, il valore per ritonavir, lopinavir e saquinavir è risultato maggiore del 95%. Questi risultati sono in accordo con dati presenti in letteratura, ottenuti attraverso il biosensore ottico [9]. Inoltre, questi risultati sono coerenti con la significativa riduzione di attività inibitoria di questi composti osservata in presenza di HSA. Questa riduzione sembra essere maggiore per i composti che legano maggiormente la proteina [10]. Successivamente sono stati eseguiti degli studi di competizione tramite cromatografia zonale. Questo metodo prevede di utilizzare una soluzione a concentrazione nota di un competitore come fase mobile, mentre piccole quantità di analita vengono iniettate nella colonna funzionalizzata con HSA. I competitori sono stati selezionati in base al loro legame selettivo ad uno dei principali siti di legame sulla proteina. In particolare, sono stati utilizzati salicilato di sodio, ibuprofene e valproato di sodio come marker dei siti I, II e sito della bilirubina, rispettivamente. Questi studi hanno mostrato un legame indipendente dei PIs ai siti I e II, mentre è stata osservata una debole anticooperatività per il sito della bilirubina. Lo stesso sistema farmaco-proteina è stato infine investigato in soluzione attraverso l’uso del dicroismo circolare. In particolare, è stato monitorata la variazione del segnale CD indotto di un complesso equimolare [HSA]/[bilirubina], a seguito dell’aggiunta di aliquote di ritonavir, scelto come rappresentante della serie. I risultati confermano la lieve anticooperatività per il sito della bilirubina osservato precedentemente negli studi biocromatografici. Successivamente, lo stesso protocollo descritto precedentemente è stato applicato a una colonna di silice epossidica monolitica 50 x 4.6 mm, per valutare l’affidabilità del supporto monolitico per applicazioni biocromatografiche. Il supporto monolitico monolitico ha mostrato buone caratteristiche cromatografiche in termini di contropressione, efficienza e stabilità, oltre che affidabilità nella determinazione dei parametri di legame alla HSA. Questa colonna è stata utilizzata per la determinazione della percentuale di legame alla HSA di una serie di poliamminochinoni sviluppati nell’ambito di una ricerca sulla malattia di Alzheimer. Tutti i composti hanno mostrato una percentuale di legame superiore al 95%. Inoltre, è stata osservata una correlazione tra percentuale di legame è caratteristiche della catena laterale (lunghezza e numero di gruppi amminici). Successivamente sono stati effettuati studi di competizione dei composti in esame tramite il dicroismo circolare in cui è stato evidenziato un effetto anticooperativo dei poliamminochinoni ai siti I e II, mentre rispetto al sito della bilirubina il legame si è dimostrato indipendente. Le conoscenze acquisite con il supporto monolitico precedentemente descritto, sono state applicate a una colonna di silice epossidica più corta (10 x 4.6 mm). Il metodo di determinazione della percentuale di legame utilizzato negli studi precedenti si basa su dati ottenuti con più esperimenti, quindi è necessario molto tempo prima di ottenere il dato finale. L’uso di una colonna più corta permette di ridurre i tempi di ritenzione degli analiti, per cui la determinazione della percentuale di legame alla HSA diventa molto più rapida. Si passa quindi da una analisi a medio rendimento a una analisi di screening ad alto rendimento (highthroughput- screening, HTS). Inoltre, la riduzione dei tempi di analisi, permette di evitare l’uso di soventi organici nella fase mobile. Dopo aver caratterizzato la colonna da 10 mm con lo stesso metodo precedentemente descritto per le altre colonne, sono stati iniettati una serie di standard variando il flusso della fase mobile, per valutare la possibilità di utilizzare flussi elevati. La colonna è stata quindi impiegata per stimare la percentuale di legame di una serie di molecole con differenti caratteristiche chimiche. Successivamente è stata valutata la possibilità di utilizzare una colonna così corta, anche per studi di competizione, ed è stata indagato il legame di una serie di composti al sito I. Infine è stata effettuata una valutazione della stabilità della colonna in seguito ad un uso estensivo. L’uso di supporti cromatografici funzionalizzati con albumine di diversa origine (ratto, cane, guinea pig, hamster, topo, coniglio), può essere proposto come applicazione futura di queste colonne HTS. Infatti, la possibilità di ottenere informazioni del legame dei farmaci in via di sviluppo alle diverse albumine, permetterebbe un migliore paragone tra i dati ottenuti tramite esperimenti in vitro e i dati ottenuti con esperimenti sull’animale, facilitando la successiva estrapolazione all’uomo, con la velocità di un metodo HTS. Inoltre, verrebbe ridotto anche il numero di animali utilizzati nelle sperimentazioni. Alcuni lavori presenti in letteratura dimostrano l’affidabilita di colonne funzionalizzate con albumine di diversa origine [11-13]: l’utilizzo di colonne più corte potrebbe aumentarne le applicazioni.
Resumo:
Abstract (deutsch)Zielsetzung des Dissertationsvorhabens war die Beobachtung und Analyse von Gast-Wirt-Wechselwirkungen an oxidischen Oberflächen. Einer der Wechselwirkungspartner sollte dabei auf der Oberfläche immobilisiert, der andere in wäßriger Lösung darüber vorliegen.Eine empfindliche und oberflächensensitive Methode zur Beobachtung der Anlagerung unmarkierter Moleküle ist die Wellenleiterspektroskopie, insbesondere mit dem hier verwendeten und weiterentwickelten integriert-optischen Mach-Zehnder-Interferometer in Siliziumtechnik (Siliziumoxynitrid auf oxidiertem Siliziumwafer). Mit Hilfe des Interferometers wurden unterschiedliche Wirt-Gast-Systeme untersucht. Grundlage der Immobilisierung war jeweils die Funktionalisierung der Sensoroberfläche durch Selbstadsorption von Organosilanen. Durch unterschiedliche Organosilane, die zum Teil im Rahmen dieser Arbeit synthetisiert wurden, ließen sich die Wirtmoleküle beta-Cyclodextrin, Streptavidin, sowie unterschiedliche monoklonale Antikörperfragmente immobilisieren.- Der Einfluß der Oberfläche auf die Bindungsstärke des Wirtmoleküls beta-Cyclodextrin und unterschiedlicher Gastmoleküle wurde konzentrationsabhängig untersucht.- Silan-Biotinderivate mit unterschiedlicher Streptavidin-Affinität wurden an die Oberfläche immobilisiert und die Adsorption von Streptavidin an die Biotinderivate beobachtet. Dabei konnte unter anderem nachgewiesen werden, daß das Streptavidinadsorbat gequollen ist.- Als mögliche Anwendung wurde geprüft, ob das vorgestellte Interferometer durch die Funktionalisierung mit Antikörperfragmenten als Biosensor in Frage kommt. Es konnte nachgewiesen werden, daß sich Antikörper auf der Sensoroberfläche immobilisieren lassen und Antigene spezifisch an diese Antikörper adsorbieren.
Resumo:
Die Verbindung von elektrisch aktiven, lebenden Zellen zu extrazellulären Sensorsystemen eröffnet vielfälige Möglichkeiten im Bereich der Biosensorik. Die vorliegende Arbeit leistet einen Beitrag zum tieferen Verständnis der elektrischen Kopplungsmechanismen zwischen den biologischen und elektronischen Teilen solcher Hybridsysteme. Es wurden dazu drei Hauptbereiche bearbeitet:Ein System zur extrazellulären Signalableitung an lebenden Zellen bestehend aus einem Sensorchip, einem Vorverstärkerkopf und einem Hauptverstärker wurde weiterentwickelt.Als Sensoren wurden entweder Metallmikroelektroden-Chips mit 64 Kanälen oder Feldeffekt Transistoren-Chips mit 16 Kanälen (FET) eingesetzt. Es wurden zusätzlich spezielle FET Sensoren mit Rückseitenkontakten hergestellt und eingesetzt.Die elektrische Kopplung von einzelnen Nervenzellen der neuronalen Zell-Linien SH-SY5Y und TR14 oder primär kultivierten Neuronen aus dem Hirnstamm oder dem Hippocampus von embryonalen Ratten mit den extrazellulären Sensoren wurde untersucht. In der 'whole-cell' Patch-Clamp Technik wurden die Beiträge der spannungsgesteuerten Na+- und K+-Ionenkanäle zur extrazellulären Signalform identifiziert. Die Simulation der Signale mit einem Ersatzschaltkreis (Punkt-Kontakt Modell), der in PSPICE implementiert wurde, deutet auf eine starke Abhängigkeit der Signalformen in bezug auf Konzentrationsänderungen von Na+- und K+-Ionen im Volumenbereich zwischen Zelle und den ionensensitiven Transistoren hin. Ein empirisch erweitertes Punkt-Kontakt Modell wurde daraufhin vorgestellt.Im dritten Teil der Arbeit wurden Zellschichten von Kardiomyocyten embryonaler Ratten auf den extrazellulären Sensoren kultiviert. Die Eignung eines solchen Hybridsensors als Modellherz fuer das pharmazeutische Screeing wurde durch Messungen mit Herzstimulanzien und -relaktanzien bestätigt.