871 resultados para PM-AH e Análise de Desempenho


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper comprises an investigation on the influence of the variable family backgrounds (father school level, mother school level and family income) over the pupil s performance in admissions examination (entrance test or PROITEC) at Instituto Federal de Educação, Ciência e Tecnologia do Rio Grande do Norte (IFRN). From that point of view, the main goal of this research is to analyze the influence of the family background as a determiner of the pupil´s performance in the access to Technical and Professional education at IFRN. Secondary data were used from two databases (entrance test and PROITEC) adding up to 19.226 observations to the vacancies offered in the year of 2013. Aiming at achieving the proposed goal, a conceptual model composed of three hypothesis was developed. The results were presented in four stages: stage I presentation of the descriptive statistical results of the two databases; stage II separation of the campi in clusters; stage III analysis of multiple regressions; stage IV analysis of the logistics regressions. Two statistical tests were used to validate the hypothesis: T-test and Wald test. Hypothesis 1 and 2 were confirmed and H3 was refused. The results presented favorable causal connections to the family income and the father school level variables (with bigger effect for fathers with a higher education degree). The mother school level variable did not provide statistical significance for this research. Based on this result, after this work, this institution is to develop a strategic plan to assist in the success rate of students preparing diagnoses in order to diminish the effects of the variables that impacted negatively

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research consists in studying the influence of the various type of construction systems of roofs with their energy efficiency as well as on the cost benefit for the commercial buildings on the temperatures condition of the city of Natal/RN. The main goal of this research is to analyze the cost benefit of the construction systems of roofs available on the market, taking into consideration the energy efficiency of the commercial buildings artificially air conditioned in order to be used by the projectors and to be adequated to the temperatures condition of the city of Natal/RN. The method of valuation of the cost benefit of roof systems consists in six steps: Features and simulation of the reference building; Analyze of sensitivity; Analyzes, features and simulation of alternatives of roof construction systems; Analyze of the cost of implementation; Analyze of the benefits of the alternatives comparing to the base case; And finally the analyze of the cost benefit. The model type chosen as reference was stores with pre molded buildings and system of roof with fiber ciment and ceiling . The thermal results showed the influence of the roof system on the energy efficiency of the building. The Final results of the simulations of the alternatives comes to a conclusion that the absortance is the variable that presents the best cost benefit relation and the reduction on the thermal transmittance still has limitations because of the high cost

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Natural ventilation is an efficient bioclimatic strategy, one that provides thermal comfort, healthful and cooling to the edification. However, the disregard for quality environment, the uncertainties involved in the phenomenon and the popularization of artificial climate systems are held as an excuse for those who neglect the benefits of passive cooling. The unfamiliarity with the concept may be lessened if ventilation is observed in every step of the project, especially in the initial phase in which decisions bear a great impact in the construction process. The tools available in order to quantify the impact of projected decisions consist basically of the renovation rate calculations or computer simulations of fluids, commonly dubbed CFD, which stands for Computational Fluid Dynamics , both somewhat apart from the project s execution and unable to adapt for use in parametric studies. Thus, we chose to verify, through computer simulation, the representativeness of the results with a method of simplified air reconditioning rate calculation, as well as making it more compatible with the questions relevant to the first phases of the project s process. The case object consists of a model resulting from the recommendations of the Código de Obras de Natal/ RN, customized according to the NBR 15220. The study has shown the complexity in aggregating a CFD tool to the process and the need for a method capable of generating data at the compatible rate to the flow of ideas and are discarded during the project s development. At the end of our study, we discuss the necessary concessions for the realization of simulations, the applicability and the limitations of both the tools used and the method adopted, as well as the representativeness of the results obtained

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The building envelope is the principal mean of interaction between indoors and environment, with direct influence on thermal and energy performance of the building. By intervening in the envelope, with the proposal of specific architectural elements, it is possible to promote the use of passive strategies of conditioning, such as natural ventilation. The cross ventilation is recommended by the NBR 15220-3 as the bioclimatic main strategy for the hot and humid climate of Natal/RN, offering among other benefits, the thermal comfort of occupants. The analysis tools of natural ventilation, on the other hand, cover a variety of techniques, from the simplified calculation methods to computer fluid dynamics, whose limitations are discussed in several papers, but without detailing the problems encountered. In this sense, the present study aims to evaluate the potential of wind catchers, envelope elements used to increase natural ventilation in the building, through CFD simplified simulation. Moreover, it seeks to quantify the limitations encountered during the analysis. For this, the procedure adopted to evaluate the elements implementation and efficiency was the CFD simulation, abbreviation for Computer Fluid Dynamics, with the software DesignBuilder CFD. It was defined a base case, where wind catchers were added with various settings, to compare them with each other and appreciate the differences in flows and air speeds encountered. Initially there has been done sensitivity tests for familiarization with the software and observe simulation patterns, mapping the settings used and simulation time for each case simulated. The results show the limitations encountered during the simulation process, as well as an overview of the efficiency and potential of wind catchers, with the increase of ventilation with the use of catchers, differences in air flow patterns and significant increase in air speeds indoors, besides changes found due to different element geometries. It is considered that the software used can help designers during preliminary analysis in the early stages of design

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal - RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Confirming the Brazilian tendency in the field, the multifamily vertical condominium habitats in Natal are defined as buildings with three or more floors which have been an increasingly used solution. In the mentioned project, the connection between the projectarchitects and the user/ buyers are spread out, by which the first people conceive the realestate property as a creation for the market and not the individual client in specific. Such situation along with technical and financial limitations of the project lead to the adoption of standard solutions to be utilized by clients with different profiles. Besides that, there are various legal and urban parameters by the City Director Plan showing elements of great influence in the final solution adopted by the mentioned edifices. Moving to this subject in general, this project is focused on the case study of the Ed. Ville de Montpellier, having as a base of Post Occupancy Evaluation (POE), considered an efficient tool to analyze and keep up with the progress of the construction of the building, including technical approvals, the application of surveys with the local residents and the creation of informal interviews. The data shows that with time some items that initially motivated the acquisition of the realestate property (with a social common area) move to being less valued, and that the residents quickly alter the pre constructed space, thus seeking to alter the property in a more personal and conforming manner. The possibility of a new emphasis for projects on the mentioned space should also be in discussion, the created project calls for the attention of projected conceptual aspects and interdependence within project and construction which permits the indication of some recommendations for the projection of multifamily residential buildings within the studied realm

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was intended to investigate how the urban form has been influencing the changes in the climate of the city and make a correlation between the climate and the thermal sensation of the users of open spaces. The research was developed in the district of Petrópolis in Natal/ RN whose occupation has been almost consolidated. Among other reasons, this district was selected because it was planned considering the environmental aspects of comfort. The methodologies used are based on KATZSCHNER (1997) and OLIVEIRA (1988) studies, which suggest the drawing and analysis of maps of the area under study, including topography, height of the buildings, land use, green areas, and types of soil pavement, as well as measurement of the environmental variables: air temperature, relative humidity, direction and wind speed for a comparative study. As part of this, study local users of the district were interviewed about their thermal sensations in open spaces. For the statistical analysis, data was collected at 10 distinct points characterized by BUSTOS ROMERO (2002), being 8 within the district and 2 at different places (outside the district), at climatologic stations, in 3 periods (August/2000, January/2002 and June/2002), for 4 consecutive days for each measurement (from Sunday to Wednesday) at the time of lower and higher temperatures in the city, 6:00 am and 1:00 pm, respectively. At the same time interviews were carried out with users of the open spaces in the area, totaling 171 valid formularies. The urban form showed a rather leveled topography, great diversity of land use and height of the buildings, with the existence of an area mostly occupied with high buildings, very little green area and soil practically impermeable. The statistical analysis showed high temperature and humidity levels. The wind direction is predominantly Southeast with extremely variable speeds. When the data from this district is compared with the data from other areas in the city and its outskirt, it was observed that this district is hotter and less ventilated than the others; besides, most users said that they felt uncomfortable in the local environmental conditions. The results of the analysis generated a zoning for the district with recommendations for soil occupation. The profile of the user was defined regarding the thermal comfort, as well as some discussion about the comfort parameters, including the proposal of limiting areas of temperature and humidity for the thermal comfort in the open spaces

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The failure of materials is always an unwelcome event for several reasons: human lives are put in danger, economic losses, and interference in the availability of products and services. Although the causes of failures and behaviour of materials can be known, the prevention of such a condition is difficult to be guaranteed. Among the failures, wear abrasion by the low voltage is the kind of failure that occurs in more equipment and parts industry. The Plants Sucroalcooleiras suffer significant losses because of such attrition, this fact that motivated their choice for the development of this work. For both, were considered failures in the swing hammers desfibradores stopped soon after the exchange provided in accordance with tonnage of cane processed, then were analyzed by the level of wear testing of rubber wheel defined by the standard ASTM G65-91.The failures were classified as to the origin of the cause and mechanism, moreover, were prepared with samples of welding procedures according to ASME code, sec. IX as well, using the technique of thermal spraying to analyze the performance of these materials produced in laboratories, and compares them with the solder used in the plant. It was observed that the bodies-of-proof prepared by the procedure described as welding, and the thermal spraying the results of losing weight have been minimized significantly compared to the preparations in the plant. This is because the use of techniques more appropriate and more controlled conditions of the parameters of welding. As for the thermal spraying, this technique has presented a satisfactory result, but requires the use of these coatings in the best condition for real affirmation of the results

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The low tenacity presented by the Portland cement pastes used in the oil wells cementation has been motivating several researches with attention focused on alternative materials. Additives have been developed to generate flexible pastes with mechanical resistance capable to support the expansions and retractions of the metallic covering of the wells that submit to the steam injection, technique very used to increase the recovery factor in oil reservoirs with high viscosity. A fresh paste with inadequate rheological behavior may commit the cementation process seriously, involving flaws that affect the performance of the paste substantially in the hardened state. This work proposes the elaboration and the rheological analysis of Portland cement pastes with addition of residues of rubber tire in several proportions, with the aim of minimizing the damages provoked in the hem cementing of these wells. By thermogravimetric analysis, the particles of eraser that go by the sieve of 0,5mm (35 mesh) opening and treated superficially with NaOH solution of 1 mol/L presented appropriate thermal resistance for wells that submit to thermal cyclic. The evaluation of the study based on the results of the rheological analysis of the pastes, complemented by the mechanical analysis, thickening, stability, tenor of free water and filtrate loss, being used as parameter a paste reference, without rubber addition. The results showed satisfactory rheology, passive of few corrections; considerable loss of mechanical resistance (traction and compression), compensated by earnings of tenacity, however with established limits for its application in oil wells; satisfactory stability, free water and thickening time

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although already to exist alternative technique and economically viable for destination of used tires, quantitative data on properties of constructive elements that use the rubber waste as aggregate still are restricted. In the present work, the waste proceeding from industry of retreading as material for manufacture of composite destined to the production of constructive elements was considered. Mechanical and thermal properties of mortar had been analyzed Portland cement with addition of waste without treatment, in the ratios of 10%, 20% and 30% in mass in relation to the mass of the cement, substituting the aggregate in the trace in mortar 1:5 mass cement and sand. The size of the used residue varied between 0,30mm and 4,8mm (passing in the bolter 4,8mm and being restrained in the one of 0,30mm), being it in the formats fibers and granular. The influences of the size and the percentage of residue added to the mortar (in substitution to the aggregate) in the thermal and mechanical properties had been considered. Assays of body-of-test in thestates had been become fullfilled cool (consistency index) and hardened (absorption of water for capillarity, strength the compression, traction and strength flexural). The work is centralized in the problem of the relation thermal performance /strength mechanics of used constructive systems in regions of low latitudes (Been of the Piauí), characterized for raised indices of solar radiation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Brazil and around the world, oil companies are looking for, and expected development of new technologies and processes that can increase the oil recovery factor in mature reservoirs, in a simple and inexpensive way. So, the latest research has developed a new process called Gas Assisted Gravity Drainage (GAGD) which was classified as a gas injection IOR. The process, which is undergoing pilot testing in the field, is being extensively studied through physical scale models and core-floods laboratory, due to high oil recoveries in relation to other gas injection IOR. This process consists of injecting gas at the top of a reservoir through horizontal or vertical injector wells and displacing the oil, taking advantage of natural gravity segregation of fluids, to a horizontal producer well placed at the bottom of the reservoir. To study this process it was modeled a homogeneous reservoir and a model of multi-component fluid with characteristics similar to light oil Brazilian fields through a compositional simulator, to optimize the operational parameters. The model of the process was simulated in GEM (CMG, 2009.10). The operational parameters studied were the gas injection rate, the type of gas injection, the location of the injector and production well. We also studied the presence of water drive in the process. The results showed that the maximum vertical spacing between the two wells, caused the maximum recovery of oil in GAGD. Also, it was found that the largest flow injection, it obtained the largest recovery factors. This parameter controls the speed of the front of the gas injected and determined if the gravitational force dominates or not the process in the recovery of oil. Natural gas had better performance than CO2 and that the presence of aquifer in the reservoir was less influential in the process. In economic analysis found that by injecting natural gas is obtained more economically beneficial than CO2

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Biomass is considered the largest renewable energy source that can be used in an environmentally sustainable. From the pyrolysis of biomass is possible to obtain products with higher energy density and better use properties. The liquid resultant of this process is traditionally called bio-oil. The use of infrared burners in industrial applications has many advantages in terms of technical-operational, for example, uniformity in the heat supply in the form of radiation and convection, with a greater control of emissions due to the passage of exhaust gases through a macroporous ceramic bed. This paper presents a commercial infrared burner adapted with an ejector proposed able to burn a hybrid configuration of liquefied petroleum gas (LPG) and bio-oil diluted. The dilution of bio-oil with absolute ethanol aimed to decrease the viscosity of the fluid, and improving the stability and atomization. It was introduced a temperature controller with thermocouple modulating two stages (low heat / high heat), and solenoid valves for fuels supply. The infrared burner has been tested, being the diluted bio-oil atomized, and evaluated its performance by conducting energy balance. The method of thermodynamic analysis to estimate the load was used an aluminum plate located at the exit of combustion gases and the distribution of temperatures measured by thermocouples. The dilution reduced the viscosity of the bio-oil in 75.4% and increased by 11% the lower heating value (LHV) of the same, providing a stable combustion to the burner through the atomizing with compressed air and burns combined with LPG. Injecting the hybrid fuel there was increase in the heat transfer from the plate to the environment in 21.6% and gain useful benefit of 26.7%, due to the improved in the efficiency of the 1st Law of Thermodynamics of infrared burner

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work proposes a model to investigate the use of a cylindrical antenna used in the thermal method of recovering through electromagnetic radiation of high-viscosity oil. The antenna has a simple geometry, adapted dipole type, and it can be modelled by using Maxwell s equation. The wavelet transforms are used as basis functions and applied in conjunction with the method of moments to obtain the current distribution in the antenna. The electric field, power and temperature distribution are carefully calculated for the analysis of the antenna as electromagnetic heating. The energy performance is analyzed based on thermo-fluid dynamic simulations at field scale, and through the adaptation in the Steam Thermal and Advanced Processes Reservoir Simulator (STARS) by Computer Modelling Group (CMG). The model proposed and the numerical results obtained are stable and presented good agreement with the results reported in the specialized literature

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A legislação ambiental e os principais agentes que se relacionam com a empresa se constituem em fatores exógenos que não podem ser negligenciados ao formular-se e avaliar-se a política ambiental corporativa. As influências exógenas e seus efeitos sobre a gestão ambiental e o gerenciamento de projetos de exploração e produção (E&P) e, por essa via, sobre o desempenho ambiental, foram objetos de estudo desta tese. Embora o desempenho ambiental seja um assunto relevante, a pesquisa sobre esse tema ainda é escassa. Tal carência desponta ainda mais acentuada quando se aborda o desempenho ambiental de projetos na indústria de petróleo e gás. O principal objetivo deste estudo foi avaliar a relação entre a legislação ambiental vigente, as ações de órgãos reguladores, fornecedores, empresas terceirizadas e comunidades locais e o desempenho ambiental dos projetos de E&P na indústria de petróleo e gás e, também, analisar os efeitos do sistema de gestão ambiental e o gerenciamento dos projetos sobre tal desempenho. Na fase abdutiva, foi conduzido um estudo de caso com abordagem qualitativa em uma grande empresa brasileira do setor de petróleo e gás, na fase dedutiva, foi realizada uma pesquisa survey explanatória de corte transversal com abordagem quantitativa, incluindo 113 projetos de E&P de cinco unidades executoras da empresa. Foi formulado um modelo conceitual, com cinco construtos e sete hipóteses de pesquisa, representativo dos efeitos de fatores externos sobre o desempenho ambiental dos projetos de E&P. Os dados foram tratados aplicando a Análise Fatorial Exploratória e a Modelagem de Equações Estruturais com aplicação dos softwares IBM® SPSS® Statistics 20.0 e IBM® SPSS® Amos 18.0. O modelo de equações estruturais foi reespecificado e estimado utilizando o método de Máxima Verossimilhança e o procedimento bootstrap com 2000 reamostragens, até alcançar adequados valores dos índices de ajustamento. O modelo mostrou boa aderência às evidências empíricas, representando uma teoria explicativa dos fatores que influenciam o desempenho ambiental dos projetos de E&P na empresa estudada. As estatísticas descritivas apontaram adequado desempenho dos projetos de E&P com relação aos efluentes descartados, volume de água reutilizada, redução de resíduos e práticas de reciclagem. Identificou-se que projetos de maior porte alcançam melhor desempenho ambiental em relação aos de menor tamanho. Não foram achadas diferenças significativas entre os desempenhos de projetos executados por unidades operacionais distintas. Os resultados da modelagem indicaram que nem a legislação ambiental, nem os agentes externos exercem influência significativa sobre a sistemática da gestão dos projetos de E&P. Os agentes externos atuam sobre a gestão ambiental da empresa exercitando capacidades colaborativas, obstrutivas e propositivas. A legislação ambiental é percebida como entrave ao desenvolvimento dos projetos ao longo de seu ciclo de vida, principalmente, pelas deficiências dos órgãos ambientais. Identificou-se que o sistema de gestão ambiental influencia diretamente o Programa de Desenvolvimento e Execução de Projetos de E&P, que, por sua vez, provoca efeitos diretos e indiretos sobre o desempenho ambiental. Finalmente, comprovou-se que o Sistema de Gestão Ambiental da empresa é determinante para o desempenho ambiental dos projetos de E&P, tanto pelos seus efeitos diretos, como pelos indiretos, estes últimos mediados pela sistemática de gestão dos projetos de E&P