956 resultados para Operating instructions, usability test, target group, misunderstanding


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work proposes hardware architecture, VHDL described, developed to embedded Artificial Neural Network (ANN), Multilayer Perceptron (MLP). The present work idealizes that, in this architecture, ANN applications could easily embed several different topologies of MLP network industrial field. The MLP topology in which the architecture can be configured is defined by a simple and specifically data input (instructions) that determines the layers and Perceptron quantity of the network. In order to set several MLP topologies, many components (datapath) and a controller were developed to execute these instructions. Thus, an user defines a group of previously known instructions which determine ANN characteristics. The system will guarantee the MLP execution through the neural processors (Perceptrons), the components of datapath and the controller that were developed. In other way, the biases and the weights must be static, the ANN that will be embedded must had been trained previously, in off-line way. The knowledge of system internal characteristics and the VHDL language by the user are not needed. The reconfigurable FPGA device was used to implement, simulate and test all the system, allowing application in several real daily problems

Relevância:

30.00% 30.00%

Publicador:

Resumo:

From what was stated in the Montreal Protocol, the researchers and refrigeration industry seek substitutes for synthetic refrigerants -chlorofluorocarbons (CFCs) and HCFCs (HCFC) - that contribute to the depletion of the ozone layer. The phase-out of these substances was started using as one of the replacement alternatives the synthetic fluids based on hydro fluorocarbons (HFCs) that have zero potential depletion of the ozone layer. However, contribute to the process of global warming. HFC refrigerants are greenhouse gases and are part of the group of gases whose emissions must be reduced as the Kyoto Protocol says. The hydrocarbons (HC's), for not contribute to the depletion of the ozone layer, because they have very low global warming potential, and are found abundantly in nature, has been presented as an alternative, and therefore, are being used in new home refrigeration equipment in several countries. In Brazil, due to incipient production of domestic refrigerators using HC's, the transition refrigerants remain on the scene for some years. This dissertation deals with an experimental evaluation of the conduct of a drinking fountain designed to work with HFC (R-134a), operating with a mixture of HC's or isobutane (R-600a) without any modification to the system or the lubricating oil. In the refrigeration laboratory of Federal University of Rio Grande do Norte were installed, in a drinking fountain, temperature and pressure sensors at strategic points in the refrigeration cycle, connected to an acquisition system of computerized data, to enable the mapping and thermodynamics analysis of the device operating with R-134a or with a mixture of HC's or with R-600a. The refrigerator-test operating with the natural fluids (mixture of HC's or R-600a) had a coefficient of performance (COP) lower than the R-134a

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To evaluate how to develop dynamic hyperinflation (DH) during exercise, the influence of pursed-lip breathing in (PLB) on breathing pattern and operating volume in patients with asthma. Methods: We studied 12 asthmatic patients in three moments: (1) anthropometry and spirometry, (2) submaximal incremental cycle ergometer test in spontaneous breathing and (3), submaximal incremental test on a cycle ergometer with PLB using the Opto-electronic plethysmography. Results: Evaluating the end-expiratory lung volume (EEV) during submaximal incremental test in spontaneous breathing, patients were divided into euvolume and hyperinflated. The RFL has increased significantly, the variation of the EEV group euvolume (1.4L) and decreased in group hyperinflated (0.272L). In group volume observed a significant increase of 140% in Vt at baseline, before exercise, comparing the RFL and spontaneous breathing. Hyperinflated group was observed that the RFL induced significant increases of Vt at all times of the test incremental baseline, 50%, 100% load and 66% recovery, 250%, 61.5% and 66% respectively. Respiratory rate decreased significantly with PLB at all times of the submaximal incremental test in the group euvolume. The speed of shortening of inspiratory muscles (VtRcp/Ti) in the hyperinflated increased from 1.6 ± 0.8L/s vs. 2.55 ± 0.9L/s, whereas in the RFL euvolume group ranged from 0.72 ± 0.31L/s vs. 0.65 ± 0.2L/s. The velocity of shortening of the expiratory muscles (VtAb/Te) showed similarity in response to RFL. In group hyperinflated varied vs. 0.89 ± 0.47 vs. 0.80 ± 0.36 and ± 1.17 ± 1L vs. 0.78 ± 0.6 for group euvolume. Conclusion: Different behavior in relation to EEV in patients with moderate asthma were observed, the HD and decreased EEV in response to exercise. The breathing pattern was modulated by both RFL performance as at home, making it more efficient

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The results of dynamic instrumentation in two construction sites that used steel rails as pile foundation are presented in this paper. The first dynamic load tests were executed in piles made by single steel rails of the type TR32 and TR37. In the second group of dynamic tests, the piles were made by a composition of two and three steel rails of the same type TR37. The difficulties in placing the sensors, the effect of hammer blow eccentricity and the influence of the non-uniform welding along the pile length are presented in detail and discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Down syndrome (DS) is one of the most frequent causes of intellectual disability, affecting one in every 600 to 1000 live births. Studies have demonstrated that people with DS have a lower capacity for short-term memory (STM) and working memory (WM), which affects their capability to learn new words and to follow spoken instructions, specially when they involve multiple information or consecutive orders/orientations. It seems that the basis of the learning process, as it happens with language and mathematics comprehension and reasoning, relies in the STM and WM systems. Individuals with DS are increasingly included in mainstream education, and yet, very few researches have been conducted to investigate the influence of memory development and the type of enrollment (regular school and special school). This study investigated the relationship between the type of school enrollment with the performance on STM tests and also, the relationship of this performance with early stimulation (ES). The tests used in the first research were the digit span, free recall, word recognition and subtests of the Wechsler Intelligence Scale for Children Third Edition (WISC-III). Individuals enrolled in the regular schools group had higher scores on the digit span test and the subtests of the WISC-III. In the free recall and recognition tests, no differences were found. This study indicates that the type of enrollment might influence the memory development of individuals with DS and clearly points the need for future investigations. In the second research, the tests used were the digit span, free word recall and subtests of the WISC-III. The test results showed better performance by adults that received ES before six months of age. The studies showed improvement in STM both in people who attended or were attending regular school, as well as those who benefited from ES before six months of age. However, some issues still need to be better understood. What is the relation between this stimulation with the individual s education? Since ES may reflect a greater family involvement with the individual, what is the role of emotional components derived from this involvement in the cognitive improvement? These and other questions are part of the continuity of this study

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Toxoplasma gondii is a protozoan parasite that induces behavioral changes in rodents. The aim of this study was to evaluate the effect of infection by T. gondii during the chronic phase in working memory and impulsivity in rodents as well as the effect of antipsychotics to reverse any behavioral changes resulting from infection. Female Wistar rats (n = 40) were infected with 25 cysts of the strain ME-49 T. gondii after 4 months the animals were subjected to behavioral tests: tolerance to delay gratification, in which the animal must choose between two rewards, a smaller and more immediate, but delayed and the test of spontaneous alternation, in which the animal must use spatial cues to remember previously visited arms. Antipsychotic drugs were intraperitoneally administered during the testing of the behavioral experiments, the antipsychotic is haloperidol (1.5 mg / kg) administered 60 min before the start of the session and the antipsychotic clozapine (2.5 mg / kg) 30 min before. Animals infected with the parasite did not show operating deficits of memory, and motor impairment did not develop, however motor impairment was observed only in animals treated with haloperidol. It was found that administration of clozapine and haloperidol increased the percentage of alternation in infected and control groups in task switching espontânea.Não no distinction between control animals and infected the test of tolerance to delay gratification in relation to the percentage of choices greatest reward, during the pre-training and training, in which there is a delay of 15 s to access the great reward, however it was observed that infected animals prefer the greatest reward, when there is a delay of 30 s when compared to control group. The administration of clozapine possible that infected animals chose the greatest reward in the delay of 30 seconds during the test. These data suggest that infected mice do not exhibit deficits in working memory and that clozapine has therapeutic efficacy in improving cognitive performance of mice infected

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Millon describes the normal personality by means of adaptation styles that are effective in normal environments and personality disorders such as unadapted operating styles. To operacionalize his theoretical model, Millon has built several instruments, including the Millon Clinical Multiaxial Inventory III (MCMI-III), wich consists of a self report inventory composed by 175 true or false response items, containing four verification scales, and others scales wich evaluates 14 personality patterns and 10 clinical syndromes. The Substance Dependence scale (T) is placed along with Clinical Syndromes scales. This research is justified by the lack of a Brazilian instrument to assess personality psychopathological aspects, and aims to translate and semantically adapt the MCMI-III to the Brazilian context, checking validity elements of the Substance Dependence scale, and developing a computer application for assisting the evaluation of assessment results. To this intent, 2.588 individuals data was collected, male and female, aged between 18 and 85 years, characterized as belonging to a clinical or non-clinical group, who took part in the survey via the internet or in person. Respondents completed the MCMI-III, a socio-demographic questionnaire and a subgroup also answered to the Goldberg General Health Questionnaire (GHQ). Besides descriptive statistics, we performed the analysis using the Student t test, principal components analysis and internal consistency. Despite difficulties related to translating very specific English terms, the assessment by judges, experts on Millon´s theory, and the back translation, attested the adequacy of the Brazilian version. Factorial analysis indicated the grouping of translated T scale items into three factors (social activities prejudice, lack of impulse control, and oppositional behavior), by presenting a single item on a fourth factor (apparently related to seeking pleasurable stimuli). The Cronbach alpha for this set of items was 0,82, indicating an acceptable scale reliability. The data analysis resulted in distinction of scores between clinical and non-clinical groups and between men and women; the relationship between high scores on the scale T and the other scales; scores of drug users according to the declared used substance; and the relationship between high scores on T and the verification of disorder or risk on GHQ mental health factor, indicating the instrument´s adequate sensistivity in identifying psychopathologies and the relationship between the different disorders or psychopathological personality patterns. Although further studies are necessary to develop the scores transformation factors, the computerized correction tool was adequate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The calculation of tooth mass discrepancy, essential for good planning and a proper orthodontic finishing, when performed manually, besides being laborious, requires considerable time consumption. The aim of this study was to develop and test Bolton Freeware, a software for analysis of the tooth mass discrepancy of Bolton, aiming to minimize the consumption of time in a less onerous way. The digital analysis of the software was done by means of two-dimensional scanning of plaster study models and compared to manual evaluation (gold standard), using 75 pairs of stone plaster study models divided into two groups according to the magnitude of the Curve of Spee (group I from 0 to 2 mm, group II greater than 2 to 3mm). All the models had permanent dentition and were in perfect condition. The manual evaluation was performed with a digital caliper and a calculator, and the time required to perform the analysis for both methods was recorded and compared. In addition, the software was evaluated by orthodontists regarding its use, by means of questionnaires developed specifically for this purpose. Calibration was performed prior to manual analysis, and excellent levels of inter-rater agreement were achieved, with ICC > 0.75 and r > 0.9 for total and anterior proportion. It was observed in the evaluation of error of the digital method that some teeth showed a significant systematic error, being the highest measured at 0.08 mm. The analysis of total tooth mass discrepancy performed by Bolton Freeware, for those cases in which the curve of Spee is mild and moderate, differ from manual analysis, on average, 0.09 mm and 0.07 mm respectively, for each tooth evaluated, with r> 0, 8 for total and anterior proportion. According to the specificity and sensitivity test, Bolton Freeware has an improved ability to detect true negatives, i.e. the presence of discrepancy. The Bolton analysis digitally performed was faster, with an average difference of time consumed to perform the analysis of Bolton between the two methods of approximately 6 minutes. Most experts interviewed (93%) approved the usability of the software

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: investigar e comparar o desempenho nas habilidades relacionadas ao desenvolvimento motor, cognitivo, linguístico, de socialização e autocuidados de indivíduos com holoprosencefalia e com holoprosencefalia-like. MÉTODO: participaram deste estudo 20 indivíduos com diagnóstico de holoprosencefalia, na faixa etária de 18 a 72 meses, de ambos os sexos, divididos em 2 grupos. O grupo 1 (G1) composto por 12 indivíduos com sinais clínicos do espectro da holoprosencefalia, e o grupo 2 (G2) com holoprosencefalia-like composto por 8 indivíduos com sinais clínicos do espectro da holoprosencefalia-like. A coleta de dados foi realizada por meio da aplicação do Inventário Portage Operacionalizado que avalia as áreas alvos deste estudo. Para a análise estatística utilizou-se análise descritiva da mediana e dos valores mínimos e máximos e foi aplicado o teste estatístico de Mann Whitney (< 0,05% para significância). RESULTADOS: os grupos 1 e 2 apresentaram alterações em todas as áreas do desenvolvimento avaliadas. Entretanto, os indivíduos do G1, com holoprosencefalia apresentaram maiores comprometimentos nas habilidades: motora, cognitiva, de linguagem, de socialização e autocuidados, quanto comparados aos indivíduos do G2, com holoprosencefalia-like. CONCLUSÃO: o desempenho nas áreas motoras, cognitivas, de linguagem, de socialização e autocuidados de indivíduos com holoprosencefalia e holoprosencefalia-like foi aquém do esperado, principalmente naqueles indivíduos com holoprosencefalia, que se justifica pelo maior comprometimento no sistema nervoso central. A natureza destas alterações pode estar associada ao universo de alterações neurológicas e craniofaciais descritas nestes quadros clínicos e também à influência do ambiente social.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Determinar a acurácia das variáveis: tempo de escada (tTE), potência de escada (PTE), teste de caminhada (TC6) e volume expiratório forçado (VEF1) utilizando o consumo máximo de oxigênio (VO2máx) como padrão-ouro. MÉTODOS: Os testes foram realizados em 51 pacientes. O VEF1 foi obtido através da espirometria. O TC6 foi realizado em corredor plano de 120m. O TE foi realizado em escada de 6 lances obtendo-se tTE e PTE. O VO2máx foi obtido por ergoespirometria, utilizando o protocolo de Balke. Foram calculados a correlação linear de Pearson (r) e os valores de p, entre VO2máx e variáveis. Para o cálculo da acurácia, foram obtidos os pontos de corte, através da curva característica operacional (ROC). A estatística Kappa (k) foi utilizada para cálculo da concordância. RESULTADOS: Obteve-se as acurácias: tTE - 86%, TC6 - 80%, PTE - 71%, VEF1(L) - 67%, VEF1% - 63%. Para o tTE e TC6 combinados em paralelo, obteve-se sensibilidade de 93,5% e em série, especificidade de 96,4%. CONCLUSÃO: O tTE foi a variável que apresentou a melhor acurácia. Quando combinados o tTE e TC6 podem ter especificidade e sensibilidade próxima de 100%. Estes testes deveriam ser mais usados rotineiramente, especialmente quando a ergoespirometria para a medida de VO2máx não é disponível.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We assessed the 6-min walk distance (6MWD) and body weight x distance product (6MWw) in healthy Brazilian subjects and compared measured 6MWD with values predicted in five reference equations developed for other populations. Anthropometry, spirometry, reported physical activity, and two walk tests in a 30-m corridor were evaluated in 134 subjects (73 females, 13-84 years). Mean 6MWD and 6MWw were significantly greater in males than in females (622 ± 80 m, 46,322 ± 10,539 kg.m vs 551 ± 71 m, 36,356 ± 8,289 kg.m, P < 0.05). Four equations significantly overestimated measured 6MWD (range, 32 ± 71 to 137 ± 74 m; P < 0.001), and one significantly underestimated it (-36 ± 86 m; P < 0.001). 6MWD significantly correlated with age (r = -0.39), height (r = 0.44), body mass index (r = -0.24), and reported physical activity (r = 0.25). 6MWw significantly correlated with age (r = -0.21), height (r = 0.66) and reported physical activity (r = 0.25). The reference equation devised for walk distance was 6MWDm = 622.461 - (1.846 x Ageyears) + (61.503 x Gendermales = 1; females = 0); r2 = 0.300. In an additional group of 85 subjects prospectively studied, the difference between measured and the 6MWD predicted with the equation proposed here was not significant (-3 ± 68 m; P = 0.938). The measured 6MWD represented 99.6 ± 11.9% of the predicted value. We conclude that 6MWD and 6MWw variances were adequately explained by demographic and anthropometric attributes. This reference equation is probably most appropriate for evaluating the exercise capacity of Brazilian patients with chronic diseases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Older adults have been facing usability problems every day, and with the increasing of life expectation those issues will be more and more frequent. The study of this group capacities and limitations could help designers to project systems more usable to everyone

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BackgroundDetection and quantification of hepatitis C virus (HCV) RNA is integral to diagnostic and therapeutic regimens. All molecular assays target the viral 5'-noncoding region (59-NCR), and all show genotype-dependent variation of sensitivities and viral load results. Non-western HCV genotypes have been under-represented in evaluation studies. An alternative diagnostic target region within the HCV genome could facilitate a new generation of assays.Methods and FindingsIn this study we determined by de novo sequencing that the 3'-X-tail element, characterized significantly later than the rest of the genome, is highly conserved across genotypes. To prove its clinical utility as a molecular diagnostic target, a prototype qualitative and quantitative test was developed and evaluated multicentrically on a large and complete panel of 725 clinical plasma samples, covering HCV genotypes 1-6, from four continents (Germany, UK, Brazil, South Africa, Singapore). To our knowledge, this is the most diversified and comprehensive panel of clinical and genotype specimens used in HCV nucleic acid testing (NAT) validation to date. The lower limit of detection (LOD) was 18.4 IU/ml (95% confidence interval, 15.3-24.1 IU/ml), suggesting applicability in donor blood screening. The upper LOD exceeded 10(-9) IU/ml, facilitating viral load monitoring within a wide dynamic range. In 598 genotyped samples, quantified by Bayer VERSANT 3.0 branched DNA (bDNA), X-tail-based viral loads were highly concordant with bDNA for all genotypes. Correlation coefficients between bDNA and X-tail NAT, for genotypes 1-6, were: 0.92, 0.85, 0.95, 0.91, 0.95, and 0.96, respectively; X-tail-based viral loads deviated by more than 0.5 log10 from 5'-NCR-based viral loads in only 12% of samples (maximum deviation, 0.85 log10). The successful introduction of X-tail NAT in a Brazilian laboratory confirmed the practical stability and robustness of the X-tail-based protocol. The assay was implemented at low reaction costs (US$8.70 per sample), short turnover times (2.5 h for up to 96 samples), and without technical difficulties.ConclusionThis study indicates a way to fundamentally improve HCV viral load monitoring and infection screening. Our prototype assay can serve as a template for a new generation of viral load assays. Additionally, to our knowledge this study provides the first open protocol to permit industry-grade HCV detection and quantification in resource-limited settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To develop a new submucous fibroids classification for evaluating the viability and the degree of difficulty and complexity of a hysteroscopic myomectomy.Methods: We have included more four parameters in addition to penetration the fibroid into the myometrium. The extra-parameters were: size of the fibroid, it topography, it extension of the base in relation the wall was set and the wall it was set. The fibroids were classified according to the Classification of the European Society for Gynaecological Endoscopy (ESGE) and to the new classification (STEP-W) in patients who were submitted to hysteroscopic resection of submucous fibroids. The possibility of total resection of the fibroid, the operating time, the fluid deficit and the frequency of any complications were considered. The Fisher test, the Student t test and the analysis of variance test were used in the statistical analyses. It was considered statistically significant when the p-value was less than 0.05 in the two-tailed test.Results: In group which the hysteroscopic surgery was considered complete there was no significant difference between the three ESGE levels (0, 1 and 2). Using the STEP-W, the difference between the numbers of complete surgeries was significant (p < 0.001) for the two levels (groups I and II). The difference between the operating times was significant for the two classifications. In relation to the fluid deficit, only the STEP-W showed significant differences between the levels (p=0.02).Conclusions: It seems to us that the new classification (STEP-W) gives more clues to the difficulties of a hysteroscopic myornectomy than the standard classification (ESGE).