994 resultados para Molecular layer doping


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Biotecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exogenous agents correlated with hepatocellular carcinoma (HCC) have been identified and well characterized. These agents, including the different viruses that cause chronic hepatitis and cirrhosis, can lead to regenerative nodules and dysplastic nodules/adenomatous hyperplasia. These conditions associated with several molecular alterations of hepatocyte ultimately culminate in hepatocellular carcinoma. Recently, there has been a great progress in the identification of somatic and germinative mutations that may be correlated with the development of HCC, justifying a review on the subject. Hence, the factors involved in the process of hepatic carcinogenesis, such as infection by the hepatitis B and C viruses, with a special focus in the molecular alterations described in recent years are discussed herein, pointing out areas potentially relevant for clinical development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis for the Master degree in Structural and Functional Biochemistry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phenotypic and genotypic characteristics of Salmonella Typhi were studied in 30 strains, isolated in different years, from some areas in Brazil. Conventional typing methods were performed by biochemical tests, Vi phage-typing scheme, and antimicrobial susceptibility test. Molecular typing methods were performed by analysis of plasmid DNA and by random amplified polymorphic DNA (RAPD-PCR). For the latter, an optimization step was performed to ensure the reproducibility of the process in genetic characterization of S. Typhi. The predominance of 76.7% of biotype I (xylose +, arabinose -) was noticed in all studied areas. Three phage types were recognized, with prominence for the phage types A (73.3%) and I+IV (23.3%). All the strains were susceptible to the drugs used. However, 36.7% of the strains contained plasmids, with predominance of the 105 Kb plasmid. RAPD was capable of grouping the strains in 8 genotypic patterns using primer 784, in 6, using primer 787 and in 7, using primer 797. Conventional phenotypic typing methods, as well as the DNA plasmid analysis, presented nonsignificant discriminatory power; however, RAPD-PCR analysis showed discriminatory power, reproducibility, easy interpretation and performance, being considered as a promising alternative typing method for S. Typhi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2001, an autochthonous case of dual viremia, resulting from naturally acquired dengue virus DEN-1 and DEN-2 infections was detected during the dengue outbreak that occurred in Barretos, a city with about 105,000 inhabitants in the North region of São Paulo State. Serotype identification was based on virus isolation to C6/36 mosquito cells culture and immunofluorescence assays using type-specific monoclonal antibodies. The double infection was also confirmed by reverse transcriptase polymerase chain reaction (RT-PCR). Comparative analysis of the 240-nucleotide sequences of E/NS1 gene junction region between the genome of DEN-1 and DEN-2 isolates of the corresponding reference Nauru and PR 159S1 strains, respectively, showed some nucleotide differences, mainly silent mutations in the third codon position. Results of maximum likelihood phylogenetic analysis of E/NS1 gene sequences indicated that both genotypes of DEN-1 and DEN-2 viruses recovered from double infection in Barretos belonged to genotypes I and III, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strain typing is a critical tool for molecular epidemiological analysis and can provide important information about the spread of dengue viruses. Here, we performed a molecular characterization of DEN-2 viruses isolated in Brazil during 1990-2000 from geographically and temporally distinct areas in order to investigate the genetic distribution of this serotype circulating in the country. Restriction site-specific polymerase chain reaction (RSS)-PCR presented the same pattern for all 52 Brazilian samples, showing the circulation of just one DEN-2 variant. Phylogenetic analysis using progressive pairwise alignments from 240-nucleotide sequences of the E/NS1 junction in 15 isolates showed that they belong to genotype III (Jamaica genotype).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In São Paulo State, Brazil, the epidemic increase in isolation of Salmonella Enteritidis has been observed since 1994. A total of 105 S. Enteritidis strains (72 from human and 33 from non-human sources) isolated during the period 1975-1995, previously characterized by phage typing, was analyzed by antimicrobial susceptibility, plasmid profile, and ribotyping. Over 70% of the strains were susceptible to all antimicrobial agents tested, however, multiple resistance to antimicrobials was observed among the studied strains, mainly those from hospitalized patients. Phage type 8 (PT-8) was predominant among the strains isolated during the period of 1975-1992, but in the following years, PT-4 was the most frequent phage type identified. Seven different plasmid profiles were detected and 96% of the isolates harbored a plasmid of approximately 36 MDa. Ribotyping discriminated fourteen ribotypes (R1 to R14) among the strains examined. By analysis of dendrogram the strains were included in three groups with similarity level of 60%. The obtained results indicate that, a single ribotype (R11), determined for PT-4 strains isolated from 1993, characterizes the epidemic clone of S. Enteritidis in our region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A. lumbricoides has been associated to the ABO System by various authors. The objective was to detect ABO System epitopes in A. lumbricoides of groups O, A, B and AB patients. 28 adult parasites were obtained from children to be used as assay material. The patients ABO blood groups were determined. Extracts of A. lumbricoides [AE] were prepared by surgical remotion of the cuticle and refrigerated mechanical rupture. Agglutination Inhibition (AI) and Hemoagglutination Kinetics (HK) tests were used with the [AE]. Of the 28 [AE], eight belonged to O group patients, 15 to A group, three to B group and the remaining two to AB children. The AI Test showed A epitopes in two [AE] of group A patients and B epitopes in two [AE] of group B patients. The HK Test showed B antigenic determiners in two [AE] of group B patients and in two [AE] of group AB patients as well as A antigenic determiners in one [AE] of A group patient. Of the 28 [AE] studied in both tests B epitopes were detected in all [AE] from B and AB patients and A epitopes in three of the 15 [AE] of group A patients. The experiments carried out suggest that A. lumbricoides might absorb A and B antigens from the host, and/or modify the cuticular carbohydrates expression as a kind of antigenic mimicry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biomimetics has paved the way toward new materials and technologies inspired in Nature. Biomolecules and their supramolecular organization have today a leading role in biomimetics, benefiting from the recent advances in nanotechnology. The production of biomimetic materials may be however a difficult task, because Nature does it very well. The use of several building blocks assembled in bottom-up arrangement is without doubt at the core of this process. Such building blocks include different molecules or molecular arrangements, of synthetic or natural origin, such as amino acids, lipids, carbohydrates, nucleic acids, carbon allotropes, dendrimers, or organosilanes, among others. The most common approaches to produce synthetic biomimetic materials are reported herein, with special emphasis to building blocks and their supramolecular arrangement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

6th Graduate Student Symposium on Molecular Imprinting

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel reusable molecularly imprinted polymer (MIP) assembled on a polymeric layer of carboxylated poly(vinyl chloride) (PVCsingle bondCOOH) for myoglobin (Myo) detection was developed. This polymer was casted on the gold working area of a screen printed electrode (Au-SPE), creating a novel disposable device relying on plastic antibodies. Electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and Fourier transform infrared spectroscopy (FTIR) studies confirmed the surface modification. The MIP/Au-SPE devices displayed a linear behaviour in EIS from 0.852 to 4.26 μg mL−1, of positive slope 6.50 ± 1.48 (kΩ mL μg−1). The limit of detection was 2.25 μg mL−1. Square wave voltammetric (SWV) assays were made in parallel and showed linear responses between 1.1 and 2.98 μg mL−1. A current decrease was observed against Myo concentration, producing average slopes of −0.28 ± 0.038 μA mL μg−1. MIP/Au-SPE also showed good results in terms of selectivity. The error% found for each interfering species were 7% for troponin T (TnT), 11% for bovine serum albumin (BSA) and 2% for creatine kinase MB (CKMB), respectively. Overall, the technical modification over the Au-SPE was found a suitable approach for screening Myo in biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work introduces two major changes to the conventional protocol for designing plastic antibodies: (i) the imprinted sites were created with charged monomers while the surrounding environment was tailored using neutral material; and (ii) the protein was removed from its imprinted site by means of a protease, aiming at preserving the polymeric network of the plastic antibody. To our knowledge, these approaches were never presented before and the resulting material was named here as smart plastic antibody material (SPAM). As proof of concept, SPAM was tailored on top of disposable gold-screen printed electrodes (Au-SPE), following a bottom-up approach, for targeting myoglobin (Myo) in a point-of-care context. The existence of imprinted sites was checked by comparing a SPAM modified surface to a negative control, consisting of similar material where the template was omitted from the procedure and called non-imprinted materials (NIMs). All stages of the creation of the SPAM and NIM on the Au layer were followed by both electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). AFM imaging was also performed to characterize the topography of the surface. There are two major reasons supporting the fact that plastic antibodies were effectively designed by the above approach: (i) they were visualized for the first time by AFM, being present only in the SPAM network; and (ii) only the SPAM material was able to rebind to the target protein and produce a linear electrical response against EIS and square wave voltammetry (SWV) assays, with NIMs showing a similar-to-random behavior. The SPAM/Au-SPE devices displayed linear responses to Myo in EIS and SWV assays down to 3.5 μg/mL and 0.58 μg/mL, respectively, with detection limits of 1.5 and 0.28 μg/mL. SPAM materials also showed negligible interference from troponin T (TnT), bovine serum albumin (BSA) and urea under SWV assays, showing promising results for point-of-care applications when applied to spiked biological fluids.