955 resultados para Liquid-chromatographic Determination


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Total neutron scattering has been used to follow the hydrogenation of toluene-d8 to methylcyclohexane-d14 over 3 wt% platinum supported on highly ordered mesoporous silica (MCM-41) at 298 K and under 150 mbar D2 pressure. The detailed kinetic information so revealed indicates that liquid reorganisation inside pores is the slowest step of the whole process. Additionally, the results were compared with the reaction performed under 250 mbar D2 pressure as well as with toluene-h8 hydrogenation using D2 at 150 mbar.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[EN]Policyclyc aromatic hydrocarbons (PAHs) are a potential risk for human health and marine biota in general that make necessary the monitorization of them. A miniaturized extraction system capable to extract PAHs from seawater was developed and optimized with the objective of implement it in an oceanographic buoy in the future. An analytical method was optimized by high performance liquid chromatography for the determination of extracted PAHs by the extraction system. The analytical method was validated and applicated to real samples of differents points of Gran Canaria. The method has enough sensitivity to detect and quantify concentrations below the concentrations established in the legislation. In some places where samples were taken some compounds exceed the legislation while other compounds follow it

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Chemical speciation in foodstuffs is of uttermost importance since it is nowadays recognized that both toxicity and bioavailability of an element depend on the chemical form in which the element is present. Regarding arsenic, inorganic species are classified as carcinogenic while organic arsenic, such as arsenobetaine (AsB) or arsenocholine (AsC), is considered less toxic or even non-toxic. Coupling a High Performance Liquid Chromatographer (HPLC) with an Inductively Coupled Plasma Mass Spectrometer (ICP-MS) combines the power of separation of the first with the selectivity and sensitivity of the second. The present work aims at developing a method, using HPLC-ICP-MS technique, to identify and quantify the chemical species of arsenic present in two food matrices, rice and fish. Two extraction methods, ultrasound and microwave, and different settings were studied. The best method was chosen based on recovery percentages. To ensure that no interconversion of species was occurring, individual spikes of each species of arsenic were made in both matrices and recovery rates were calculated. To guaranty accurate results reference material BCR-627 TUNA FISH, containing certified values for AsB and DMA, was analyzed. Chromatographic separation was achieved using an anion exchange column, HAMILTON-PRP X-100, which allowed to separate the four arsenic species for which standards were available (AsB, dimethylarsenic (DMA), arsenite (AsIII), arsenate (AsV). The mobile phase was chosen based on scientific literature and adjusted to laboratory conditions. Different gradients were studied. As a result we verified that the arsenic species present in both matrices were not the same. While in fish 90% of the arsenic present was in the form of arsenobetaine, in rice 80% of arsenic was present as DMA and 20% as inorganic arsenic.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Isocyanates are included into a class with an extreme commercial importance because their use in the manufacture of polyurethanes. Polyurethanes are used in several applications such as adhesives, coatings, foams, thermoplastics resins, printing inks, foundry moulds and rubbers. Agglomerated cork stoppers are currently used for still wines, semi-sparkle and gaseous wines, beer and cider. Methylene diphenyl diisocyanate (MDI) is presently the isocyanate used in the production of polyurethane based adhesive in use due to its lowest toxicity comparing with toluene diisocyanate (TDI) previously employed. However, free monomeric TDI or MDI, depending on the based polyurethane, can migrate from agglomerated cork stoppers to beverages therefore it needs to be under control. The presence of these compounds are usually investigated by HPLC with Fluorescence or UV-Vis detector depending on the derivatising agent. Ultra Performance Liquid Chromatography with Diode Array Detector (UPLC-DAD) method is replacing HPLC. The objective of this study is to determine which method is better to analyze isocyanates from agglomerated cork stoppers, essentially TDI to quantify its monomer. A Design of Experiments (DOE) with three factors, column temperature, flow and solvent, at two levels was done. Eight experiments with three replications and two repetitions were developed. Through an ANOVA the significance of the factors was evaluated and the best level’s factors were selected. As the TDI has two isomers and in this method these two isomers were not always separated an ANOVA with results of resolution between peaks was performed. The Design of Experiments reveals to be a suitable statistical tool to determine the best conditions to quantified free isocyanates from agglomerated cork stoppers to real foodstuff. The best level’s factors to maximize area was column temperature at 30ºC, flow to 0,3 mL/min and solvent 0,1% Ammonium Acetate, to maximize resolution was the same except the solvent that was 0,01% Ammonium Acetate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The southern region of Brazil, especially the states of Parana and Santa Catarina stand out for growing grapes and apples for fresh consumption and in order to add value to these products, process the material for the production of wine, juices and jellies . As a result large quantities of by-products, such as peels, seeds and pulp are produced becoming environmental problems. Studies reuse of these by-products have attracted interest because they have shown a high biological potential, due to the presence of high levels of phenolic compounds, which are associated with a lower incidence of disease caused by oxidative stress, due to its antioxidant, antiinflammatory and antibacterial properties. Currently, few studies are presented on the phenolic composition and biological potential of waste grape variety Bordô (Vitis labrusca) and apple (Malus domestica) Gala variety, cultivated in southern Brazil. Within this context, the objectives of this study were: compare the efficiency of solidliquid and liquid-liquid extraction, perform the optimization and validation of analytical methodology by HPLC-DAD for the separation, identification and quantification of multiclass phenolic compounds, evaluate the activity antioxidant by sequestering methods of free radical 2,2-diphenyl-1 picrilhidrazina (DPPH) and 2,2-azino-bis (3- ethyl-benzthiazoline-6-sulphonic acid) (ABTS) solution, reduction of Fe3+ in Fe2+ method (FRAP), ORAC, RP-HPLC-ABTS online, Rancimat and determination of total phenolics three agro-industrial byproducts, pomace and stems grape Bordô produced in Paraná Southwest region and Gala apple pomace coming from the Santa Catarina West. Optimization and validation of chromatographic method showed satisfactory quality parameters for the compounds of interest and the solidliquid extraction was more efficient in extracting phenolic evaluated. The three byproducts evaluated showed significant levels of phenolic compounds when analyzed by HPLC, especially flavonoids, catechin and epicatechin besides that showed significant antioxidant capacity. The grape stems extract had the highest sequestration capacity of DPPH and ABTS radical and reduced iron, and high content of phenolic compounds. The apple pomace extract showed the best response to the Rancimat method, which indicates a high potential to protect the oil from lipid oxidation, was no significant difference when compared to synthetic antioxidant TBHQ. The results of this study showed that the agro-industrial coproducts analyzed are rich in phenolic compounds of high antioxidant capacity and therefore must be better explored by the food and pharmaceutical industries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The routine analysis for quantization of organic acids and sugars are generally slow methods that involve the use and preparation of several reagents, require trained professional, the availability of special equipment and is expensive. In this context, it has been increasing investment in research whose purpose is the development of substitutive methods to reference, which are faster, cheap and simple, and infrared spectroscopy have been highlighted in this regard. The present study developed multivariate calibration models for the simultaneous and quantitative determination of ascorbic acid, citric, malic and tartaric and sugars sucrose, glucose and fructose, and soluble solids in juices and fruit nectars and classification models for ACP. We used methods of spectroscopy in the near infrared (Near Infrared, NIR) in association with the method regression of partial least squares (PLS). Were used 42 samples between juices and fruit nectars commercially available in local shops. For the construction of the models were performed with reference analysis using high-performance liquid chromatography (HPLC) and refractometry for the analysis of soluble solids. Subsequently, the acquisition of the spectra was done in triplicate, in the spectral range 12500 to 4000 cm-1. The best models were applied to the quantification of analytes in study on natural juices and juice samples produced in the Paraná Southwest Region. The juices used in the application of the models also underwent physical and chemical analysis. Validation of chromatographic methodology has shown satisfactory results, since the external calibration curve obtained R-square value (R2) above 0.98 and coefficient of variation (%CV) for intermediate precision and repeatability below 8.83%. Through the Principal Component Analysis (PCA) was possible to separate samples of juices into two major groups, grape and apple and tangerine and orange, while for nectars groups separated guava and grape, and pineapple and apple. Different validation methods, and pre-processes that were used separately and in combination, were obtained with multivariate calibration models with average forecast square error (RMSEP) and cross validation (RMSECV) errors below 1.33 and 1.53 g.100 mL-1, respectively and R2 above 0.771, except for malic acid. The physicochemical analysis enabled the characterization of drinks, including the pH working range (variation of 2.83 to 5.79) and acidity within the parameters Regulation for each flavor. Regression models have demonstrated the possibility of determining both ascorbic acids, citric, malic and tartaric with successfully, besides sucrose, glucose and fructose by means of only a spectrum, suggesting that the models are economically viable for quality control and product standardization in the fruit juice and nectars processing industry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last decades, the effects of the air pollution have been increasing, especially in the case of the human health diseases. In order to overcome this problem, scientists have been studying the components of the air. As a part of water-soluble organic compounds, amino acids are present in the atmospheric environment as components of diverse living organisms which can be responsible for spreading diseases through the air. Liquid chromatography is one technique capable of distinguish the different amino acids from each other. In this work, aiming at separating the amino acids found in the aerosols samples collected in Aveiro, the ability of four columns (Mixed-Mode WAX-1, Mixed-Mode HILIC-1, Luna HILIC and Luna C18) to separate four amino acids (aspartic acid, lysine, glycine and tryptophan) and the way the interaction of the stationary phases of the columns with the analytes is influenced by organic solvent concentration and presence/concentration of the buffer, are being assessed. In the Mixed-Mode WAX-1 column, the chromatograms of the distinct amino acids revealed the separation was not efficient, since the retention times were very similar. In the case of lysine, in the elution with 80% (V/V) MeOH, the peaks appeared during the volume void. In the Mixed-Mode HILIC-1 column, the variation of the organic solvent concentration did not affect the elution of the four studied amino acids. Considering the Luna HILIC column, the retention times of the amino acids were too close to each other to ensure a separation among each other. Lastly, the Luna C18 column revealed to be useful to separate amino acids in a gradient mode, being the variation of the mobile phase composition in the organic solvent concentration (ACN). Luna C18 was the column used to separate the amino acids in the real samples and the mobile phase had acidified water and ACN. The gradient consisted in the following program: 0 – 2 min: 5% (V/V) ACN, 2 – 8 min: 5 – 2 % (V/V) ACN, 8 – 16 min: 2% (V/V) ACN, 16 – 20 min: 2 – 20 % (V/V) ACN, 20 – 35 min: 20 – 35 % (V/V) ACN. The aerosols samples were collected by using three passive samplers placed in two different locations in Aveiro and each sampler had two filters - one faced up and the other faced down. After the sampling, the water-soluble organic compounds was extracted by dissolution in ultra-pure water, sonication bath and filtration. The resulting filtered solutions were diluted in acidified water for the chromatographic separation. The results from liquid chromatography revealed the presence of the amino acids, although it was not possible to identify each one of them individually. The chromatograms and the fluorescence spectra showed the existence of some patterns: the samples that correspond to the up filters had more intense peaks and signals, revealing that the up filters collected more organic matter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A preocupação com a poluição das águas por agrotóxicos tem aumentado, visto que aumentou o número de detecções de agrotóxicos em águas. A falta de avaliação da qualidade da água consumida pela população de áreas rurais onde não existe o abastecimento público de água potável, deve ser considerada, pois essas águas se encontram próximo a áreas de cultivo, onde há intensa aplicação de agrotóxicos. Nessas regiões, o abastecimento de água para as residências e para a irrigação é feito geralmente através das águas de poços. Neste trabalho, um método para determinação dos agrotóxicos carbofurano, clomazona, 2,4-D e tebuconazol em água subterrânea foi desenvolvido e validado. O método utilizou a Extração em Fase Sólida (SPE) e determinação por Cromatografia Líquida de Alta eficiência com Detecção por Arranjo de Diodos (HPLC-DAD) e confirmação por Cromatografia Líquida tandem Espectrometria de Massas (LC-MS/MS). Para a SPE utilizou-se cartuchos C18 de 200 mg, e eluição com 1 mL de metanol. Após a otimização dos parâmetros de extração e separação dos compostos, o método foi validado avaliando-se curva analítica, linearidade, limites de detecção e quantificação, precisão (repetitividade e precisão intermediária) e exatidão (recuperação). Todas as curvas analíticas apresentaram valores de r maiores que 0,99. Os LOQs para o método, considerando a etapa de pré-concentração de 250 vezes, foram de 0,2 µg L -1 para todos os agrotóxicos por HPLC-DAD e, por LC-MS/MS, 4,0 ng L -1 para clomazona, carbofurano e tebuconazol e de 40,0 ng L -1 para 2,4-D. As recuperações foram entre 60,3 e 107,7% para a repetitividade e entre 67,5 e 115,3% para a precisão intermediária, com RSD de 0,8 a 20,7% para todos os compostos por HPLC-DAD. Para o LC-MS/MS a precisão em termos de repetitividade, variou entre 0,97 e 20,7%, e as recuperações entre 67,0 e 108,9%. O método foi aplicado na determinação de agrotóxicos em amostras de águas subterrâneas durante um ano. Nas amostras foram detectados agrotóxicos em níveis de µg L -1 . Dentro do contexto atual da Química Analítica, de desenvolver métodos mais rápidos, que utilizem menor quantidade de solvente, de amostra e com altos fatores de enriquecimento, foi otimizado um método de extração para os agrotóxicos carbofurano, clomazona e tebuconazol utilizando a Microextração Líquido-Líquido Dispersiva (DLLME) e determinação por LC-MS/MS. Foram otimizados alguns parâmetros que influenciam no processo de extração, como: tipo e volume dos solventes dispersores e extratores, tempo de extração, força iônica e velocidade de centrifugação. Nas condições otimizadas, as recuperações para os níveis de concentração entre 0,02 e 2,0 g L -1 variaram entre 62,7 e 120,0%, com valores de RSD entre 1,9 e 9,1%. O LOQ do método foi de 0,02 µg L -1 para todos os compostos. Quando comparado com a SPE se demonstrou rápido, simples, de baixo custo, além de necessitar de menores volumes de amostra para determinação de agrotóxicos em águas. O método mostrou-se adequado à análise dos agrotóxicos em água subterrânea e todos os parâmetros de validação obtidos estão dentro dos limites sugeridos para validação de métodos cromatográficos

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O Rio Grande Sul destaca-se no cenário nacional como grande produtor de diversas culturas, as quais demandam grande quantidade de agrotóxicos das mais diversas classes químicas e toxicidades. No entanto a intensa utilização destes compostos torna-se uma preocupação devido a possíveis contaminações das águas superficiais e subterrâneas. Em virtude da degradação dos mananciais a água mineral passou a ser uma das fontes mais utilizadas para o consumo humano, pois tem-se a percepção de que a mesma possui melhor qualidade que a água tratada, além disso acredita-se que a mesma esta isenta de substâncias orgânicas prejudiciais à saúde humana. Neste trabalho, foi realizada a determinação dos agrotóxicos atrazina, simazina, imazapique, imazetapir, imidacloprido, ciproconazol, tebuconazol e epoxiconazol em água mineral empregando a Microextração Líquido-Líquido Dispersiva (DLLME), Microextração Líquido-Líquido Dispersiva com Solidificação da Gota Orgânica Flutuante (DLLME-SFO) e Cromatografia Líquida acoplada à Espectrometria de Massas em série com fonte de ionização por Eletronebulização (LC-ESI-MS/MS). Para o método empregando DLLME e LC-ESI-MS/MS foram otimizados alguns fatores como o tipo e volume de solvente extrator e dispersor e pH. Após a otimização dos parâmetros de extração, fragmentação dos compostos e separação cromatográfica, o método foi validado avaliando-se curva analítica, linearidade, limites de detecção e quantificação, precisão (repetitividade e precisão intermediária) e exatidão (recuperação). Todas as curvas analíticas apresentaram valores de r maiores que 0,999. Os Limites de Quantificação (LOQs) para o método estiveram na faixa de 5 a 500 ng L-1. Foram obtidas recuperações entre 102 - 120% para a repetibilidade e entre 92 e 110% para a precisão intermediária, com RSD de 2 a 10% para todos os compostos. Para o método empregando DLLME-SFO e LC-ESI-MS/MS foram avaliados alguns parâmetros que afetam a eficiência da extração como, tipo e volume de solvente extrator e dispersor, força iônica e pH. Nas condições ótimas de extração todas as curvas analíticas apresentaram valores de r maiores que 0,997. Os LOQs para o método variaram entre 12,5 - 125 ng L-1. As recuperações foram entre 70 e 118% para a repetitividade e entre 76 e 95% para a precisão intermediária, com RSD de 2 a 18% para todos os compostos. Com relação ao Efeito Matriz (EM) avaliado para todos os compostos pelos dois métodos, foi observado baixo EM. Isso indicou que não é necessário utilizar a curva analítica preparada no extrato branco da matriz para a quantificação destes analitos. Ambos os métodos foram aplicados para a determinação de resíduos de agrotóxicos em amostras de água mineral provenientes de diferentes regiões do estado do Rio Grande do Sul e não foram encontrados resíduos de agrotóxicos nas amostras analisadas. Os métodos validados apresentaram como principais vantagens baixo consumo de solventes orgânicos e amostra, rapidez, altos fatores de concentração e recuperações dentro da faixa aceitável. Os limites de quantificação dos métodos ficaram abaixo dos limites máximos de resíduos permitidos pela legislação brasileira para agrotóxicos em água mineral.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The antioxidant potential of mushrooms is mainly attributed to their composition in polysaccharides, phenolic compounds, tocopherols and some organic acids [1]. Phenolic compounds contribute directly to the antioxidative action and play an important role in stabilizing lipid peroxidation [2]; exhibit a wide range of bioactive properties such as anti-allergenic, anti-inflammatory and antimicrobial, which have been in part related to their antioxidant activity [3]. Tocopherols are important fatsoluble antioxidants, acting in the cellular membrane; due to their role as scavenger of free radicals protecting human cells against degenerative malfunctions [4]. Some organic acids are very common in natural matrices; malic acid contributes to a pleasantly sour taste and is often used as a food additive; citric acid is known due to its antibacterial and antioxidant properties and fumaric acid is important because of its antioxidant, anti-inflammatory, antimicrobial and acidifying properties [5]. The purpose of the present study was to analyze antioxidant and related compounds (phenolic compounds, tocopherols and organic acids) of Polyporus squamosus (Huds.) Fr. samples originated from two different origins (Portugal and Serbia). Specimens of P. squamosus were collected in Bragança (Northeast Portugal) and Jabučki rit (Northern Serbia) during April 2015 and 2012, respectively. Phenolic compounds, organic acids and tocopherols were determined by high performance liquid chromatograph (HPLC) coupled to a diode array detector (DAD), in the two first cases, and a fluorescence detector in the last one. With respect to phenolic and related compounds, p-hydroxybenzoic and cinnamic acids were identified in both samples; the first one predominates in the sample from Portugal, while cinnamic acid was more abundant in the sample from Serbia. Tocopherols (α-, β and γ-isoforms) were found in the sample from Serbia, but in the sample from Portugal, γ-tocopherol was not identified. This sample showed the highest total tocopherols content, and revealed the highest level of β-tocopherol; γ- tocopherol predominated in the sample from Serbia. Among organic acids, it was possible to quantify oxalic, malic and fumaric acids in both samples. Malic acid was found in higher amounts in the sample from Serbia. Overall, the present study shows that mushroom samples from different origins have dissimilar results, but are both rich in bioactive compounds, being a valuable source for the development of natural medicines and nutraceuticals.