970 resultados para GAS-CHROMATOGRAPHY


Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work, the organic compounds of cigar samples from different brands were analyzed. The compound extraction was made using the matrix solid-phase dispersion (MSPD) technique, followed by gas chromatography and identification by mass spectrometry (GC-MS) and standards, when available. Thirty eight organic compounds were found in seven different brands. Finally, with the objective of characterizing and discriminating the cigar samples, multivariate statistical analyses were applied to data, e.g.; principal component analysis (PCA) and hierarchical cluster analysis (HCA). With such analyses, it was possible to discriminate three main groups of three quality levels.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present work describes the determination of polychlorinated biphenyls in 123 umbilical cord serum samples by liquid-liquid extraction method with acid hydrolyze step and analysis by GC-mECD. The analytical method was evaluated with following figures of merit for all PCBs: linearity (>0.997); precision (<12.55%); recoveries (73-119%); limit of detection (0.1 ng mL-1); limit of quantification (0.25-0.5 ng mL-1). The results showed high contamination in the analyzed samples. PCB more frequent was 138 (66.7%), followed by 180 (55.3%) and 52 (51.3%).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A fruit chemical composition reflects its maturation stage. For coffee, it is also the reflex of the post-harvesting processing type, dry, semi-wet and wet. The object of this work was to verify if headspace solid phase microextraction coupled to gas chromatography (HS-SPME-GC) could be used to discriminate between samples harvested in different maturation stages and treated by different processes. With application of principal component analysis to the area of 117 compounds extracted by SPME, using divinylbenzene/Carboxen/polydimethylsiloxane fiber, it was possible to discriminate, in the roasted and ground coffee, the maturity stage and processing type used .

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Analysis of seven pesticides in sediments was successfully achieved using comprehensive two-dimensional gas chromatography with micro-electron capture detection, as it provided higher sensitivity and less matrix interference. Repeatability and intermediate precision of peak areas and heights were less than 4% and the recovery percentage for the analytes ranged from 52 to 115%. Instrumental LOD and LOQ were in the range of 0.60 to 2.31 μg L-1 and 1.83 to 5.62 μg L-1, respectively. Concentrations of 3.34 μg kg-1 (dry basis) for trifloxystrobin and azoxystrobin (below the LOQ) were found in a sediment sample.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A method based on headspace - solid phase microextraction coupled with gas chromatography - mass spectrometry was validated for the quantitative determination of 18 organochlorine pesticides in water. For the extraction conditioning some parameters as the best type of coating fiber, time and temperature of extraction, pH and ionic strength were evaluated. The method HS-SPME/GC-MS/MS showed linear coefficient above 0.9948. The repeatability of the measurements were lower than 7.6%. Relative recoveries were between 88 and 110%. Limits of detection from 0.5 x 10-3 to 1.0 mg L-1 were obtained. A total of 31 samples were analyzed and 16 presented from 1 to 5 pesticides.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aromatic compounds are still poorly evaluated in geochemical studies of Brazilian oil samples. For this reason, the objective of this work was to analyze and evaluate 26 oil samples from four Brazilian sedimentary basins. Aromatic hydrocarbon fractions have been analyzed by gas chromatography coupled to mass spectrometry. The results were also compared with previously evaluated saturated hydrocarbon data. Maturation parameters obtained using the 4- and 1-methyl-dibenzothiophenes and trimethyl-dibenzothiophenes led to the best results because a better grouping was observed. For this correlation, the samples were grouped by maturity degree enabling the routine use of these parameters to evaluate oil maturity levels.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Genetic algorithm and partial least square (GA-PLS) and kernel PLS (GA-KPLS) techniques were used to investigate the correlation between retention indices (RI) and descriptors for 117 diverse compounds in essential oils from 5 Pimpinella species gathered from central Turkey which were obtained by gas chromatography and gas chromatography-mass spectrometry. The square correlation coefficient leave-group-out cross validation (LGO-CV) (Q²) between experimental and predicted RI for training set by GA-PLS and GA-KPLS was 0.940 and 0.963, respectively. This indicates that GA-KPLS can be used as an alternative modeling tool for quantitative structure-retention relationship (QSRR) studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recycling of paper in industrial scale has become an established practice worldwide. In this work, organic compositions of three different kinds of sludge generated in recycle paper industry were studied, and the incorporation of one of those sludge in briket was also investigated. The characterization of organic compounds in sludge samples and briket was performed using Gas Chromatography coupled with Mass Spectrometry after a Soxhlet extraction. Different chemical classes were identified in each type of sludge, but just the sludge composed by cellulose residue did not presented polyaromatic hydrocarbons. Four formulations of sludge incorporated with charcoal for briket production were evaluated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The analysis of fatty acid (FA) esters by gas chromatography and flame ionization detector (FID) normally uses the normalization method. However, if one FA is wrongly estimated, the results could be greatly affected. In this study, methodologies using internal standards and correction factors for the FID response are described. The results show that by using theoretical correction factors associated to the internal standardization, the quantitative analyses of the FAs are expressed in mass, increasing the accuracy and facilitating the interpretation and comparison of the results for foods and biodiesels.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes an undergraduate experiment for the synthesis of Knoevenagel adduct of Meldrum's acid with nine aromatic aldehydes, using water as the solvent, in an adaptation of a previously reported synthetic protocol. The synthesis was straightforward, requiring a period of two hours, and is suitable for undergraduate experimental courses on green chemistry. In addition, quantitative analyses of the relative reactivity of p-nitro-benzaldehyde and p-metoxi-benzaldehyde was evaluated through the competitive reaction of equimolar amounts of these aldehydes with one equivalent of Meldrum's acid, using gas chromatography to quantify the composition of the reaction mixture.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present research aimed to study the parameters that affect the determination of estrogens in sewage upon the use of SPE and determination by using gas chromatography mass spectrometry (GC/MS). The study evaluated the stabilization pond technology with regard to estrogens removal. The results showed that the methodology was able to identify and quantify the estrogens E1, E2, E2-17A and EE2 in sewage. Moreover, the estrogens sometimes were not removed in the stabilization pond, showing that even the high hydraulic retention time (HRT) and high sunlight intensity were not enough to degrade these compounds completely during load peaks.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple and fast method for determination of 40 basic drugs in human plasma employing gas-chromatography with nitrogen-phosphorus detection was developed and validated. Drugs were extracted from 800 µL of plasma with 250 µL of butyl acetate at basic pH. Aliquots of the organic extract were directly injected on a column with methylsilicone stationary phase. Total chromatographic run time was 25 min. All compounds were detected in concentrations ranging from therapeutic to toxic levels, with intermediate precision CV% below 11.2 and accuracy in the range of 92-114%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Brazilian petroleum is known by its high acidity due to the presence of acidic constituents, especially naphthenic acids (NA). The total characterization of the NA in petrochemical samples has been receiving special attention in research and comprises an analytical challenge, mainly due to the complexity of their mixtures. Gas chromatography with mass detector (GC/MS) is the technique of analysis more used, but recently comprehensive two-dimensional gas chromatography (GC × GC) has been used, due to its high resolution, peak capacity and sensitivity. The goal of this article is to discuss the techniques for sample preparation and analysis of NA in petroleum.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper describes selective molecularly imprinted solid-phase extraction of ttMA from urine samples followed by derivatization and analysis by gas chromatography/mass spectrometry (GC/MS). The analytical calibration curve ranged from 0.3 to 7.0 mg L-1 (r = 0.999) and the limit of quantitation (LOQ) was 0.3 mg L-1. The method was applied for the determination of ttMA in urine samples from smokers and concentrations detected ranged from < LOQ to 1.64 mg L-1. Thus, the proposed method proved adequate for the determination of urinary ttMA in the biomonitoring of occupational exposure to low levels of benzene.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The estimation of measurement uncertainty of an analytical result is an important tool to be applied for compliance to ISO IEC 17025. Through the available guides it is possible to establish procedures and criteria for the estimation of measurement uncertainty. This paper presents a case study on the estimation of measurement uncertainty in migration the test of ε-caprolactam from the polyamide 6 packages to fatty foods with determination by GC-FID. The calculation methodology used for the estimation of measurement uncertainty for the migration test was developed based on the guides EURACHEM / CITAC and ISO GUM, taking into account relevant aspects of the migration test. The expanded uncertainty estimated was approximately 23% of the concentration of migration.