924 resultados para Design Thinking Strategy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Imunoglobulin (Ig) and T cell receptor (TCR) gene rearrangements function as specific markers for minimal residual disease (MRD) which is one of the best predictors of outcome in childhood acute lymphoblastic leukemia (ALL) We recently reported on the prognostic value of MRD during the induction of remission through a simplified PCR method Here we report on gene rearrangement frequencies and offer guidelines for the application of the technique Procedure Two hundred thirty three children had DNA extracted from bone marrow Ig and TCR gene rearrangements were amplified using consensus primers and conventional PCR PCR products were submitted to homo/heteroduplex analysis A computer program was designed to define combinations of targets for clonal detection using a minimum set of primers and reactions Results At least one clonal marker could be detected in 98% of the patients and two markers in approximately 80% The most commonly rear ringed genes in precursor B cell ALL were IgH (75%) TCRD (59%) IgK (55%), and TCRG (54%) The most commonly rearranged genes for TALL were TCRG (100%) and TCRD (24%) The sensitivity of primers was limited to the detection of 1 leukemic cell among 100 normal cells Conclusions We propose that eight PCR reactions per ALL subtype would allow for the detection of two markers in most cases In addition these reactions ire suitable for MRD monitoring especially when aiming the selection of patients with high MRD levels (>= 10(-2)) at the end of induction therapy Such an approach would be very useful in centers with limited financial resources Pediatr Blood Cancer 2010 55 1278-1286 (C) 2010 Wiley Liss Inc

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to assess the influence of adhesive area delimitation on the microshear bond strength of different adhesives to dentin. Materials and Methods: Eighteen bovine incisors were sectioned and the exposed dentin surfaces were prepared with 600-grit SIC paper. These teeth were randomly divided into three groups, according to the adhesive to be applied: two-step etch-and-rinse Adper Single Bond 2 (3M ESPE), two-step self-etching Clearfil SE Bond (Kuraray), and one-step Clearfil S(3) Bond (Kuraray). On each dentin surface, 4 samples were built up with the composite resin Z100 (3M ESPE); on 2 of these, a suggested area delimitation technique was employed. After 24 h of storage in water at 37 degrees C, samples were subjected to the microshear bond strength test, and the failure modes were evaluated under optical and scanning electron microscopes. The obtained results were statistical analyzed using two-way ANOVA and Tukey`s test. Results: Groups without area delimitation presented significantly higher bond strength results (p < 0.05) and a higher incidence of cohesive failures. In these groups, fractures tended to occur beyond the limits of the actual adhesive area, while the area restriction technique succeeded in avoiding this phenomenon. The three adhesives performed similarly when area delimitation was employed (p > 0.05), but Clearfil S(3) Bond showed significantly higher bond strength results when no area delimitation was taken into account (p < 0.05). Conclusion: The extension of the adhesive area beyond the limits of the composite cylinder may play an important role in the results of microshear bond strength tests, while the suggested area delimitation technique may lead to less questionable outcomes.