996 resultados para CM-choke


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The most common laparoscopic complications are associated with trocar insertion. The purpose of this study was to develop an objective method of evaluating the safety profile of various access devices used in laparoscopic surgery. STUDY DESIGN: In 20 swine, 6 bladed and 2 needle access devices were evaluated. A force profile was determined by measuring the force required to drive the trocar or needle through the fascia and into the peritoneum, at 0 and 10 mmHg. The amount Of tissue deformation, the length of blade exposed, and the duration of exposure were measured using a high-speed digital imaging system. RESULTS: The needle system without the sheath required the least driving force and had the most favorable force profile. In contrast, the bladed, nonretractable trocar system required a higher driving force and a rapid loss of resistance. Insertion under a pneumoperitoneum did not significantly alter the force profile of the various access devices except for the amount of tissue deformation. With the bladed system, the blade itself was exposed for an average of 0.5 to 1.0 seconds for a distance of 4.5 to 5.0 cm. In comparison, the needle system was exposed for 0.2 seconds for a distance of 1.8 cm. CONCLUSIONS: We developed a reproducible method of measuring the forces required to place the access systems, their pattern of resistance loss, and the characteristics of the blade exposure. These parameters may provide an adjunctive and objective measurement of safety, allowing for more direct comparison between various trocar designs. (J Am Coll Surg 2009;209:222-232. (C) 2009 by the American College of Surgeons)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Noninvasive positive-pressure ventilation (NPPV) modes are currently available on bilevel and ICU ventilators. However, little data comparing the performance of the NPPV modes on these ventilators are available. Methods: In an experimental bench study, the ability of nine ICU ventilators to function in the presence of leaks was compared with a bilevel ventilator using the IngMar ASL5000 lung simulator (IngMar Medical; Pittsburgh, PA) set at a compliance of 60 mL/cm H(2)O, an inspiratory resistance of 10 cm H(2)O/L/s, an expiratory resistance of 20 cm H(2)O/L/s, and a respiratory rate of 15 breaths/min. All of the ventilators were set at 12 cm H(2)O pressure support and 5 cm H(2)O positive end-expiratory pressure. The data were collected at baseline and at three customized leaks. Main results: At baseline, all of the ventilators were able to deliver adequate tidal volumes, to maintain airway pressure, and to synchronize with the simulator, without missed efforts or auto-triggering. As the leak was increased, all of the ventilators (except the Vision [Respironics; Murrysville, PA] and Servo I [Maquet; Solna, Sweden]) needed adjustment of sensitivity or cycling criteria to maintain adequate ventilation, and some transitioned to backup ventilation. Significant differences in triggering and cycling were observed between the Servo I and the Vision ventilators. Conclusions: The Vision and Servo I were the only ventilators that required no adjustments as they adapted to increasing leaks. There were differences in performance between these two ventilators, although the clinical significance of these differences is unclear. Clinicians should be aware that in the presence of leaks, most ICU ventilators require adjustments to maintain an adequate tidal volume. (CHEST 2009; 136:448-456)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

STUDY DESIGN: Controlled laboratory study. OBJECTIVE: To evaluate the effect of low-intensity therapeutic ultrasound on the murine calcaneus tendon healing process. BACKGROUND: Therapeutic ultrasound promotes formation and maturation of scar tissue. METHODS: Calcaneus tendon tenotomy and tenorrhaphy was performed on 28 Wistar rats. After the procedure, the animals were randomly divided into 2 groups. The animals in the experimental group received a 5-minute ultrasound application, once a day, at a frequency of 1 MHz, a spatial average temporal average intensity of 0.1 W/cm(2), and a spatial average intensity of 0.52 W/cm(2) at a 16-Hz frequency pulse mode (duty cycle, 20%). Data for the injured side were normalized in relation to the data from the contralateral healthy calcaneus tendon (relative values). The animals in the control group received sham treatment. After a 28-day treatment period, the animals were sacrificed and their tendons surgically removed and subjected to mechanical stress testing. The parameters analyzed were cross-sectional area (mm(2)), ultimate load (N), tensile strength (MPa), and energy absorption (mJ). RESULTS: A significant difference between groups was found for the relative values of ultimate load and tensile strength. The mean +/- SD ultimate load of the control group was -3.5% +/- 32.2% compared to 33.3% +/- 26.8% for the experimental group (P = .005). The mean tensile strength of the control group was -47.7% +/- 19.5% compared to -28.1% +/- 24.1% for the experimental group (P = .019). No significant difference was found in cross-sectional area and energy absorption. CONCLUSION: Low-intensity pulsed ultrasound produced by a conventional therapeutic ultrasound unit can positively influence the calcaneus tendon healing process in rats. J Ort hop Sports Phys Ther 2011;41(7):526-531, Epub 2 February 2011. doi:10.2519/jospt.2011.3468

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Solid pseudopapillary neoplasm of the pancreas is an uncommon but distinctive pancreatic neoplasm with low metastatic potential [1]. Therefore, whenever feasible, an organ-preserving operation should be performed. As previously reported, women with solid pseudopapillary neoplasm of the pancreas may be best treated by more conservative procedures [2]. Recently, laparoscopic pancreatic resections became more common and are being performed in highly specialized centers. There are only six cases of laparoscopic resection for solid pseudopapillary neoplasm of pancreas published in the English literature and, to our knowledge, laparoscopic resection of uncinate process of the pancreas has never been reported [3-6]. This video demonstrates the technical aspects of a totally laparoscopic resection of the uncinate process of the pancreas in a patient with solid pseudopapillary neoplasm. A 26-year-old woman with a 4-cm solid pseudopapillary pancreatic neoplasm was referred for surgical treatment. According to preoperative echoendoscopy, there was a safe margin between neoplasm and main pancreatic duct. The patient was placed in supine position with the surgeon standing between her legs. Four trocars, one 10-mm and three 5-mm, were used. At inspection, the inferior vena cava, transverse colon, duodenum, and pancreas are clearly identified. A Kocher maneuver was performed with complete exposure of pancreatic head and uncinate process. The uncinate process was dissected from the superior mesenteric vein and venous branches were divided between metallic clips or by use of laparoscopic coagulation shears (LCS; Ethicon Endo Surgery Industries, Cincinnati, OH, USA). Blood supply of the duodenum was preserved by ligature of small pancreatic branches from inferior pancreatoduodenal artery. Transection of pancreatic parenchyma was performed using laparoscopic coagulation shears, which is an effective tool for cutting the pancreas [7, 8]. Surgical specimen was removed through a suprapubic incision inside a retrieval bag. A hemostatic absorbable tissue (Surgicel; Ethicon Inc., Cincinnati, OH) was placed in the cutting pancreatic surface, and one round 19F Blake abdominal drain (Ethicon) was left in place. Operative time was 180 minutes and blood loss estimated in 40 ml with no blood transfusion. Hospital stay was 4 days. The patient did not have postoperative pancreatitis or pancreatic leakage, and the abdominal drain was removed on the tenth postoperative day. Final pathology confirmed the diagnosis of solid pseudopapillary neoplasm of pancreas with free surgical margins. The patient was well and asymptomatic 2 months after the procedure. Laparoscopic resection of uncinate process of the pancreas is safe and feasible and should be considered for patients suffering from pancreatic neoplasms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rationale: Upper airway muscle function plays a major role in maintenance of the upper airway patency and contributes to the genesis of obstructive sleep apnea syndrome (OSAS). Preliminary results suggested that oropharyngeal exercises derived from speech therapy may be an effective treatment option for patients with moderate OSAS. Objectives: To determine the impact of oropharyngeal exercises in patients with moderate OSAS. Methods: Thirty-one patients with moderate OSAS were randomized to 3 months of daily (similar to 30 min) sham therapy (n = 15, control) or a set of oropharyngeal exercises (n = 16), consisting of exercises involving the tongue, soft palate, and lateral pharyngeal wall. Measurements and Main Results: Anthropometric measurements, snoring frequency (range 0-4), intensity (1-3), Epworth daytime sleepiness (0-24) and Pittsburgh sleep quality (0-21) questionnaires, and full polysomnography were performed at baseline and at study conclusion. Body mass index and abdominal circumference of the entire group were 30.3 +/- 3.4 kg/m(2) and 101.4 +/- 9.0 cm, respectively, and did not change significantly over the study period. No significant change occurred in the control group in all variables. In contrast, patients randomized to oropharyngeal exercises had a significant decrease (P < 0.05) in neck circumference (39.6 +/- 3.6 vs. 38.5 +/- 4.0 cm), snoring frequency (4 [4-4] vs. 3 [1.5-3.5]), snoring intensity (3 [3-4] vs. 1 [1-2]), daytime sleepiness (14 +/- 5 vs. 8 +/- 6), sleep quality score (10.2 +/- 3.7vs. 6.9 +/- 2.5), and OSAS severity (apnea-hypopnea index, 22.4 +/- 4.8 vs. 13.7 +/- 8.5 events/h). Changes in neck circumference correlated inversely with changes in apnea-hypopnea index (r = 0.59; P < 0.001). Conclusions: Oropharyngeal exercises significantly reduce OSAS severity and symptoms and represent a promising treatment for moderate OSAS. Clinical trial registered with www.clinicaltrials.gov (NCT 00660777).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Enucleation of small lesions located near the hepatic surface can be achieved with low morbidity and mortality. This article describes a simple laparoscopic technique for enucleation of liver tumors. Methods: After inspection and intraoperative ultrasonography, Glisson`s capsule is marked with eletrocautery 2 cm away from the tumor margin. Ultrasonography is used to ascertain surgical margin right before liver transection. Hemihepatic ischemia is applied and marked area is anchored by stitches. The suture is held together by metallic clips and upward traction is performed, facilitating the transection of the parenchyma and correct identification of vascular and biliary structures. Results: This technique has been successfully employed in six consecutive patients. There were four men and two women, mean age 50.3 years. Four patients underwent liver resection for malignant disease and two for benign liver neoplasm. Pathologic surgical margins were free in all cases and mean hospital stay was 2 days. No postoperative mortality was observed. Conclusion: This technique may facilitate laparoscopic nonanatomical liver resection and reduce risk of positive surgical margins. It is also useful in combination with anatomical laparoscopic liver resections such as right or left hemihepatectomies in patients with bilateral liver tumors as occurred in one of our patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: A giant fusiform aneurysm in the posterior cerebral artery (PCA) is rare, as is fenestration of the PCA and basilar apex variation. We describe the angiographic and surgical findings of a giant fusiform aneurysm in the P1-P2 PCA segment associated with PCA bilateral fenestration and superior cerebellar artery double origin. CLINICAL PRESENTATION: A 26-year-old woman presented with a 2-month history of visual blurring. Digital subtraction angiography showed a giant (2.5 cm) fusiform PCA aneurysm in the right P1-P2 segment. The 3-dimensional view showed a caudal fusion pattern from the upper portion of the basilar artery associated with a bilateral long fenestration of the P1 and P2 segments and superior cerebellar artery double origin. INTERVENTION: Surgical trapping of the right P1 -P2 segment, including the posterior communicating artery, was performed by a pretemporal approach. Angiograms performed 3 and 13 months after surgery showed complete aneurysm exclusion, and the PCA was permeated and filled the PCA territory. Clinical follow-up at 14 months showed the patient with no deficits and a return to normal life. CONCLUSION: To our knowledge, this is the first report of a giant fusiform aneurysm of the PCA associated with P1-P2 segment fenestration and other variations of the basilar apex (bilateral superior cerebellar artery duplication and caudal fusion). Comprehension of the embryology and anatomy of the PCA and its related vessels and branches is fundamental to the decision-making process for a PCA aneurysm, especially when parent vessel occlusion is planned.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To describe the use of self-expandable metallic stents to manage malignant colorectal obstructions and to compare the radiation dose between fluoroscopic guidance of stent placement and combined endoscopic and fluoroscopic guidance. Materials and Methods: From January 1998 to December 2007, 467 oncology patients undergoing colorectal stent placement in a single center were included in the study. Informed consent was obtained in all cases. All procedures were performed with fluoroscopic or combined fluoroscopic and endoscopic guidance. Inclusion criteria were total or partial colorectal obstruction of neoplastic origin. Exclusion criteria were life expectancy shorter than I month, suspicion of perforation, and/or severe colonic neoplastic bleeding. Procedure time and radiation dose were recorded, and technical and clinical success were evaluated. Follow-up was performed by clinical examination and simple abdominal radiographs at 1 day and at I, 3, 6, and 12 months. Results: Of 467 procedures, technical success was achieved in 432 (92.5%). Thirty-five treatments (7.5%) were technical failures, and the patients were advised to undergo surgery. Significant differences in radiation dose and clinical success were found between the fluoroscopy and combined-technique groups (P < .001). Total decompression was achieved in 372 cases, 29 patients showed remarkable improvement, 11 showed slight improvement, and 20 showed clinical failure. Complications were recorded in 89 patients (19%), the most significant were perforation (2.3%) and stent migration (6.9%). Mean interventional time and radiation dose were 67 minutes and 3,378 dGy.cm(2), respectively. Conclusions: Treatment of colonic obstruction with stents requires a long time in the interventional room and considerable radiation dose. Nevertheless, the clinical benefits and improvement in quality of life justify the radiation risk.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Obstructive sleep apnea (OSA) is common among patients on maintenance hemodialysis. However, the factors associated with the origin of OSA as well as the cardiovascular consequences in this population are not completely understood. We evaluated, by standard overnight polysomnography, 24-hour ambulatory blood pressure (BP) monitoring and echocardiography in 30 patients (14 males, age 34 +/- 11 years, BMI 23.2 +/- 5.2) - 15 on short daily hemodialysis (SDH) and 15 matched patients on conventional hemodialysis (CHD). The hemodialysis dose (standard Kt/V) was higher in patients on SDH than on CHD (p = 0.001). OSA (apnea-hypopnea index 1 5 events/h) was present in 13 patients (43%). Patients with OSA were predominantly males (77 vs. 44%), presented a higher BMI (25.5 +/- 6.2 vs. 21.5 +/- 3.6), a larger neck circumference (38 +/- 1 vs. 34 +/- 1 cm) and a lower Kt/V (2.6 +/- 0.3 vs. 2.2 +/- 0.1) than patients with no OSA (p < 0.05). Neck circumference and lower Kt/V were independently associated with OSA on multivariate analysis. No patient with Kt/V > 2.5 (n = 10) presented OSA. On the other hand, hypertensive patients with OSA needed more BP control pills (p = 0.03). Despite similar BP control, patients with OSA presented a higher interventricular septum thickness (11.5 +/- 0.5 vs. 9.9 +/- 0.3 mm; p = 0.011). In conclusion, among patients on maintenance hemodialysis, the traditional risk factors for OSA are present and interact with hemodialysis efficiency. Among these patients, OSA is associated with difficult BP control and heart remodeling suggesting that OSA may contribute to poor cardiovascular outcome. Copyright (c) 2008 S. Karger AG, Basel

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the frequency of overweight and obesity in health professionals, before and after a single specialized dietary recommendation. Methods: Anthropometric measures of 579 workers of a general hospital in the city of Sao Paulo, Brazil were taken. The weight (f), height (h) and waist circumference (wc) were interpreted according to the WHO and NCEP ATP III guidelines. Nutrition specialist provided dietary and behavioral recommendations. The entire sample underwent a new evaluation one year later. Results: At the first evaluation, 79 employees presente WC >= 102 cm (male) or WC >= 88 cm (female). The association between WC >= 102 cm (men) or WC >= 88 cm (women) and BMI >= 30 kg/m(2) was found in 12.8 % (69 subjects). The BMI distribution per age group indicated that the increase in overweight and obesity was directly proportional to the age increase. Physical activities were not practiced by 75% of the subjects studied. A year later, the evaluation indicated lack of statistical differences regarding the BMI and waist circumference of the sample and only 2.8% started to practice a physical activity. Conclusion: Dietary recommendation alone failed to promote changes in the eating habits of health professionals who work at a general hospital or to encourage them to practice exercise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Context: Several factors can affect adult height (AH) of patients with gonadotropin-dependent precocious puberty (GDPP) treated with depot GnRH analogs. Objective: Our objective was to determine factors influencing AH in patients with GDPP treated with depot GnRH analogs. Patients: A total of 54 patients (45 girls) with GDPP treated with depot GnRH analog who reached AH was included in the study. Design: Univariate and multivariate analyses of the factors potentially associated with AH were performed in all girls with GDPP. In addition, clinical features of the girls who attained target height (TH) range were compared with those who did not. Predicted height using Bayley and Pinneau tables was compared with attained AH. Results: In girls the mean AH was 155.3 +/- 6.9 cm (-1.2 +/- 1 SD) with TH range achieved by 81% of this group. Multiple regression analysis revealed that the interval between chronological age at onset of puberty and at the start of GnRH analog therapy, height SD scores (SDSs) at the start and end of therapy, and TH explained 74% of AH variance. The predicted height at interruption of GnRH therapy, obtained from Bayley and Pinneau tables for average bone age, was more accurate than for advanced bone age in both sexes. In boys the mean AH was 170.6 +/- 9.2 cm (-1 +/- 1.3 SDS), whereas TH was achieved by 89% of this group. Conclusions: The major factors determining normal AH in girls with GDPP treated with depot GnRH analogs were shorter interval between the onset of puberty and start of therapy, higher height SDS at the start and end of therapy, and TH. Therefore, prompt depot GnRH analog therapy in properly selected patients with GDPP is critical to obtain normal AH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Data were retrospectively collected from 69 Brazilian patients (45 boys) with growth hormone deficiency (GHD) who received exogenous growth hormone (GH) for a median duration of 4 years (range 1-13 years). Forty-two patients had multiple pituitary hormone deficiencies and 27 had isolated GHD. Peak GH was <7 ng/ml (IRMA) or <3.2 ng/ml (IFMA) after two stimulation tests.. Therapy was started at median age of 10.0 years (range 2.2-21.6 years), bone age of 5.8 years (0.5-13.5 years) and height standard deviation score -4.4 (range -9.3 to -1.6). MRI revealed pituitary abnormalities in 87% of patients. Homozygous mutations in PROP-1, GHRH-R, GH-1 or HESX-1 genes were found in 12 patients. Mean height velocities were 3.3 pretreatment and 10.3, 7.8, 7.4 and 6.4 cm/yr, respectively, during 1-4 years of treatment with GH. In conclusion, the high prevalence (96%) of genetic and/or pituitary abnormalities probably reflects the stringent diagnostic criteria used, and GH replacement resulted in significant catch-up growth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Context.-Studies analyzing the concordance of biopsy and radical prostatectomy (RP) Gleason scores have limitations. Some included 2 or more centers, used historical controls from the early prostate specific antigen era or lacked a clear definition of the biopsy schemes. Furthermore, most did not control the results for prostate volume. Objective.-To confirm whether prediction of RP Gleason score can be optimized by taking more biopsy cores in a contemporary series of patients, with pathologic samples analyzed by the same pathologist, and controlling these results for prostate volume. Design.-The study comprised a retrospective case-control analysis of 393 patients with prostate cancer treated with RP. Patients were divided into 3 groups: those in group 1 underwent a 6-core biopsy; group 2, an 8-core biopsy; and group 3, a 10 or more-core biopsy. Concordance rates between biopsy and RP Gleason scores, as well as the rates of undergrading and overgrading, were determined for each biopsy scheme. Results.-Concordance rates were 60.9%, 58.3%, and 64.6% for patients from groups 1, 2, and 3, respectively (P = .18). When we analyzed patients with prostate volumes of less than 50 cm(3), concordance rates were 58.3%, 58.3%, and 65.1% for each group, respectively (P = .03). Among patients with prostate volumes of 50 cm3 or more, concordance rates were 70%, 58.1%, and 63.6%, respectively (P = .66). Conclusions.-Taking 10 or more cores can improve the prediction of RP Gleason score in patients with prostate volumes of less than 50 cm3. For patients with prostate volumes of 50 cm3 or more, increasing the biopsy cores to 10 or more did not improve prediction of RP Gleason score.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To build nomograms of fetal thyroid circumference (FTC), fetal thyroid area (FTA), and fetal thyroid transverse diameter (FTTD) throughout gestational age (GA). Method. Between January 2006 and July 2006, FTC, FTA, and FTTD were measured once in 196 normal fetuses examined at a GA of 22-35 weeks. Inclusion criteria were a healthy mother with normal maternal thyrotropin level during pregnancy, a singleton pregnancy with normal fetal morphology on sonography, and GA confirmed via first-trimester sonographic examination. Results. Mean FTC, FTA, and FTTD ranged from 3.21 cm, 0.58 cm(2), and 1.19 cm at 22 weeks to 5.11 cm, 1.69 cm(2), and 1.89 cm at 35 weeks, respectively. Linear regression analysis yielded the following formulas for FTC, FTA, and FTTD according to GA: FTC (cm) = 0.146 X GA (weeks); FTA (cm(2)) = -1.289 + 0.085 X GA (weeks); FTTD (cm) = 0.054 X GA (weeks). The following logarithmic formulas were obtained for the expected fetal thyroid measurements according to estimated fetal weight (FW): FTC (cm) = -4.791 + 1.265 X logN FW; FTA (cm(2)) = -1.676 + 0.455 X logN FW; and FTTD (cm) = 0.399 + 0.001 X logN FW. Conclusion. We describe new nomograms of fetal thyroid measurements throughout gestation that may be useful in case of thyroid dysfunction. (C) 2008 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: A 150 cm(3) pear-shaped gastric balloon with a 30 cm-long duodenal stem and a 7 g metallic weight at its distal end was designed and developed to facilitate weight loss by (a) delaying gastric emptying thus enhancing interprandial satiety, and (b) stimulating antral and duodenal receptors of satiation. Methods: Twenty-six patients (body mass index of 29 to 40 kg/m(2)) who failed to lose weight despite dietary intervention underwent endoscopic implantation of the balloon device. Patients were monitored for tolerance to the balloon, complications, weight loss, and compliance with a restricted caloric intake. Results: Six men and 20 women with a median body weight of 93.0kg (range, 73.5 to 119.9), median body mass index 34.3 kg/m(2) (range, 28.8 to 39.5) underwent balloon implantation for a median period of 4.0 months (range, 0.75 to 6.0). Twenty-two patients successfully complied with a 1250 to 1500 kcal daily diet restriction during the study period. Median weight reduction was 6.5 kg (range, 3.7 to 19.9). Patients with initial body weight of > 90 kg tended to loose more weight (8.1 kg) than patients weighing < 90 kg (4.5 kg) (P = 0.14). Nine patients with dwell times of 6 months lost 11.5 +/- 4.6 kg. The balloon malfunctioned in 4 patients (in I patient, the balloon leaked spontaneously but remained in the stomach and in 3 patients, the balloon migrated distally). Conclusions: Our novel balloon device may be effective in inducing weight loss by promoting compliance with a restricted caloric intake and is well tolerated due to its small size. Complications resulted from balloon rupture, which can be easily prevented by enhancements in design and use of alternative materials.