930 resultados para Benefit cost ratio
Resumo:
The high penetration of distributed energy resources (DER) in distribution networks and the competitiveenvironment of electricity markets impose the use of new approaches in several domains. The networkcost allocation, traditionally used in transmission networks, should be adapted and used in the distribu-tion networks considering the specifications of the connected resources. The main goal is to develop afairer methodology trying to distribute the distribution network use costs to all players which are usingthe network in each period. In this paper, a model considering different type of costs (fixed, losses, andcongestion costs) is proposed comprising the use of a large set of DER, namely distributed generation(DG), demand response (DR) of direct load control type, energy storage systems (ESS), and electric vehi-cles with capability of discharging energy to the network, which is known as vehicle-to-grid (V2G). Theproposed model includes three distinct phases of operation. The first phase of the model consists in aneconomic dispatch based on an AC optimal power flow (AC-OPF); in the second phase Kirschen’s andBialek’s tracing algorithms are used and compared to evaluate the impact of each resource in the net-work. Finally, the MW-mile method is used in the third phase of the proposed model. A distributionnetwork of 33 buses with large penetration of DER is used to illustrate the application of the proposedmodel.
Resumo:
Dissertation presented at Faculty of Sciences and Technology of the New University of Lisbon to attain the Master degree in Electrical and Computer Science Engineering
Resumo:
O instável mas tendencialmente crescente preço dos combustíveis associado a preocupações ambientais cada vez mais enraizadas nas sociedades, têm vindo a despoletar uma maior atenção à procura de combustíveis alternativos. Por outro lado, várias projecções indicam um aumento muito acentuado do consumo energético global no curto prazo, fruto do aumento da população e do nível de industrialização das sociedades. Neste contexto, o biodiesel (ésteres de ácidos gordos) obtido através da transesterificação de triglicerídeos de origem vegetal ou animal, surge como a alternativa “verde” mais viável para utilização em equipamentos de combustão. A reacção de transesterificação é catalisada, por norma com recurso a catalisadores homogéneos alcalinos (NaOH ou KOH). Este tipo de processo, o único actualmente com expressão a nível industrial, apresenta algumas desvantagens que, para além de aumentarem o custo do produto final, contribuem para reduzir a benignidade do mesmo: a impossibilidade de reutilização do catalisador, o aumento do número e complexidade das etapas de separação e a produção de efluentes resultantes das referidas etapas. Com o intuito de minimizar ou eliminar estes problemas, vários catalisadores heterogéneos têm vindo a ser estudados para esta reacção. Apesar de muitos apresentarem resultados promissores, a grande maioria não tem viabilidade para aplicação industrial seja devido ao seu próprio custo, seja devido aos pré-tratamentos necessários à sua utilização. Entre estes catalisadores, o óxido de cálcio é talvez o que apresenta resultados mais promissores. O crescente número de estudos envolvendo este catalisador em detrimento de outros, é por si mesmo prova do potencial do CaO. A realização deste trabalho pretendia atingir os seguintes objectivos principais: • Avaliar a elegibilidade do óxido de cálcio enquanto catalisador da reacção de transesterificação de óleos alimentares usados com metanol; • Avaliar qual a sua influência nas características dos produtos finais; • Avaliar as diferenças de performance entre o óxido de cálcio activado em atmosfera inerte (N2) e em ar, enquanto catalisadores da reacção de transesterificação de óleos alimentares usados com metanol; • Optimizar as condições da reacção com recurso às ferramentas matemáticas disponibilizadas pelo planeamento factorial, através da variação de quatro factores chave de influência: temperatura, tempo, relação metanol / óleo e massa de catalisador utilizado. O CaO utlizado foi obtido a partir de carbonato de cálcio calcinado numa mufla a 750 °C durante 3 h. Foi posteriormente activado a 900 °C durante 2h, em atmosferas diferentes: azoto (CaO-N2) e ar (CaO-Ar). Avaliaram-se algumas propriedades dos catalisadores assim preparados, força básica, concentração de centros activos e áreas específicas, tendo-se obtido uma força básica situada entre 12 e 14 para ambos os catalisadores, uma concentração de centros activos de 0,0698 mmol/g e 0,0629 mmol/g e áreas específicas de 10 m2/g e 11 m2/g respectivamente para o CaO-N2 e CaO-Ar. Efectuou-se a transesterificação, com catálise homogénea, da mistura de óleos usados utilizada neste trabalho com o objectivo de determinar os limites para o teor de FAME’s (abreviatura do Inglês de Fatty Acid Methyl Esters’) que se poderiam obter. Foi este o parâmetro avaliado em cada uma das amostras obtidas por catálise heterogénea. Os planos factoriais realizados tiveram como objectivo maximizar a sua quantidade recorrendo à relação ideal entre tempo de reacção, temperatura, massa de catalisador e quantidade de metanol. Verificou-se que o valor máximo de FAME’s obtidos a partir deste óleo estava situado ligeiramente acima dos 95 % (m/m). Realizaram-se três planos factoriais com cada um dos catalisadores de CaO até à obtenção das condições óptimas para a reacção. Não se verificou influência significativa da relação entre a quantidade de metanol e a massa de óleo na gama de valores estudada, pelo que se fixou o valor deste factor em 35 ml de metanol / 85g de óleo (relação molar aproximada de 8:1). Verificou-se a elegibilidade do CaO enquanto catalisador para a reacção estudada, não se tendo observado diferenças significativas entre a performance do CaO-N2 e do CaO-Ar. Identificaram-se as condições óptimas para a reacção como sendo os valores de 59 °C para a temperatura, 3h para o tempo e 1,4 % de massa de catalisador relativamente à massa de óleo. Nas referidas condições, obtiveram-se produtos com um teor de FAME’s de 95,7 % na catálise com CaO-N2 e 95,3 % na catálise com CaO-Ar. Alguns autores de estudos consultados no desenvolvimento do presente trabalho, referiam como principal problema da utilização do CaO, a lixiviação de cálcio para os produtos obtidos. Este facto foi confirmado no presente trabalho e na tentativa de o contornar, tentou-se promover a carbonatação do cálcio com a passagem de ar comprimido através dos produtos e subsequente filtração. Após a realização deste tratamento, não mais se observaram alterações nas suas propriedades (aparecimento de turvação ou precipitados), no entanto, nos produtos obtidos nas condições óptimas, a concentração de cálcio determinada foi de 527 mg/kg no produto da reacção catalisada com CaO-N2 e 475 mg/kg com CaO-A. O óxido de cálcio apresentou-se como um excelente catalisador na transesterificação da mistura de óleos alimentares usados utilizada no presente trabalho, apresentando uma performance ao nível da obtida por catálise homogénea básica. Não se observaram diferenças significativas de performance entre o CaO-N2 e o CaO-Ar, sendo possível obter nas mesmas condições reaccionais produtos com teores de FAME’s superiores a 95 % utilizando qualquer um deles como catalisador. O elevado teor de cálcio lixiviado observado nos produtos, apresenta-se como o principal obstáculo à aplicação a nível industrial do óxido de cálcio como catalisador para a transesterificação de óleos.
Resumo:
The aseptic meningitis after Measles-Mumps-Rubella vaccine (MMR) is a well recognized complication, and different incidences have been observed in several studies. We retrospectively analyzed forty cases of aseptic meningitis, during a large public immunization campaign (1998) in Curitiba, Southern Brazil (590,609 people), admitted in our Service. The vaccine utilized was Leningrad-3-Zagreb mumps strain, Edmonston-Zagreb measles strain, and RA 27#3 rubella strain. In all county, a total number of 87 cases were reported, resulting in a incidence of 1.7 cases per 10,000 given doses . The mean age was 23.7 ± 12.8 years. The female:male ratio was 1.35:1. Severe headache with meningismus (92.5%), fever (87.5%), nausea/vomiting (82.5%) were the most common clinical findings. Three cases (7.5%) developed mild mumps. All patients underwent cerebrospinal fluid (CSF) tap with the following findings: mononuclear pleocytosis from 100 to 500 cells/mm³ in 17 cases (42.5%; 257.5 ± 260.6 cells/mm³); increased protein 28 cases (67.5%; 92.1 ± 76.9 mg/dL); glucose was normal in all cases (56.8 ± 11.2 mg/dL) except in 4 (10%) cases, which presented less than 44 mg/dL. All serological tests (latex to bacterial meningitis, Cryptococcus, cysticercosis, VDRL) and bacteriological cultures were negative. Virus identification were also negative in 8 samples. None of the patients had neurological deficits or related symptoms after one year of onset. We believe the benefit of vaccination clearly outweights the incidence of benign vaccine-associated meningitis.
Resumo:
Coarse Grained Reconfigurable Architectures (CGRAs) are emerging as enabling platforms to meet the high performance demanded by modern applications (e.g. 4G, CDMA, etc.). Recently proposed CGRAs offer time-multiplexing and dynamic applications parallelism to enhance device utilization and reduce energy consumption at the cost of additional memory (up to 50% area of the overall platform). To reduce the memory overheads, novel CGRAs employ either statistical compression, intermediate compact representation, or multicasting. Each compaction technique has different properties (i.e. compression ratio, decompression time and decompression energy) and is best suited for a particular class of applications. However, existing research only deals with these methods separately. Moreover, they only analyze the compaction ratio and do not evaluate the associated energy overheads. To tackle these issues, we propose a polymorphic compression architecture that interleaves these techniques in a unique platform. The proposed architecture allows each application to take advantage of a separate compression/decompression hierarchy (consisting of various types and implementations of hardware/software decoders) tailored to its needs. Simulation results, using different applications (FFT, Matrix multiplication, and WLAN), reveal that the choice of compression hierarchy has a significant impact on compression ratio (up to 52%), decompression energy (up to 4 orders of magnitude), and configuration time (from 33 n to 1.5 s) for the tested applications. Synthesis results reveal that introducing adaptivity incurs negligible additional overheads (1%) compared to the overall platform area.
Resumo:
6th Graduate Student Symposium on Molecular Imprinting
Resumo:
Currently, due to the widespread use of computers and the internet, students are trading libraries for the World Wide Web and laboratories with simulation programs. In most courses, simulators are made available to students and can be used to proof theoretical results or to test a developing hardware/product. Although this is an interesting solution: low cost, easy and fast way to perform some courses work, it has indeed major disadvantages. As everything is currently being done with/in a computer, the students are loosing the “feel” of the real values of the magnitudes. For instance in engineering studies, and mainly in the first years, students need to learn electronics, algorithmic, mathematics and physics. All of these areas can use numerical analysis software, simulation software or spreadsheets and in the majority of the cases data used is either simulated or random numbers, but real data could be used instead. For example, if a course uses numerical analysis software and needs a dataset, the students can learn to manipulate arrays. Also, when using the spreadsheets to build graphics, instead of using a random table, students could use a real dataset based, for instance, in the room temperature and its variation across the day. In this work we present a framework which uses a simple interface allowing it to be used by different courses where the computers are the teaching/learning process in order to give a more realistic feeling to students by using real data. A framework is proposed based on a set of low cost sensors for different physical magnitudes, e.g. temperature, light, wind speed, which are connected to a central server, that the students have access with an Ethernet protocol or are connected directly to the student computer/laptop. These sensors use the communication ports available such as: serial ports, parallel ports, Ethernet or Universal Serial Bus (USB). Since a central server is used, the students are encouraged to use sensor values results in their different courses and consequently in different types of software such as: numerical analysis tools, spreadsheets or simply inside any programming language when a dataset is needed. In order to do this, small pieces of hardware were developed containing at least one sensor using different types of computer communication. As long as the sensors are attached in a server connected to the internet, these tools can also be shared between different schools. This allows sensors that aren't available in a determined school to be used by getting the values from other places that are sharing them. Another remark is that students in the more advanced years and (theoretically) more know how, can use the courses that have some affinities with electronic development to build new sensor pieces and expand the framework further. The final solution provided is very interesting, low cost, simple to develop, allowing flexibility of resources by using the same materials in several courses bringing real world data into the students computer works.
Resumo:
The pathogenesis of the renal lesion upon envenomation by snakebite has been related to myolysis, hemolysis, hypotension and/or direct venom nephrotoxicity caused by the venom. Both primary and continuous cell culture systems provide an in vitro alternative for quantitative evaluation of the toxicity of snake venoms. Crude Crotalus vegrandis venom was fractionated by molecular exclusion chromatography. The toxicity of C. vegrandis crude venom, hemorrhagic, and neurotoxic fractions were evaluated on mouse primary renal cells and a continuous cell line of Vero cells maintained in vitro. Cells were isolated from murine renal cortex and were grown in 96 well plates with Dulbecco's Modified Essential Medium (DMEM) and challenged with crude and venom fractions. The murine renal cortex cells exhibited epithelial morphology and the majority showed smooth muscle actin determined by immune-staining. The cytotoxicity was evaluated by the tetrazolium colorimetric method. Cell viability was less for crude venom, followed by the hemorrhagic and neurotoxic fractions with a CT50 of 4.93, 18.41 and 50.22 µg/mL, respectively. The Vero cell cultures seemed to be more sensitive with a CT50 of 2.9 and 1.4 µg/mL for crude venom and the hemorrhagic peak, respectively. The results of this study show the potential of using cell culture system to evaluate venom toxicity.
Resumo:
This work presents a low cost RTK-GPS system for localization of unmanned surface vehicles. The system is based on the use of standard low cost L1 band receivers and in the RTKlib open source software library. Mission scenarios with multiple robotic vehicles are addressed as the ones envisioned in the ICARUS search and rescue case where the possibility of having a moving RTK base on a large USV and multiple smaller vehicles acting as rovers in a local communication network allows for local relative localization with high quality. The approach is validated in operational conditions with results presented for moving base scenario. The system was implemented in the SWIFT USV with the ROAZ autonomous surface vehicle acting as a moving base. This setup allows for the performing of a missions in a wider range of environments and applications such as precise 3D environment modeling in contained areas and multiple robot operations.
Resumo:
O presente trabalho pretende mostrar que a aplicação de medidas de conservação de energia (MCE) pode representar uma redução da intensidade de utilização de matérias-primas na construção de um edifício. Mais concretamente, pode representar uma redução da utilização de materiais e equipamentos, e como consequência, uma redução no esforço económico ao primeiro investimento. Podendo posteriormente representar uma redução na utilização de energia durante o período de funcionamento do edifício. A aplicação de MCE no sector da construção tem vindo a ser uma prática corrente nos novos edifícios e edifícios sujeitos a grandes intervenções de reabilitação. Esta prática deve-se à obrigatoriedade de cumprimento de requisitos regulamentares aplicados à otimização do desempenho energético dos edifícios e dos seus sistemas técnicos, nomeadamente, o RCCTE e o RSECE, entretanto revogados pelo REH e pelo RECS, respetivamente. A implementação de MCE apresenta, na maioria dos casos, benefícios económicos para o promotor do edifício, uma vez que se traduz muitas vezes, na otimização do dimensionamento dos sistemas de Aquecimento, Ventilação e Ar Condicionado (AVAC). Esta otimização permite reduzir os custos associados ao primeiro investimento, bem como na utilização de energia por parte do utilizador, logo na redução dos custos de exploração. No entanto, a falta de quantificação dos impactos do dimensionamento dos sistemas AVAC, da redução de utilização de energia e da análise do custo-benefício da sua aplicação pode condicionar o interesse na sua implementação. Neste contexto, surge a presente dissertação, por iniciativa do Instituto Soldadura e Qualidade (ISQ), aplicado a um caso prático de um edifício já construído e propriedade daquela empresa. Com este trabalho pretende-se avaliar o contributo efetivo das MCE implementadas na fase de projeto e na fase de construção, quer na otimização da dimensão de sistemas e equipamentos AVAC, por via da redução das necessidades energéticas, quer na redução de utilização de energia, permitindo, de seguida, uma avaliação custo-benefício.Na base do caso de estudo está o ECOTERMOLAB, o edifício acima referido, adquirido pelo ISQ para instalação de um laboratório de formação, investigação e desenvolvimento na área da energia. Após aquisição pelo ISQ, o edifício sofreu várias alterações/beneficiações, entre as quais a implementação de MCE, tais como, a aplicação de isolamento térmico na envolvente opaca (paredes, pavimentos e coberturas), duplicação dos vãos envidraçados simples, conferindo-lhes melhores caraterísticas térmicas, e pela aplicação de proteções solar. Foram ainda adotadas MCE aos sistemas AVAC, designadamente, pela adoção de recuperadores de calor nas Unidades de Tratamento de Ar Novo (UTAN’s) e de variadores de velocidade nas bombas de circulação de água e nos ventiladores de ar das UTAN’s. Pretendia o ISQ concluir se a aplicação de todas as MCE contribuiu de forma efetiva para o dimensionamento de sistemas e equipamentos AVAC de menor capacidade e, consequentemente, numa redução de utilização de energia. Em sequência, pretendia avaliar a viabilidade económica da aplicação de todas as MCE, estimando o sobrecusto inicial e o tempo necessário para o retorno financeiro daquele investimento. Para alcançar os objetivos propostos, procedeu-se à simulação energética dinâmica do ECOTERMOLAB, utilizando o programa EnergyPlus. Primeiro foi simulada uma situação base do edifício, sem quaisquer MCE. Posteriormente foi caraterizada cada uma das situações de aplicação das MCE, com o objetivo de avaliar o respetivo impacto individual na utilização de energia pelos sistemas AVAC. Por último foram assumidas todas as soluções em conjunto para avaliar o impacto final de todas as MCE na utilização de energia dos sistemas AVAC, bem como no seu dimensionamento. Das simulações dinâmicas foram obtidos os valores das necessidades de aquecimento e arrefecimento, de energia utilizada pelos sistemas AVAC e de caudais de água aquecida e arrefecida circulada. Com estes valores foi feita uma estimativa de dimensionamento dos equipamentos e componentes AVAC para as situações da aplicação de todas as MCE no ECOTERMOLAB e a sua ausência. A partir da diferença dos custos de aquisição dos respetivos equipamentos e dos valores de poupança em energia foi realizado o estudo da viabilidade económica da implementação das MCE neste edifício. Este estudo permitiu concluir que a aplicação das MCE no ECOTERMOLAB levou à redução da dimensão na generalidade dos equipamentos e componentes AVAC. Permitiu, ainda, concluir que houve uma diminuição de utilização de energia por parte destes sistemas e equipamentos para o aquecimento e arrefecimento. Conclui-se ainda que o período de retorno (Payback) do sobrecusto inicial, estimado em 37.822€ é de, aproximadamente, onze anos e meio, para um valor atual líquido (VAL) de 8.061€ e à taxa interna de rentabilidade (TIR) de 7,03%.
Resumo:
O elevado consumo de água associado à escassez deste recurso contribuiu para que alternativas de reutilização/reciclagem de água fossem estudadas que permitam diminuir o seu consumo e minimizar a dependência das indústrias. Monitorizar e avaliar os consumos de água, a nível industrial, é imprescindível para assegurar uma gestão sustentável dos recursos hídricos, sendo este o objetivo da presente dissertação. As alternativas encontradas na unidade industrial em estudo foram a substituição do equipamento sanitário e o aproveitamento do efluente tratado para operações de lavagem e/ou arrefecimento por contacto direto. A maioria do equipamento sanitário não é eficiente, tendo-se proposto a substituição desse sistema por um de menor consumo que permitirá uma poupança de 30 % no consumo de água, que corresponderá a 12 149,37 €/ano, sendo o retorno do investimento estimado em 3 meses. O efluente industrial na entrada da ETAR e nas diferentes etapas - tratamento primário de coagulação/floculação; tratamento secundário ou biológico em SBR; tratamento terciário de coagulação/floculação - foi caracterizado através da medição da temperatura, pH, oxigénio dissolvido e pela determinação da cor, turvação, sólidos suspensos totais (SST), azoto total, carência química de oxigénio (CQO), Carência Bioquímica de Oxigénio ao fim de 5 dias (CBO5) e razão CBO5/CQO. Esta caracterização permitiu avaliar o efluente industrial bruto que se caracteriza por um pH alcalino (8,3 ± 1,7); condutividade baixa (451 ± 200,2 μS/cm); elevada turvação (11 255 ± 8812,8 FTU); cor aparente (63 670 ± 42293,4 PtCo) e cor verdadeira (33 621 ± 19547,9 PtCo) elevadas; teores elevados de CQO (24 753 ± 11806,7 mg/L O2) SST (5 164 ± 3845,5 mg/L) e azoto total (718 mg/L) e um índice de biodegradabilidade baixo (razão CBO5/CQO de 1,4). Este estudo permitiu verificar que a eficiência global do tratamento do efluente foi 82 % na remoção da turvação, 83 % na remoção da cor aparente, 96 % na remoção da cor verdadeira, 85 % na remoção da CQO e 30 % na remoção dos SST. Quanto às eficiências de remoção associadas ao tratamento primário no que diz respeito à turvação, cor aparente, CQO e SST, apresentam valores inferiores aos referidos na literatura para o mesmo tipo de tratamento em efluentes similares. As eficiências de remoção obtidas no tratamento secundário são inferiores às do tratamento primário: turvação, cor aparente, CQO e SST, pelo que procurou-se otimizar a primeira etapa do processo de tratamento Neste estudo de otimização estudou-se a influência de cinco coagulantes – Sulfato de Alumínio, PAX XL – 10, PAX 18, cloreto de ferro e a conjugação de PAX 18 com sulfato de ferro - e seis floculantes – Superfloc A 150, Superfloc A 130, PA 1020, Ambifloc 560, Ambifloc C58 e Rifloc 54 - no tratamento físico-químico do efluente. O PAX 18 e o Ambifloc 560 UUJ foram os que apresentaram as mais elevadas eficiências de remoção (99,85 % na cor, 99,87 % na turvação, 90,12 % na CQO e 99,87 % nos SST). O custo associado a este tratamento é de 1,03 €/m3. Pela comparação com os critérios de qualidade no guia técnico ERSAR, apenas o parâmetro da CQO excede o valor, contudo o valor obtido permite diminuir os custos associados a um tratamento posterior para remoção da CQO remanescente no efluente residual tratado.
Resumo:
Nos últimos anos assistiu-se ao crescente aumento do custo da Energia Elétrica (EE), com grande impacto após o ano 2012 devido à alteração no escalão da taxa de IVA aplicável. Por outro lado tem-se ainda vindo a verificar o aumento do défice tarifário devido a um conjunto de medidas e decisões estratégicas que atualmente estão a ser pagas por todos os consumidores de energia. A introdução dos programas da microprodução seguida da miniprodução, por parte da Direção Geral de Energia e Geologia (DGEG), permitiu aos pequenos e grandes consumidores de EE, efetuar localmente produção de EE por intermedio de fontes renováveis. Contudo, segundo as “limitações” por parte destes programas, apenas era permitido aos novos pequenos produtores injetar toda a eletricidade produzida na rede elétrica, não proporcionando qualquer benefício ao nível do consumo de energia local. Ano após ano, tem-se verificado uma revisão negativa, por parte da DGEG, sobre as tarifas de remuneração da energia produzida por estes sistemas, o que abalou significativamente um setor que até aqui tinha vindo a crescer a passos largos. Tendo em conta esta nova realidade surge a necessidade de procurar alternativas mais viáveis. A alternativa proposta, não é nada mais do que uma “revisão eficiente” dos atuais sistemas em vigor, permitindo assim aos pequenos produtores, atenuar os consumos energéticos e injetar na rede os excedentes de energia. O Autoconsumo revoluciona assim os atuais mecanismos existentes, garantindo deste modo que os consumidores de EE possam reduzir a sua fatura de eletricidade através da geração local de energia.
Resumo:
The high penetration of distributed energy resources (DER) in distribution networks and the competitive environment of electricity markets impose the use of new approaches in several domains. The network cost allocation, traditionally used in transmission networks, should be adapted and used in the distribution networks considering the specifications of the connected resources. The main goal is to develop a fairer methodology trying to distribute the distribution network use costs to all players which are using the network in each period. In this paper, a model considering different type of costs (fixed, losses, and congestion costs) is proposed comprising the use of a large set of DER, namely distributed generation (DG), demand response (DR) of direct load control type, energy storage systems (ESS), and electric vehicles with capability of discharging energy to the network, which is known as vehicle-to-grid (V2G). The proposed model includes three distinct phases of operation. The first phase of the model consists in an economic dispatch based on an AC optimal power flow (AC-OPF); in the second phase Kirschen's and Bialek's tracing algorithms are used and compared to evaluate the impact of each resource in the network. Finally, the MW-mile method is used in the third phase of the proposed model. A distribution network of 33 buses with large penetration of DER is used to illustrate the application of the proposed model.
Resumo:
Thesis submitted to the Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia for the degree of Doctor of Philosophy in Environmental Engineering