999 resultados para Assistência médica - Avaliação


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The humanization of childbirth implies the understanding of this event as an important experience, and requires the redefinition of human relationships from the review of the assistance project, the understanding of pregnant women condition and human rights. To evaluate child birth assistance using a score that was developed by Botucatu Cuesta Regional Management and Jurumirim Valley Collegiates. This is an epidemiological, descriptive study that is inserted in the field of evaluation of services, programs or health projects. The data has been obtained by direct observation of deliveries, emphasizing the humane care. Results: Approximately one third of the women gave birth in a tertiary hospital (34.1%) and it was their first babies (33%).24.8% of the women received prenatal care in high-risk services. 67.1% of the births were normal, and 84.7% had no companions in the delivery room. In 47.1% of the cases the delivery was performed by obstetrician who used anesthesia in 44.7% and episiotomy in 48.2% of the deliveries. More than half of the newborns were attended by the pediatrician in the delivery room and had a delivery graph completed. Although the present study shows that 67.1% of the births were normal, caesarean rate can be considered excessive, as the WHO points out that c-sections above 15% are unlikely to be justifiable. It is important to emphasize that the Ministry of Health has to have a commitment with all women to promote safe motherhood, even in cases when the pregnancy involves a risk for both the mother and the fetus. It is noteworthy that the created score allowed us to assess variables related to the humanization of childbirth and only average and quite similar situations among the three services were evidenced. We hope that with this study, managers and professionals that work in this area can be subsidized in order to offer effective humane assistance and quality service in the delivery

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The gastrointestinal tract is the main route of nutrients absorption and drugs delivery. Is important to know the parameters related to the tract, like gastric emptying and gastrointestinal transit, in order to better understand the behavior of different kind of meals or drugs passing through the GIT. Many techniques are used to study these parameters, such as manometry, scintigraphy, phenol red, activated charcoal and carbon-13 reading. However, these methods use radiation, are invasive and require animal sacrifice. As an alternative proposal, the Alternate Current Biosusceptometry (ACB), a magnetic technique, has proved to be effective for these studies with small animals, in a noninvasive way, low cost, radiation free and avoiding the animal death. Associating the ACB to magnetic micro or nanoparticles used as tracers, it is possible to observe the meal behavior inside of the GIT. Focusing meanly on liquid meals digestion, this paper had the objective to evaluate the efficiency of the ACB technique in gastric emptying and gastrointestinal transit evaluation of liquid meals in rats. To perform the experiments, magnetic nanoparticles (ferrite, MgFe2O4) were used on a 1,5 ml solution introduced by gavage on similar weight and age rats. The sensor made by 2 pairs of coils, capable of generating and detecting magnetic fields, creates a field on the interest place and when this field is in contact with the marked meal, it changes, resulting on a variation of the measured voltage. The voltage variation is analyzed and is obtained a particle concentration on the interest region. The results showed that is possible to apply the ACB technique on the GIT evaluation of liquid particles digestion, gastric emptying and meal cecum arrival time curves were obtained and from that, is possible to observe a pattern of gastrointestinal transit. Both mean process time values were acquired, proving the technique capability of ...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The 131I (radioactive iodine) is one of the most used radionuclides in nuclear medicine for diagnosis and treatment. The present study evaluates the dosimetric aspects related to radioiodine therapy after thyroidectomy in patients with thyroid cancer. The samples were studied with 50 patients undergoing treatment, by assessing the exposures of workers (nursing assistants, staff hygiene, medical and physical), the general public (accompanying and family members) and on the environment. To evaluate the workers, was made a survey of the environmental conditions of the room radioiodine and routines adopted by them during the treatment period. Estimating the dose equivalent per month for each employee, we observed that the maximum levels obtained for nursing assistants, the team of hygiene, medical and physicians were considered low in relation to the extent permitted by law. In order to assess the public, some situations have been suggested for the calculation of equivalent doses in which it was possible to verify the fundamental importance of isolating the patient in the 2 days first. Regarding the environment, the radioactive waste generated by patient had volume of 1.0 m3 and activity estimated at 0.91 mCi, taking a decay time for eliminating them about 75 days to reach the allowable value of 2 μCi / kg system of collecting garbage. Therefore, all radioactive waste removed from the patient's room should be sent to the warehouse for temporary storage of radioactive waste, located away from normal work areas

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aims to determine surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence dosimetry. Twenty seven exams from different dogs were performed at the Faculdade de Medicina Veterinária e Zootecnia da Universidade Estadual Paulista (FMVZ-UNESP/Botucatu). The doses were evaluated using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN). The pulmonary metastasis exams are carried out in three projections, one dorsal-ventral and two lateral-lateral. During the procedures the projection thicknesses and source-skin surface distances were registered. To simulate the dog phantom the dosimeters were positioned in a cubic simulator (30x30x30 cm) of polymethylmethacrylate (PMMA) filled with water and irradiated according to the parameters of projections with the X-ray energies ranging from 45 to 70 kV. To estimate the surface skin dose the dose-response curves were obtained for X-ray energies of 50 and 70 kV using the diagnostic X-ray beam machine of the Instruments Calibration Laboratory of IPEN for doses of 1.5, 2.0, 2.5, 3.5 and 4.0 mGy. The main difficulty of this work was the dog immobilization that is reflected in poor-quality diagnostic imaging and, consequently, demands the repetition of the exams, which contributes to the increase of the doses received by the animals being studied and the clinical staff. The doses evaluated in this type of procedure are between 0.43 and 4.22 mGy. This research has shown to be extremely important for the assessment of doses involved in veterinary diagnostic radiology procedures, and as a parameter in the individual monitoring of pet’s owners who assist the animal positioning and occupationally exposed workers of the Department of Veterinary Radiology

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An experimental study in dogs was accomplished to evaluate impedances at the acupuncture points and the relative false points. According to the physics concepts and the Ohm’ Law, an electrical circuit was set up to determine the impedance. This circuit was introduced into three experiments in anesthetized dogs with needles at selected points. In the first two experiments, was applied an alternating tension with 200Hz frequency in the circuit and, in the last experiment, the frequency was increased to 10kHz, the tensions and electrical currents were measured between every pair of points for the all experiments. The impedances were calculated with the values obtained by experiments. The analysis of impedance values indicated that there is a coherent relation between the results and the applied frequencies in circuit, so just at high frequency condition admits the correct measurement of total impedance, therefore the last experiment gave the result which agreed with the theory, that the impedances at acupuncture points are lower than the impedances at false points

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper consists in the evaluation of the exposure rate to ionizing radiation to which professionals working in surgical procedures which require radiological examinations are subjected. Were initially performed real-time readings of exposure rate within four distinct operating rooms during the execution of four surgical procedures that made use of fluoroscopy equipment (including three orthopedic surgeries, one in the shoulder, one in the arm, another for deployment of metal pin in the leg region, and a fourth for vascular procedure); in these surgeries were used ionization chamber detector and an electrometer. In order to check the values achieved, was made a re-evaluation of the distribution of the rate of exposure to radiation, from the surgical procedures, now with thermoluminescent dosimeters (TLDs). For this, thirty TLDs were distributed in the operating rooms, arranged in points of interest as occupation by professionals. The TLDs were prepared for thirty consecutive days, after which they were removed and replaced with new dosimeters not exposed yet. The dosimeters were subjected to reading of the rate of exposure; this procedure was repeated for four months without interruption. The quantification of the results sought primarily to convert the rate of exposure for equivalent dose rate, both in measurements with ionization chamber as in measurements with TLDs, in order to highlight the presence of the biological effect of ionizing radiation for comparisons within scientific context. Then, the results were plotted to establish the relationship between the values of equivalent dose and the distance to the central axis of the x -ray source, confirming the inverse square law for distance. Finally, the values were associated with the maximum limit recommended by the legislation for occupationally exposed individuals. The methodology for the analysis and quantification of the data in this work aims at implementing a work plan that meets ...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Biociências - FCLAS

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Fisiopatologia em Clínica Médica - FMB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Psychoanalysis was introduced in Brazil since 1920 contributing to the appearance of new practices of health care for the child. Therefore, the present article aims to discuss the link between psychoanalysis and practices focused on children's mental health that emerged from the 1930s through the work of Durval Marcondes, a pioneer in the dissemination and use of psychoanalysis in Brazil. A historical research was held from a survey on Durval Marcondes’s work and the team led by him confined in the epigraph theme. It was found from that work that the link between mental hygiene, new school and psychoanalysis developed a pioneering service of care to children with school problems based on the diagnostic evaluation and guidance of parents and teachers. It is concluded that this work introduced the differentiation between children with cognitive and emotional problems and provided the foundations of psychoeducational and psycodiagnostic interventions.