712 resultados para monochromatic aberrations


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado, Aquacultura, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the most exciting discoveries in astrophysics of the last last decade is of the sheer diversity of planetary systems. These include "hot Jupiters", giant planets so close to their host stars that they orbit once every few days; "Super-Earths", planets with sizes intermediate to those of Earth and Neptune, of which no analogs exist in our own solar system; multi-planet systems with planets smaller than Mars to larger than Jupiter; planets orbiting binary stars; free-floating planets flying through the emptiness of space without any star; even planets orbiting pulsars. Despite these remarkable discoveries, the field is still young, and there are many areas about which precious little is known. In particular, we don't know the planets orbiting Sun-like stars nearest to our own solar system, and we know very little about the compositions of extrasolar planets. This thesis provides developments in those directions, through two instrumentation projects.

The first chapter of this thesis concerns detecting planets in the Solar neighborhood using precision stellar radial velocities, also known as the Doppler technique. We present an analysis determining the most efficient way to detect planets considering factors such as spectral type, wavelengths of observation, spectrograph resolution, observing time, and instrumental sensitivity. We show that G and K dwarfs observed at 400-600 nm are the best targets for surveys complete down to a given planet mass and out to a specified orbital period. Overall we find that M dwarfs observed at 700-800 nm are the best targets for habitable-zone planets, particularly when including the effects of systematic noise floors caused by instrumental imperfections. Somewhat surprisingly, we demonstrate that a modestly sized observatory, with a dedicated observing program, is up to the task of discovering such planets.

We present just such an observatory in the second chapter, called the "MINiature Exoplanet Radial Velocity Array," or MINERVA. We describe the design, which uses a novel multi-aperture approach to increase stability and performance through lower system etendue, as well as keeping costs and time to deployment down. We present calculations of the expected planet yield, and data showing the system performance from our testing and development of the system at Caltech's campus. We also present the motivation, design, and performance of a fiber coupling system for the array, critical for efficiently and reliably bringing light from the telescopes to the spectrograph. We finish by presenting the current status of MINERVA, operational at Mt. Hopkins observatory in Arizona.

The second part of this thesis concerns a very different method of planet detection, direct imaging, which involves discovery and characterization of planets by collecting and analyzing their light. Directly analyzing planetary light is the most promising way to study their atmospheres, formation histories, and compositions. Direct imaging is extremely challenging, as it requires a high performance adaptive optics system to unblur the point-spread function of the parent star through the atmosphere, a coronagraph to suppress stellar diffraction, and image post-processing to remove non-common path "speckle" aberrations that can overwhelm any planetary companions.

To this end, we present the "Stellar Double Coronagraph," or SDC, a flexible coronagraphic platform for use with the 200" Hale telescope. It has two focal and pupil planes, allowing for a number of different observing modes, including multiple vortex phase masks in series for improved contrast and inner working angle behind the obscured aperture of the telescope. We present the motivation, design, performance, and data reduction pipeline of the instrument. In the following chapter, we present some early science results, including the first image of a companion to the star delta Andromeda, which had been previously hypothesized but never seen.

A further chapter presents a wavefront control code developed for the instrument, using the technique of "speckle nulling," which can remove optical aberrations from the system using the deformable mirror of the adaptive optics system. This code allows for improved contrast and inner working angles, and was written in a modular style so as to be portable to other high contrast imaging platforms. We present its performance on optical, near-infrared, and thermal infrared instruments on the Palomar and Keck telescopes, showing how it can improve contrasts by a factor of a few in less than ten iterations.

One of the large challenges in direct imaging is sensing and correcting the electric field in the focal plane to remove scattered light that can be much brighter than any planets. In the last chapter, we present a new method of focal-plane wavefront sensing, combining a coronagraph with a simple phase-shifting interferometer. We present its design and implementation on the Stellar Double Coronagraph, demonstrating its ability to create regions of high contrast by measuring and correcting for optical aberrations in the focal plane. Finally, we derive how it is possible to use the same hardware to distinguish companions from speckle errors using the principles of optical coherence. We present results observing the brown dwarf HD 49197b, demonstrating the ability to detect it despite it being buried in the speckle noise floor. We believe this is the first detection of a substellar companion using the coherence properties of light.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Personal electronic devices, such as cell phones and tablets, continue to decrease in size while the number of features and add-ons keep increasing. One particular feature of great interest is an integrated projector system. Laser pico-projectors have been considered, but the technology has not been developed enough to warrant integration. With new advancements in diode technology and MEMS devices, laser-based projection is currently being advanced for pico-projectors. A primary problem encountered when using a pico-projector is coherent interference known as speckle. Laser speckle can lead to eye irritation and headaches after prolonged viewing. Diffractive optical elements known as diffusers have been examined as a means to lower speckle contrast. Diffusers are often rotated to achieve temporal averaging of the spatial phase pattern provided by diffuser surface. While diffusers are unable to completely eliminate speckle, they can be utilized to decrease the resultant contrast to provide a more visually acceptable image. This dissertation measures the reduction in speckle contrast achievable through the use of diffractive diffusers. A theoretical Fourier optics model is used to provide the diffuser’s stationary and in-motion performance in terms of the resultant contrast level. Contrast measurements of two diffractive diffusers are calculated theoretically and compared with experimental results. In addition, a novel binary diffuser design based on Hadamard matrices will be presented. Using two static in-line Hadamard diffusers eliminates the need for rotation or vibration of the diffuser for temporal averaging. Two Hadamard diffusers were fabricated and contrast values were subsequently measured, showing good agreement with theory and simulated values. Monochromatic speckle contrast values of 0.40 were achieved using the Hadamard diffusers. Finally, color laser projection devices require the use of red, green, and blue laser sources; therefore, using a monochromatic diffractive diffuser may not optimal for color speckle contrast reduction. A simulation of the Hadamard diffusers is conducted to determine the optimum spacing between the two diffusers for polychromatic speckle reduction. Experimental measured results are presented using the optimal spacing of Hadamard diffusers for RGB color speckle reduction, showing 60% reduction in contrast.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is an Olympic year and we have just witnessed the fantastic games hosted by Rio de Janeiro. Well done to team USA for winning the most medals overall but also well done to so many other nations and individuals who performed so well or were ambassadors in other ways. Teenage swimmer Yusra Mardini who swam for the refugee team and South Africa's Wayde van Niekerk who broke the longstanding 400 m record of Michael Johnson that has stood since 1999. Of course, we must mention sprinter Usain Bolt and swimmer Michael Phelps, who have now transcended superstar status and entered a new level of icon. My personal highlight was the sportsmanship witnessed in the 5000 m when American Abbey D’Agostino was accidentally felled by New Zealand runner Nikki Hamblin. D’Agostino helped Hamblin back to her feet but slumped to the track after realising her own injury. Hamblin helped her up and stayed with her so that both completed the race. The International Olympic Committee has awarded both with the prestigious Pierre de Coubertin award, also known as the International Fair Play Trophy. Fair play is of paramount importance in publishing in peer-reviewed papers. At CLAE we try and maintain, as do other journals, this by ensuring double blind peer review and allowing authors to select the most appropriate handling editor for their submission. Our handling editors are placed across the world (2 in Europe, 1 in the Americas, 1 in Australia and 1 in Asia) and part of their role is to encourage submissions from their region. Over the last decade we certainly have seen more and more papers from places that haven’t previously published in CLAE. In this issue of CLAE we have a true international blend of papers. We have papers from authors from the UK, USA, Iran, Jordan, France, Poland, Turkey, Nigeria, France, Spain and Brazil. I think it's a testament to the continued success of the journal that we are attracting new writers from so many parts of the world and retain papers from more established authors and research centres. We do continue to attract many weaker papers that are rejected early in the review process. Often these will be unexceptional case reports or papers describing a surgical technique. Case reports are published but only those that offer something original and especially those with interesting photographs. In this issue you will see Professor James Wolffsohn (UK) has an interesting paper around a lot of the focus of his recent research activity into clinical evaluation of methods of correcting presbyopia. In this paper he highlights predictors to aid success of presbyopic contact lenses. If you have been involved in any clinical work or research in the field of dry eye disease then you will know well the CLDEQ (Contact Lens Dry Eye Questionnaire) devised by Robin Chalmers and her colleagues (USA). This issue of CLAE details the latest research using the CLDEQ-8 (the 8 item version of the CLDEQ). The Shahroud Eye Cohort Study has produced many papers already and in this issue we see Fotouhi Akbar (Iran) looking at changes in central and peripheral corneal thickness over a five year period. These days we use a lot of new instrumentation, such as optical low-coherence reflectometry. In this issue Emre Güler (Turkey) compares that to a new optical biometry unit. Dry eye is more common and in this issue we see a study by Oluyemi Fasina (Nigeria) to investigate the disease in adults in South-West Nigeria. The TearLab™ is now commonly used to investigate osmolarity and Dorota Szczesna-Iskander (Poland) looks at measurement variability of this device. Following the theme of dry eyes and tear testing Renaud Laballe (France) looks at the use of scleral lenses as a reservoir-based ocular therapeutic system. In this issue we have a couple of papers looking at different aspects of keratoconus. Magdalena Popiela (UK) looks at demographics of older keratoconic patients in Wales, Faik Orucoglu (Turkey) reports a novel scoring system for distinguishing keratoconus from normal eyes, Gonzalo Carracedo (Spain) reports the effect of rigid gas permeable lens wear on dry eye in keratoconus and Hatice Nur Colak (Turkey) compares topographic and aberrations in keratoconus. Other interesting papers you will find are Mera Haddad (Jordan) investigates contact lens prescribing in Jordan, Camilla Fraga Amaral (Brazil) offers a report on the use of ocular prosthetics, Naveed Ahmed Khan (Malaysia) reports of the use of dimethyl sulfoxide in contact lens disinfectant and Michael Killpartrick (UK) offers a short piece with some useful advice on contamination risk factors that may occur from the posterior surface of disposable lenses. So for this issue I would say that the Gold Medal for biggest contribution in terms of papers has to go to Turkey. I could have awarded it to the UK too, but Turkey has three full papers and the UK has two plus one short communication. Turkey is also one of the countries that has shown the largest increase in submissions over the last decade. Finally, welcome aboard to our newest Editorial Board Member Nicole Carnt from Australia. Nicole has been an active researcher for many years and acted as a reviewer for CLAE many times in the past. We look forward to working with you.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background In recent years new models of intraocular lenses are appearing on the market to reduce requirements for additional optical correction. The purpose of this study is to assess visual outcomes following bilateral cataract surgery and the implant of a FineVision® trifocal intraocular lens (IOL). Methods Prospective, nonrandomized, observational study. Vision was assessed in 44 eyes of 22 patients (mean age 68.4 ± 5.5 years) before and 3 months after surgery. Aberrations were determined using the Topcon KR-1 W wave-front analyzer. LogMAR visual acuity was measured at distance (corrected distance visual acuity, CDVA 4 m), intermediate (distance corrected intermediate visual acuity, DCIVA 60 cm) and near (distance corrected near visual acuity, DCNVA 40 cm). The Pelli-Robson letter chart and the CSV-1000 test were used to estimate contrast sensitivity (CS). Defocus curve testing was performed in photopic and mesopic conditions. Adverse photic phenomena were assessed using the Halo v1.0 program. Results Mean aberration values for a mesopic pupil diameter were: total HOA RMS: 0.41 ± 0.30 μm, coma: 0.32 ± 0.22 μm and spherical aberration: 0.21 ± 0.20 μm. Binocular logMAR measurements were: CDVA −0.05 ± 0.05, DCIVA 0.15 ± 0.10, and DCNVA 0.06 ± 0.10. Mean Pelli-Robson CS was 1.40 ± 0.14 log units. Mean CSV100 CS for the 4 frequencies examined (A: 3 cycles/degree (cpd), B: 6 cpd, C: 12 cpd, D: 18 cpd) were 1.64 ± 0.14, 1.77 ± 0.18, 1.44 ± 0.24 and 0.98 ± 0.24 log units, respectively. Significant differences were observed in defocus curves for photopic and mesopic conditions (p < 0.0001). A mean disturbance index of 0.28 ± 0.22 was obtained. Conclusions Bilateral FineVision IOL implant achieved a full range of adequate vision, satisfactory contrast sensitivity, and a lack of significant adverse photic phenomena. Trial registration Eudract Clinical Trials Registry Number: 2014-003266-2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Le développement au cours des dernières décennies de lasers à fibre à verrouillage de modes permet aujourd’hui d’avoir accès à des sources fiables d’impulsions femtosecondes qui sont utilisées autant dans les laboratoires de recherche que pour des applications commerciales. Grâce à leur large bande passante ainsi qu’à leur excellente dissipation de chaleur, les fibres dopées avec des ions de terres rares ont permis l’amplification et la génération d’impulsions brèves de haute énergie avec une forte cadence. Cependant, les effets non linéaires causés par la faible taille du faisceau dans la fibre ainsi que la saturation de l’inversion de population du milieu compliquent l’utilisation d’amplificateurs fibrés pour l’obtention d’impulsions brèves dont l’énergie dépasse le millijoule. Diverses stratégies comme l’étirement des impulsions à des durées de l’ordre de la nanoseconde, l’utilisation de fibres à cristaux photoniques ayant un coeur plus large et l’amplification en parallèle ont permis de contourner ces limitations pour obtenir des impulsions de quelques millijoules ayant une durée inférieure à la picoseconde. Ce mémoire de maîtrise présente une nouvelle approche pour l’amplification d’impulsions brèves utilisant la diffusion Raman des verres de silice comme milieu de gain. Il est connu que cet effet non linéaire permet l’amplification avec une large bande passante et ce dernier est d’ailleurs couramment utilisé aujourd’hui dans les réseaux de télécommunications par fibre optique. Puisque l’adaptation des schémas d’amplification Raman existants aux impulsions brèves de haute énergie n’est pas directe, on propose plutôt un schéma consistant à transférer l’énergie d’une impulsion pompe quasi monochromatique à une impulsion signal brève étirée avec une dérive en fréquence. Afin d’évaluer le potentiel du gain Raman pour l’amplification d’impulsions brèves, ce mémoire présente un modèle analytique permettant de prédire les caractéristiques de l’impulsion amplifiée selon celles de la pompe et le milieu dans lequel elles se propagent. On trouve alors que la bande passante élevée du gain Raman des verres de silice ainsi que sa saturation inhomogène permettent l’amplification d’impulsions signal à une énergie comparable à celle de la pompe tout en conservant une largeur spectrale élevée supportant la compression à des durées très brèves. Quelques variantes du schéma d’amplification sont proposées, et leur potentiel est évalué par l’utilisation du modèle analytique ou de simulations numériques. On prédit analytiquement et numériquement l’amplification Raman d’impulsions à des énergies de quelques millijoules, dont la durée est inférieure à 150 fs et dont la puissance crête avoisine 20 GW.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción. Los trabajadores de los talleres de reparación de automóviles conviven diariamente con la exposición a los solventes orgánicos, exposición que se convierte en un riesgo para su salud que generalmente en el corto plazo se presenta como déficits de concentración, memoria y tiempo de reacción y en el largo plazo produciendo graves repercusiones clínicas como efectos mutagénicos y carcinogénicos. Objetivo. Caracterizar las condiciones higiénicas y de seguridad de trabajadores ocupacionalmente expuestos a solventes orgánicos y determinar los niveles ambientales de benceno, tolueno y xileno (BTX) en talleres de lámina y pintura automotriz de la ciudad de Bogotá. Materiales y métodos. Se hizo un estudio de corte transversal en 60 trabajadores que laboran expuestos a solventes orgánicos en talleres de reparación automotriz en Bogotá. Se realizó una encuesta con variables sociodemográficas, laborales y se determinaron los niveles en aire de benceno, tolueno y xileno. Para los muestreos ambientales, las bombas se colocaron en una posición fija representativa del ambiente general, con el objeto de conocer la distribución de los solventes en el área de trabajo. Se realizó un análisis descriptivo por conteos de frecuencia, medidas de tendencia central y dispersión. Se utilizó prueba de bondad de ajuste para distribución normal (Kolmogorov-Smirnov o Shapiro Wilk), prueba t Student para comparación de medias, o en su defecto prueba U de Mann Whitney para comparación de medianas. Para identificar la relación entre las características sociodemográficas y ocupacionales con la exposición a BTX, se utilizaron pruebas de asociación Chi cuadrado o análisis de correlación según la naturaleza de las variables. El nivel de significancia para cada prueba fue 0.05. Resultados. La edad promedio de los trabajadores fue de 43 años y un tiempo total de exposición a solventes de 20 años. Respecto al uso de protección corporal, 45 (75%) de los trabajadores manifestaron que usaban uniforme, mientras que 14 (23,3%) usaban ropa de calle durante la jornada laboral. El 46,7% manifestaron usar protección respiratoria. La concentración de benceno en aire fue entre 0,1 y 0,45 mg/l (mediana de 0,31 mg/l; DE 0,13 mg/l); la de tolueno estuvo entre 8,25 y 27,22 mg/l (mediana de 14,5 mg/l; DE 6.99 mg/l) y la de xileno entre 19,34 y 150,15 mg/l (mediana de 70,12 mg/l; DE 40,82 mg/l). Conclusión. Los pintores de automóviles están expuestos a niveles elevados de solventes en los lugares de trabajo y no cuentan con condiciones de higiene y seguridad industrial adecuados. Un gran número de pintores son informales lo que les impide el acceso a los beneficios del Sistema de Seguridad Social Integral.