940 resultados para functionality indicator
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores
Resumo:
In this paper we present results on the use of a semiconductor heterostructure based on a-SiC:H as a wavelength-division demultiplexer for the visible light spectrum. The proposed device is composed of two stacked p-i-n photodiodes with intrinsic absorber regions adjusted to short and long wavelength absorption and carrier collection. An optoelectronic characterisation of the device was performed in the visible spectrum. Demonstration of the device functionality for WDM applications was done with three different input channels covering the long, the medium and the short wavelengths in the visible range. The recovery of the input channels is explained using the photocurrent spectral dependence on the applied voltage. An electrical model of the WDM device is proposed and supported by the solution of the respective circuit equations. Short range optical communications constitute the major application field however other applications are foreseen. (C) 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Resumo:
Dissertação apresentada à Escola Superior de Educação de Lisboa para obtenção do grau de mestre em Ciências da Educação - Especialidade Educação Especial
Resumo:
In this paper we present results on the use of a multilayered a-SiC:H heterostructure as a wavelength-division demultiplexing device (WDM) for the visible light spectrum. The WDM device is a glass/ITO/a-SiC:H (p-i-n)/ a-SiC:H(-p) /Si:H(-i)/SiC:H (-n)/ITO heterostructure in which the generated photocurrent at different values of the applied bias can be assigned to the different optical signals. The device was characterized through spectral response measurements, under different electrical bias. Demonstration of the device functionality for WDM applications was done with three different input channels covering wavelengths within the visible range. The recovery of the input channels is explained using the photocurrent spectral dependence on the applied voltage. The influence of the optical power density was also analysed. An electrical model, supported by a numerical simulation explains the device operation. Short range optical communications constitute the major application field, however other applications are also foreseen.
Resumo:
This paper presents a novel moving target indicator which is selective with respect to a direction of interest. Preliminary results indicate that the obtained selectivity may have high interest in civil traffic monitoring using single channel SAR data.
Resumo:
Tese de Doutoramento, Ciências do Mar (Biologia Marinha)
Resumo:
In this work the identification and diagnosis of various stages of chronic liver disease is addressed. The classification results of a support vector machine, a decision tree and a k-nearest neighbor classifier are compared. Ultrasound image intensity and textural features are jointly used with clinical and laboratorial data in the staging process. The classifiers training is performed by using a population of 97 patients at six different stages of chronic liver disease and a leave-one-out cross-validation strategy. The best results are obtained using the support vector machine with a radial-basis kernel, with 73.20% of overall accuracy. The good performance of the method is a promising indicator that it can be used, in a non invasive way, to provide reliable information about the chronic liver disease staging.
Resumo:
In this work liver contour is semi-automatically segmented and quantified in order to help the identification and diagnosis of diffuse liver disease. The features extracted from the liver contour are jointly used with clinical and laboratorial data in the staging process. The classification results of a support vector machine, a Bayesian and a k-nearest neighbor classifier are compared. A population of 88 patients at five different stages of diffuse liver disease and a leave-one-out cross-validation strategy are used in the classification process. The best results are obtained using the k-nearest neighbor classifier, with an overall accuracy of 80.68%. The good performance of the proposed method shows a reliable indicator that can improve the information in the staging of diffuse liver disease.
Resumo:
Beaches worldwide provide recreational opportunities to hundreds of millions of people and serve as important components of coastal economies. Beach water is often monitored for microbiological quality to detect the presence of indicators of human sewage contamination so as to prevent public health outbreaks associated with water contact. However, growing evidence suggests that beach sand can harbor microbes harmful to human health, often in concentrations greater than the beach water. Currently, there are no standards for monitoring, sampling, analyzing, or managing beach sand quality. In addition to indicator microbes, growing evidence has identified pathogenic bacteria, viruses, and fungi in a variety of beach sands worldwide. The public health threat associated with these populations through direct and indirect contact is unknown because so little research has been conducted relating to health outcomes associated with sand quality. In this manuscript, we present the consensus findings of a workshop of experts convened in Lisbon, Portugal to discuss the current state of knowledge on beach sand microbiological quality and to develop suggestions for standardizing the evaluation of sand at coastal beaches. The expert group at the "Microareias 2012" workshop recommends that 1) beach sand should be screened for a variety of pathogens harmful to human health, and sand monitoring should then be initiated alongside regular water monitoring; 2) sampling and analysis protocols should be standardized to allow proper comparisons among beach locations; and 3) further studies are needed to estimate human health risk with exposure to contaminated beach sand. Much of the manuscript is focused on research specific to Portugal, but similar results have been found elsewhere, and the findings have worldwide implications.
Resumo:
Dissertação de Mestrado em Ciências Económicas e Empresariais
Resumo:
Mestrado (PESII), Educação Pré-Escolar e Ensino do 1º Ciclo do Ensino Básico
Resumo:
Dissertação de Mestrado em Gerontologia Social
Resumo:
A funcionalidade dos indivíduos com Paralisia Cerebral está muitas vezes comprometida devido às alterações do movimento e do controlo postural. Dadas estas alterações, a posição de sentado oferece uma maior estabilidade sendo muitas das atividades de vida diária desempenhadas nesta posição. O objetivo mais importante de intervenção é obter o máximo de funcionalidade na posição de sentado, particularmente do membro superior. Este objectivo, na maioria das vezes, só pode ser atingido com o uso de sistemas de posicionamento que tentam colmatar as alterações posturais e do movimento. Assim, o objetivo deste estudo de caso é verificar se existem diferenças no comportamento motor do tronco e do membro superior, com um sistema de posicionamento rígido e com um sistema de posicionamento dinâmico, numa jovem com Paralisia Cerebral, aquando da ativação manual de um switch. Foi realizado um estudo de caso único em que foi feita uma análise cinemática do movimento do tronco e membro superior na ativação de um switch BigMack, em três posições de teste com distâncias diferentes. Simultaneamente mediu-se a distribuição do peso durante o movimento, através do mapa de pressão e foi registada, bilateralmente a atividade dos músculos trapézio (porção média), longuíssimo, recto abdominal e oblíquo externo. Os resultados obtidos apontam, neste caso em particular, para uma melhoria na qualidade do movimento e da distribuição de peso, com o sistema de posicionamento dinâmico, sem diferenças entre os dois sistemas relativamente à ativação muscular.
Resumo:
Trabalho Final de mestrado para obtenção do grau de Mestre em Engenharia Civil
Resumo:
The basic function of the human hand is the manipulation and grasping of various objects in all daily activities, including work activities. This is greatly influenced by strength and manual dexterity. However age, gender and other contexts such as work or leisure activities could influence strength. Handgrip strength, a measure of maximum voluntary force of the hand, has proved to be reliable and valid as an objective parameter to evaluate the functional integrity of the hand as part of the musculoskeletal system. It correlates highly with strength in other muscular groups and is therefore considered as a good indicator of overall muscular strength and functional stress and could be used as a predictor of physical disability. Handgrip strength assessment is simple and reliable and used commonly by several investigators and health professionals, in different contexts (medical, nutritional, rehabilitation, professional settings, engineering, etc.) and with different purposes (research, diagnostic, assessment, etc.). In clinical and rehabilitation settings is of vital importance in the determination of effectiveness of several interventions and for monitoring evolution of diseases. Various ways (methods, techniques and equipments) of collecting information on grip strength have been reported. This chapter will review basic concepts on handgrip function, methodologies of assessment, contexts of application and correlates, such as physical activity, health or nutritional status. Several populations and reference values as also the relationships between handgrip and clinical status, aging, risk of disability and diseases, will be discussed.