999 resultados para Transporte rodoviario - Pantanal Mato-Grossense (MS)
Resumo:
This study used for the first time LC-MS/MS for the analysis of mitragynine (MIT), a mu-opioid agonist with antinociceptive and antitussive properties, in rat plasma. Mitragynine and the internal standard (amitriptyline) were extracted from plasma with hexane-isoamyl alcohol and resolved on a Lichrospher (R) RP-SelectB column (9.80 and 12.90 min, respectively). The quantification limit was 0.2 ng/mL within a linear range of 0.2-1000 ng/mL The method was applied to quantify mitragynine in plasma samples of rats (n = 8 per sampling time) treated with a single oral dose of 20 mg/kg. The following pharmacokinetic parameters were obtained (mean): maximum plasma concentration: 424 ng/mL; time to reach maximum plasma concentration: 1.26 h; elimination half-life: 3.85 h, apparent total clearance: 6.35 L/h/kg, and apparent volume of distribution: 37.90 L/kg. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Multiple sclerosis (MS) is a complex neurological disease that affects the central nervous system (CNS) resulting in debilitating neuropathology. Pathogenesis is primarily defined by CNS inflammation and demyelination of nerve axons. Methionine synthase reductase (MTRR) is an enzyme that catalyzes the remethylation of homocysteine (Hcy) to methionine via cobalamin and folate dependant reactions. Cobalamin acts as an intermediate methyl carrier between methylenetetrahydrofolate reductase (MTHFR) and Hcy. MTRR plays a critical role in maintaining cobalamin in an active form and is consequently an important determinant of total plasma Hcy (pHcy) concentrations. Elevated intracellular pHcy levels have been suggested to play a role in CNS dysfunction, neurodegenerative, and cerebrovascular diseases. Our investigation entailed the genotyping of a cohort of 140 cases and matched controls for MTRR and MTHFR, by restriction length polymorphism (RFLP) techniques. Two polymorphisms: MTRR A66G and MTHFR A1298C were investigated in an Australian age and gender matched case-control study. No significant allelic frequency difference was observed between cases and controls at the α = 0.05 level (MTRR χ^2 = 0.005, P = 0.95, MTHFR χ^2 = 1.15, P = 0.28). Our preliminary findings suggest no association between the MTRR A66G and MTHFR A1298C polymorphisms and MS.
Resumo:
Joint pedological, geochemical, hydrological and geophysical investigations were performed to study the coexistence or saline and freshwater lakes in close proximity and similar climatic conditions in the Nhecolandia region, Pantanal wetlands in Brazil. The saline lakes are concentrically surrounded by green sandy loam horizons, which cause differential hydrological regimes. Mg-calcite, K-silicates, and amorphous silica precipitate in the soil cover, whereas Mg-silicates and more soluble Na-carbonates are concentrated in the topsoil along the shore of the saline lake. In saline solutions, some minor elements (As, Se) reach values above the water quality recommendations, whereas others are controlled and incorporated in solid phases (Ba, Sr). Locally, the destruction of the sandy loam horizons generates very acidic soil solution (pH similar to 3.5) through a process not yet understood. The soil distributions indicate that some freshwater lakes are former saline lakes. They are invaded by freshwater after destruction of the sandy loam green horizons, then the freshwater becomes enriched in K(+), SO(4)(2-), Fe, Al, and a stream of minor and trace elements. The formation of these green sandy loam horizons in the saline environment and their destruction in the non-saline one emphasizes the dynamic nature of this environment (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Smectite formation in alkaline-saline environments has been attributed to direct precipitation from solution and/or transformation from precursor minerals, but these mechanisms are not universally agreed upon in the literature. The objective of this work was to investigate the mineralogy of smectites in the soils surrounding a representative alkaline-saline lake of Nhecolandia, a sub-region of the Pantanal wetland, Brazil, and then to identify the mechanisms of their formation. Soils were sampled along a toposequence and analyzed by X-ray diffraction, transmission electron microscopy-energy dispersive X-ray analysis, and inductively coupled plasma-mass spectrometry. Water was collected along a transect involving the studied toposequence and equilibrium diagrams were calculated using the databases PHREEQC and AQUA. The fine-clay fraction is dominated by smectite, mica, and kaolinite. Smectites are concentrated at two places in the toposequence: an upper zone, which includes the soil horizons rarely reached by the lake-level variation; and a lower zone, which includes the surface horizon within the area of seasonal lake-level variation. Within the upper zone, the smectite is dioctahedral, rich in Al and Fe, and is classified as ferribeidellite. This phase is interstratified with mica and vermiculite and has an Fe content similar to that of the mica identified. These characteristics suggest that the ferribeidellite originates from transformation of micas and that vermiculite is an intermediate phase in this transformation. Within the lower zone, smectites are dominantly trioctahedral, Mg-rich, and are saponitic and stevensitic minerals. In addition, samples enriched in these minerals have much smaller rare-earth element (REE) contents than other soil samples. The water chemistry shows a geochemical control of Mg and saturation with respect to Mg-smectites in the more saline waters. The REE contents, water chemistry, and the presence of Mg-smectite where maximum evaporation is expected, suggest that saponitic and stevensitic minerals originate by chemical precipitation from the water column of the alkaline-saline lake.
Resumo:
Marsh deer (Blastocerus dichotomus) is one of the most exposed large mammals in South America. To aid in the conservation management of the species, nine polymorphic microsatellite loci were isolated and tested on up to 50 animals, showing 3-12 alleles and expected heterozygosity values varying from 0.69 to 0.89. These markers should be of considerable utility in future population and ecological genetics studies of this species. The marsh deer (Blastocerus dichotomus) is the biggest South American species of deer. Originally distributed across a large part of South America, stretching from the south bank of the Amazon river to northern Argentina, significant wild populations are now restricted to the Pantanal, swamplands that cover about 40% of southwest Brazil. The marsh deer is listed as Vulnerable on the Red List of the IUCN. Three populations of the species from three areas in the Parana River basin (between the states of Sao Paulo and Mato Grosso do Sul) were recently studied by observing protein polymorphism at 17 loci (Oliveira et al. 2005). Now we are presenting data about isolation of microsatellite markers to improve the results regarding population structure.
Resumo:
This article describes the enantioseleclive analysis of cyclophosphamide (CPA) in human plasma using LC-MS/MS. CPA enantiomers were extracted from plasma using a mixture of ethyl acetate and chloroform (75:25, v/v). The enantiomers were separated on a Chiralcel(R) OD-R column, with the mobile phase consisting of a mixture of acetonitrile and water (75:25, v/v) plus 0.2% formic acid. The protonaled ions and their respective product ions were monitored using two functions, 261 > 141 for CPA enantiomers and 189 > 104 for the internal standard (antipyrine). Recovery rates were higher than 95% and the quantification limit was 2.5-ng/ml plasma for both enantiomers. The coefficients of variation and the relative errors obtained for the validation of intra- and interassay precision and accuracy were less than 10%. The method was applied for the investigation of the enantioselective pharmacokinetics of CPA in a lupus nephritis patient treated with 1 g CPA infused over 2 h and in a breast cancer patient treated with 0.9 g infused over 1 h. No stereoselectivity in the pharmacokinetic parameters was observed for either patient. Clearance values of 2.63 and 2.93 l/h and of 3.36 and 3.61 l/h for (-)-(S) and (+)-(R)-CPA were obtained for the breast cancer and lupus nephritis patient., respectively. Chirality 21:383-389, 2009. (C) 2008 Wiley-Liss, Inc.
Resumo:
Labetalol is clinically available as a mixture of two racemates (four stereoisomers). The stereoisomer (R,R) has as main activity the beta(1)-antagonism and the stereoisomer (S,R) is highly selective for the alpha(1) adrenoceptor and is responsible for most of the alpha-blocker activity. In the present investigation, a method for the analysis of labetalol stereoisomers in human plasma was developed and applied to pharmacokinetic studies. Plasma samples (0.5 ml) were extracted with methyl tert-butyl ether at pH 9.5. The four labetalol stereoisomers were analyzed by LC-MS/MS on a Chirobiotic (R) V column using a mobile phase consisting of methanol, acetic acid, and diethylamine, with a recovery of more than 90% for all four. The quantitation limit was 0.5 ng/ml and linearity was observed at 250 ng/ml plasma for each stereoisomer. Studies of precision and accuracy presented coefficients of variation and percentage inaccuracy of less than 15%, indicating that the method is precise and accurate. The method was applied to the study of the kinetic disposition of labetalol over a period of 12 h after oral administration of a single 100 mg dose to a hypertensive pregnant woman. The clinical study revealed stereoselectivity in the pharmacokinetics of labetalol, with a lower plasma proportion for the active stereoisomers (R,R)-labetalol and (S,R)-labetalol. The stereoselectivity observed after oral administration is due to the hepatic metabolism and the first pass effect, with an AUC((R,R))/AUC((S,S)) ratio of 0.5. Chirality 21:738-744, 2009. (C) 2008 Wiley-Liss, Inc.
Resumo:
Considering the importance of neosporosis in the animal health and production, the frequency of antibodies to Neospora caninum was evaluated in dairy cattle of the Southwestern region of Mato Grosso State, Brazil, in addition to serum samples obtained from dogs and humans living in the farms. A total of 1036 serum samples were analyzed, from which 932 were from dairy bovine females, 37 from dogs and 67 from humans, from 24 farms and examined by the indirect fluorescent antibody test (IFAT). Reactive human scrum samples were retested by Western-blotting to confirm the results. Antibodies to N. caninum were found in 499 cattle sera (53.5 %), with at least one positive in each farm, 25 dog sera (67.6 %) and seven human sera (10.5 %). There was no significant difference in the number of positive cattle sera according to age group. The results indicate a wide dissemination of N caninum in the studied region.
Resumo:
Quantitation of progesterone (P(4)) in biological fluids is often performed by radioimmunoassay (RIA), whereas liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) has been used much less often. Due to its autoconfirmatory nature, LC-MS/MS greatly minimizes false positives and interference. Herein we report and compare with RIA an optimized LC-MS/MS method for rapid, efficient, and cost-effective quantitation of P(4) in plasma of cattle with no sample derivatization. The quantitation of plasma P(4) released from three nonbiodegradable, commercial, intravaginal P(4)-releasing devices (IPRD) over 192 h in six ovariectomized cows was compared in a pairwise study as a test case. Both techniques showed similar P(4) kinetics (P > 0.05) whereas results of P(4) quantitation by RIA were consistently higher compared with LC-MS/MS (P < 0.05) due to interference and matrix effects. The LC-MS/MS method was validated according to the recommended analytical standards and displayed P(4) limits of detection (LOD) and quantitation (LOQ) of 0.08 and a 0.25 ng/mL, respectively. The high selective LC-MS/MS method proposed herein for P(4) quantitation eliminates the risks associated with radioactive handling; it also requires no sample derivatization, which is a common requirement for LC-MS/MS quantitation of steroid hormones. Its application to multisteroid assays is also viable, and it is envisaged that it may provide a gold standard technique for hormone quantitation in animal reproductive science studies. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
The isotope composition of Ph is difficult to determine accurately due to the lack of a stable normalisation ratio. Double and triple-spike addition techniques provide one solution and presently yield the most accurate measurements. A number of recent studies have claimed that improved accuracy and precision could also be achieved by multi-collector ICP-MS (MC-ICP-MS) Pb-isotope analysis using the addition of Tl of known isotope composition to Pb samples. In this paper, we verify whether the known isotope composition of Tl can be used for correction of mass discrimination of Pb with an extensive dataset for the NIST standard SRM 981, comparison of MC-ICP-MS with TIMS data, and comparison with three isochrons from different geological environments. When all our NIST SRM 981 data are normalised with one constant Tl-205/Tl-203 of 2.38869, the following averages and reproducibilities were obtained: Pb-207/Pb-206=0.91461+/-18; Pb-208/Ph-206 = 2.1674+/-7; and (PbPh)-Pb-206-Ph-204 = 16.941+/-6. These two sigma standard deviations of the mean correspond to 149, 330, and 374 ppm, respectively. Accuracies relative to triple-spike values are 149, 157, and 52 ppm, respectively, and thus well within uncertainties. The largest component of the uncertainties stems from the Ph data alone and is not caused by differential mass discrimination behaviour of Ph and Tl. In routine operation, variation of sample introduction memory and production of isobaric molecular interferences in the spectrometer's collision cell currently appear to be the ultimate limitation to better reproducibility. Comparative study of five different datasets from actual samples (bullets, international rock standards, carbonates, metamorphic minerals, and sulphide minerals) demonstrates that in most cases geological scatter of the sample exceeds the achieved analytical reproducibility. We observe good agreement between TIMS and MC-ICP-MS data for international rock standards but find that such comparison does not constitute the ultimate. test for the validity of the MC-ICP-MS technique. Two attempted isochrons resulted in geological scatter (in one case small) in excess of analytical reproducibility. However, in one case (leached Great Dyke sulphides) we obtained a true isochron (MSWD = 0.63) age of 2578.3 +/- 0.9 Ma, which is identical to and more precise than a recently published U-Pb zircon age (2579 3 Ma) for a Great Dyke websterite [Earth Planet. Sci. Lett. 180 (2000) 1-12]. Reproducibility of this age by means of an isochron we regard as a robust test of accuracy over a wide dynamic range. We show that reliable and accurate Pb-isotope data can be obtained by careful operation of second-generation MC-ICP magnetic sector mass spectrometers. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
This study compared an enzyme-linked immunosorbent assay (ELISA) to a liquid chromatography-tandem mass spectrometry (LC/MS/MS) technique for measurement of tacrolimus concentrations in adult kidney and liver transplant recipients, and investigated how assay choice influenced pharmacokinetic parameter estimates and drug dosage decisions. Tacrolimus concentrations measured by both ELISA and LC/MS/MS from 29 kidney (n = 98 samples) and 27 liver (n = 97 samples) transplant recipients were used to evaluate the performance of these methods in the clinical setting. Tacrolimus concentrations measured by the two techniques were compared via regression analysis. Population pharmacokinetic models were developed independently using ELISA and LC/MS/MS data from 76 kidney recipients. Derived kinetic parameters were used to formulate typical dosing regimens for concentration targeting. Dosage recommendations for the two assays were compared. The relation between LC/MS/MS and ELISA measurements was best described by the regression equation ELISA = 1.02 . (LC/MS/MS) + 0.14 in kidney recipients, and ELISA = 1.12 . (LC/MS/MS) - 0.87 in liver recipients. ELISA displayed less accuracy than LC/MS/MS at lower tacrolimus concentrations. Population pharmacokinetic models based on ELISA and LC/MS/MS data were similar with residual random errors of 4.1 ng/mL and 3.7 ng/mL, respectively. Assay choice gave rise to dosage prediction differences ranging from 0% to 30%. ELISA measurements of tacrolimus are not automatically interchangeable with LC/MS/MS values. Assay differences were greatest in adult liver recipients, probably reflecting periods of liver dysfunction and impaired biliary secretion of metabolites. While the majority of data collected in this study suggested assay differences in adult kidney recipients were minimal, findings of ELISA dosage underpredictions of up to 25% in the long term must be investigated further.