969 resultados para Scattering Anelastico Neutroni Diffusione Neutrone ILL Diffrattometro Fonone
Resumo:
The R-matrix method describing the scattering of low-energy electrons by complex atoms and ions is extended to include terms of the Breit-Pauli Hamiltonian. An application is made to the astrophysically important 1s 2s S-1s 2s2p P transition in Fe XXIII, where in the most accurate calculations carried out all terms of the 1s 2s, 1s2s2p and 1s2p configurations are included in the expansion describing the collision. This gives up to 28 coupled channels for each total angular momentum and parity which are solved on a CRAY-1. The collision strengths are increased by more than a factor of two from their non-relativistic values at all energies considered.
Resumo:
The relativistic R-matrix method is used to calculate elastic and inelastic cross sections for electrons incident on caesium atoms with energies from 0-3 eV. In addition to the total cross sections, results are presented on the differential cross sections, sigma , and the spin polarisation, P, of the scattered electrons as a function of energy at the scattering angles 10 degrees , 50 degrees , 90 degrees and 150 degrees . The calculation reveals a wealth of resonances around the P and P thresholds. The resonances are analysed in detail and their role in the scattering process is discussed.
Resumo:
Phaseshifts, differential, total and momentum transfer cross sections are calculated using an R-matrix approach for the elastic scattering of electrons by argon atoms in the impact energy range 0-19 eV. The coupled-state calculation is based upon a single-configuration atomic ground-state wavefunction coupled to a P pseudostate. A critical assessment of earlier theoretical and experimental data is made and the conclusion is reached that the present results are the most satisfactory over the entire energy range considered.
Resumo:
Introduction: There are many challenges in delivering rural health services; this is particularly true for the delivery of palliative care. Previous work has identified consistent themes around end-of-life care, including caregiver burden in providing care, the importance of informal care networks and barriers imposed by geography. Despite these well-known barriers, few studies have explored the experience of palliative care in rural settings. The purpose of the present study was to compare the experiences of rural family caregivers actively providing end-of-life care to the experiences of their urban counterparts. Methods: Caregivers' perceived health status, the experience of burden in caregiving, assessment of social supports and the pattern of formal care used by the terminally ill were explored using a consistent and standardized measurement approach. A cross-sectional survey study was conducted with 100 informal caregivers (44 rural, 56 urban) actively providing care to a terminally ill patient recruited from a publicly funded community agency located in northeastern Ontario, Canada. The telephone-based survey included questions assessing: (i) caregiver perceived burden (14-item instrument based on the Caregiver's Burden Scale in End-of-Life Care [CBS-EOLC]); (ii) perceived social support (modified version of the Multidimensional Scale of Perceived Social Support [MSPSS] consisting of 12 items); and (iii) functional status of the care recipient (assessed using the Eastern Collaborative Oncology Group performance scale). Results: Rural and urban caregivers were providing care to recipients with similar functional status; the majority of care recipients were either capable of all self-care or experiencing some limitation in self-care. No group differences were observed for caregiver perceived burden: both rural and urban caregivers reported low levels of burden (CBS-EOLC score of 26.5 [SD=8.1] and 25.0 [SD=9.2], respectively; p=0.41). Urban and rural caregivers also reported similarly high levels of social support (mean MSPSS total score of 4.3 [SD=0.7] and 4.1 [SD=0.8], respectively; p=0.40). Although caregivers across both settings reported using a comparable number of services (rural 4.8 [SD=1.9] vs urban 4.5 [SD=1.8]; p=0.39), the types of services used differed. Rural caregivers reported greater use of family physicians (65.1% vs 40.7%; p=0.02), emergency room visits (31.8% vs 13.0%; p=0.02) and pharmacy services (95.3% vs 70.4%; p=0.002), while urban caregivers reported greater use of caregiver respite services (29.6% vs 11.6%; p=0.03). Conclusion: Through the use of standardized tools, this study explored the experiences of rural informal family caregivers providing palliative care in contrast to the experiences of their urban counterparts. The results of the present study suggest that while there are commonalities to the caregiving experience regardless of setting, key differences also exist. Thus, location is a factor to be considered when implementing palliative care programs and services. © K Brazil, S Kaasalainen, A Williams, C Rodriguez, 2013.
Resumo:
The combinatorial frequency generation by the periodic stacks of magnetically biased semiconductor layers has been modelled in a self-consistent problem formulation, taking into account the nonlinear dynamics of carriers. It is shown that magnetic bias not only renders nonreciprocity of the three-wave mixing process but also significantly enhances the nonlinear interactions in the stacks, especially at the frequencies close to the intrinsic magneto-plasma resonances of the constituent layers. The main mechanisms and properties of the combinatorial frequency generation and emission from the stacks are illustrated by the simulation results, and the effects of the individual layer parameters and the structure arrangement on the stack nonlinear and nonreciprocal response are discussed. © 2014 Elsevier B.V. All rights reserved.
Resumo:
In this paper, we probed surface-enhanced Raman scattering (SERS) and surface-enhanced fluorescence (SEF) from probe molecule Rhodamine 6G (R6G) on self-standing Au nanorod array substrates made using a combination of anodization and potentiostatic electrodeposition. The initial substrates were embedded within a porous alumina template (AAO). By controlling the thickness of the AAO matrix, SEF and SERS were observed exhibiting an inverse relationship. SERS and SEF showed a non-linear response to the removal of AAO matrix due to an inhomogeneous plasmon activity across the nanorod which was supported by FDTD calculations. We showed that by optimizing the level of AAO thickness, we could obtain either maximized SERS, SEF or simultaneously observe both SERS and SEF together.
Resumo:
We report on the investigations of spin wave modes in arrays of densely packed Co nanorods using Brillouin light scattering. We have observed a significant role of spin wave modes along the nanorod axis in contrast to infinite magnetic nanowires. Unusual optical properties featuring an inverted Stokes/anti-Stokes asymmetry of the Brillouin scattering spectra have been observed. The spectrum of spin wave modes in the nanorod array has been calculated and compared with the experiment. Experimental observations are explained in terms of a combined numerical-analytical approach taking into account both the low aspect ratio of individual magnetic nanorods and dipolar magnetic coupling between the nanorods in the array. The optical studies of spin-wave modes in the metamaterials with low aspect ratio nanorods have revealed new magnetic and magneto-optical properties compared to continuous magnetic films or infinite magnetic nanowires. Such magnetic metamaterials are important class of active metamaterials needed for prospective data storage and signal processing applications. (c) 2012 Optical Society of America
Resumo:
We report the investigations of spin wave modes of arrays of Ni and Co nanorods using Brillouin light scattering. We have revealed the significant influence of spin wave modes along the nanorod axis in contrast to infinite magnetic nanowires. Unusual optical properties featuring an inverted Stokes/anti-Stokes asymmetry of the Brillouin scattering spectra have been observed. The spectrum of spin wave modes in the nanorod array has been calculated and compared with the experiment. Experimental observations are explained in terms of a combined numerical-analytical approach taking into account both the low aspect ratio of individual magnetic nanorods and dipolar magnetic coupling between the nanorods in the array. The optical studies of spin-wave modes in nanorod metamaterials with low aspect ratio nanorods have revealed new magnetic and magneto-optical properties compared to continuous magnetic films or infinite magnetic nanowires. Such magnetic artificial materials are important class of active metamaterials needed for prospective data storage and signal processing applications. © 2012 Elsevier B.V.
Resumo:
The radiative decay of surface plasmon polaritons has been investigated in an attempt to characterize the surface roughness of Ag films prepared under different conditions. The polaritons were excited by the method of attenuated total reflection of light. The films were deposited on the face of a 60-degrees BK-7 glass prism at a rate that was deliberately fixed in two different ranges (centred on 0.1 and 10 nm s-1) and in some cases a CaF2 underlayer was used to roughen the film surfaces. The intensity of the scattered light emitted from the opposite face of the films was measured as a function of direction for each using the same sensitivity scale and was correlated with the preparation of the film. It was found that on nominally smooth substrates fast-deposited thinner films give out more light and are deduced to have greater short wavelength (300-600 nm) roughness amplitude. There is also evidence for long wavelenth (7 mum) periodic roughness due to the prism substrate itself. On CaF2 roughened surfaces the light output from the films is further increased and the peak intensity is backward directed with respect to the exciting laser beam direction. Here roughness on a lateral scale of 350 nm is responsible. Also, elastic scattering of surface plasmon polaritons at grain boundaries reduces the light output from fast deposited, small grain, films on CaF2 roughened surfaces. Overall, a consistent picture of roughness induced radiative polariton decay emerges for all cases studied.
Resumo:
The surface roughness of nominally smooth and of randomly roughened thin silver films is characterized using scanning tunneling microscopy and the metal grain size is assessed using transmission electron microscopy. On each type of substrate used, glass or CaF2-roughened glass, the silver films are deposited either very slowly (approximately 0.15 nm s-1) or quite quickly (approximately 2.0 nm s-1). Only silver films deposited on CaF2-roughened glass yield measurable surface-enhanced Raman signals for benzoic acid; the enhancement is brought about by surface field amplification due to the excitation of delocalized surface-plasmon polaritons. However, the surface-enhanced Raman signals obtained from the slow-deposited silver films are significantly better (by about a factor of 3) than those obtained from the fast-deposited silver films on a given CaF2-roughened substrate. The explanation of this observation does not lie with different surface roughness; both types of film yield closely similar data on the scanning tunneling microscope. Rather, it is suggested that the relatively small grain size of the fast-deposited silver films leads to increased elastic scattering of surface-plasmon polaritons at the grain boundaries, with a consequent increase of internal damping. This results in a reduction of the scattered Raman signal.
Resumo:
Background: This is an update of a review last published in Issue 5, 2010, of The Cochrane Library. Reducing weaning time is desirable in minimizing potential complications from mechanical ventilation. Standardized weaning protocols are purported to reduce time spent on mechanical ventilation. However, evidence supporting their use in clinical practice is inconsistent. Objectives: The first objective of this review was to compare the total duration of mechanical ventilation of critically ill adults who were weaned using protocols versus usual (non-protocolized) practice.The second objective was to ascertain differences between protocolized and non-protocolized weaning in outcomes measuring weaning duration, harm (adverse events) and resource use (intensive care unit (ICU) and hospital length of stay, cost).The third objective was to explore, using subgroup analyses, variations in outcomes by type of ICU, type of protocol and approach to delivering the protocol (professional-led or computer-driven). Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library Issue 1, 2014), MEDLINE (1950 to January 2014), EMBASE (1988 to January 2014), CINAHL (1937 to January 2014), LILACS (1982 to January 2014), ISI Web of Science and ISI Conference Proceedings (1970 to February 2014), and reference lists of articles. We did not apply language restrictions. The original search was performed in January 2010 and updated in January 2014.Selection criteriaWe included randomized controlled trials (RCTs) and quasi-RCTs of protocolized weaning versus non-protocolized weaning from mechanical ventilation in critically ill adults. Data collection and analysis: Two authors independently assessed trial quality and extracted data. We performed a priori subgroup and sensitivity analyses. We contacted study authors for additional information. Main results: We included 17 trials (with 2434 patients) in this updated review. The original review included 11 trials. The total geometric mean duration of mechanical ventilation in the protocolized weaning group was on average reduced by 26% compared with the usual care group (N = 14 trials, 95% confidence interval (CI) 13% to 37%, P = 0.0002). Reductions were most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. Weaning duration was reduced by 70% (N = 8 trials, 95% CI 27% to 88%, P = 0.009); and ICU length of stay by 11% (N = 9 trials, 95% CI 3% to 19%, P = 0.01). There was significant heterogeneity among studies for total duration of mechanical ventilation (I2 = 67%, P < 0.0001) and weaning duration (I2 = 97%, P < 0.00001), which could not be explained by subgroup analyses based on type of unit or type of approach. Authors' conclusions: There is evidence of reduced duration of mechanical ventilation, weaning duration and ICU length of stay with use of standardized weaning protocols. Reductions are most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. However, significant heterogeneity among studies indicates caution in generalizing results. Some study authors suggest that organizational context may influence outcomes, however these factors were not considered in all included studies and could not be evaluated. Future trials should consider an evaluation of the process of intervention delivery to distinguish between intervention and implementation effects. There is an important need for further development and research in the neurosurgical population.
Resumo:
IntroductionAutomated weaning systems may improve adaptation of mechanical support for a patient’s ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. Our objective was to compare mechanical ventilator weaning duration for critically ill adults and children when managed with automated systems versus non-automated strategies. Secondary objectives were to determine differences in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events.MethodsElectronic databases were searched to 30 September 2013 without language restrictions. We also searched conference proceedings; trial registration websites; and article reference lists. Two authors independently extracted data and assessed risk of bias. We combined data using random-effects modelling.ResultsWe identified 21 eligible trials totalling 1,676 participants. Pooled data from 16 trials indicated that automated systems reduced the geometric mean weaning duration by 30% (95% confidence interval (CI) 13% to 45%), with substantial heterogeneity (I2 = 87%, P <0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not with surgical populations or using other systems. Automated systems reduced ventilation duration with no heterogeneity (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of effect on mortality, hospital LOS, reintubation, self-extubation and non-invasive ventilation following extubation. Automated systems reduced prolonged mechanical ventilation and tracheostomy. Overall quality of evidence was high.ConclusionsAutomated systems may reduce weaning and ventilation duration and ICU stay. Due to substantial trial heterogeneity an adequately powered, high quality, multi-centre randomized controlled trial is needed.
Resumo:
Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.