944 resultados para OCCUPATIONAL-SAFETY
Resumo:
BACKGROUND: The most common laparoscopic complications are associated with trocar insertion. The purpose of this study was to develop an objective method of evaluating the safety profile of various access devices used in laparoscopic surgery. STUDY DESIGN: In 20 swine, 6 bladed and 2 needle access devices were evaluated. A force profile was determined by measuring the force required to drive the trocar or needle through the fascia and into the peritoneum, at 0 and 10 mmHg. The amount Of tissue deformation, the length of blade exposed, and the duration of exposure were measured using a high-speed digital imaging system. RESULTS: The needle system without the sheath required the least driving force and had the most favorable force profile. In contrast, the bladed, nonretractable trocar system required a higher driving force and a rapid loss of resistance. Insertion under a pneumoperitoneum did not significantly alter the force profile of the various access devices except for the amount of tissue deformation. With the bladed system, the blade itself was exposed for an average of 0.5 to 1.0 seconds for a distance of 4.5 to 5.0 cm. In comparison, the needle system was exposed for 0.2 seconds for a distance of 1.8 cm. CONCLUSIONS: We developed a reproducible method of measuring the forces required to place the access systems, their pattern of resistance loss, and the characteristics of the blade exposure. These parameters may provide an adjunctive and objective measurement of safety, allowing for more direct comparison between various trocar designs. (J Am Coll Surg 2009;209:222-232. (C) 2009 by the American College of Surgeons)
Resumo:
The aim of this study was to investigate the rate of occupational leg swelling depending on the time period of the working day Volumetric variations of the legs of 70 hospital employees, enrolled in three groups, were evaluated. Group I: 35 morning shift workers; Group II: 35 afternoon shift workers; and Group III: 15 individuals randomly selected from Groups I and II, who were evaluated on the day they worked 12 hours consecutively. Volumetry was performed before and after each shift for both legs of the participants in Groups I and II. For Group III volumetry was performed early in the morning, at noon and in the evening, For statistical analysis, the Student`s t-test and Mann-Whitney test were used with an alpha error of 5%. being considered acceptable (P value < 0.05). Significant increases in volume were recorded for the limbs in all three groups (P value < 0.001). On comparing Groups I and II, the accumulation of fluids was significantly higher in the morning than in the afternoon (P value < 0.003). Asymptomatic workers may present with oedema of the legs during their work with the rate of oedema being different for morning and afternoon shifts. The possibility of wearing compression stockings should be considered for this type of work.
Resumo:
Introduction: Pediatric percutaneous renal biopsy (Bx) is a routine procedure in pediatric nephrology to obtain renal tissues for histological study. We evaluated the safety, efficacy, indications and renal findings of this procedure at a tertiary care pediatric university hospital and compared our findings with the literature. Methods: Retrospective study based on medical records from January 1993 to June 2006. Results: In the study period, 305 Bx were performed in 262 patients, 127 (48.5%) male, aged 9.8 +/- 4.2 years. A 16-gauge needle was utilized in 56/305 Bx, an 18-gauge needle in 252/305 Bx (82.6%). 56.1% Bx were performed under sedation plus local anesthesia, 43.9% under general anesthesia. The number of punctures per Bx was 3.1 +/- 1.3. Minor complications occurred in 8.6% procedures. The 16-gauge needle caused a higher frequency of renal hematomas (p = 0.05). The number of glomeruli per puncture was >= 5 in 96.7% and >= 7 in 92%. Glomeruli number per puncture and frequency of complications were not different according to the type of anesthesia used. A renal pathology diagnosis was achieved in 93.1% Bx. The main indications of Bx were nephrotic syndrome (NS), lupus nephritis (LN) and hematuria (HE). The diagnosis of minimal change disease (MCD) (61.3%), class V (35.6%) and IgA nephropathy (26.3%) predominated in NS, LN and HE patients, respectively. Conclusion: Pediatric real-time ultrasound-guided percutaneous renal biopsy was safe and effective. The main clinical indications for Bx were NS and LN, the predominant renal pathology diagnoses were MCD and class V LN.
Resumo:
Objective. The objective of this study was to conduct a cost-effectiveness analysis of a universal rotavirus vaccination program among children : 5 years of age in Brazil. Methods. Considering a hypothetical annual cohort of approximately 3 300 000 newborns followed over 5 years, a decision-tree model was constructed to examine the possible clinical and economic effects of rotavirus infection with and without routine vaccination of children. Probabilities and unit costs were derived from published research and national administrative data. The impact of different estimates for key parameters was studied using sensitivity analysis. The analysis was conducted from both healthcare system and societal perspectives. Results. The vaccination program was estimated to prevent approximately 1735 351 (54%) of the 3 210 361 cases of rotavirus gastroenteritis and 703 (75%) of 933 rotavirus-associated deaths during the 5-year period. At a vaccine price of 18.6 Brazilian reais (R$) per dose, this program would cost R$121 673 966 and would save R$38 536 514 in direct costs to the public healthcare system and R$71 778 377 in direct and indirect costs to society. The program was estimated to cost R$1 028 and R$1 713 per life-years saved (LYS)from the societal and healthcare system perspectives, respectively. Conclusions. Universal rotavirus vaccination was a cost-effective strategy for both perspectives. However, these findings are highly sensitive to diarrhea incidence rate, proportion of severe cases, vaccine coverage, and vaccine price.
Resumo:
Background: A 150 cm(3) pear-shaped gastric balloon with a 30 cm-long duodenal stem and a 7 g metallic weight at its distal end was designed and developed to facilitate weight loss by (a) delaying gastric emptying thus enhancing interprandial satiety, and (b) stimulating antral and duodenal receptors of satiation. Methods: Twenty-six patients (body mass index of 29 to 40 kg/m(2)) who failed to lose weight despite dietary intervention underwent endoscopic implantation of the balloon device. Patients were monitored for tolerance to the balloon, complications, weight loss, and compliance with a restricted caloric intake. Results: Six men and 20 women with a median body weight of 93.0kg (range, 73.5 to 119.9), median body mass index 34.3 kg/m(2) (range, 28.8 to 39.5) underwent balloon implantation for a median period of 4.0 months (range, 0.75 to 6.0). Twenty-two patients successfully complied with a 1250 to 1500 kcal daily diet restriction during the study period. Median weight reduction was 6.5 kg (range, 3.7 to 19.9). Patients with initial body weight of > 90 kg tended to loose more weight (8.1 kg) than patients weighing < 90 kg (4.5 kg) (P = 0.14). Nine patients with dwell times of 6 months lost 11.5 +/- 4.6 kg. The balloon malfunctioned in 4 patients (in I patient, the balloon leaked spontaneously but remained in the stomach and in 3 patients, the balloon migrated distally). Conclusions: Our novel balloon device may be effective in inducing weight loss by promoting compliance with a restricted caloric intake and is well tolerated due to its small size. Complications resulted from balloon rupture, which can be easily prevented by enhancements in design and use of alternative materials.
Resumo:
Over the past years, component-based software engineering has become an established paradigm in the area of complex software intensive systems. However, many techniques for analyzing these systems for critical properties currently do not make use of the component orientation. In particular, safety analysis of component-based systems is an open field of research. In this chapter we investigate the problems arising and define a set of requirements that apply when adapting the analysis of safety properties to a component-based software engineering process. Based on these requirements some important component-oriented safety evaluation approaches are examined and compared.