943 resultados para Needle squid


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Precursor glass and glass-ceramics with molar composition 2Na2O·1CaO·3SiO2 are studied by infrared, conventional, and microprobe Raman techniques. The Gaussian deconvoluted Raman spectrum of the glass presents bands at 625 and 660 cm-1, attributed to bending vibrations of Si-O-Si bonds, and at 860, 920, 975, and 1030 cm-1, attributed to symmetric stretching vibrations of SiO4 tetrahedra with 4, 3, 2, and 1 nonbridging oxygens, respectively. The Raman microprobe spectrum of a highly crystallized sample presents two narrow and intense bands at about 590 and 980 cm-1, associated with vibrations of SiO4 tetrahedra with two nonbridging oxygens, in agreement with the predicted chain-like structure of crystalline metasilicates. Scanning electron microscopy shows that the crystals distributed in partially crystallized samples have a spherical shape, built up by radially oriented needle-like single crystals. The Raman microprobe spectra of these spherulites show that they still contain residual amorphous material. A comparison of Raman and infrared spectra of amorphous and highly crystallized samples is presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To compare two forms of scheduling clinical dental care for the oral health teams (OHT) included in the strategy of family health, regarding productive aspects of assistance. Methods: Two OHT worked concurrently, using two methods of clinical care: the parameter recommended by the Ministry of Health Ordinance No. 1101, 2002, which establishes 03 dental visits per hour (c/h) per team, and a Testing model, with 02 c/h, being each method applied for a period of 615 hours. The quantitative data was collected in OHTs’ daily production spreadsheets, covering the following items: the number of dental visits (initial, for maintenance and for emergency procedures), procedures performed, consumption of material and sterilization cycles. Data was compared and statistically analyzed through the BioStat 5.0 by applying the paired t-test (p <0.05). Results: Under the Ministerial method and the Testing model, were performed, respectively, 288 and 365 first dental visits, 921 and 686 return dental visits, 167 and 172 emergency dental attendances, with 469 and 110 fouls, 212 and 327 treatments were finished and 2501 and 3046 dental procedures were realized. Among eleven analyzed consumables, five were consumed in smaller quantities in the Testing model: gloves (9%), anesthesia (38%), anesthetic needle (34%), suture material (24%) and aspirators (11%), while the six remaining items presented similar consumption rates between the two models. Conclusions: The testing model revealed to be more productive and economical.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Each year individuals have sought a better quality of life and work, in this case, the science of Bio-insurance needs to keep up with technological advances and the needs of society to minimize or eliminate the risks of accidents. This study evaluated the most common accidents involving health staff from 2007 to 2011 in Araçatuba-SP. 478 accidents were recorded, and 78.7% with percutaneous involvement, 9% with intact skin, 4% with no skin intact, with 7.3 mucous and 1.05% other types of exposures. Most accidents were caused by needles with lumen (68.0%), followed by other agents (14.1%), accidents with blades (8.5%) or needles without lumen (5.5%); 3.7% did not answer and 0.2% were accidents with glasses. When checking the condition in which the accident occurred, 26.0% did not specify, 25.1% occurred in the disposal and / or handling sharp objects, 12.0% at the time of drug administration, 6.9% puncture, 3.7% occurred during recapping the needle. These data show that the most common accidents are those involving needles with lumen and / or sharp objects and due to these factors, the industry of health materials have sought alternatives to minimize such accidents as needles with protective, vacuum collection . Thus, it appears that reporting accidents is important for the development of technical and / or safer materials for patients and health workers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência Odontólogica - FOA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Patologia - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Desenvolvimento Humano e Tecnologias - IBRC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study, clinical, prospective, randomized study was conducted from August 2004 to February 2008 in a convenience sample of 60 women who underwent breast surgery with axillary dissection, divided into two groups (n = 30). The GI (Guidance Kit with different textures, to perform at home) and GII (control). The objective was to analyze the effect of home orientation in patients after surgery for breast cancer complaining of numbness, evaluation, and the conventional esthesiometer. The surface sensitivity was assessed by monofilament Semmes-Weinstein and evaluation using conventional two test tubes with hot water (38 to 43o C) and cold (16 to 27o C), paintbrush, needle. The GI was subjected to 10 sessions and assessments in both 3 times. The M1 (pre intervention), the M2 (post-intervention) after 10 sessions of physical therapy intervention and M3 (washout) after 3 months the second time for assessment. The region targeted for evaluation and intervention was the sensory nerve dermatome intercostobrachial. In the test of Goodman (conventional assessment) there was improvement in both groups, the P1, during the thermal evaluation. The t-test of student (esthesiometer) there was improvement in P2 only in GI (p = 0.003) between points 1 and 2 while the time 3 (p = 0.121 and p = 0.733 respectively). It was concluded that there were divergent and opposite results after examining the effect of home orientation in the nerve dermatome intercostobrachial, evaluation, and the conventional esthesiometer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Primary malignant epithelioid hemangioendothelioma (MEH) of the thyroid is a rare neoplasia with only a few cases reported in the literature. We report a 75 year old man, who presented with a substernal goiter and compressive symptoms. Ultrasonographic evaluation revealed a hypoechogenic nodule in the left lobe, measuring 4.1 cm in maximum diameter, and associated gross calcifications. Fine needle aspiration yielded hemorrhagic material. A left thyroid lobectomy and isthmusectomy was performed. The surgical specimen contained a malignant epithelioid hemangioendothelioma measuring 6 x 4 x 3 cm that had infiltrated about 50% of the thyroidal parenchyma, and surrounded a necrotic nodule. Immunohistochemistry results corroborated the histopathological findings; staining was positive for AE1/AE3, CD31, CD34, factor VIII-related antigen, and Ki-67 expression. Because of the patient’s comorbidities, surgical complementation was not undertaken and he has been undergoing conservative treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil e Ambiental - FEB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the development of an electro-mechanical micro-discharges device operating at ambient condition of pressure and temperature, capable to produce plasma jets for surface finishing. The discharges are produced through a needle shape electrode hollow cathode type by which flows the helium gas. The voltage applied on the electrode is provided for an AC/AC switching voltage converter of full-bridge topology. The converter is energized by a power line of 110/220 VAC, 60 Hz and gives a 1000 V peak-to-peak from 5 kHz to 40 kHz square waveform output. The output frequency is defined by a control signal provided by an external signal generator. The equipment setup includes output acquisition of voltage and current and a photo-detector for photo-electrical measurements, which allows an optical characterization of the plasma jet

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)