959 resultados para METALLIC STENT
Resumo:
Background: A 150 cm(3) pear-shaped gastric balloon with a 30 cm-long duodenal stem and a 7 g metallic weight at its distal end was designed and developed to facilitate weight loss by (a) delaying gastric emptying thus enhancing interprandial satiety, and (b) stimulating antral and duodenal receptors of satiation. Methods: Twenty-six patients (body mass index of 29 to 40 kg/m(2)) who failed to lose weight despite dietary intervention underwent endoscopic implantation of the balloon device. Patients were monitored for tolerance to the balloon, complications, weight loss, and compliance with a restricted caloric intake. Results: Six men and 20 women with a median body weight of 93.0kg (range, 73.5 to 119.9), median body mass index 34.3 kg/m(2) (range, 28.8 to 39.5) underwent balloon implantation for a median period of 4.0 months (range, 0.75 to 6.0). Twenty-two patients successfully complied with a 1250 to 1500 kcal daily diet restriction during the study period. Median weight reduction was 6.5 kg (range, 3.7 to 19.9). Patients with initial body weight of > 90 kg tended to loose more weight (8.1 kg) than patients weighing < 90 kg (4.5 kg) (P = 0.14). Nine patients with dwell times of 6 months lost 11.5 +/- 4.6 kg. The balloon malfunctioned in 4 patients (in I patient, the balloon leaked spontaneously but remained in the stomach and in 3 patients, the balloon migrated distally). Conclusions: Our novel balloon device may be effective in inducing weight loss by promoting compliance with a restricted caloric intake and is well tolerated due to its small size. Complications resulted from balloon rupture, which can be easily prevented by enhancements in design and use of alternative materials.
Resumo:
Objectives: Severe glottic/subglottic stenosis (complex laryngotracheal stenosis) is a rare but challenging complication of endotracheal intubation. Laryngotracheal reconstruction with cartilage graft and an intralaryngeal stent is a procedure described for complex laryngotracheal stenosis management in children; however, for adults, few options remain. Our aim was to analyze the results of laryngotracheal reconstruction as a treatment for complex laryngotracheal stenosis in adults, considering postoperative and long-term outcome. Methods: Laryngotracheal reconstruction (laryngeal split with anterior and posterior interposition of a rib cartilage graft) has been used in our institution to manage glottic/subglottic stenosis restricted to the larynx; laryngotracheal reconstruction associated with cricotracheal resection has been used to treat glottic/subglottic/upper tracheal stenosis (extending beyond the second tracheal ring). A retrospective study was conducted, including all patients with complex laryngotracheal stenosis treated surgically in our institution from January of 2002 until December of 2005. Results: Twenty patients (10 male and 10 female patients; average age, 36.13 years; age range, 18-54 years) were included. There were no deaths, and the postoperative complications were as follows: dysphonia, 25%; subcutaneous emphysema, 10%; tracheocutaneous fistula, 20%; wound infection, 15%; and bleeding, 5.0%. Eighty percent of the patients were completely decannulated after a mean of 23.4 months of follow-up (range, 4 -55 months). Conclusions: Laryngeal split with anterior and posterior cartilage graft interposition as an isolated procedure or associated with a cricotracheal resection is a feasible and low-morbidity alternative for complex laryngotracheal stenosis treatment.
Resumo:
Background. Approximately 20% of urinary tract fistulas after renal allografting are complicated by urinary tract infection, which presents a therapeutic challenge. Objective. To evaluate an option for treatment of urinary tract fistulas associated with urinary tract infection and unsuitable for minimally invasive or primary surgical urinary tract repair. Patients and Methods. The study included 650 recipients who underwent transplantation over 17 years. Urinary leakage was initially treated with indwelling bladder catheterization. Patients with fistulas refractory to treatment underwent surgical intervention to repair the urinary tract. In patients who were not candidates for primary repair of the urinary tract, temporary urinary diversion was performed, rather than classic percutaneous or open nephrostomy, using a ureteral stent (ie, a 6F or 8F Foley catheter with the balloon placed inside the renal pelvis). Results. Overall, urinary leakage occurred in 36 patients (5.5%). Conservative management was successful in 14 vesical fistulas (42.4%) and no ureteral fistulas (0%). Three patients died of sepsis during conservative treatment, before the new surgical approach. Five of 36 urinary leaks (13.9%) were managed using ureteral intubation with an 8F Foley catheter, with a success rate of 80%. Conclusion. Ureteral catheterization with an 8F Foley catheter is a feasible therapeutic option to treat complicated urinary tract fistulas unsuitable for primary surgical repair of the urinary tract.
Resumo:
Background and Aims: Endoscopic ultrasound (EUS) is useful for the treatment of sterile pancreatic fluid collections (PFC), either by means of transmural drainage or by complete aspiration. The aim of this study was to evaluate the efficacy and safety of single-step EUS-guided endoscopic approaches for treatment of sterile PFC. Patients and Methods: During a 3-year period, 77 consecutive patients with symptomatic, persistent sterile PFC were evaluated and treated with the linear EUS. We excluded patients with grossly purulent collections, chronic pseudocyst and those whose cytology diagnostic was neoplastic cyst of pancreas. 44 patients received a single 10-Fr plastic straight stent under EUS or fluoroscopic control (group I) and 33 of these underwent a single-step complete aspiration with a 19-gauge needle (group II). Results: The mean size of the sterile PFC was 48 mm in group I and 28 mm in group II (p < 0.001). Overall, endoscopic treatment was successful in 70 (90.9%) patients. The mean volume aspirated was 25 (18-65) ml. The total number of procedures was 50 in group I and 41 punctures in group II. After a mean follow-up of 64 +/- 15.6 weeks there were 6 complications 13.6%): 2 recurrences (referred to surgery), 2 developing abscesses (submitted a new EUS-guided endoscopic drainage with success), 1 perforation that died (2.2%), and 1 case of bleeding (sent to surgery) in group I. In group II there were only 6 (18.1%) recurrences (submitted a new EUS-guided aspiration). None of the patients undergoing single-step aspiration developed infections, perforation or hemorrhage. Conclusion: The recurrence of pancreatic pseudocysts after endoscopic treatment was similar, either by means of plastic stents or by complete single-step aspiration. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
This study evaluated the arterial response to cobalt-chromium stents with and without polymer coating (Camouflage (R), Hemoteq AG, Wuerselen, Germany) implanted in pigs. Cobalt-chromium balloon-expandable stents (4 x 16 mm) were implanted in the common carotid arteries of nine pigs. Histological analysis of endothelialization, inflammation and injury was performed one month later. All stents were successfully deployed, and all but one animal survived the 30 study days. All arteries were patent. Endothelialization was nearly complete in most sections of all carotid stents in both groups. There were mild inflammatory infiltrate and mild-to-moderate injury, which were associated with the stent shafts and not significantly different between groups. Our findings suggest that, in porcine carotid arteries, the histological response to balloon-expandable cobalt-chromium stents coated with polymer (Camouflage (R), Hemoteq AG) is similar to the response to non-coated cobalt-chromium stents.
Resumo:
Swallowed prostheses have been described in the literature, and in some cases, the diagnosis can be challenging, especially if the partial or complete denture is metal-free. This article presents a case of a swallowed partial denture and points to the importance of early diagnosis. A man was admitted to the emergency room complaining of progressive breathing difficulty while presenting with an extra volume in his neck. After inconclusive image examinations, endoscopy under sedation was used to identify and retrieve the foreign object, which was a metal-free acrylic partial denture. Early diagnosis and the correct treatment can avoid serious sequelae, such as edematous reactions, mucosal infection, and necrosis. Patients should be scheduled for regular recall visits for evaluation of prosthesis fit and retention, condition of the abutments, and nocturnal wear. Int J Prosthodont 2010;23:339-341.
Resumo:
Purpose: Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereo lithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. Materials and Methods: Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. Results: The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. Conclusions: The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:860-865
Resumo:
The clinical success of fiber posts has been attributed to their lower elastic modulus. The tested hypothesis was that fiber posts could lead to lower risk of post debonding and lower risk of root fracture, despite an increase in root stresses. Stress analyses were carried out with a 3D finite element model of a premolar restored with a metallic or a fiber post. Bonded and non-bonded post/cement interface conditions were simulated. We calculated risk-of-fracture indices by determining the highest principal stress values divided by the tensile strength. Shear stresses along the post/cement interface were analyzed for the bonded models. Compared with the premolar restored with a metallic post, the fiber post generated lower stresses along the interface and higher stresses in the root. However, with the fiber post, fracture was less likely to occur in the root, since its core and post fracture indices were higher.
Resumo:
This study evaluated the effect of framework design on the fracture resistance of metal-ceramic implant-supported crowns. Screw-retained molar crowns with a screw access hole composed of metal or porcelain were compared to a cement-retained crown (control). For each group (n = 10), five crowns were subjected to dynamic loading (1,200,000 x 100 N x 2 Hz at 37 degrees C). Afterward, all specimens were loaded to failure using a universal testing machine. Significant differences could be established between the cement-and screw-retained groups (P <= .05), but no difference was found between the screw-retained groups and the specimens subjected to dynamic loading. Occlusal discontinuity of screw-retained crowns affects their resistance, and the metallic support on the screw access hole did not reinforce the crowns. Int J Prosthodont 2010;23:350-352.
Resumo:
Objectives. To evaluate the effects of storage condition (wet or dry) and storage time (24 h and 3 months) on the ultimate tensile strength (UTS) of Single Bond (SB), 3M-ESPE; Opti Bond Solo Plus (OB), Kerr; One Step (OS), Bisco, and Prime & Bond NT (PB), Dentsply adhesive resins. Methods. Hourglass-shaped specimens were obtained from a metallic matrix. Each adhesive was dispensed to fill the molds completely and left undisturbed in a dark chamber for 4 min at 37 degrees C for solvent evaporation. They were individually light-cured for 80 s at 500 mW/cm(2) and randomly divided into three groups: 24 h of water storage; 3 months of water storage; 3 months of dry storage. The specimens were tested in tension at 0.5 mm/min using the microtensile method and data were analyzed by two-way ANOVA and SNK tests for each material. Results. Water storage for 3 months did not cause significant changes in the UTS of any of the adhesives (p-value). Values for water storage ranged from 25.9 MPa for Single Bond at 24 h to 32.7 MPa for Prime & Bond NT after 3 months. Dry storage for 3 months yielded significantly higher UTS for most adhesives, which ranged from approximately 20% for Opti Bond to 160% higher values for Single Bond compared to their 3 months wet storage values. Conclusion. The effects of storage condition and time on the UTS of adhesives were material-dependent. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Non-periodic structural variation has been found in the high T-c cuprates, YBa2Cu3O7-x and Hg0.67Pb0.33Ba2Ca2Cu3O8+delta, by image analysis of high resolution transmission electron microscope (HRTEM) images. We use two methods for analysis of the HRTEM images. The first method is a means for measuring the bending of lattice fringes at twin planes. The second method is a low-pass filter technique which enhances information contained by diffuse-scattered electrons and reveals what appears to be an interference effect between domains of differing lattice parameter in the top and bottom of the thin foil. We believe that these methods of image analysis could be usefully applied to the many thousands of HRTEM images that have been collected by other workers in the high temperature superconductor field. This work provides direct structural evidence for phase separation in high T-c cuprates, and gives support to recent stripes models that have been proposed to explain various angle resolved photoelectron spectroscopy and nuclear magnetic resonance data. We believe that the structural variation is a response to an opening of an electronic solubility gap where holes are not uniformly distributed in the material but are confined to metallic stripes. Optimum doping may occur as a consequence of the diffuse boundaries between stripes which arise from spinodal decomposition. Theoretical ideas about the high T-c cuprates which treat the cuprates as homogeneous may need to be modified in order to take account of this type of structural variation.
Resumo:
Purpose: To test the strength to failure and fracture mode of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments vs cemented standard porcelain-fused-to-metal (PFM) crowns. Materials and Methods: Sixty-four locking taper abutments were randomly allocated to four groups and were cleaned in ethanol in an ultrasonic bath for 5 min. After drying under ambient conditions, the abutments were grit blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n = 16 per group) of Tescera (Bisco), Ceramage (Shofu), and Diamond Crown (DRM) according to the manufacturer`s instructions. The porcelain-fused-to-metal crowns were fabricated by conventional means involving the construction and a wax pattern and casting of a metallic coping followed by sintering of increasing layers of porcelain. All crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1 mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% level of significance was utilized for statistical analysis. Results: The single load to failure (+/- SD) results were: Tescera (1130 +/- 239 N), Ceramage (1099 +/- 257 N), Diamond Crown (1155 +/- 284 N), and PFM (1081 +/- 243 N). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment/metallic coping exposure. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. Conclusion: The three indirect composites and PFM systems fractured at loads higher than those typically associated with normal occlusal function. Although each material had a different composition and handling technique, no significant differences were found concerning their single load to fracture resistance among composite systems and PFM.
Resumo:
Background Long-term success of the implant restorations is based upon the biology and vasculature of the bone surrounding the implants, especially for the bone between two implants. Purpose The aim of this study was to evaluate how loaded implants placed 2 or 3 mm apart influence bone vessel organization. Material and methods Six mongrel dogs were used for the study. The four mandibular premolars were extracted and 3 months later, four 4.5 x 10 mm implants were placed on each side of the mandible. The implants were placed so that two adjacent implants were 2 mm (group 1) or 3 mm (group 2) distant from each other. After 12 weeks, the implants were loaded with provisional prostheses, then metallic crowns were placed 4 weeks later. Both temporary and metallic restorations were made so that the distance between the contact point and the bone crest was 5 mm. The animals were sacrificed after 8 weeks. The hemi-mandibles were removed and prepared for analysis. The interimplant bone vasculature of the two groups was studied using scanning electron microscopic images fractal analysis. The fractal dimension (D(f)) was calculated using the box-counting method. Results The values of the D(f) for the blood vessels were significantly higher (P <.05) in the specimens of the group 2 (1.969 +/- 0.169) than the group 1 (1.556 +/- 0.246). Conclusion The presence of more blood vessels in the group 2 is another indication that 3 mm is a preferable distance for contiguous implants than the 2 mm distance. To cite this article:Traini T, Novaes AB, Piattelli A, Papalexiou V, Muglia VA. The relationship between interimplant distances and vascularization of the interimplant bone.Clin. Oral Impl. Res. 21, 2010; 822-829.doi: 10.1111/j.1600-0501.2010.01926.x.
Resumo:
Objectives The aim of this study was to histomorphometrically evaluate the influence of interimplant distances (ID) and implant placement depth on bone remodeling around contiguous Morse cone connection implants with `platform-shifting` in a dog model. Material and methods Bilateral mandibular premolars of six dogs were extracted, and after 12 weeks, each dog received 8 implants, four placed 1.5 mm subcrestally (SCL) on one side of the mandible and four placed equicrestally (ECL) on the other side, alternating the ID of 2 and 3 mm. The experimental groups were SCL with IDs of 2 mm (2 SCL) and 3 mm (3 SCL) and ECL with IDs of 2 mm (2 ECL) and 3 mm (3 ECL). Metallic crowns were immediately installed. After 8 weeks, the animals were euthanized and histomorphometric analyses were performed to compare bone remodeling in the groups. Results The SCL groups` indices of crestal bone resorption were significantly lower than those of ECL groups. In addition, the vertical bone resorption around the implants was also numerically inferior in the SCL groups, but without statistical significance. No differences were obtained between the different IDs. All the groups presented similar good levels of bone-to-implant contact and histological bone density. Conclusion The subcrestal placement of contiguous Morse cone connection implants with `platform shifting` was more efficient in preserving the interimplant crestal bone. The IDs of 2 and 3 mm did not affect the bone remodeling significantly under the present conditions. To cite this article:Barros RRM, Novaes AB Jr., Muglia VA, Iezzi G, Piattelli A. Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded Morse cone connection implants: a histomorphometric study in dogs.Clin. Oral Impl. Res. 21, 2010; 371-378.doi: 10.1111/j.1600-0501.2009.01860.x.
Resumo:
Fibromuscular dysplasia (FMD) is an important cause of renal artery stenosis, particularly in young females. Polymorphisms of the renin-angiotensin (RA) system have been implicated in the pathogenesis of hypertension and atherosclerotic vascular disease, and may play a role in the development of FMD. Examination of polymorphisms by PCR for angiotensin-converting enzyme (ACE) I/D, angiotensin II type 1 receptor (AT(1)R) A1166C and angiotensinogen (AGT) M235T and T174M was undertaken in 43 patients with typical multifocal renal arterial FMD (MF-FMD) and in 89 controls. The age of NIF-FMD patients at the time of diagnosis of hypertension did not differ (38.6 + 11.1 years vs 35.5 +/- 10.3 years, P = 0.12) from controls and the proportion (95% vs 86%, P = 0.14) of females was similar. Allele frequencies did not differ significantly between groups, except that MF-FMD patients had a significantly higher frequency of the ACE I allele than control subjects (0.62 vs 0.47, P = 0.026). Since the ACE I allele is associated with lower circulating ACE levels and possibly lower tissue levels of angiotensin II (Ang II), and since Ang II modulates vascular smooth muscle cell growth and synthetic activity, the I allele might predispose to defective remodelling of the arterial media, and thus to the development of MF-FMD. This contrasts with atherosclerotic renal artery stenosis, coronary stent restenosis and carotid intimal thickening, which are diseases affecting the arterial intima, and which are associated with increased frequency of the D allele.