926 resultados para Loading
Resumo:
Tese de Doutoramento em Engenharia Química e Biológica.
Resumo:
The potential of salicylic acid (SA) encapsulated in porous materials as drug delivery carriers for cancer treatment was studied. Different porous structures, the microporous zeolite NaY, and the mesoporous SBA-15 and MCM-41 were used as hosts for the anti-inflammatory drug. Characterization with different techniques (FTIR, UV/vis, TGA, 1H NMR, and 13C CPMAS NMR) demonstrated the successful loading of SA into the porous hosts. The mesoporous structures showed to be very efficient to encapsulate the SA molecule. The obtained drug delivery systems (DDS) accommodated 0.74 mmol (341 mg/gZEO) in NaY and 1.07 mmol (493 mg/gZEO) to 1.23 mmol (566 mg/gZEO) for SBA-15 and MCM-41, respectively. Interactions between SA molecules and pore structures were identified. A fast and unrestricted liberation of SA at 10 min of the dissolution assay was achieved with 29.3, 46.6, and 50.1 µg/mL of SA from NaY, SBA-15, and MCM-41, respectively, in the in vitro drug release studies (PBS buffer pH 7.4, 37 °C). Kinetic modeling was used to determine the release patterns of the DDS. The porous structures and DDS were evaluated on Hs578T and MDA-MB-468 breast cancer cell lines viability. The porous structures are nontoxic to cancer cells. Cell viability reduction was only observed after the release of SA from MCM- 41 followed by SBA-15 in both breast cancer cell lines.
Resumo:
Tese de Doutoramento em Biologia das Plantas - MAP BIOPLANT
Resumo:
Dissertação de mestrado integrado em Engenharia Civil
Resumo:
Load-bearing soft tissues such as cartilage, blood vessels and muscles are able to withstand a remarkable compressive stress of several MPa without fracturing. Interestingly, most of these structural tissues are mainly composed of water and in this regard, hydrogels, as highly hydrated 3D-crosslinked polymeric networks, constitute a promising class of materials to repair lesions on these tissues. Although several approaches can be employed to shape the mechanical properties of artificial hydrogels to mimic the ones found on biotissues, critical issues regarding, for instance, their biocompatibility and recoverability after loading are often neglected. Therefore, an innovative hydrogel device made only of chitosan (CHI) was developed for the repair of robust biological tissues. These systems were fabricated through a dual-crosslinking process, comprising a photo- and an ionic-crosslinking step. The obtained CHIbased hydrogels exhibited an outstanding compressive strength of ca. 20 MPa at 95% of strain, which is several orders of magnitude higher than those of the individual components and close to the ones found in native soft tissues. Additionally, both crosslinking processes occur rapidly and under physiological conditions, enabling cellsâ encapsulation as confirmed by high cell survival rates (ca. 80%). Furthermore, in contrast with conventional hydrogels, these networks quickly recover upon unloading and are able to keep their mechanical properties under physiological conditions as result of their non-swell nature.
Resumo:
OBJECTIVE: Anatomical and functional assessment of the heart through Doppler and echocardiography in patients with cell anemia (SCA). METHODS: Twenty-five patients with SCA and ages ranging from 14 to 45 years were prospectively studied in a comparison with 25 healthy volunteers. All of them underwent clinical and laboratory evaluation and Doppler echocardiography as well.The measurements were converted into body surface indices. RESULTS: There were increases in all chamber diameters and left ventricle (LV) mass of the SCA patients. It was characterised an eccentric hypertrophy of the left ventricle. The preload was increased (left ventricle end-diastolic volume) and the afterload was decreased (diastolic blood pressure, peripheral vascular resistance and end-systolic parietal stress ESPS). The cardiac index was increased due to the stroke volume. The ejection fraction and the percentage of the systolic shortening , as well as the systolic time intervals of the LV were equivalent. The isovolumetric contraction period of the LV was increased. The mitral E-septum distance and the end-systolic volume index (ESVi) were increased. The ESPS/ESVi ratio,a loading independent parameter, was decreased in SCA, suggesting systolic dysfunction. No significant differences in the diastolic function or in the pulmonary pressure occurred. CONCLUSION: Chamber dilations, eccentric hypertrophy and systolic dysfunction confirm the evidence of the literature in characterizing a sickle cell anemia cardiomyopathy.
Resumo:
Dissertação de mestrado em Biofísica e Bionanossistemas
Resumo:
Recently, there has been a growing interest in the field of metabolomics, materialized by a remarkable growth in experimental techniques, available data and related biological applications. Indeed, techniques as Nuclear Magnetic Resonance, Gas or Liquid Chromatography, Mass Spectrometry, Infrared and UV-visible spectroscopies have provided extensive datasets that can help in tasks as biological and biomedical discovery, biotechnology and drug development. However, as it happens with other omics data, the analysis of metabolomics datasets provides multiple challenges, both in terms of methodologies and in the development of appropriate computational tools. Indeed, from the available software tools, none addresses the multiplicity of existing techniques and data analysis tasks. In this work, we make available a novel R package, named specmine, which provides a set of methods for metabolomics data analysis, including data loading in different formats, pre-processing, metabolite identification, univariate and multivariate data analysis, machine learning, and feature selection. Importantly, the implemented methods provide adequate support for the analysis of data from diverse experimental techniques, integrating a large set of functions from several R packages in a powerful, yet simple to use environment. The package, already available in CRAN, is accompanied by a web site where users can deposit datasets, scripts and analysis reports to be shared with the community, promoting the efficient sharing of metabolomics data analysis pipelines.
Resumo:
The increase in heavy metal contamination in freshwater systems causes serious environmental problems in most industrialized countries, and the effort to find ecofriendly techniques for reducing water and sediment contamination is fundamental for environmental protection. Permeable barriers made of natural clays can be used as low-cost and eco-friendly materials for adsorbing heavy metals from water solution and thus reducing the sediment contamination. This study discusses the application of permeable barriers made of vermiculite clay for heavy metals remediation at the interface between water and sediments and investigates the possibility to increase their efficiency by loading the vermiculite surface with a microbial biofilm of Pseudomonas putida, which is well known to be a heavy metal accumulator. Some batch assays were performed to verify the uptake capacity of two systems and their adsorption kinetics, and the results indicated that the vermiculite bio-barrier system had a higher removal capacity than the vermiculite barrier (?34.4 and 22.8 % for Cu and Zn, respectively). Moreover, the presence of P. putida biofilm strongly contributed to fasten the kinetics of metals adsorption onto vermiculite sheets. In open-system conditions, the presence of a vermiculite barrier at the interface between water and sediment could reduce the sediment contamination up to 20 and 23 % for Cu and Zn, respectively, highlighting the efficiency of these eco-friendly materials for environmental applications. Nevertheless, the contribution of microbial biofilm in open-system setup should be optimized, and some important considerations about biofilm attachment in a continuous-flow system have been discussed.
Resumo:
The prevalence of obesity is increasing throughout the workforce. Manual lifting tasks are common and can produce significant muscle loading. This study compared muscular activity between obese and non-obese subjects, using surface Electromyography (EMG), during manual lifting. Six different lifting tasks (with 5, 10 and 15 kg loads in free and constrained styles) were performed by 14 participants with different obesity levels. EMG data normalization was based on the percentage of Maximum Contraction during each Task (MCT). Muscle Activation Times (AT) before each task were also evaluated. The study suggests that obesity can increase MCT and delay muscle AT. These findings reinforce the need to develop further studies focused on obesity as a risk factor for the development of musculoskeletal disorders.
Resumo:
Tese de Doutoramento em Engenharia Têxtil
Resumo:
Tese de Doutoramento em Engenharia Mecânica.
Resumo:
Surgeons may use a number of cutting instruments such as osteotomes and chisels to cut bone during an operative procedure. The initial loading of cortical bone during the cutting process results in the formation of microcracks in the vicinity of the cutting zone with main crack propagation to failure occuring with continued loading. When a material cracks, energy is emitted in the form of Acoustic Emission (AE) signals that spread in all directions, therefore, AE transducers can be used to monitor the occurrence and development of microcracking and crack propagation in cortical bone. In this research, number of AE signals (hits) and related parameters including amplitude, duration and absolute energy (abs-energy) were recorded during the indentation cutting process by a wedge blade on cortical bone specimens. The cutting force was also measured to correlate between load-displacement curves and the output from the AE sensor. The results from experiments show AE signals increase substantially during the loading just prior to fracture between 90% and 100% of maximum fracture load. Furthermore, an amplitude threshold value of 64dB (with approximate abs-energy of 1500 aJ) was established to saparate AE signals associated with microcracking (41 – 64dB) from fracture related signals (65 – 98dB). The results also demonstrated that the complete fracture event which had the highest duration value can be distinguished from other growing macrocracks which did not lead to catastrophic fracture. It was observed that the main crack initiation may be detected by capturing a high amplitude signal at a mean load value of 87% of maximum load and unsteady crack propagation may occur just prior to final fracture event at a mean load value of 96% of maximum load. The author concludes that the AE method is useful in understanding the crack initiation and fracture during the indentation cutting process.
Resumo:
L’objectiu de la recerca és definir un marc teòric i metodològic per a l’estudi del canvi tecnològic en Arqueologia. Aquest model posa èmfasi en caracteritzar els compromisos que configuren una tecnologia i avaluar-los en funció dels factors de situació —tècnics, econòmics, polítics, socials i ideològics. S’ha aplicat aquest model a un cas d’estudi concret: la producció d’àmfores romanes durant el canvi d’Era en la província Tarraconensis. L’estudi tecnològic dels envasos s’ha realitzat mitjançant diverses tècniques analítiques: Fluorescència de raigs X (FRX), Difracció de raigs X (DRX), Microscòpia òptica (MO) i Microscòpia electrònica de rastreig (MER). Les dades obtingudes permeten, a més, establir els grups de referència per a cada centre productor d’àmfores i, així, identificar la provinença dels individus recuperats en els centres consumidors. Donat que les àmfores en estudi són artefactes dissenyats específicament per a ser estibats en una nau i servir com a envàs de transport, l’estudi inclou la caracterització de les propietats mecàniques de resistència a la fractura i de tenacitat. En aquest sentit, i per primera vegada, s’ha aplicat l’Anàlisi d’Elements Finits (AEF) per a conèixer el comportament dels diferents dissenys d’àmfora en ésser sotmesos a diverses forces d’ús. L’AEF permet simular per ordinador les activitats en què les àmfores haurien participat durant el seu ús i avaluar-ne el seu comportament tècnic. Els resultats mostren una gran adequació entre les formulacions teòriques i el programa analític implementat per a aquest estudi. Respecte el cas d’estudi, els resultats mostren una gran variabilitat en les eleccions tecnològiques preses pels ceramistes de diferents tallers, però també al llarg del període de funcionament d’un mateix taller. L’aplicació del model ha permès proposar una explicació al canvi de disseny de les àmfores romanes.
Resumo:
En aplicaciones como la conformación en frío, donde los metales duros recubiertos con películas de naturaleza cerámica son ampliamente empleados, la existencia de un contacto mecánico repetitivo induce tensiones Hertzianas y origina el fallo por fatiga. En este trabajo, se investigan diversos recubrimientos cerámicos depositados por deposición física desde fase vapor sobre calidades diferentes de metal duro y un acero rápido pulvimetalúrgico para evaluar sus respectivas respuesta al contacto y comportamiento a fatiga. El trabajo experimental incluye la caracterización de los sistemas mediante ensayos de rayado y nanoindentación y la evaluación de las curvas tensión-deformación de indentación esférica de los sustratos, tanto desnudos como recubiertos, poniendo especial atención en determinar las tensiones de contacto críticas asociadas a la deformación plástica y a la aparición de grietas circulares en la superficie recubierta. A este estudio, le siguen numerosos ensayos a fatiga a cargas inferiores a aquéllas identificadas como críticas bajo carga monotónica y para un número de ciclos comprendido entre 1.000 y 1.000.000 de ciclos. Los resultados experimentales indican que las películas cerámicas no parecen desempeñar un papel relevante en la aparición de la cedencia plástica, siendo la deformación plástica global controlada por la deformación del sustrato. No obstante, para tensiones elevadas de indentación durante el régimen plástico, existe la aparición de grietas circulares en los recubrimientos cerámicos. Además, la aparición de las mismas es sensible a la fatiga por contacto. Este análisis mecánico se complementa con una inspección detallada del daño generado en profundidad y superficie.