902 resultados para Incidental parameter bias


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rationale: Focal onset epileptic seizures are due to abnormal interactions between distributed brain areas. By estimating the cross-correlation matrix of multi-site intra-cerebral EEG recordings (iEEG), one can quantify these interactions. To assess the topology of the underlying functional network, the binary connectivity matrix has to be derived from the cross-correlation matrix by use of a threshold. Classically, a unique threshold is used that constrains the topology [1]. Our method aims to set the threshold in a data-driven way by separating genuine from random cross-correlation. We compare our approach to the fixed threshold method and study the dynamics of the functional topology. Methods: We investigate the iEEG of patients suffering from focal onset seizures who underwent evaluation for the possibility of surgery. The equal-time cross-correlation matrices are evaluated using a sliding time window. We then compare 3 approaches assessing the corresponding binary networks. For each time window: * Our parameter-free method derives from the cross-correlation strength matrix (CCS)[2]. It aims at disentangling genuine from random correlations (due to finite length and varying frequency content of the signals). In practice, a threshold is evaluated for each pair of channels independently, in a data-driven way. * The fixed mean degree (FMD) uses a unique threshold on the whole connectivity matrix so as to ensure a user defined mean degree. * The varying mean degree (VMD) uses the mean degree of the CCS network to set a unique threshold for the entire connectivity matrix. * Finally, the connectivity (c), connectedness (given by k, the number of disconnected sub-networks), mean global and local efficiencies (Eg, El, resp.) are computed from FMD, CCS, VMD, and their corresponding random and lattice networks. Results: Compared to FMD and VMD, CCS networks present: *topologies that are different in terms of c, k, Eg and El. *from the pre-ictal to the ictal and then post-ictal period, topological features time courses that are more stable within a period, and more contrasted from one period to the next. For CCS, pre-ictal connectivity is low, increases to a high level during the seizure, then decreases at offset. k shows a ‘‘U-curve’’ underlining the synchronization of all electrodes during the seizure. Eg and El time courses fluctuate between the corresponding random and lattice networks values in a reproducible manner. Conclusions: The definition of a data-driven threshold provides new insights into the topology of the epileptic functional networks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bisher wurde noch nicht erforscht wie sich die Variation kinematischer Parameter konkret auf den Energiebedarf von Regalbediengeräten auswirkt. Dieser Beitrag untersucht daher die energetischen Folgen bei unterschiedlichen Geschwindigkeiten und Beschleunigungen der Antriebe eines Regalbediengerätes. Veränderte Geschwindigkeiten und Beschleunigungen beeinflussen jedoch auch die Fahr- und Hubzeiten des Regalbediengerätes. Daher wird ebenfalls eine Berechnungsmethode vorgestellt, mit der der optimale Startpunkt des Hubwerkes und die optimale Fahrgeschwindigkeit auf Basis der eingestellten kinematischen Parameter berechnet werden können.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Incidental appendectomy remains a controversial issue. We aimed to collect experience using a modified surgical technique that could be applied securely in infants. METHODS: We performed aseptic intussuscepted incidental appendectomy (AIIA) in three patients using a technique that is thought to assure appendix necrosis along with intact cecal wall. RESULTS: There was no perioperative morbidity due to AIIA in the three patients. In two infants the necrotic appendix was found in the diaper. One infant died secondary to diaphragmatic hernia. Autopsy with histological examination revealed that the cecum was intact along with appendix necrosis. CONCLUSIONS: Modified AIIA could securely be performed in the 3 reported cases. We advocate prospective evaluation of the method.