882 resultados para INFINITE DELAY
Resumo:
Purpose: To investigate the effect of curing rate on softening in ethanol, degree of conversion, and wear of resin composites. Methods: With a given energy density and for each of two different light-curing units (QTH or LED), the curing rate was reduced by modulating the curing mode. Thus, the irradiation of resin composite specimens (Filtek Z250, Tetric Ceram, Esthet-X) was performed in a continuous curing mode and in a pulse-delay curing mode. Wallace hardness was used to determine the softening of resin composite after storage in ethanol. Degree of conversion was determined by infrared spectroscopy (FTIR). Wear was assessed by a three-body test. Data were submitted to Levene`s test, one and three-way ANOVA, and Tukey HSD test (alpha= 0.05). Results: Immersion in ethanol, curing mode, and material all had significant effects on Wallace hardness. After ethanol storage, resin composites exposed to the pulse-delay curing mode were softer than resin composites exposed to continuous cure (P< 0.0001). Tetric Ceram was the softest material followed by Esthet-X and Filtek Z250 (P< 0.001). Only the restorative material had a significant effect on degree of conversion (P< 0.001): Esthet-X had the lowest degree of conversion followed by Filtek Z250 and Tetric Ceram. Curing mode (P= 0.007) and material (P< 0.001) had significant effect on wear. Higher wear resulted from the pulse-delay curing mode when compared to continuous curing, and Filtek Z250 showed the lowest wear followed by Esthet-X and Tetric Ceram. (Am J Dent 2011;24:115-118).
Resumo:
Objective: Congenital bilateral perisylvian syndrome (CBPS) is frequently caused by polymicrogyria (PMG). The aim of this study was to correlate the clinical and psycholinguistic aspects with neuroradiological data of patients with CBPS. Methods: Thirty-one patients were studied. We performed a clinical investigation of the patients and their families, including MRI scanning, neuropsychological tests and language evaluation. Results: The statistical analysis showed that: a) prenatal events are associated with the non-familial type of PMG; b) diffuse PMG is associated with pseudobulbar signs, as opposed to BPPP; c) motor deficit is associated with diffuse PMG; d) epilepsy is equally present in patients with both familial or non-familial PMG, but is more frequently seen in patients with diffuse PMG; e) dyslexia and SLI can be a feature of both the diffuse or BPPP, and either familial or sporadic cases of PMG. Conclusions: The severity of clinical manifestations in CBPS is correlated with the extent of cortical involvement. Most patients with CBPS have a history of speech delay or language difficulties and no epilepsy. Dyslexia can be found in patients with PMG.
Resumo:
Objectives. The purpose of this study was to evaluate how curing protocol affects the extent of polymerization of dual-cured resin cements. Methods. Four commercial resin cements were used (DuoLink, Panavia F 2.0, Variolink II and Enforce). The extent of polymerization of the resin cements cured under different conditions was measured using a (1)H Stray-Field MRI method, which also enabled to probe molecular mobility in the kHz frequency range. Results. Resin cements show well distinct behaviours concerning chemical cure. Immediate photo-activation appears to be the best choice for higher filler loaded resin cements (Panavia F 2.0 and Variolink). A photo-activation delay (5 min) did not induce any significant difference in the extent of polymerization of all cements. Significance. The extent of polymerization of dual-cured resin cements considerably changed among products under various curing protocols. Clinicians should optimize the materials choice taking into account the curing characteristics of the cements. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
The Izergin-Korepin model on a semi-infinite lattice is diagonalized by using the level-one vertex operators of the twisted quantum affine algebra U-q[((2))(2)]. We give the bosonization of the vacuum state with zero particle content. Excitation states are given by the action of the vertex operators on the vacuum state. We derive the boundary S-matrix. We give an integral expression of the correlation functions of the boundary model, and derive the difference equations which they satisfy. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Objectives. The purpose of this study was to investigate the effect of light-curing protocol on degree of conversion (DC), volume contraction (C), elastic modulus (E), and glass transition temperature (T(g)) as measured on a model polymer. It was a further aim to correlate the measured values with each other. Methods. Different light-curing protocols were used in order to investigate the influence of energy density (ED), power density (PD), and mode of cure on the properties. The modes of cure were continuous, pulse-delay, and stepped irradiation. DC was measured by Raman micro-spectroscopy. C was determined by pycnometry and a density column. E was measured by a dynamic mechanical analyzer (DMA), and T(g) was measured by differential scanning calorimetry (DSC). Data were submitted to two-and three-way ANOVA, and linear regression analyses. Results. ED, PD, and mode of cure influenced DC, C, E, and T(g) of the polymer. A significant positive correlation was found between ED and DC (r = 0.58), ED and E (r = 0.51), and ED and T(g) (r = 0.44). Taken together, ED and PD were significantly related to DC and E. The regression coefficient was positive for ED and negative for PD. Significant positive correlations were detected between DC and C (r = 0.54), DC and E (r = 0.61), and DC and T(g) (r = 0.53). Comparisons between continuous and pulse-delay modes of cure showed significant influence of mode of cure: pulse-delay curing resulted in decreased DC, decreased C, and decreased T(g). Influence of mode of cure, when comparing continuous and step modes of cure, was more ambiguous. A complex relationship exists between curing protocol, microstructure of the resin and the investigated properties. The overall performance of a composite is thus indirectly affected by the curing protocol adopted, and the desired reduction of C may be in fact a consequence of the decrease in DC. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objectives: To evaluate the influence of JPEG quality factors 100, 80 and 60 on the reproducibility of identification of cephalometric points on images of lateral cephalograms, compared with the Digital Imaging and Communications in Medicine (DICOM) format. Methods: The sample was composed of 30 images of digital lateral cephalograms obtained from 30 individuals (15 males and 15 females) on a phosphor plate system in DICOM format. The images were converted to JPEG with quality factors 100, 80 and 60 with the aid of software, adding up to 90 images. The 120 images (DICOM, JPEG 100, 80 and 60) were blinded and 12 cephalometric points were identified on each image by three calibrated orthodontists, using the x-y coordinate system, on a cephalometric software. Results: The results revealed that identification of cephalometric points was highly reproducible, except for the point Orbitale (Or) on the x-axis. The different file formats did not present a statistically significant difference. Conclusions: JPEG images of lateral cephalograms with quality factors 100, 80 and 60 did not present alterations in the reproducibility of identification of cephalometric points compared with the DICOM format. Good reproducibility was achieved for the 12 points, except for point Or on the x-axis. Dentomaxillofacial Radiology (2009) 38, 393-400. doi: 10.1259/dmfr/40996636
Resumo:
The diffusion model for percutaneous absorption is developed for the specific case of delivery to the skin being limited by the application of a finite amount of solute. Two cases are considered; in the first, there is an application of a finite donor (vehicle) volume, and in the second, there are solvent-deposited solids and a thin vehicle with a high partition coefficient. In both cases, the potential effect of an interfacial resistance at the stratum corneum surface is also considered. As in the previous paper, which was concerned with the application of a constant donor concentration, clearance limitations due to the viable eqidermis, the in vitro sampling rate, or perfusion rate in vivo are included. Numerical inversion of the Laplace domain solutions was used for simulations of solute flux and cumulative amount absorbed and to model specific examples of percutaneous absorption of solvent-deposited solids. It was concluded that numerical inversions of the Laplace domain solutions for a diffusion model of the percutaneous absorption, using standard scientific software (such as SCIENTIST, MicroMath Scientific software) on modern personal computers, is a practical alternative to computation of infinite series solutions. Limits of the Laplace domain solutions were used to define the moments of the flux-time profiles for finite donor volumes and the slope of the terminal log flux-time profile. The mean transit time could be related to the diffusion time through stratum corneum, viable epidermal, and donor diffusion layer resistances and clearance from the receptor phase. Approximate expressions for the time to reach maximum flux (peak time) and maximum flux were also derived. The model was then validated using reported amount-time and flux-time profiles for finite doses applied to the skin. It was concluded that for very small donor phase volume or for very large stratum corneum-vehicle partitioning coefficients (e.g., for solvent deposited solids), the flux and amount of solute absorbed are affected by receptor conditions to a lesser extent than is obvious for a constant donor constant donor concentrations. (C) 2001 Wiley-Liss, Inc. and the American Pharmaceutical Association J Pharm Sci 90:504-520, 2001.
Resumo:
The effect of adding thickening agents on the penetration of a sunscreen benzophenone-3 through epidermal and a high-density polyethylene membrane was studied using both very thick (infinite dose) and thin tin use) applications. Contradictory results were obtained. Thickening agents retard skin penetration, in a manner consistent with a diffusional resistance in the formulation, when applied as an infinite dose. In contrast, when applied as in thin (in use) doses, thickening agents promote penetration, most likely through greater stratum corneum diffusivity arising from an enhanced hydration by the thicker formulations. The two key implications from this work are (i) a recognition of the danger in the potential extrapolation of infinite dosing to in use situations, and (ii) to recognize that thicker formulations may sometimes enhance the penetration of other topical agents when applied in use.
Resumo:
Antibodies were raised against specific peptides from N-terminal regions of the alpha (1) and alpha (3) isoforms of the GABA(A) receptor, and used to assess the relative expression of these proteins in the superior frontal and primary motor cortices of 10 control, nine uncomplicated alcoholic and six cirrhotic alcoholic cases were matched for age and post-mortem delay. The regression of expression on post-mortem delay was not statistically significant for either isoform in either region. In both cortical areas, the regression of a, expression on age differed significantly between alcoholic cases, which showed a decrease, and normal controls, which did not. Age had no effect on alpha (3) expression. The alpha (1) and alpha (3) isoforms were found to be expressed differentially across cortical regions and showed a tendency to be expressed differentially across case groups. In cirrhotic alcoholics, alpha (1) expression was greater in superior frontal than in motor cortex, whereas this regional difference was not significant in controls or uncomplicated alcoholics. In uncomplicated alcoholics, alpha (3) expression was significantly lower in superior frontal than in motor cortex. Expression of alpha (1) was significantly different from that Of alpha (3) in the superior frontal cortex of alcoholics, but not in controls. In motor cortex, there were no significant differences in expression between the isoforms in any case group.
Resumo:
Objective: premature infants are at increased risk of developmental disability. Early identification of problems allows intervention to ameliorate or attenuate problems. A reliable screening tool allows triage of children in this high-risk population by identifying those unlikely to need full developmental assessment. To explore the test characteristics of an established parent-completed developmental assessment questionnaire 'Ages and Stages Questionnaire' (ASQ) in follow up of an Australian population of premature infants. Methodology: One hundred and sixty-seven children born prematurely with corrected ages 12- to 48-months attending the Growth and Development Clinic at the Mater Children's Hospital in Brisbane, Queensland, Australia; 136 questionnaires 'ASQ' were returned completed (81%) and were compared to formal psychometric assessment (Griffith Mental Development Scales for 12- and 24-months, Bayley Mental Development Intelligence Scale for 18-months, McCarthy General Cognitive Intelligence Scale for 18-months). Developmental delay was considered to be present if any of the above psychometric assessments fell below 1.0 standard deviations (SD). The ASQ cut-off used was 2.0 SD (US data derived means and SD). Results: Aggregate results for all age groups comparing ASQ to psychometric assessments as 'gold standards' found the ASQ to have the following test characteristics: sensitivity (90%); specificity (77%); positive predictive value (40%); negative predictive value (98%): % over-referred (20%); % under-referred (1%); % agreement (79%). likelihood ratio for children failing the ASQ was 3.8 and for passing the ASQ was 0.13. Twenty-one children with known disabilities were included in the study and in 14 of these, the ASQ overall score agreed with the psychometric assessment (67%). Conclusion: The high negative predictive value of the ASQ supports its use as a screening tool for cognitive and motor delays in the follow up of ex-premature infants. This would need to be combined with other strategies as part of a comprehensive follow up program for ex-premature infants.
Resumo:
We consider the statistical properties of the local density of states of a one-dimensional Dirac equation in the presence of various types of disorder with Gaussian white-noise distribution. It is shown how either the replica trick or supersymmetry can be used to calculate exactly all the moments of the local density of states.' Careful attention is paid to how the results change if the local density of states is averaged over atomic length scales. For both the replica trick and supersymmetry the problem is reduced to finding the ground state of a zero-dimensional Hamiltonian which is written solely in terms of a pair of coupled spins which are elements of u(1, 1). This ground state is explicitly found for the particular case of the Dirac equation corresponding to an infinite metallic quantum wire with a single conduction channel. The calculated moments of the local density of states agree with those found previously by Al'tshuler and Prigodin [Sov. Phys. JETP 68 (1989) 198] using a technique based on recursion relations for Feynman diagrams. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
A flow tagging technique based upon ionic fluorescence in strontium is investigated for applications to velocity measurements in gas flows. The method is based upon a combination of two laser based spectroscopic techniques, i.e. resonantly-enhanced ionisation and laser-induced ionic fluorescence. Strontium is first ionised and then planar laser-induced fluorescence is utilised to give 2D 'bright images' of the ionised region of the flow at a given time delay. The results show that this method can be used for velocity measurements. The velocities were measured in two types of air-acetylene flames - a slot burner and a circular burner yielding velocities of 5.1 +/- 0.1 m/s and 9.3 +/- 0.2 m/s, respectively. The feasibility of the method for the determination of velocities in faster flows than those investigated here is discussed.
Resumo:
Teledermatology holds great potential for revolutionizing the delivery of dermatology services, providing equitable service to remote areas and allowing primary care physicians to refer patients to dermatology centres of excellence at a distance. However, before its routine application asa service tool, its reliability, accuracy and cost-effectiveness need to be verified by rigorous evaluation. Teledermatology can be applied in one of two ways: it may be conducted in real-time, utilizing videoconferencing equipment, or by store-and-forward methods, when transmitted digital images or photographs are submitted with a clinical history. While there is a considerable range of reported accuracy and reliability, evidence suggests that teledermatology will become increasingly utilized and incorporated into more conventional dermatology service delivery systems. Studies to date have generally found that real-time dermatology is likely to allow greater clinical information to be obtained from the patient. This may result in fewer patients requiring conventional consultations, but it is generally more time-consuming and costly to the health service provider It is often favoured by the patient because of the instantaneous nature of the diagnosis and management regimen for the condition, and it has educational value to the primary care physician. Store-and-forward systems of teledermatology often give high levels of diagnostic accuracy, and are cheaper and more convenient for the health care provider, but lack the immediacy of patient contact with the dermatologist, and involve a delay in obtaining the diagnosis and advice on management. It is increasingly likely that teledermatology will prove to be a significant tool in the provision of dermatology services in the future. These services will probably be provided by store-and-forward digital image systems, with real-time videoconferencing being used for case conferences and education. However, much more research is needed into the outcomes and Limitations of such a service and its effect on waiting lists, as well as possible cost benefits for patients, primary health care professionals and dermatology departments.
Resumo:
Quantum feedback can stabilize a two-level atom against decoherence (spontaneous emission), putting it into an arbitrary (specified) pure state. This requires perfect homodyne detection of the atomic emission, and instantaneous feedback. Inefficient detection was considered previously by two of us. Here we allow for a non-zero delay time tau in the feedback circuit. Because a two-level atom is a non-linear optical system, an analytical solution is not possible. However, quantum trajectories allow a simple numerical simulation of the resulting non-Markovian process. We find the effect of the time delay to be qualitatively similar to chat of inefficient detection. The solution of the non-Markovian quantum trajectory will not remain fixed, so that the time-averaged state will be mixed, not pure. In the case where one tries to stabilize the atom in the excited state, an approximate analytical solution to the quantum trajectory is possible. The result, that the purity (P = 2Tr[rho (2)] - 1) of the average state is given by P = 1 - 4y tau (where gamma is the spontaneous emission rate) is found to agree very well with the numerical results. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
It is not possible to make measurements of the phase of an optical mode using linear optics without introducing an extra phase uncertainty. This extra phase variance is quite large for heterodyne measurements, however it is possible to reduce it to the theoretical limit of log (n) over bar (4 (n) over bar (2)) using adaptive measurements. These measurements are quite sensitive to experimental inaccuracies, especially time delays and inefficient detectors. Here it is shown that the minimum introduced phase variance when there is a time delay of tau is tau/(8 (n) over bar). This result is verified numerically, showing that the phase variance introduced approaches this limit for most of the adaptive schemes using the best final phase estimate. The main exception is the adaptive mark II scheme with simplified feedback, which is extremely sensitive to time delays. The extra phase variance due to time delays is considered for the mark I case with simplified feedback, verifying the tau /2 result obtained by Wiseman and Killip both by a more rigorous analytic technique and numerically.