956 resultados para Electrical stunning


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study we used a combination of patch clamping and fast confocal Ca2+ imaging to examine the effects of activators of the nitric oxide (NO)/cGMP pathway on pacemaker activity in freshly dispersed ICC from the rabbit urethra, using the amphotericin B perforated patch configuration of the patch-clamp technique. The nitric oxide donor, DEA-NO, the soluble guanylyl cyclase activator YC-1 and the membrane-permeant analogue of cGMP, 8-Br-cGMP inhibited spontaneous transient depolarizations (STDs) and spontaneous transient inward currents (STICs) recorded under current-clamp and voltage-clamp conditions, respectively. Caffeine-evoked Cl- currents were unaltered in the presence of SP-8-Br-PET-cGMPs, suggesting that activation of the cGMP/PKG pathway does not block Cl- channels directly or interfere with Ca2+ release via ryanodine receptors (RyR). However, noradrenaline-evoked Cl- currents were attenuated by SP-8-Br-PET-cGMPs, suggesting that activation of cGMP-dependent protein kinase (PKG) may modulate release of Ca2+ via IP3 receptors (IP3R). When urethral interstitial cells (ICC) were loaded with Fluo4-AM (2 microm), and viewed with a confocal microscope, they fired regular propagating Ca2+ waves, which originated in one or more regions of the cell. Application of DEA-NO or other activators of the cGMP/PKG pathway did not significantly affect the oscillation frequency of these cells, but did significantly reduce their spatial spread. These effects were mimicked by the IP3R blocker, 2-APB (100 microm). These data suggest that NO donors and activators of the cGMP pathway inhibit electrical activity of urethral ICC by reducing the spatial spread of Ca2+ waves, rather than decreasing wave frequency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction : Insulation defects with externalized conductors have been reported in the St. Jude Riata(®) family of defibrillation leads (St. Jude Medical, Sylmar, CA, USA). The objective of the Northern Ireland Riata(®) lead screening program was to identify insulation defects and externalized conductors by systematic fluoroscopic and electrical assessment in a prospectively defined cohort of patients. We sought to estimate the prevalence, identify risk factors, and determine the natural history of this abnormality. Methods : All patients with a Riata(®) lead under follow-up at the Royal Victoria Hospital were invited for fluoroscopic imaging and implantable cardioverter-defibrillator lead parameter checks. Fluoroscopic images were read independently by two cardiologists and the presence of externalized conductors was classified as positive, negative, or borderline. Results: One hundred and sixty-five of 212 patients with a Riata lead were evaluated by fluoroscopy and lead parameter measurements. The mean duration after implantation was 3.98+/-1.43 years. After screening 25 (15%) patients were classified as positive, 137 (83%) negative, and three (1.8%) borderline. Time since implantation (P = 0.001), presence of a single coil lead (P = 0.042), and patient age (P = 0.034) were significantly associated with externalized conductors. The observed rate of externalized conductors was 26.9% for 8-French and 4.7% for 7-French leads. No leads that were identified prospectively with externalized conductors had electrical abnormalities. Seven of 25 (28%) patients had a defective lead extracted by the end of this screening period. Conclusion: A significant proportion (15%) of patients with a Riata lead had an insulation breach 4 years after implantation. High-resolution fluoroscopic imaging in at least two orthogonal views is required to identify this abnormality. (PACE 2012;35:1498-1504).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated and characterized the effect of externally applied electric fields (EF) on retinal pigment epithelial (RPE) cells by exposing primary cultures of human RPE cells (hRPE) and those from the ARPE19 immortalized cell line to various strengths of EF (EF-treated cells) or to no EF (control cells) under different conditions including presence or absence of serum and gelatin and following wounding. We evaluated changes in RPE cell behavior in response to EF by using a computer based image capture and analysis system (Metamorph). We found that RPE cells responded to externally applied EFs by preferential orientation perpendicular to the EF vector, directed migration towards the anode, and faster translocation rate than control, untreated cells. These responses were voltage-dependent. Responses were observed even at low voltages, of 50-300 mV. Furthermore, the migration of hRPE cell sheets generated by wounding of confluent monolayers of cells at early and late confluence could be manipulated by the application of EF, with directed migration towards the anode observed at both sides of the wounded hRPE. In conclusion, RPE cell behaviour can be controlled by an externally applied EF. The potential for externally applied EF to be used as a therapeutic strategy in the management of selected retinal diseases warrants further investigation. © 2010 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:



Email
Print











The accurate measurement of the permittivity, loss tangent and dielectric anisotropy DC bias dependence for two different liquid crystal (LC) materials in the frequency range 140-165 GHz is described. The electrical characteristics are obtained by curve fitting computed transmission coefficients to the experimental spectral response of a new class of electronically reconfigurable frequency selective surface. The periodic structure is designed to yield bandpass filter characteristics with and without an applied bias control voltage in order to measure the tunability of the LC material which is inserted in a 705 µm-thick cavity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The SMART (SensoriMotor Active Rehabilitation Training) Arm is a nonrobotic device designed to allow stroke survivors with severe paresis to practice reaching. It can be used with or without outcome-triggered electrical stimulation (OT-stim) to augment movement. The aim of this study was to evaluate the efficacy of SMART Arm training when used with or without OT-stim, in addition to usual care, as compared with usual care alone during inpatient rehabilitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Variations in the phase angle difference between a remote 11kV connected wind farm and the centre of Belfast during a typical working day are investigated in the paper. The results obtained using phasor measurement units (PMUs) are compared with the data generated using a PSS/E simulator configured to model the N.Ireland network. The study investigates the effect of changes in the load demand and the wind farm output power on the phase angles at various locations on the network. The paper finally describes how a major system disturbance on the All-Ireland network was monitored and analysed using PMUs located at Queen's University, Belfast and University College Dublin. ©2007 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study monitors both the short- and long-term hydration characteristics of concrete using discretized conductivity measurements from initial gauging, through setting and hardening, the latter comprising both the curing and post-curing periods. In particular, attention is directed to the near-surface concrete as it is this zone which protects the steel from the external environment and has a major influence on durability, performance and service-life. A wide range of concrete mixes is studied comprising both plain Portland cement concretes and concretes containing fly-ash and ground granulated blast furnace slag. The parameter normalised conductivity was used to identify four distinct stages in the hydration process and highlight the influence of supplementary cementitious materials (SCM) on hydration and hydration kinetics. A relationship has been presented to account for the temporal decrease in conductivity, post 10-days hydration. The testing procedure and methodology presented lend itself to in-situ monitoring of reinforced concrete structures. (c) 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrical conductivity of a series of pyrrolidinium bis(trifluoromethylsulfonyl)imide ionic liquids, functionalized with a nitrile (cyano) group at the end of an alkyl chain attached to the cation, was studied in the temperature range between 173 K and 393 K. The glass formation of the ionic liquids is influenced by the length of the alkyl spacer separating the nitrile function from the pyrrolidinium ring. The electrical conductivity and the viscosity do not show a monotonic dependence on the alkyl spacer length, but rather an odd-even effect. An explanation for this behavior is given, including the potential energy landscape picture for the glass transition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 71 degrees stripe domain patterns of epitaxial BiFeO3 thin films are frequently being explored to achieve new functional properties, dissimilar from the BiFeO3 bulk properties. We show that in-plane switching and out-of-plane switching of these domains behave very differently. In the in-plane configuration the domains are very stable, whereas in the out-of-plane configuration the domains change their size and patterns, depending on the applied switching voltage frequency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herein, we present the formulation and the characterization of novel adiponitrile-based electrolytes as a function of the salt structure, concentration, and temperature for supercapacitor applications using activated carbon based electrode material. To drive this study two salts were selected, namely, the tetraethylammonium tetrafluoroborate and the 1-ethyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide. Prior to determination of their electrochemical performance, formulated electrolytes were first characterized to quantify their thermal, volumetric, and transport properties as a function of temperature and composition. Then, cyclic voltammetry and electrochemical impedance spectroscopy techniques were used to investigate their electrochemical properties as electrolyte for supercapacitor applications in comparison with those reported for the currently used model electrolyte based on the dissolution of 1 mol·dm–3 of tetraethylammonium tetrafluoroborate in acetonitrile. Surprisingly, excellent electrochemical performances were observed by testing adiponitrile-based electrolytes, especially those containing the 1-ethyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide room-temperature molten salt. Differences observed on electrochemical performances between the selected adiponitrile electrolytes based on high-temperature (tetraethylammonium tetrafluoroborate) and the room-temperature (1-ethyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide) molten salts are mainly driven by the salt solubility in adiponitrile, as well as by the charge and the structure of each involved species. Furthermore, in comparison with classical electrolytes, the selected adiponitrile +1-ethyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide solution exhibits almost similar specific capacitances and lower equivalent serial resistance. These results demonstrate in fact that the adiponitrile +1-ethyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide mixture can be used for the formulation of safer electrolytes presenting a very low vapor pressure even at high temperatures to design acetonitrile-free supercapacitor devices with comparable performances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two mechanisms of conduction were identified from temperature dependent (120 K-340 K) DC electrical resistivity measurements of composites of poly(c-caprolactone) (PCL) and multi-walled carbon nanotubes (MWCNTs). Activation of variable range hopping (VRH) occurred at lower temperatures than that for temperature fluctuation induced tunneling (TFIT). Experimental data was in good agreement with the VRH model in contrast to the TFIT model, where broadening of tunnel junctions and increasing electrical resistivity at T > T-g is a consequence of a large difference in the coefficients of thermal expansion of PCL and MWCNTs. A numerical model was developed to explain this behavior accounting for a thermal expansion effect by supposing the large increase in electrical resistivity corresponds to the larger relative deformation due to thermal expansion associated with disintegration of the conductive MWCNT network. MWCNTs had a significant nucleating effect on PCL resulting in increased PCL crystallinity and an electrically insulating layer between MWCNTs. The onset of rheological percolation at similar to 0.18 vol% MWCNTs was clearly evident as storage modulus, G' and complex viscosity, vertical bar eta*vertical bar increased by several orders of magnitude. From Cole-Cole and Van Gurp-Palmen plots, and extraction of crossover points (G(c)) from overlaying plots of G' and G '' as a function of frequency, the onset of rheological percolation at 0.18 vol% MWCNTs was confirmed, a similar MWCNT loading to that determined for electrical percolation.