999 resultados para Eficiência energética em sistemas computacionais
Resumo:
This master thesis introduces assessment procedures of daylighting performance in office rooms with shaded opening, recommendations for Natal-RN (Latitude 05,47' S, Longitude 35,11' W). The studies assume the need of window exterior shading in hot and humid climate buildings. The daylighting performance analyses are based on simulated results for three levels of illuminance (300,500 e 1000 lux) between 08h00 e 16h00, in rooms with 2,80 m height, 6 m large and 4 m, 6 m e 8 m depths, with a centered single opening, window wall ratio (20%, 40% e 60%), four orientations (North, East, South and West), and two types of sky (clear and partially cloudy). The sky characteristics were statistically determined based on hourly data from INPE-CRN solar and daylighting weather station. The lighting performance is resulted from dynamic computer simulation of 72 models using Troplux 3.12. The simulation results were assessed using a new parameter to quantify the use of interior daylighting, the useful percentage of daylight (PULN), which corresponds to the time fraction with satisfactory light, in accordance with the illuminance design. The passive zone depths are defined based on the PULN. Despite the failures of illuminance data from the weather station, the analyses ratified the high potential of daylighting for shaded rooms. The most influential variables on the lighting performance are the opening size and the illuminance of design, while the orientation is a little influential
Resumo:
This thesis describes the theoretical, methodological and programmatic proposal for a multifamily residential building located in the urban expansion area of Parnamirim/RN, inserted in the program Minha Casa Minha Vida and level of energy efficiency "A", as the RegulamentoTécnico de Qualidade (RTQ-R/INMETRO) for residential buildings. The development project initially consists of procedures as the study of theoretical, architectural programming and cases studies. With the delimitation of a field solution, situated between the reference and the context, proposals are studied to determine the solution and architectural detailing of the proposal. The architectural program was built based on the method of Problem Seeking (Peña and Parshall, 2001) and research has highlighted aspects of reducing the environmental impact and of the program Minha Casa Minha Vida , among others. The design process was characterized by the incorporation of aspects reviewed and programmed, seeking them compatible and have an economically viable building, socio-spatial quality and energy efficient. The results show that it is possible to obtain a building that meets the constraints of the program that provides housing and energy efficiency level A - and many other environmental qualities and constructive, particularly through architectural design
Resumo:
The purpose of this dissertation is the architectural project of the ambulatory complex of the Federal University of Pará in Belém. It is a health care establishment whose focus is sustainability, energy efficiency and humanization. This design went through the application of architectural concepts, the study of references (theorical and empirical ones), planning, examining the terrain and its conditions and the preliminay design and resulted in a preliminary architecture blueprint. The empirical research is based on the main building of the Hospital Universitário João de Barros Barreto in Belém, Hospital Sarah Kubitschek of Fortaleza (Architect João Filgueiras de Lima - Lelé) and Hospital e Maternity São Luiz of São Paulo (Architect Siegbert Zanettini). Part of the planning is based on the method "Problem Seeking of Pena and Parshal (2001)". During the development process I sought to incorporate sustainability criterias, energy efficiency and humanization. In relation to sustainability the dissertation focuses on the utilization of rainwater for non-potable usage
Resumo:
Nos dias que correm a eficiência energética está na ordem do dia, havendo um esforço significativo para obter-se equipamentos cada vez mais eficientes. Uma parte significativa do consumo global de energia, bem como da emissão de gases nocivos e de efeito de estufa, está associado à climatização, quer doméstica quer industrial. Assim, é importante desenvolver tecnologias mais eficientes neste domínio. O principal objetivo deste trabalho consiste no desenvolvimento de um módulo de interface a uma sonda lambda para monitorização de combustão em caldeiras de biomassa. Este módulo permitirá medir a concentração de oxigénio presente na saída das caldeiras, possibilitando o ajuste dinâmico dos parâmetros de combustão por forma a maximizar o seu rendimento e minimizar a emissão de gases poluentes. O módulo desenvolvido é de baixo custo e apresenta uma interface bastante simples, facilitando a sua incorporação em equipamentos já existentes. Os resultados obtidos revelaram-se consistentes com os valores teóricos fornecidos pelo fabricante da sonda utilizada, podendo assim concluir-se que o trabalho foi realizado com sucesso.
Resumo:
Advances in FPGA technology and higher processing capabilities requirements have pushed to the emerge of All Programmable Systems-on-Chip, which incorporate a hard designed processing system and a programmable logic that enable the development of specialized computer systems for a wide range of practical applications, including data and signal processing, high performance computing, embedded systems, among many others. To give place to an infrastructure that is capable of using the benefits of such a reconfigurable system, the main goal of the thesis is to implement an infrastructure composed of hardware, software and network resources, that incorporates the necessary services for the operation, management and interface of peripherals, that coompose the basic building blocks for the execution of applications. The project will be developed using a chip from the Zynq-7000 All Programmable Systems-on-Chip family.
Resumo:
O cultivo do arroz no RS é fortemente relacionado com recursos hídricos, pois este se faz sob irrigação e durante o beneficiamento, especialmente no caso da parboilização, são necessários volumes consideráveis de água. Em vista disso, os solutos presentes nestas águas permitem estimar o impacto desta cultura e sua industrialização na qualidade do ambiente hídrico no RS. Foi desenvolvida uma rotina analítica para caracterização físico-química das águas da cadeia produtiva do arroz, onde foram analisados nitrogênio total, nitrogênio amoniacal, nitrogênio orgânico, açucares redutores, açucares redutores totais, sólidos totais, sólidos fixos, sólidos voláteis, ácidos voláteis, alcalinidade, pH, nitrato, nitrito e fósforo. Também um método multimicotoxinas foi desenvolvido avaliando a eficiência de cinco sistemas de extração-partição para aflatoxina B1 (AFA B1), aflatoxina B2 (AFA B2), ocratoxina A (OTA), zearalenona (ZEA) e deoxinivalenol (DON). A partição liquido-liquido com clorofórmio foi a mais eficiente recuperando 89; 96; 89; 97 e 72%, respectivamente de cada micotoxina. A comparação entre volumes de solventes, onde o número de etapas envolvidas e o tempo necessário para efetuar a determinação confirmaram a simplicidade, a economia e a rapidez deste sistema de partição a ser adotado para extrair micotoxinas de água da cadeia produtiva de arroz. O método foi aplicado para determinação de micotoxinas em amostras de águas de irrigação e parboilização de arroz de diferentes procedências verificando-se que as últimas aparecem contaminadas com micotoxinas, AFA B1 9,0 ng mL-1 e DON 110 ng mL-1 . Foi realizado também um estudo de migração de micotoxinas AFA B1, OTA, ZEA e DON e outros solutos sob condições de encharcamento (4 e 6 h) em dois níveis de fortificação, durante a parboilização do grão ficando demonstrado que durante o processo ocorria a lixiviação de solutos e micotoxinas para água de encharcamento do arroz.
Resumo:
O artigo apresenta os principais elementos que compõem a questão ambiental na sociedade global, através de sua relação entre economia, meio ambiente e política internacional. A primeira parte expõe o debate ambiental no contexto internacional, enfocando-o a partir dos anos 1960, período em que os problemas ambientais surgem com mais intensidade e com eles os protestos sociais nos países centrais. Os encontros sobre política ambiental internacional foram realizados com mais frequência nos anos setenta como a conferência internacional sobre meio ambiente, a primeira chancelada pela ONU em Estocolmo, 1972. Nas décadas de 1970/1980 as autoridades governamentais reconheceram a urgência na resolução da crise ambiental e passaram a traçar estratégias para a mitigação e contenção da crise. A década de 1990 é marcada pela Conferência Rio 1992, que lançou o desenvolvimento sustentável, o qual recomenda que as gerações presentes devem se reproduzir sem comprometer a capacidade de reprodução das gerações futuras. Os encaminhamentos da terceira conferência internacional sobre meio ambiente (Johanesburgo, 2002) condicionaram a questão ambiental à necessidade da formulação de leis ambientais por parte dos Estados Nacionais e instrumentos económicos de gestão ambiental. Na Rio + 20, o tema central foi a economia verde, que surge como alternativa ao desenvolvimento sustentável e se relaciona a mitigação das mudanças climáticas, produção de baixo carbono, eficiência energética, energia renovável etc. O texto se encerra explanando sobre a questão ambiental internacional na sociedade global.
Resumo:
This document presents GEmSysC, an unified cryptographic API for embedded systems. Software layers implementing this API can be built over existing libraries, allowing embedded software to access cryptographic functions in a consistent way that does not depend on the underlying library. The API complies to good practices for API design and good practices for embedded software development and took its inspiration from other cryptographic libraries and standards. The main inspiration for creating GEmSysC was the CMSIS-RTOS standard, which defines an unified API for embedded software in an implementation-independent way, but targets operating systems instead of cryptographic functions. GEmSysC is made of a generic core and attachable modules, one for each cryptographic algorithm. This document contains the specification of the core of GEmSysC and three of its modules: AES, RSA and SHA-256. GEmSysC was built targeting embedded systems, but this does not restrict its use only in such systems – after all, embedded systems are just very limited computing devices. As a proof of concept, two implementations of GEmSysC were made. One of them was built over wolfSSL, which is an open source library for embedded systems. The other was built over OpenSSL, which is open source and a de facto standard. Unlike wolfSSL, OpenSSL does not specifically target embedded systems. The implementation built over wolfSSL was evaluated in a Cortex- M3 processor with no operating system while the implementation built over OpenSSL was evaluated on a personal computer with Windows 10 operating system. This document displays test results showing GEmSysC to be simpler than other libraries in some aspects. These results have shown that both implementations incur in little overhead in computation time compared to the cryptographic libraries themselves. The overhead of the implementation has been measured for each cryptographic algorithm and is between around 0% and 0.17% for the implementation over wolfSSL and between 0.03% and 1.40% for the one over OpenSSL. This document also presents the memory costs for each implementation.
Resumo:
Hoje em dia a preocupação ambiental e a economia são fatores de sustentabilidade que são tidos em conta em países desenvolvidos, especialmente no seio da União Europeia. Reduzir os consumos de energia é, portanto, um ponto-chave para a redução das emissões de gases com efeito de estufa e aumentar a dependência das energias renováveis. Consequentemente surge então a necessidade de aumentar a eficiência dos equipamentos, em particular no presente caso, equipamentos de refrigeração. Para isso foi adotado pela Comissão Europeia uma rotulagem nos produtos consumidores de energia, em particular na refrigeração, os frigoríficos e congeladores domésticos permitindo informar o consumidor para os equipamentos mais eficientes. Mais recentemente, frigoríficos comerciais e profissionais também terão obrigatoriedade de incluir um rótulo energético na parte externa dos mesmos. Nesses rótulos estão incluídas várias informações técnicas do aparelho representadas de uma forma compreensível e lúdica aos olhos do consumidor mais leigo, entre as quais as classes de eficiência energética. As classes de eficiência energética caracterizam-se pela componente tecnológica dos frigoríficos. Perceber quais os componentes e materiais em particular que promovem uma melhor eficiência, quantificar a sua influência e avaliar os seus custos de integração torna-se assim essencial para toda a cadeia envolvida na produção destes equipamentos. Os fluídos frigorigénios e compressores aparentam ser os que mais exercem influência na eficiência de frigoríficos de baixa potência. Tubos capilares com trocador de calor são uma escolha mais eficiente comparado com o tubo capilar padrão que é utilizado nestes frigoríficos. Por forma a obter informação adicional e relevante do ponto de vista da análise energética realizaram-se simulações para determinação do consumo elétrico anual com recurso ao software Pack Calculation Pro. Entre os fluídos frigorigénios R-134a, R-22 e R-410a, os compressores scroll apresentaram consumos mais reduzidos (no máximo de 16%) do que os compressores alternativos. No caso do amoníaco (R-717) os compressores alternativos consumiram em média 14% menos do que os compressores parafuso. O recurso a velocidade variável em compressores permite reduzir o consumo na ordem dos 25%. Válvulas de expansão eletrónicas trazem reduções no consumo de 1,5% quando comparadas com válvulas de expansão termostáticas em compressores de velocidade variável. O propano (R-290) é um gás que mostra ter um melhor desempenho do que o R-134a e R404a em vários compressores, consumindo 16% menos do que o R-404a. Em função da temperatura exterior, o R-290 também apresentou um bom desempenho consumindo em climas quentes (Belém, Brasil) 24% menos do que o R-404a.
Resumo:
A investigação centra-se na aplicação da Gestão Técnica Centralizada como instrumento para a melhoria da eficiência energética dos edifícios e infraestruturas da Força Aérea Portuguesa e diminuição de pessoal afeto à sua manutenção, tendo por base, dois casos de estudo, o edifício QC12 do Centro de Formação Militar e Técnica da Força Aérea e o ECOTERMOLAB, pertencente ao Instituto de Soldadura e Qualidade. Da análise desenvolvida conclui-se que o funcionamento dos edifícios ECOTERMOLAB e QC12, com controlo por GTC, representam anualmente uma diminuição de consumo energético em 30% e 44% respetivamente e, uma redução de 50% nos recursos humanos afetos à instalação do QC12. Da viabilidade económica obtiveram-se as métricas de Valor Atual Líquido e a Taxa Interna de Rentabilidade positivos e um Período de Recuperação do Investimento, de 11,5 anos para ECOTERMOLAB e 10,7 anos para QC12. Por fim, teceram-se algumas recomendações, dirigidas à Força Aérea Portuguesa, com o intento de melhorar a eficiência energética elétrica e a redução de recursos humanos afetos. Abstract: The research is focused in the application of the Centered Technique Management as an instrument to improve the Portuguese Air Force buildings and infrastructures’ energetic efficiency and to reduce the staff in charge of its maintenance, based on two study cases, QC 12 building in The Air Force Military and Technique Training Center and ECOTERMOLAB, which belongs to Instituto de Soldadura e Qualidade (Quality and Welding Institute). From the analysis, one can conclude that the functioning of the ECOTERMOLAB and QC12 buildings, with GTC control, represents an annual consumption of less 30% and 44% respectively and a 50% reduction in the human resources of the QC 12. From the economical viability, it was possible to get the figures of the Net Present Value and the Internal Rate of Return and a Period of Return on Investment of 11,5 years for ECOTERMOLAB and 10,7 years for QC 12. Finally, some recommendations to the Portuguese Air Force were made, aiming the improvement of the electrical energetic efficiency and a reduction in human resources.
Resumo:
Ao longo dos últimos anos, tem-se verificado grandes mudanças no mercado energético global, sendo os Estados Unidos da América um dos grandes protagonistas. A presente investigação tem como principal objetivo compreender e clarificar o conceito de independência energética/auto-suficiência energética e averiguar a possibilidade e o alcance deste propósito por parte dos Estados Unidos da América, desde a Revolução do Shale. Ao longo desta investigação haverá oportunidade de estudar as políticas energéticas assumidas durante aproximadamente os últimos 40 anos, obter informações sobre a segurança energética dos Estados Unidos, bem como formas de exploração energética americana, política para exportação de energia e impactos geopolíticos. Facilmente se observa ao longo deste trabalho que a auto-suficência não pode ser vista numa perspetiva de criação de condições para o isolacionismo americano mas sim numa perspetiva de instrumentalização e proteção dos seus aliados.
Resumo:
Dissertação de Mestrado para a obtenção do grau de Mestre em Arquitectura, apresentada na Faculdade de Arquitectura da Universidade Técnica de Lisboa.
Resumo:
Standardization and sustainability: these two apparently antagonistic words find the challenge of uniting in a flexible architectonic proposal. This was the idea that motivated the proposal of this assignment, whose appearing is bound up with the necessity of thinking about standardized spaces that attend on functional criterias and environmental sustainability, in reply to an existing real demand. The assignment consists of an architectonic proposal for a flexible standard of a Basic Unit of Health for the bioclimatic zone 7 of RN (UBS RN-7), with emphasis in the environmental sustainability. The project contemplates innumerable involved variables, such as: obedience to the current law of the Health Ministry for the UBSs; formal/aesthetic aspects; criterias of expansiveness of the UBS I for the UBS II; relative aspects to the constructive rationality and, mainly, sustainability aspects. With the intention to unite the variables and, also, glimpsing a proposal that could reach a good functional performance, aesthetic, of environment comfort and energetic efficiency, it was also necessary to consider concepts about the flexibility of the envelopment. The elaboration of the architecture first draft was based on bibliographical research, conceptual studies and references, elaboration of the architectonic program and the draft development for the UBS port I and the UBS port II. To the end, an implantation data sheet for the project is proposed for the UBS standard project, where strategies of thermal isolation, shadowing and thermal inertia are adopted and combined to three possible types of lot, resulting in 24 possibilities of implantation
Resumo:
Dissertação de Mestrado, Engenharia Informática, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2014
Resumo:
Sustainability in buildings, while reducing the impact on the environment, contributes to the promotion of social welfare, to increase the health and productivity of occupants. The search for a way of build that meets the aspirations and development of humanity without, however, represent degradation of the environment, has become the great challenge of contemporary architecture. It is considered that the incorporation of principles that provide a sustainable building with careful choices of design solutions contribute to a better economic and thermal performance of the building, as well as functional and psychological comfort to its users. Based on this general understanding, this paper presents an architecture project aimed to health care whose the solutions adopted follow carefully the relevant legislation and sets his sights on the theme of sustainability. The methodology began with studies on the themes of verification service of deaths, sustainability and those application in construction developed through research in academic studies and analysis of architectural projects, using them like reference for the solutions adopted. Within the project analysis was performed a visit to the verification service of deaths in the city of Palmas in Tocantins, subsidizing information that, plus the relevant legislation, led to functional programming and pre-dimensional of the building to be designed. The result of this programming environments were individual records with information from environmental restrictions, space required for the development of activities, desirable flow and sustainability strategies, that can be considered as the first product of relevance of the professional master's degree. Finally we have outlined the basic design architecture of a Verification Service of Death SVO/RN (in portuguese), whose process of projecting defined as a guiding line of work four points: the use of bioclimatic architecture as the main feature projectual, the use of resources would provide minimal harm to the environment, the use of modulation and structure to the building as a form of rationalization and finally the search for solutions that ensure environmental and psychological comfort to users. Importantly to highlight that, besides owning a rare theme in literature that refers to architectural projects, the whole project was drawn up with foundations in projective criteria that contribute to environmental sustainability, with emphasis on thermal performance, energy efficiency and reuse of rainwater