1000 resultados para Didactic investigation
Resumo:
Depuis deux années et demie, l'équipe de Dahlia participe d'un projet, élaboré par le Dr Ch. Bryois, dont les objectifs principaux d'accueil des premiers séjours et pour une durée moyenne de 15 jours, contredisaient les habitudes institutionnelles. Ses porte-parole nous expliquent comment l'équipe a vécu la mise en place de ce modèle, les problèmes rencontrés, les avancées qu'il a introduites dans sa pratique et son élaboration théorique. L'initiateur de cette unité nous a donné, dans une interview, sa propre interprétation de cette expérience.
Resumo:
We investigated the decayed historical church window glasses of two Catalonian churches, both under Mediterranean climate. Glass surfaces were studied by scanning electron microscopy (SEM), energy dispersive spectrometry (EDS), and X-ray diffraction (XRD). Their chemical composition was determined by avelength-dispersive spectrometry (WDS) microprobe analysis. The biodiversity was investigated by molecular methods: DNA extraction from glass, amplification by PCR targeting the16S rRNA and ITS regions, and fingerprint analyses by denaturing gradient gel electrophoresis (DGGE). Clone libraries containing either PCR fragments of the bacterial 16S rDNA or the fungal ITS regions were screened by DGGE. Clone inserts were sequenced and compared with the EMBL database.
Resumo:
DNA is nowadays swabbed routinely to investigate serious and volume crimes, but research remains scarce when it comes to determining the criteria that may impact the success rate of DNA swabs taken on different surfaces and situations. To investigate these criteria in fully operational conditions, DNA analysis results of 4772 swabs taken by the forensic unit of a police department in Western Switzerland over a 2.5-year period (2012-2014) in volume crime cases were considered. A representative and random sample of 1236 swab analyses was extensively examined and codified, describing several criteria such as whether the swabbing was performed at the scene or in the lab, the zone of the scene where it was performed, the kind of object or surface that was swabbed, whether the target specimen was a touch surface or a biological fluid, and whether the swab targeted a single surface or combined different surfaces. The impact of each criterion and of their combination was assessed in regard to the success rate of DNA analysis, measured through the quality of the resulting profile, and whether the profile resulted in a hit in the national database or not. Results show that some situations - such as swabs taken on door and window handles for instance - have a higher success rate than average swabs. Conversely, other situations lead to a marked decrease in the success rate, which should discourage further analyses of such swabs. Results also confirm that targeting a DNA swab on a single surface is preferable to swabbing different surfaces with the intent to aggregate cells deposited by the offender. Such results assist in predicting the chance that the analysis of a swab taken in a given situation will lead to a positive result. The study could therefore inform an evidence-based approach to decision-making at the crime scene (what to swab or not) and at the triage step (what to analyse or not), contributing thus to save resource and increase the efficiency of forensic science efforts.
Resumo:
A growing body of scientific literature recurrently indicates that crime and forensic intelligence influence how crime scene investigators make decisions in their practices. This study scrutinises further this intelligence-led crime scene examination view. It analyses results obtained from two questionnaires. Data have been collected from nine chiefs of Intelligence Units (IUs) and 73 Crime Scene Examiners (CSEs) working in forensic science units (FSUs) in the French speaking part of Switzerland (six cantonal police agencies). Four salient elements emerged: (1) the actual existence of communication channels between IUs and FSUs across the police agencies under consideration; (2) most CSEs take into account crime intelligence disseminated; (3) a differentiated, but significant use by CSEs in their daily practice of this kind of intelligence; (4) a probable deep influence of this kind of intelligence on the most concerned CSEs, specially in the selection of the type of material/trace to detect, collect, analyse and exploit. These results contribute to decipher the subtle dialectic articulating crime intelligence and crime scene investigation, and to express further the polymorph role of CSEs, beyond their most recognised input to the justice system. Indeed, they appear to be central, but implicit, stakeholders in intelligence-led style of policing.
Resumo:
This study investigates whether there are differences in profitability of PPI companies based on the growth strategy they have chosen to follow. It is examined whether those companies following organic growth strategy are more profitable than those companies following acquisitive growth strategy. It is also investigated are ones larger than the others, or are ones growing faster than the others. Also, the factors affecting the profitability of acquisitive companies are further examined. The results showed that there actually are differences between the two groups. Organically grown companies were found to be more profitable, smaller and growing slower than acquisitive companies. When it comes to examining only acquisitive companies there could be found factors that better or worsen the profitability of companies. For example targets that the company has bought in developing markets were making them more profitable.
Resumo:
In this diploma work advantages of coherent anti-Stokes Raman scattering spectrometry (CARS) and various methods of the quantitative analysis of substance structure with its help are considered. The basic methods and concepts of the adaptive analysis are adduced. On the basis of these methods the algorithm of automatic measurement of a scattering strip size of a target component in CARS spectrum is developed. The algorithm uses known full spectrum of target substance and compares it with a CARS spectrum. The form of a differential spectrum is used as a feedback to control the accuracy of matching. To exclude the influence of a background in CARS spectra the differential spectrum is analysed by means of its second derivative. The algorithm is checked up on the simulated simple spectra and on the spectra of organic compounds received experimentally.
Resumo:
A hybrid electric vehicle is a fast-growing concept in the field of vehicle industry. Nowadays two global problems make manufactures to develop such systems. These problems are: the growing cost of a fuel and environmental pollution. Also development of controlled electric drive with high control accuracy and reliability allows improving of vehicle drive characteristics. The objective of this Diploma Thesis is to investigate the possibilities of electrical drive application for new principle of parallel hybrid vehicle system. Electric motor calculations, selection of most suitable control system and other calculations are needed. This work is not final work for such topic. Further investigation with more precise calculations, modeling, measurements and cost calculations are needed to answer the question if such system is efficient.
Resumo:
The present work is a part of the large project with purpose to qualify the Flash memory for automotive application using a standardized test and measurement flow. High memory reliability and data retention are the most critical parameters in this application. The current work covers the functional tests and data retention test. The purpose of the data retention test is to obtain the data retention parameters of the designed memory, i.e. the maximum time of information storage at specified conditions without critical charge leakage. For this purpose the charge leakage from the cells, which results in decrease of cells threshold voltage, was measured after a long-time hightemperature treatment at several temperatures. The amount of lost charge for each temperature was used to calculate the Arrhenius constant and activation energy for the discharge process. With this data, the discharge of the cells at different temperatures during long time can be predicted and the probability of data loss after years can be calculated. The memory chips, investigated in this work, were 0.035 μm CMOS Flash memory testchips, designed for further use in the Systems-on-Chips for automotive electronics.
Resumo:
Objective To compare automatic and manual measurements of intima-media complex (IMC) in common carotid, common femoral and right subclavian arteries of HIV-infected patients in relation to a control group, taking into consideration the classical risk factors for atherosclerosis. Materials and Methods The study sample comprised 70 HIV-infected patients and 70 non-HIV-infected controls paired according sex and age. Automatic (gold standard) and manual measurements of IMC were performed in the carotid arteries. Manual measurements were also performed in common femoral and right subclavian arteries. Bland-Altman graphs were utilized in the comparison and the adopted level significance was 5%. Results Intima-media complex alterations were not observed in any of the individuals as the mean automatic measurement in the right common carotid (RCC) artery was considered as the gold standard. As the gold standard was compared with the manual measurements (mean, maximum and minimum), no clinically significant alteration was observed. As the gold standard was compared with other sites, the difference was statistically and clinically significant at the origin of right subclavian artery (RCC: 0.51 mm vs. 0.91 mm) (p < 0.001). Conclusion HIV-infected individuals are not at higher risk for atherosclerosis than the control population.
Resumo:
Thermal processes are widely used in small molecule chemical analysis and metabolomics for derivatization, vaporization, chromatography, and ionization, especially in gas chromatography mass spectrometry (GC/MS). In this study the effect of heating was examined on a set of 64 small molecule standards and, separately, on human plasma metabolite extracts. The samples, either derivatized or underivatized, were heated at three different temperatures (60, 100, and 250 °C) at different exposure times (30 s, 60 s, and 300 s). All the samples were analyzed by liquid chromatography coupled to electrospray ionization mass spectrometry (LC/MS) and the data processed by XCMS Online ( xcmsonline.scripps.edu ). The results showed that heating at an elevated temperature of 100 °C had an appreciable effect on both the underivatized and derivatized molecules, and heating at 250 °C created substantial changes in the profile. For example, over 40% of the molecular peaks were altered in the plasma metabolite analysis after heating (250 °C, 300s) with a significant formation of degradation and transformation products. The analysis of 64 small molecule standards validated the temperature-induced changes observed on the plasma metabolites, where most of the small molecules degraded at elevated temperatures even after minimal exposure times (30 s). For example, tri- and diorganophosphates (e.g., adenosine triphosphate and adenosine diphosphate) were readily degraded into a mono-organophosphate (e.g., adenosine monophosphate) during heating. Nucleosides and nucleotides (e.g., inosine and inosine monophosphate) were also found to be transformed into purine derivatives (e.g., hypoxanthine). A newly formed transformation product, oleoyl ethyl amide, was identified in both the underivatized and derivatized forms of the plasma extracts and small molecule standard mixture, and was likely generated from oleic acid. Overall these analyses show that small molecules and metabolites undergo significant time-sensitive alterations when exposed to elevated temperatures, especially those conditions that mimic sample preparation and analysis in GC/MS experiments.