915 resultados para Computer vision syndrome


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Autism is a chronic pervasive neurodevelopmental disorder characterized by the early onset of social and communicative impairments as well as restricted, ritualized, stereotypic behavior. The endophenotype of autism includes neuropsychological deficits, for instance a lack of "Theory of Mind" and problems recognizing facial affect. In this study, we report the development and evaluation of a computer-based program to teach and test the ability to identify basic facially expressed emotions. 10 adolescent or adult subjects with high-functioning autism or Asperger-syndrome were included in the investigation. A priori the facial affect recognition test had shown good psychometric properties in a normative sample (internal consistency: rtt=.91-.95; retest reliability: rtt=.89-.92). In a prepost design, one half of the sample was randomly assigned to receive computer treatment while the other half of the sample served as control group. The training was conducted for five weeks, consisting of two hours training a week. The trained individuals improved significantly on the affect recognition task, but not on any other measure. Results support the usefulness of the program to teach the detection of facial affect. However, the improvement found is limited to a circumscribed area of social-communicative function and generalization is not ensured.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Polycythemia vera (PV) is a hemopoetic disorder. Apparently, although thrombosis accounts for the majority of morbidity, AION has not been associated with PV so far. PATIENT AND FINDINGS: A 63 y-old woman with PV was hospitalized because of acute liver failure. She also experienced bilateral painless loss of vision. Bilateral, pale optic disc swelling with flame-like hemorrhages, more pronounced in the right eye, constricted visual fields, and relative afferent papillary defect (RAPD) on the right side were present. Computer tomography scan revealed no signs of intraorbital pathology, elevated intracranial pressure or hemorrhages. CLINICAL COURSE: We interpreted the findings as AION associated with the hyperviscosity syndrome. Liver transplantation had to be carried out in the next days. Three weeks later, vision improved slightly, but RAPD persisted, and disc pallor developed in both eyes. The patient died two months later. DISCUSSION: Central retinal artery and vein occlusions have been described as complications of Essential thrombocythemia, but not of PV. We observed a rare case of bilateral neuropathy suggestive of AION. This condition has so far not been associated with PV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tourette Syndrome begins in childhood and is characterized by uncontrollable repetitive actions like neck craning or hopping and noises such as sniffing or chirping. Worst in early adolescence, these tics wax and wane in severity and occur in bouts unpredictably, often drawing unwanted attention from bystanders. Making matters worse, over half of children with Tourette Syndrome also suffer from comorbid, or concurrent, disorders such as attention deficit hyperactivity disorder (ADHD) and obsessive-compulsive disorder (OCD). These disorders introduce anxious thoughts, impulsivity, inattention, and mood variability that further disrupt children with Tourette Syndrome from focusing and performing well at school and home. Thus, deficits in the cognitive control functions of response inhibition, response generation, and working memory have long been ascribed to Tourette Syndrome. Yet, without considering the effect of medication, age, and comorbidity, this is a premature attribution. This study used an infrared eye tracking camera and various computer tasks requiring eye movement responses to evaluate response inhibition, response generation, and working memory in Tourette Syndrome. This study, the first to control for medication, age, and comorbidity, enrolled 39 unmedicated children with Tourette Syndrome and 29 typically developing peers aged 10-16 years who completed reflexive and voluntary eye movement tasks and diagnostic rating scales to assess symptom severities of Tourette Syndrome, ADHD, and OCD. Children with Tourette Syndrome and comorbid ADHD and/or OCD, but not children with Tourette Syndrome only, took longer to respond and made more errors and distracted eye movements compared to typically-developing children, displaying cognitive control deficits. However, increasing symptom severities of Tourette Syndrome, ADHD, and OCD correlated with one another. Thus, cognitive control deficits were not specific to Tourette Syndrome patients with comorbid conditions, but rather increase with increasing tic severity, suggesting that a majority of Tourette Syndrome patients, regardless of a clinical diagnosis of ADHD and/or OCD, have symptoms of cognitive control deficits at some level. Therefore, clinicians should evaluate and counsel all families of children with Tourette Syndrome, with or without currently diagnosed ADHD and/or OCD, about the functional ramifications of comorbid symptoms and that they may wax and wane with tic severity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Section III of the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) lists attenuated psychosis syndrome as a condition for further study. One important question is its prevalence and clinical significance in the general population. Method: Analyses involved 1229 participants (age 16-40 years) from the general population of Canton Bern, Switzerland, enrolled from June 2011 to July 2012. "Symptom," "onset/worsening," "frequency," and "distress/disability" criteria of attenuated psychosis syndrome were assessed using the structured interview for psychosis-risk syndromes. Furthermore, help-seeking, psychosocial functioning, and current nonpsychotic axis I disorders were surveyed. Well-trained psychologists performed assessments using the computer-assisted telephone interviewing technique. Results: The symptom criterion was met by 12.9% of participants, onset/worsening by 1.1%, frequency by 3.8%, and distress/disability by 7.0%. Symptom, frequency, and distress/disability were met by 3.2%. Excluding trait-like attenuated psychotic symptoms (APS) decreased the prevalence to 2.6%, while adding onset/worsening reduced it to 0.3%. APS were associated with functional impairments, current mental disorders, and help-seeking although they were not a reason for help-seeking. These associations were weaker for attenuated psychosis syndrome. Conclusions: At the population level, only 0.3% met current attenuated psychosis syndrome criteria. Particularly, the onset/worsening criterion, originally included to increase the likelihood of progression to psychosis, lowered its prevalence. Because progression is not required for a self-contained syndrome, a revision of the restrictive onset criterion is proposed to avoid the exclusion of 2.3% of persons who experience and are distressed by APS from mental health care. Secondary analyses suggest that a revised syndrome would also possess higher clinical significance than the current syndrome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Large amounts of animal health care data are present in veterinary electronic medical records (EMR) and they present an opportunity for companion animal disease surveillance. Veterinary patient records are largely in free-text without clinical coding or fixed vocabulary. Text-mining, a computer and information technology application, is needed to identify cases of interest and to add structure to the otherwise unstructured data. In this study EMR's were extracted from veterinary management programs of 12 participating veterinary practices and stored in a data warehouse. Using commercially available text-mining software (WordStat™), we developed a categorization dictionary that could be used to automatically classify and extract enteric syndrome cases from the warehoused electronic medical records. The diagnostic accuracy of the text-miner for retrieving cases of enteric syndrome was measured against human reviewers who independently categorized a random sample of 2500 cases as enteric syndrome positive or negative. Compared to the reviewers, the text-miner retrieved cases with enteric signs with a sensitivity of 87.6% (95%CI, 80.4-92.9%) and a specificity of 99.3% (95%CI, 98.9-99.6%). Automatic and accurate detection of enteric syndrome cases provides an opportunity for community surveillance of enteric pathogens in companion animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In retinal surgery, surgeons face difficulties such as indirect visualization of surgical targets, physiological tremor, and lack of tactile feedback, which increase the risk of retinal damage caused by incorrect surgical gestures. In this context, intraocular proximity sensing has the potential to overcome current technical limitations and increase surgical safety. In this paper, we present a system for detecting unintentional collisions between surgical tools and the retina using the visual feedback provided by the opthalmic stereo microscope. Using stereo images, proximity between surgical tools and the retinal surface can be detected when their relative stereo disparity is small. For this purpose, we developed a system comprised of two modules. The first is a module for tracking the surgical tool position on both stereo images. The second is a disparity tracking module for estimating a stereo disparity map of the retinal surface. Both modules were specially tailored for coping with the challenging visualization conditions in retinal surgery. The potential clinical value of the proposed method is demonstrated by extensive testing using a silicon phantom eye and recorded rabbit in vivo data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Patients with downbeat nystagmus syndrome suffer from oscillopsia, which leads to an unstable visual perception and therefore impaired visual acuity. The aim of this study was to use real-time computer-based visual feedback to compensate for the destabilizing slow phase eye movements. METHODS The patients were sitting in front of a computer screen with the head fixed on a chin rest. The eye movements were recorded by an eye tracking system (EyeSeeCam®). We tested the visual acuity with a fixed Landolt C (static) and during real-time feedback driven condition (dynamic) in gaze straight ahead and (20°) sideward gaze. In the dynamic condition, the Landolt C moved according to the slow phase eye velocity of the downbeat nystagmus. The Shapiro-Wilk test was used to test for normal distribution and one-way ANOVA for comparison. RESULTS Ten patients with downbeat nystagmus were included in the study. Median age was 76 years and the median duration of symptoms was 6.3 years (SD +/- 3.1y). The mean slow phase velocity was moderate during gaze straight ahead (1.44°/s, SD +/- 1.18°/s) and increased significantly in sideward gaze (mean left 3.36°/s; right 3.58°/s). In gaze straight ahead, we found no difference between the static and feedback driven condition. In sideward gaze, visual acuity improved in five out of ten subjects during the feedback-driven condition (p = 0.043). CONCLUSIONS This study provides proof of concept that non-invasive real-time computer-based visual feedback compensates for the SPV in DBN. Therefore, real-time visual feedback may be a promising aid for patients suffering from oscillopsia and impaired text reading on screen. Recent technological advances in the area of virtual reality displays might soon render this approach feasible in fully mobile settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Femoroacetabular impingement (FAI) is a dynamic conflict of the hip defined by a pathological, early abutment of the proximal femur onto the acetabulum or pelvis. In the past two decades, FAI has received increasing focus in both research and clinical practice as a cause of hip pain and prearthrotic deformity. Anatomical abnormalities such as an aspherical femoral head (cam-type FAI), a focal or general overgrowth of the acetabulum (pincer-type FAI), a high riding greater or lesser trochanter (extra-articular FAI), or abnormal torsion of the femur have been identified as underlying pathomorphologies. Open and arthroscopic treatment options are available to correct the deformity and to allow impingement-free range of motion. In routine practice, diagnosis and treatment planning of FAI is based on clinical examination and conventional imaging modalities such as standard radiography, magnetic resonance arthrography (MRA), and computed tomography (CT). Modern software tools allow three-dimensional analysis of the hip joint by extracting pelvic landmarks from two-dimensional antero-posterior pelvic radiographs. An object-oriented cross-platform program (Hip2Norm) has been developed and validated to standardize pelvic rotation and tilt on conventional AP pelvis radiographs. It has been shown that Hip2Norm is an accurate, consistent, reliable and reproducible tool for the correction of selected hip parameters on conventional radiographs. In contrast to conventional imaging modalities, which provide only static visualization, novel computer assisted tools have been developed to allow the dynamic analysis of FAI pathomechanics. In this context, a validated, CT-based software package (HipMotion) has been introduced. HipMotion is based on polygonal three-dimensional models of the patient’s pelvis and femur. The software includes simulation methods for range of motion, collision detection and accurate mapping of impingement areas. A preoperative treatment plan can be created by performing a virtual resection of any mapped impingement zones both on the femoral head-neck junction, as well as the acetabular rim using the same three-dimensional models. The following book chapter provides a summarized description of current computer-assisted tools for the diagnosis and treatment planning of FAI highlighting the possibility for both static and dynamic evaluation, reliability and reproducibility, and its applicability to routine clinical use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The emerging use of real-time 3D-based multimedia applications imposes strict quality of service (QoS) requirements on both access and core networks. These requirements and their impact to provide end-to-end 3D videoconferencing services have been studied within the Spanish-funded VISION project, where different scenarios were implemented showing an agile stereoscopic video call that might be offered to the general public in the near future. In view of the requirements, we designed an integrated access and core converged network architecture which provides the requested QoS to end-to-end IP sessions. Novel functional blocks are proposed to control core optical networks, the functionality of the standard ones is redefined, and the signaling improved to better meet the requirements of future multimedia services. An experimental test-bed to assess the feasibility of the solution was also deployed. In such test-bed, set-up and release of end-to-end sessions meeting specific QoS requirements are shown and the impact of QoS degradation in terms of the user perceived quality degradation is quantified. In addition, scalability results show that the proposed signaling architecture is able to cope with large number of requests introducing almost negligible delay.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The conception of IoT (Internet of Things) is accepted as the future tendency of Internet among academia and industry. It will enable people and things to be connected at anytime and anyplace, with anything and anyone. IoT has been proposed to be applied into many areas such as Healthcare, Transportation,Logistics, and Smart environment etc. However, this thesis emphasizes on the home healthcare area as it is the potential healthcare model to solve many problems such as the limited medical resources, the increasing demands for healthcare from elderly and chronic patients which the traditional model is not capable of. A remarkable change in IoT in semantic oriented vision is that vast sensors or devices are involved which could generate enormous data. Methods to manage the data including acquiring, interpreting, processing and storing data need to be implemented. Apart from this, other abilities that IoT is not capable of are concluded, namely, interoperation, context awareness and security & privacy. Context awareness is an emerging technology to manage and take advantage of context to enable any type of system to provide personalized services. The aim of this thesis is to explore ways to facilitate context awareness in IoT. In order to realize this objective, a preliminary research is carried out in this thesis. The most basic premise to realize context awareness is to collect, model, understand, reason and make use of context. A complete literature review for the existing context modelling and context reasoning techniques is conducted. The conclusion is that the ontology-based context modelling and ontology-based context reasoning are the most promising and efficient techniques to manage context. In order to fuse ontology into IoT, a specific ontology-based context awareness framework is proposed for IoT applications. In general, the framework is composed of eight components which are hardware, UI (User Interface), Context modelling, Context fusion, Context reasoning, Context repository, Security unit and Context dissemination. Moreover, on the basis of TOVE (Toronto Virtual Enterprise), a formal ontology developing methodology is proposed and illustrated which consists of four stages: Specification & Conceptualization, Competency Formulation, Implementation and Validation & Documentation. In addition, a home healthcare scenario is elaborated by listing its well-defined functionalities. Aiming at representing this specific scenario, the proposed ontology developing methodology is applied and the ontology-based model is developed in a free and open-source ontology editor called Protégé. Finally, the accuracy and completeness of the proposed ontology are validated to show that this proposed ontology is able to accurately represent the scenario of interest.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the clinical and ophthalmological findings in two infants with neonatal Marfan syndrome (nMFS) and primary trabeculodysgenesis (PT). Fibrillin 1 (FBN1) mutations were confirmed in both cases. Numerous eye anomalies have been recognized in infants with nMFS, but PT has not been reported previously. Our report expands the phenotype of nMFS, and highlights the importance of early and careful ophthalmological assessment of these infants. (C) 2004 Wiley-Liss, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To describe and present the results of a new surgical technique for patients with floppy eyelid syndrome, based on the medial upper eyelid stretching encountered in this condition. Methods: A case series of 24 patients with floppy eyelid syndrome who where found to have symptomatic predominately medial upper eyelid laxity was analyzed. The history, clinical features, histopathology, and outcome were reviewed after patients underwent medial upper eyelid shortening with or without upper eyelid skin reduction as the first surgical procedure. Results: Of the 24 patients, 18 were men (75%) with a mean age at referral of 56 years, having ocular discomfort and conjunctival irritation/papillary conjunctivitis as the main complaints at presentation. Obesity was present in 96% of cases, with lower eyelid laxityl/ectropion (50%) and upper eyelid eyelash ptosis (29%) in conjunction with the upper eyelid laxity. The affected side was related to sleeping habits or recurrent mechanical eyelid trauma. Histologic studies showed a nonspecific inflammatory cell infiltrate and loss of elastin with loose dermal connective tissue. After surgery, complete relief of ocular symptoms and good functional and cosmetic results were present in all cases after 18 months of follow-up. Conclusions: This new surgical approach is based on the presence of predominately medial upper laxity in patients with floppy eyelid syndrome. The excision of this stretched area stabilized the upper eyelid in an anatomic fashion, providing a good and stable long-term result. The possible mechanisms involved in the medial upper eyelid stretching are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Brugada syndrome (BS) is a genetic disease identified by an abnormal electrocardiogram ( ECG) ( mainly abnormal ECGs associated with right bundle branch block and ST-elevation in right precordial leads). BS can lead to increased risk of sudden cardiac death. Experimental studies on human ventricular myocardium with BS have been limited due to difficulties in obtaining data. Thus, the use of computer simulation is an important alternative. Most previous BS simulations were based on animal heart cell models. However, due to species differences, the use of human heart cell models, especially a model with three-dimensional whole-heart anatomical structure, is needed. In this study, we developed a model of the human ventricular action potential (AP) based on refining the ten Tusscher et al (2004 Am. J. Physiol. Heart Circ. Physiol. 286 H1573 - 89) model to incorporate newly available experimental data of some major ionic currents of human ventricular myocytes. These modified channels include the L-type calcium current (ICaL), fast sodium current (I-Na), transient outward potassium current (I-to), rapidly and slowly delayed rectifier potassium currents (I-Kr and I-Ks) and inward rectifier potassium current (I-Ki). Transmural heterogeneity of APs for epicardial, endocardial and mid-myocardial (M) cells was simulated by varying the maximum conductance of IKs and Ito. The modified AP models were then used to simulate the effects of BS on cellular AP and body surface potentials using a three-dimensional dynamic heart - torso model. Our main findings are as follows. (1) BS has little effect on the AP of endocardial or mid-myocardial cells, but has a large impact on the AP of epicardial cells. (2) A likely region of BS with abnormal cell AP is near the right ventricular outflow track, and the resulting ST-segment elevation is located in the median precordium area. These simulation results are consistent with experimental findings reported in the literature. The model can reproduce a variety of electrophysiological behaviors and provides a good basis for understanding the genesis of abnormal ECG under the condition of BS disease.