861 resultados para Clinical assessment
Resumo:
RESUME : Valganciclovir (Valcyte®) is an orally administered ester prodrug of the standard anticytomegalovirus (CMV) drug ganciclovir. This drug enabled an important reduction of the burden of CMV morbidity and mortality in solid organ transplant recipients. Prevention of CMV infection and treatment of CMV disease requires drug administration during many weeks. Oral drug administration is therefore convenient. Valganciclovir has been developed to overcome the poor oral availability of ganciclovir, which limits its concentration exposure after oral administration and thus its efficacy. This prodrug crosses efficiently the intestinal barrier, is then hydrolyzed into ganciclovir, providing exposure similar to intravenous ganciclovir. Valganciclovir is now preferred for the prophylaxis and treatment of CMV infection in solid organ transplant recipients. Nevertheless, adequate dosage adjustment is necessary to optimize its use, avoiding either insufficient or exaggerate exposure related to differences in its pharmacokinetic profile between patients. The main goal of this thesis was to better describe the pharmacokinetic and pharmacodynamic profile of valganciclovir in solid organ transplant recipients, to assess their reproducibility and their predictability, and thus to evaluate the current recommendations for valganciclovir dosage adjustment and the potential contribution of routine therapeutic drug monitoring (TDM) to patients' management. A total of 437 ganciclovir plasma concentration data from 65 transplant patients (41 kidney, 12 lung, 10 heart and 2 liver recipients, 58 under oral valganciclovir prophylaxis, 8 under oral valganciclovir treatment and 2 under intravenous ganciclovir) were measured using a validated chromatographic method (HPLC) developed for this study. The results were analyzed by non-linear mixed effect modeling (NONMEM). A two-compartment model with first-order absorption appropriately described the data. Systemic clearance was markedly influenced by GFR, with further differences between graft types and sex (CL/GFR = 1.7 in kidney, 0.9 in heart and 1.2 in lung and liver recipients) with interpatient variability (CV%) of 26% and interoccasion variability of 12%. Body weight and sex influenced central volume of distribution (V1 = 0.34 l/kg in males and 0.27 l/kg in females) with an interpatient variability of 20%. Residual intrapatient variability was 21 %. No significant drug interaction influenced GCV disposition. VGC prophylactic efficacy and tolerability were good, without detectable dependence on GCV profile. In conclusion, this analysis highlights the importance of thorough adjustment of VGC dosage to renal function and body weight. Considering the good predictability and reproducibility of GCV profile after oral VGC in solid organ transplant recipients, routine TDM does not appear to be clinically indicated. However, GCV plasma measurement may still be helpful in specific clinical situations such as documentation of appropriate exposure in patients with potentially compromised absorption, or lack of response to CMV disease treatment, or under renal replacement therapy. RESUME : Le valganciclovir (Valcyte®) est un promédicament oral du ganciclovir qui est un anti-infectieux de référence contre les infections à cytomegalovirus (CMV). Cet antiviral a permis de réduire les effets délétères de cette infection jusqu'ici responsable d'une importante morbidité et mortalité chez les transplantés d'organe. La prévention et le traitement de l'infection à CMV sont donc nécessaires mais requièrent l'administration d'un agent antiviral sur une longue période. Un médicament administré par voie orale représente donc un avantage évident. Le valganciclovir a été développé dans le but d'améliorer la faible absorption orale du ganciclovir, et donc son efficacité. Cet ester valylique du ganciclovir traverse plus facilement la barrière gastro-intestinale, puis est hydrolysé en ganciclovir dans la circulation sanguine, produisant une exposition comparable à celle d'une perfusion intraveineuse de ganciclovir. De ce fait, le valganciclovir est devenu largement utilisé pour la prophylaxie mais aussi le traitement de l'infection à CMV. Néanmoins une utilisation optimale de ce nouveau médicament nécessite de bonnes connaissances sur son profil pharmacocinétique afin d'établir un schéma de dose adapté pour éviter tant une surexposition qu'une sous-exposition résultant des différences d'élimination entre les patients. Le but de cette thèse a été d'étudier le profil pharmacocinétique et pharmacodynamique du valganciclovir chez les transplantés d'organe ainsi que sa reproductibilité et sa prédictibilité. Il s'agissait d'apprécier de manière critique le schéma actuellement recommandé pour l'adaptation des doses de valganciclovir, mais aussi la contribution éventuelle d'un suivi des concentrations sanguines en routine. Un total de 437 taux sanguins de ganciclovir ont été mesurés, provenant de 65 patients transplantés d'organe (41 rénaux, 12 pulmonaires, 10 cardiaques et 2 hépatiques, 58 sous une prophylaxie orale de valganciclovir, 8 sous un traitement de valganciclovir et 2 sous un traitement intraveineux). Une méthode de chromatographie liquide à haute performance a été développée et validée pour cette étude. Les résultats ont été ensuite analysés par modélisation non linéaire à effets mixtes (NONMEM). Un modèle à deux compartiments avec absorption de premier ordre a permis de décrire les données. La clairance systémique était principalement influencée par le débit de filtration glomérulaire (GFR), avec une différence entre les types de greffe et les sexes (CL/GFR = 1.7 chez les greffés rénaux, 0.9 pour les greffés cardiaques et 1.2 pour le groupe des greffés pulmonaires et hépatiques) avec un variabilité inter-individuelle de 26% (CV%) et une variabilité inter-occasion de 12%. Le poids corporel ainsi que le sexe avaient une influence sur le volume central de distribution (V1 = 0.34 l/kg chez les hommes et 0.27 l/kg chez les femmes) avec une variabilité inter-individuelle de 20%. La variabilité intra-individuelle résiduelle était de 21 %. Aucune interaction médicamenteuse n'a montré d'influence sur le profil du ganciclovir. La prophylaxie avec le valganciclovir s'est révélée efficace et bien tolérée. En conclusion, cette analyse souligne l'importance d'une adaptation de la dose du valganciclovir à la fonction rénale et au poids du patient. Au vu de la bonne reproductibilité et prédictibilité du profil pharmacocinétique du ganciclovir chez les patients transplantés recevant du valganciclovir, un suivi des concentrations sanguines en routine ne semble pas cliniquement indiqué. Néanmoins, la mesure des taux plasmatiques de ganciclovir peut être utile dans certaines situations particulières, comme la vérification d'une exposition appropriée chez des patients susceptibles d'absorption insuffisante, ou ne répondant pas au traitement d'une infection à CMV ou encore sous épuration extra-rénale. RESUME LARGE PUBLIC : Le valganciclovir est un précurseur capable de libérer du ganciclovir, récemment développé pour améliorer la faible absorption orale de ce dernier. Une fois le valganciclovir absorbé, le ganciclovir libéré dans la circulation sanguine devient efficace contre les infections à cytomégalovirus. Ce virus largement répandu est responsable de maladies insidieuses et parfois graves chez les personnes présentant une baisse des défenses immunitaires, comme les greffés d'organe recevant un traitement anti-rejet. Le ganciclovir est administré pendant plusieurs mois consécutifs soit pour prévenir une infection après la transplantation, soit pour traiter une infection déclarée. La facilité d'administration du valganciclovir par voie orale représente un avantage sur une administration du ganciclovir par perfusion, qui nécessite une hospitalisation. Toutefois, la voie orale peut être une source supplémentaire de variabilité chez les patients, avec un impact potentiel sur l'efficacité ou la toxicité du médicament. Le but de cette étude a été - de décrire le devenir de ce médicament dans le corps humain (dont l'étude relève de la discipline de la pharmacocinétique) - de définir les facteurs cliniques pouvant expliquer les différences de concentration sanguine observées entre les patients sous une posologie donnée - d'explorer les relations entre les concentrations du médicament dans le sang et son efficacité ou la survenue d'effets indésirables (dont l'étude relève de la discipline de la pharmacodynamie). Cette étude a nécessité le développement et la validation, d'une méthode d'analyse pour mesurer la concentration sanguine du ganciclovir, puis son application à 437 échantillons provenant de 65 patients transplantés d'organe solide (41 rénaux, 12 pulmonaires, 10 cardiaques et 2 hépatiques) recevant du valganciclovir. Les résultats des mesures effectuées ont été analysés à l'aide d'un outil mathématique afin d'élaborer un modèle du devenir du médicament dans le sang chez chaque patient et à chaque occasion. Cette étude a permis d'évaluer chez des patients recevant le valganciclovir, la vitesse à laquelle l'organisme absorbe, distribue, puis élimine le médicament. La vitesse d'élimination dépendait étroitement de la fonction rénale, du type de greffe et du sexe alors que la distribution dépendait du poids et du sexe du patient. La variabilité non expliquée par ces facteurs cliniques était modérée et vraisemblablement sans conséquence clinique évidente soit sur l'efficacité ou la tolérance, qui se révèlent très satisfaisantes chez les patients de l'étude. Les observations n'ont pas révélé de relation entre les concentrations de médicament et l'efficacité thérapeutique ou la survenue d'effets indésirables, confirmant que les doses relativement faibles utilisées dans notre collectif de patients suffisaient à produire une exposition reproductible à des concentrations adéquates. En conclusion, le profil (et par conséquent l'absorption) du valganciclovir chez les patients transplantés semble bien prédictible après une adaptation de la dose à la fonction rénale et au poids du patient. Un contrôle systématique des concentrations sanguines n'est probablement pas indiqué en routine, mais cette mesure peut présenter un intérêt dans certaines conditions particulières.
Resumo:
BACKGROUND: The Advisa MRI system is designed to safely undergo magnetic resonance imaging (MRI). Its influence on image quality is not well known. OBJECTIVE: To evaluate cardiac magnetic resonance (CMR) image quality and to characterize myocardial contraction patterns by using the Advisa MRI system. METHODS: In this international trial with 35 participating centers, an Advisa MRI system was implanted in 263 patients. Of those, 177 were randomized to the MRI group and 150 underwent MRI scans at the 9-12-week visit. Left ventricular (LV) and right ventricular (RV) cine long-axis steady-state free precession MR images were graded for quality. Signal loss along the implantable pulse generator and leads was measured. The tagging CMR data quality was assessed as the percentage of trackable tagging points on complementary spatial modulation of magnetization acquisitions (n=16) and segmental circumferential fiber shortening was quantified. RESULTS: Of all cine long-axis steady-state free precession acquisitions, 95% of LV and 98% of RV acquisitions were of diagnostic quality, with 84% and 93%, respectively, being of good or excellent quality. Tagging points were trackable from systole into early diastole (360-648 ms after the R-wave) in all segments. During RV pacing, tagging demonstrated a dyssynchronous contraction pattern, which was not observed in nonpaced (n = 4) and right atrial-paced (n = 8) patients. CONCLUSIONS: In the Advisa MRI study, high-quality CMR images for the assessment of cardiac anatomy and function were obtained in most patients with an implantable pacing system. In addition, this study demonstrated the feasibility of acquiring tagging data to study the LV function during pacing.
Resumo:
BACKGROUND: Cytomegalovirus (CMV) disease remains an important problem in solid-organ transplant recipients, with the greatest risk among donor CMV-seropositive, recipient-seronegative (D(+)/R(-)) patients. CMV-specific cell-mediated immunity may be able to predict which patients will develop CMV disease. METHODS: We prospectively included D(+)/R(-) patients who received antiviral prophylaxis. We used the Quantiferon-CMV assay to measure interferon-γ levels following in vitro stimulation with CMV antigens. The test was performed at the end of prophylaxis and 1 and 2 months later. The primary outcome was the incidence of CMV disease at 12 months after transplant. We calculated positive and negative predictive values of the assay for protection from CMV disease. RESULTS: Overall, 28 of 127 (22%) patients developed CMV disease. Of 124 evaluable patients, 31 (25%) had a positive result, 81 (65.3%) had a negative result, and 12 (9.7%) had an indeterminate result (negative mitogen and CMV antigen) with the Quantiferon-CMV assay. At 12 months, patients with a positive result had a subsequent lower incidence of CMV disease than patients with a negative and an indeterminate result (6.4% vs 22.2% vs 58.3%, respectively; P < .001). Positive and negative predictive values of the assay for protection from CMV disease were 0.90 (95% confidence interval [CI], .74-.98) and 0.27 (95% CI, .18-.37), respectively. CONCLUSIONS: This assay may be useful to predict if patients are at low, intermediate, or high risk for the development of subsequent CMV disease after prophylaxis. CLINICAL TRIALS REGISTRATION: NCT00817908.
Resumo:
Aims: To assess the relationship between clinically maternal chorioamnionitis and outcome in preterm very-low-birth weight (VLBW) infants. Methods: An observational case-control study was conducted in the neonatology departments of 12 acute care teaching hospitals in Spain. Between January 2004 and December 2006, all consecutive VLBW (F1500 g) infants who were born to a mother with clinical chorioamnionitis were enrolled. The controls included infants who were born to mothers without chorioamnionitis, matched by gestational age, and immediately born after each index case. At a corrected age of 24 months, a neurological examination and a psychological assessment of the surviving children were performed.Results: Sixty-six of the newborn infants died; therefore, 262 infants from the original sample were available for the study. Follow-up data were obtained at a corrected age of 24 months from a total of 209 children (106 cases and 103 controls, 80% of the original sample size). Seventy children (33.5%) were diagnosed with some type of sequelae. The following conditions were all more prevalent in infants born to mothers with chorioamnionitis in comparison to controls: low development quotient (98.3'12.15 vs. 95.9'15.64; Ps0.497), cerebral palsy (4.9% vs. 10.4%; Ps0.138), seizures (1.0% vs. 3.8%; Ps0.369), and other neurological or sensorial sequelae (32.0% vs. 34.9%; Ps0.611). Conclusions: After controlling for gestational age, the study population demonstrated that the neurological outcomes in infants at a corrected age of 24 months was not worsened by chorioamnionitis.
Resumo:
For the detection and management of osteoporosis and osteoporosis-related fractures, quantitative ultrasound (QUS) is emerging as a relatively low-cost and readily accessible alternative to dual-energy X-ray absorptiometry (DXA) measurement of bone mineral density (BMD) in certain circumstances. The following is a brief, but thorough review of the existing literature with respect to the use of QUS in 6 settings: 1) assessing fragility fracture risk; 2) diagnosing osteoporosis; 3) initiating osteoporosis treatment; 4) monitoring osteoporosis treatment; 5) osteoporosis case finding; and 6) quality assurance and control. Many QUS devices exist that are quite different with respect to the parameters they measure and the strength of empirical evidence supporting their use. In general, heel QUS appears to be most tested and most effective. Overall, some, but not all, heel QUS devices are effective assessing fracture risk in some, but not all, populations, the evidence being strongest for Caucasian females over 55 years old. Otherwise, the evidence is fair with respect to certain devices allowing for the accurate diagnosis of likelihood of osteoporosis, and generally fair to poor in terms of QUS use when initiating or monitoring osteoporosis treatment. A reasonable protocol is proposed herein for case-finding purposes, which relies on a combined assessment of clinical risk factors (CR.F) and heel QUS. Finally, several recommendations are made for quality assurance and control.
Resumo:
The fully human anti-lipopolysaccharide (LPS) immunoglobulin M (IgM) monoclonal antibody panobacumab was developed as an adjunctive immunotherapy for the treatment of O11 serotype Pseudomonas aeruginosa infections. We evaluated the potential clinical efficacy of panobacumab in the treatment of nosocomial pneumonia. We performed a post-hoc analysis of a multicenter phase IIa trial (NCT00851435) designed to prospectively evaluate the safety and pharmacokinetics of panobacumab. Patients treated with panobacumab (n = 17), including 13 patients receiving the full treatment (three doses of 1.2 mg/kg), were compared to 14 patients who did not receive the antibody. Overall, the 17 patients receiving panobacumab were more ill. They were an average of 72 years old [interquartile range (IQR): 64-79] versus an average of 50 years old (IQR: 30-73) (p = 0.024) and had Acute Physiology and Chronic Health Evaluation II (APACHE II) scores of 17 (IQR: 16-22) versus 15 (IQR: 10-19) (p = 0.043). Adjunctive immunotherapy resulted in an improved clinical outcome in the group receiving the full three-course panobacumab treatment, with a resolution rate of 85 % (11/13) versus 64 % (9/14) (p = 0.048). The Kaplan-Meier survival curve showed a statistically significantly shorter time to clinical resolution in this group of patients (8.0 [IQR: 7.0-11.5] versus 18.5 [IQR: 8-30] days in those who did not receive the antibody; p = 0.004). Panobacumab adjunctive immunotherapy may improve clinical outcome in a shorter time if patients receive the full treatment (three doses). These preliminary results suggest that passive immunotherapy targeting LPS may be a complementary strategy for the treatment of nosocomial O11 P. aeruginosa pneumonia.
Resumo:
Real time glycemia is a cornerstone for metabolic research, particularly when performing oral glucose tolerance tests (OGTT) or glucose clamps. From 1965 to 2009, the gold standard device for real time plasma glucose assessment was the Beckman glucose analyzer 2 (Beckman Instruments, Fullerton, CA), which technology couples glucose oxidase enzymatic assay with oxygen sensors. Since its discontinuation in 2009, today's researchers are left with few choices that utilize glucose oxidase technology. The first one is the YSI 2300 (Yellow Springs Instruments Corp., Yellow Springs, OH), known to be as accurate as the Beckman(1). The YSI has been used extensively for clinical research studies and is used to validate other glucose monitoring devices(2). The major drawback of the YSI is that it is relatively slow and requires high maintenance. The Analox GM9 (Analox instruments, London), more recent and faster, is increasingly used in clinical research(3) as well as in basic sciences(4) (e.g. 23 papers in Diabetes or 21 in Diabetologia). This article is protected by copyright. All rights reserved.
Resumo:
Using a large prospective cohort of over 12,000 women, we determined 2 thresholds (high risk and low risk of hip fracture) to use in a 10-yr hip fracture probability model that we had previously described, a model combining the heel stiffness index measured by quantitative ultrasound (QUS) and a set of easily determined clinical risk factors (CRFs). The model identified a higher percentage of women with fractures as high risk than a previously reported risk score that combined QUS and CRF. In addition, it categorized women in a way that was quite consistent with the categorization that occurred using dual X-ray absorptiometry (DXA) and the World Health Organization (WHO) classification system; the 2 methods identified similar percentages of women with and without fractures in each of their 3 categories, but the 2 identified only in part the same women. Nevertheless, combining our composite probability model with DXA in a case findings strategy will likely further improve the detection of women at high risk of fragility hip fracture. We conclude that the currently proposed model may be of some use as an alternative to the WHO classification criteria for osteoporosis, at least when access to DXA is limited.
Resumo:
ABSTRACT: BACKGROUND: Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various populations using conventional x-ray coronary angiography (CXA) as the standard of reference. METHODS: In 33 centers (in US and Europe) 533 patients, eligible for CXA or SPECT, were enrolled in this multivendor trial. SPECT and CXA were performed within 4 weeks before or after CMR in all patients. Prevalence of CAD in the sample was 49% and 515 patients received MR contrast medium. Drop-out rates for CMR and SPECT were 5.6% and 3.7%, respectively (ns). The study was powered for the primary endpoint of non-inferiority of CMR vs SPECT for both, sensitivity and specificity for the detection of CAD (using a single-threshold reading), the results for the primary endpoint were reported elsewhere. In this article secondary endpoints are presented, i.e. the diagnostic performance of CMR versus SPECT in subpopulations such as multi-vessel disease (MVD), in men, in women, and in patients without prior myocardial infarction (MI). For diagnostic performance assessment the area under the receiver-operator-characteristics-curve (AUC) was calculated. Readers were blinded versus clinical data, CXA, and imaging results. RESULTS: The diagnostic performance (= area under ROC = AUC) of CMR was superior to SPECT (p = 0.0004, n = 425) and to gated-SPECT (p = 0.018, n = 253). CMR performed better than SPECT in MVD (p = 0.003 vs all SPECT, p = 0.04 vs gated-SPECT), in men (p = 0.004, n = 313) and in women (p = 0.03, n = 112) as well as in the non-infarct patients (p = 0.005, n = 186 in 1-3 vessel disease and p = 0.015, n = 140 in MVD). CONCLUSION: In this large multicenter, multivendor study the diagnostic performance of perfusion-CMR to detect CAD was superior to perfusion SPECT in the entire population and in sub-groups. Perfusion-CMR can be recommended as an alternative for SPECT imaging. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier: NCT00977093.
Resumo:
To assess religious coping in schizophrenia, we developed and tested a clinical grid, as no validated questionnaire exists for this population. One hundred fifteen outpatients were interviewed. Results obtained by 2 clinicians were compared. Religion was central in the lives of 45% of patients, 60% used religion extensively to cope with their illness. Religion is a multifaceted construct. Principal component analysis elicited 4 factors: subjective dimension, collective dimension, synergy with psychiatric treatment, and ease of talking about religion with psychiatrist. Different associations were found between these factors and psychopathology, substance abuse, and psychosocial adaptation. The high prevalence of spirituality and religious coping clearly indicates the necessity of addressing spirituality in patient care. Our clinical grid is suitable for this purpose. It proved its applicability to a broad diversity of religious beliefs, even pathological ones. Interjudge reliability and construct validity were high and specific training is not required.
Resumo:
B12-vitamiinin puute iäkkäillä: laboratoriodiagnostiikka, yleisyys ja yhteys sairastavuuteen Tausta: B12-vitamiinin puute on yleistä iäkkäillä ja se tulisi todeta riittävän varhaisessa vaiheessa palautumattomien vaurioiden estämiseksi. On epäselvää pitäisikö diagnostiikka kohdistaa tiettyihin riskiryhmiin vai mahdollisesti seuloa valikoimatonta vanhusväestöä. Myöskään yksimielisyyttä laboratoriotutkimusten valinnasta ei ole. Tavoitteet: Tutkimuksen tarkoituksena oli evaluoida uutta HoloTC RIA menetelmää ja tuottaa viitearvot sille, selvittää B12-vitamiinin puutteen yleisyys, yhteys sairastavuuteen ja mahdolliset riskitekijät suomalaisessa vanhusväestössä, arvioida munuaisfunktion vaikusta B12-vitamiinin puutteen laboratoriotutkimuksiin ja näiden perusteella ehdottaa suomalaiseen terveydenhuoltoon sopivaa laboratoriotutkimusstrategiaa. Aineisto ja menetelmät: Liedon iäkkäät -tutkimuksen vanhusaineisto on edustava otos yhden kunnan yli 65-vuotiaasta väestöstä, yhteensä 1260 henkilöä. Tutkittavat kävivät lääkärintarkastuksessa, ja heistä on käytettävissä runsaasti laboratoriotutkimuksia sekä tiedot sairauksista, ruokavaliosta, lääkkeiden ja vitamiinivalmisteiden käytöstä, dementiaseula ja depressiokysely. Viitearvoaineistoa varten kerättiin näytteet 84 vapaaehtoisesta terveestä aikuisesta ja menetelmäevaluaatiota varten 107 sairaalapotilaasta. Tulokset: HoloTC RIA menetelmän toistettavuus oli hyvä manuaalimenetelmäksi. 95%:n viiteväli holotranskobalamiinille oli 37-171 pmol/l. Kaikilla tutkittavilla, joilla oli muilla laboratoriotutkimuksilla osoitettu todennäköinen B12-vitamiinin puute, myös holotranskobalamiini oli viitealueen alarajaa pienempi. Suurentuneella kystatiini C-pitoisuudella osoitettu munuaisten vajaatoiminta korreloi voimakkaasti homokysteiinin (rs=0.53, p<0.001) ja metyylimalonihapon (rs=0.27, p<0.001) pitoisuuksiin, mutta ei kokonais-B12-vitamiinin (rs=- 0.04, p=0.227) tai holotranskobamiinin (rs=-0.01, p=0.817) pitoisuuksiin. Suomalaisessa vanhusväestössä B12-vitamiinin puutteen prevalenssi oli 12%. Kokonais- B12-vitamiinin pitoisuus oli matala (<150 pmol/l) 6%:lla. Miessukupuoli (OR 1.9, 95% CI 1.2-2.9), ikä ≥75 (OR 2.2, 95% CI 1.4-3.4) ja maitotuotteiden välttäminen (OR 2.3, 95% CI 1.2-4.4) lisäsivät B12-vitamiinin puutteen riskiä, mutta anemia (OR 1.3, 95% CI 0.7-2.3) tai makrosytoosi (OR 1.2, 95% CI 0.6-2.7) eivät. Päätelmät: Diagnosoimaton B12-vitamiinin puute on yleistä iäkkäillä, mutta kliinisesti merkityksellistä spesifistä riskiryhmää ei löydy. Koska anemian ja makrosytoosin puuttuminen ei poissulje B12-vitamiinin puutetta ja munuaisten vajaatoiminta heikentää metabolisten merkkiaineiden käyttökelpoisuutta, kokonais-B12-vitamiinia suositellaan ensisijaiseksi laboratoriotutkimukseksi epäiltäessä B12-vitamiinin puutetta ja tarvittaessa varmentavina tutkimuksina käytetään homokysteiiniä ja holotranskobalamiinia.
Resumo:
Objectives: Quantitative ultrasound (QUS) is an attractive method for assessing fracture risk because it is portable, inexpensive, without ionizing radiation, and available in areas of the world where DXA is not readily accessible or affordable. However, the diversity of QUS scanners and variability of fracture outcomes measured in different studies is an important obstacle to widespread utilisation of QUS for fracture risk assessment. We aimed in this review to assess the predictive power of heel QUS for fractures considering different characteristics of the association (QUS parameters and fracture outcomes measured, QUS devices, study populations, and independence from DXA-measured bone density).Materials/Methods : We conducted an inverse-variance randomeffects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound &SOS;, stiffness index &SI;, and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic, and major osteoporotic fractures) were reported based on study questions.Results : 21 studies including 55,164 women and 13,742 men were included with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fractures. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99), and QUI was 1.99 (95% CI 1.49-2.67). Validated devices from different manufacturers predicted fracture risks with a similar performance (meta-regression p-values>0.05 for difference of devices). There was no sign of publication bias among the studies. QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip DXA showed a significant and independent association with fracture risk (RR/SD for BUA =1.34 [95%CI 1.22-1.49]).Conclusions : This study confirms that QUS of the heel using validated devices predicts risk of different fracture outcomes in elderly men and women. Further research and international collaborations are needed for standardisation of QUS parameters across various manufacturers and inclusion of QUS in fracture risk assessment tools. Disclosure of Interest : None declared.
Resumo:
Introduction: The pharmaceutical aspects of drug administration in clinical trials receive poor consideration compared with the important attention devoted to the analytical and mathematical aspects of biological sample exploitation. During PK calculations, many researchers merely use for dose the nominal amount declared, overlooking the noticeable biases that may result in the assessment of PK parameters. The aim of this work was to evaluate the biases related to doses injected of a biosimilar drug in 2 Phase I clinical trials. Patients (or Materials) and Methods: In trial A, 12 healthy volunteers received different doses of a biosimilar of interferon beta-1a by either subcutaneous (SC) or intravenous (IV) injection. The doses were prepared by partially emptying 0.5-mL syringes supplied by the manufacturer (drop count procedure). In trial B, 12 healthy volunteers received 3 different formulations of the drug by IV injection (biosimilar without albumin [HSA], biosimilar with HSA and original brand [Rebif®]) and 2 different formulations as multiple SC injections (biosimilar HSA-free and original brand). In both trials, the actual dose administered was calculated as: D = C·V - losses. The product titer C was assessed by ELISA. The volume administered IV was assessed by weighting. Losses were evaluated by in vitro experiments. Finally, the binding of 125I-interferon to HSA was evaluated by counting the free and HSA complexed molecule fractions separated by gel filtration. Results: Interferon was not significantly adsorbed onto the lines used for its IV administration. In trial A, the titer was very close to the one declared (96 ± 7%). In trial B, it differed significantly (156 ± 10% for biosimilar with/without HSA and 123 ± 5% for original formulation). In trial A, the dose actually administered showed a large variability. The real injected volume could be biased up to 75% compared with the theoretical volume (for the lower dose administered [ie, 0.03 mL]). This was mainly attributed to a partial re-aspiration of the drug solution before withdrawing the syringe needle. A strict procedure was therefore applied in trial B to avoid these inaccuracies. Finally, in trial B, 125I-Interferon beta-1a binding to HSA appeared time dependent and slow, reaching 50% after 16-hour incubation, which is close to steady state reported for the comparator Rebif®. Conclusion: These practical examples (especially biases on actual titer and volume injected) illustrate that actual dose assessment deserves attention to ensure accuracy for estimates of clearance and distribution volume in the scientific literature and for registration purposes, especially for bioequivalence studies.
Resumo:
Tools to predict fracture risk are useful for selecting patients for pharmacological therapy in order to reduce fracture risk and redirect limited healthcare resources to those who are most likely to benefit. FRAX® is a World Health Organization fracture risk assessment algorithm for estimating the 10-year probability of hip fracture and major osteoporotic fracture. Effective application of FRAX® in clinical practice requires a thorough understanding of its limitations as well as its utility. For some patients, FRAX® may underestimate or overestimate fracture risk. In order to address some of the common issues encountered with the use of FRAX® for individual patients, the International Society for Clinical Densitometry (ISCD) and International Osteoporosis Foundation (IOF) assigned task forces to review the medical evidence and make recommendations for optimal use of FRAX® in clinical practice. Among the issues addressed were the use of bone mineral density (BMD) measurements at skeletal sites other than the femoral neck, the use of technologies other than dual-energy X-ray absorptiometry, the use of FRAX® without BMD input, the use of FRAX® to monitor treatment, and the addition of the rate of bone loss as a clinical risk factor for FRAX®. The evidence and recommendations were presented to a panel of experts at the Joint ISCD-IOF FRAX® Position Development Conference, resulting in the development of Joint ISCD-IOF Official Positions addressing FRAX®-related issues.