998 resultados para CASTE DETERMINATION
Resumo:
The voltammetric behaviour of acetophenetidin(A(1)) aminopyrine(A(2)) acetaminophenol(A(3)) and aminophenol(A(4)) was investigated by linear-sweep, differential-pulse, cyclic voltammetry at a glassy carbon electrode. In a medium of 0.1 mol/L NaOH solution, 4 high sensitivity and resolution anodic peaks were obtained. Their peak potentials are about at 0.68 V, 0.51, 0.22 and - 0.06 V( vs. Ag/AgCl). They can be used for direct determination of A(1), A(2),A(3),A(4) in samples respectively. The method is simple and rapid. The mechanism of the electrode reaction was discussed.
Resumo:
Capillary electrophoresis (CE) with end-column electrochemical detection (EC) of sulfadiazine (SDZ) and sulfamethoxazole (SMZ) is described. Under the optimum conditions, SDZ and SMZ were separated satisfactorily, and a highly sensitive and stable response was obtained at a potential of 1.1 V versus Ag/AgCl. Optimized end-column detection provides detection limits as low as 0.1 mu M for both compounds, which corresponds to 0.024 and 0.021 fmol with peak efficiencies of 394000 and 335000 theoretical plates for SDZ arid SMZ, respectively. The calibration graph was linear over three orders of magnitude. The relative standard deviations (n = 12) of peak currents and migration times were 2.3 and 2.7%, and 0.8 and 1.3%, respectively, for the two compounds. The proposed method was applied to the analysis of tablets and human urine samples with satisfactory results.
Resumo:
The curing temperature, pressure, and curing time have significant influence on finished thermosetting composite products. The time of pressure application is one of the most important processing parameters in the manufacture of a thermosetting composite. The determination of the time of pressure application relies on analysis of the viscosity variation of the polymer, associated with curing temperature and curing time. To determine it, the influence of the time of pressure application on the physical properties of epoxy-terminated poly(phenylene ether ketone) (E-PEK)-based continuous carbon fiber composite was studied. It was found that a stepwise temperature cure cycle is more suitable for manufacture of this composite. There are two viscosity valleys, in the case of the E-PEK system, associated with temperature during a stepwise cure cycle. The analysis on the effects of reinforcement fraction and defect content on the composite sheet quality indicates that the width-adjustable second viscosity valley provides a suitable pressing window. The viscosity, ranging from 400 to 1200 Pa . s at the second viscosity valley, is the optimal viscosity range for applying pressure to ensure appropriate resin flow during curing process, which enables one to get a finished composite with optimal fiber volume fraction and low void content. (C) 1997 John Wiley & Sons, Inc.
Resumo:
The king cobra neuotoxin CM-11 is a small protein with 72 amino acid residues. After its complete assignments of H-1-NMR resonance's were obtained using various 2D-NMR technologies, including of DQF-COSY, clean-TOCSY AND NOESY, the secondary structure was analysed by studying the various NOEs extracted from the NOESY spectra and the distribution of chemical shifts. The secondary structure was finally determined by MCD as follows: a triple-strand antiparallel beta sheet with I20-W36, R37-A43 and V53--S59 as its beta strands, a short alpha helix formed by W30-G35 and four turns formed by P7-K10, C14-G17, K50-V53 and D61-N64.
Resumo:
The steady state voltammogram at a microdisk electrode is used to measure the diffusion coefficient and standard heterogeneous rate constant (k(s)) of ferrocene in polyelectrolyte PEG + LiClO4. The k(s) obtained is smaller in polyelectrolyte than in liquid medium. It is proposed that the polymer solvent electron transfer dynamics are affected by the relaxation rates of the ether dipole sites on the polymer chains, which are in turn constrained by the rates of polymer chain segment, or local structure, relaxations. The dependence of k(s) on temperature is observed. The k(s) increases with increasing temperature.
Resumo:
Due to the difference in reactivity of enantiomers with chiral reagents, it was found that in the Fast Atom Bombardment (FAB) mass spectra of enantiomer mixtures of R-alpha-phenylethylamine and S-alpha-phenylethylamine with a chiral reagent S-phosphorsaeure-(1,1'-bi-naphthyl-2,2'-diylester) (BNP acid), the relative abundance of the characteristic ion is linearly related to the composition of the mixture. We have, therefore, proposed a possible method for the determination of the optical purity of enantiomers by mass spectrometry.
Resumo:
A highly dispersed ultramicro palladium-particle modified carbon fiber microdisk array electrode (Pd-CFE) was employed for capillary electrophoresis-electrochemical (CEEC) detection of hydroxylamine (HA). The Pd particles obtained were in the nanometer scale, had a high electrocatalytic activity towards HA and exhibited good reproducibility and stability. A linear relationship between the current and the analyte concentration was found between 5 x 10(-6) and 1 x 10(-3) mol/l of HA with a correlation coefficient of 0.9992. The detection limit was 5 x 10(-8) mol/l. The applicability of the method for the determination of HA in river water and waste water was investigated.
Resumo:
For nearly three decades, organogermanium compounds have become increasingly of interest owing to their extensive physiological and pharmaceutical activity. In this paper, two new high performance ion chromatographic methods for separation and determination of three kinds of organogermanium compounds beta-carboxyethylgermanium sesquioxide (I), beta-(alpha-methyl)-carboxyethylgermanium sesquioxide (II) and d-(beta-carboxyethyl)germanium hydroxide (III) were proposed. A Dionex DX-300 ion chromatograph equipped with a Dionex FED-II pulsed electrochemical detector (conductivity mode), and a Dionex AI-450 chromatography workstation was employed. The separation was achieved by using ion-exchange or ion-exclusion mechanism. The detection limits(S/N=3, expressed as germanium) for the three compounds were all below sub- mu g/mL level. The methods have been applied to the analysis of tonic oral drinks, and the average recoveries for the three compounds range from 95 - 108%. The results obtained were in agreement with those of hydride generation atomic fluorescence spectrometry (HG-AFS).
Resumo:
It is found that in the fast atom bombardment (FAB) mass spectra R-alpha-phenylethylamine and S-alpha-phenylethylamine can be clearly distinguished by S-1,1'-binaphthyl-2, 2'-diylhydrogenphosphate (S-BNP), Mixture of R-alpha-phenylethylamine and S-alpha-phenylethylamine also be tested and the relative abundance of the characteristic ion of mixture is related to the composition of the mixtute. We have therefore proposed a possible method to determine the optical purity of alpha-phenylethylamine.
Resumo:
The contact angles theta of some liquids on ethylene-propylene copolymer-grafted-glycidyl methacrylate (EPM-g-GMA) were measured. The critical surface tensions r(c) of EPM-g-GMA were evaluated by the Zisman Plot (cos theta versus r(L)), Young-Dupre-Good-Girifalco plot (1 + cos theta versus 1/r(L)(0.5)) and log (1 + cos theta) versus log(r(L)) plot. The following results were obtained: the r(c) values varied significantly with the estimation methods. The critical surface tension r(c) decreased with the increase of the degree of grafting of EPM-g-GMA.
Resumo:
Capillary electrophoresis (CE)/electrochemical detection (EC) for the simultaneous determination of hydrazine and isoniazid has been developed. The electrochemical method uses a novel modified electrode dispersed with ultrafine platinum particles on the surface of a 30 mu m carbon fiber microelectrode. The unique characteristic of the Pt-particles modified carbon fiber microelectrode is its excellent stability. The current measurement for hydrazine is more sensitive than that of isoniazid. Selective determination of trace amount of free hydrazine in isoniazid and its formulation can be achieved at applied potential of 0.5 V.
Resumo:
A series of narrow molecular weight distribution fractions of phenolphthalein polyarylether sulfone(PES-C) had been prepared, The <(M) over bar (w)> of these fractions were determined by conventional light scattering method. The [eta] and the Huggins slope constant k' in DMF, CHCl3 and 1,2-dichloroethane were also determined. The Huggins constants are greater than 0.5 in all of these solvents showing a special solubility behavior. The Mark-Houwink equations of PES-C in these solvents at 25 degrees C are [eta] = 2.79 x 10(-2) <(M) over bar (0.615)(w)> (DMF); [eta] = 3.96 x 10(-2) <(M) over bar (0.58)(w)> (CHCl3); [eta] = 7.40 x 10(-2) <(M) over bar (0.52)(w)> (CH2ClCH2Cl).
Resumo:
An electrochemical pretreatment regime for a cylindrical carbon fibre microelectrode was optimized for the determination of aminopyrine (AM) and its metabolite 4-aminoantipyrine (AAN) by capillary electrophoresis (CE)-electrochemical detection (ED). Under optimized conditions, a response of high sensitivity and stability was obtained for AM and AAN at a detection voltage as low as 0.9 V following CE-ED, by which AM and AAN were separated satisfactorily. The calibration graph was linear over three orders of magnitude and the limits of detection for AM and AAN were in the femtomole range.
Resumo:
The electrocatalytic oxidation of NADH by ferrocene derivatives and the influence of complexation with beta-cyclodextrin (beta-CD) were investigated at a microdisk electrode in a buffer solution. The cyclic voltammetric behavior of the ferrocene derivatives on the microdisk electrode was used to determine the electron-transfer rate constant from NADH to the ferricinium species. The heterogeneous rate constants and the diffusion coefficient of ferrocene derivatives were determined with the microdisk electrode. The effect of temperature and pH on the electrocatalytic oxidation of NADH were assessed.
Resumo:
A reversed-phase high-performance liquid chromatographic method with amperometric detection is described for the separation and quantification of uric acid, guanine, hypoxanthine and xanthine. The isocratic separation of a standard mixture of the compounds was achieved in 5 min on a Spherisorb 5 C-18 reversed-phase column, with a mobile phase of NaH2PO4 (300 mmol dm(-3) pH 3.0)-methanol-acetonitrile-tetrahydrofuran (97.8 + 0.5 + 1.5 + 0.2). Uric acid, guanine, hypoxanthine and xanthine were completely separated, with detection limits in the range 2-20 pmol per injection. The effect of pH and the composition of the mobile phase on the separation are described. The hydrodynamic voltammograms of these compounds were recorded at a glassy carbon electrode. The linear range of the calibration graph for each compound was: uric acid; 1-5000 mu mol dm(-3); guanine, 0.5-2000 mu mol dm(-3); hypoxanthine, 0.1-500 mu mol dm(-3) and xanthine, 0.5-5000 mu mol dm(-3). The within- and between-day precision was good. The uric acid and hypoxanthine content in human plasma was measured using the proposed method. Good recoveries of uric acid (97.9-103%), hypoxanthine (98.0-99.2%), guanine (96.0-98.3%) and xanthine (96.0-102%) were obtained from human plasma. The results of electrochemical detection were in good agreement with those of UV detection.