937 resultados para Angular velocity
Resumo:
Since Michel Mayor and his student Didier Queloz s pioneer announcement, in 1995, of the existence of a planet orbiting the star 51 Peg, up to present date, 695 extrasolar planets orbiting stars of spectral type F, G, K and M have been discovered. A study on the behavior of the total angular momentum of the planetary systems known up to present date becomes relevant when we know that about 98% of the angular momentum of the solar system is associated with the planets, although they represent only 0.15 percent of the mass of the whole system. In this dissertation we study the behavior of stellar angular momentum, orbital angular momentum and total angular momentum in a sample of 282 stars harboring planets, including 40 multiple systems. We observed that planetary systems containing more than one known planet have both higher orbital angular momentum and total angular momentum compared to those who have only one planet. This analysis shows that multiplanet systems tend to have higher momenta, suggesting that the planets in such systems that contribute to the greater portion momenta have been found. Thus, planetary systems with lower values for the momenta represent the best candidates to the discovery of new planets
Resumo:
In this paper, an experimental set-up which differs from the traditional ones is established in order to determine the moment of inertia of a right circular cone. Its angular variation and inertia ellipsoid are determined by means of an experimental study. In addition, a system that allows for the evaluation of the angular acceleration and torque through electric current or frequency measurement is utilized.
Resumo:
Background: The gait automaticity loss difficults realization of concurrent activities - Dual Task (DT). In these situations, individuals with Parkinson`s disease (PD) show a significant reduction in gait velocity and stride length, as strides variability and asymmetry increased, factors predisposing to falls. However, recent studies have shown that training involving DT may cause subsequent improvements in gait variables with DT in individuals with PD. The treadmill use was adopted by this study, by promoting greater regularity in step and enhance training. Objective:To investigate immediate effects of gait training associated with cognitive tasks on gait in individuals with PD. Methods: Twenty-two volunteers were randomly divided into two groups: control group (n = 11), who performed gait training on a treadmill for 20 minutes, and the experimental group (n = 11), who performed treadmill gait training for 20 minutes associated with cognitive tasks of verbal fluency, memory, and spatial planning. Participants were evaluated in phase on of antiparkinsonian medication as the demographic, clinical and anthropometric (identification form), cognitive status (Montreal Cognitive Assessment - MoCA), executive function (Frontal Assessment Battery), level of physical disability (Hoehn and Yahr Modified), motor and functional status (Unified Rating Scale for Parkinson`s Disease - UPDRS), and kinematics (Qualisys Motion Capture System). Results: There were not differences between groups, but both showed improvement after the intervention. The control group had an increase in velocity (p = 0.008), stride length (p = 0.04), step length (p = 0.02) and decreased double support time(p = 0.03). The experimental group showed an increase in speed (p = 0.002), stride length (p = 0.008), step length (p = 0.02) and cadence (p = 0.01), as well as a decrease in the width stride (p = 0.001) and total support time (p = 0.02). As the angular variables, the experimental group had a significant increase in the initial contact angle of ankle (p = 0.01). Conclusion: The gait training combined with cognitive activities didn`t provide significant improvements in gait variables with DT, but this study was the first to demonstrate that gait training on treadmill as simple task minimized the negative interference of DT in PD
Resumo:
The industry's interest in having a greater control of the deformations caused by welding is due to the geometric and dimensional tolerances been more and more precise in the project specifications, motivating the manufacturing engineering to develop stable processes and to ensure routine production. Aiming at it, the main goal of this present work is to analyze how much routine situations used in automatic aluminum welding can influence on the angular deformations of this material. Using the alloy AA 5052 H34, and the automatic welding in pulsed GMAW process, three types of weaving were applied throughout the length of the weld, in butt joints assembled without groove and with 60 degrees single-V-groove, arranged transversely as well as longitudinally to the rolling direction of the plate. The measurement of the deformations was made by a three-dimensional equipment, before and after the welding, in three distinct regions in the specimens. The profile of the weld bead was the main factor for the different types of deformations found, as revealed by macrographical analysis. The 60 degrees single-V-groove had higher amplitudes of deformations as the joint without groove. The torch oscillation wasn't a variable of statistically significant influence on this amplitudes.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The purpose of this paper was to develop a model for calculating the economical flow diameter and velocity, by obtaining the economical diameter, using Swamee's friction factor equation, by minimizing the total annual cost. The application of the model to a regular supply condition showed that the diameter of the actual condition, 250 mm, compared with the diameter calculated by the mode, at the same tariff as that applied to the property ( ground), 284.1 mm, involved the necessity to generate, transmit, and distribute extra electrical energy, due to the higher load loss caused by the original diameter, approximately 30800 kWh/year. This means that in one year, the consumer would spend R$2,804.00 more on pumping cost alone.
Resumo:
The aim of this study was to evaluate the effect of unilateral angular misfit of 100 Km on stress distribution of implant-supported single crowns with ceramic veneering and gold framework by three-dimensional finite element analysis. Two three-dimensional models representing a maxillary section of premolar region were constructed: group 1 (control)-crown completely adapted to the implant and group 2-crown with unilateral angular misfit of 100 Km. A vertical force of 100 N was applied on 2 centric points of the crown. The von Mises stress was used as an analysis criterion. The stress values and distribution in the main maps (204.4 MPa for group 1 and 205.0 MPa for group 2) and in the other structures (aesthetic veneering, framework, retention screw, implant, and bone tissue) were similar for both groups. The highest stress values were observed between the first and second threads of the retention screw. Considering the bone tissue, the highest stress values were exhibited in the peri-implant cortical bone. The unilateral angular misfit of 100 Km did not influence the stress distribution on the implant-supported prosthesis under static loading.
Resumo:
Purpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 pm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 pm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 pm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:788-796
Resumo:
Objective: The purpose of this study was to compare the dental movement that occurs during the processing of maxillary complete dentures with 3 different base thicknesses, using 2 investment methods, and microwave polymerization.Methods: A sample of 42 denture models was randomly divided into 6 groups (n = 7), with base thicknesses of 1.25, 2.50, and 3.75 mm and gypsum or silicone flask investment. Points were demarcated on the distal surface of the second molars and on the back of the gypsum cast at the alveolar ridge level to allow linear and angular measurement using AutoCAD software. The data were subjected to analysis of variance with double factor, Tukey test and Fisher (post hoc).Results: Angular analysis of the varying methods and their interactions generated a statistical difference (P = 0.023) when the magnitudes of molar inclination were compared. Tooth movement was greater for thin-based prostheses, 1.25 mm (-0.234), versus thick 3.75 mm (0.2395), with antagonistic behavior. Prosthesis investment with silicone (0.053) showed greater vertical change compared with the gypsum investment (0.032). There was a difference between the point of analysis, demonstrating that the changes were not symmetric.Conclusions: All groups evaluated showed change in the position of artificial teeth after processing. The complete denture with a thin base (1.25 mm) and silicone investment showed the worst results, whereas intermediate thickness (2.50 mm) was demonstrated to be ideal for the denture base.
Resumo:
O objetivo deste estudo foi comparar a velocidade crítica (VC) determinada através de diferentes distâncias com o limiar anaeróbio (LAn) e as velocidades máximas mantidas em testes de 20 (V20) e 30 (V30) minutos na natação, verificando se a idade cronológica em jovens nadadores interfere nessas relações. Participaram do estudo 31 nadadores (17 meninas e 14 meninos) divididos segundo a idade cronológica em dois grupos: 10 a 12 anos e 13 a 15 anos. O LAn foi determinado como sendo a velocidade correspondente a 4mM de lactato sanguíneo. A VC1 (25/50/100m), VC2 (100/200/400m) e a VC3 (50/100/200m) foram calculadas através do coeficiente angular da reta de regressão linear entre as distâncias e seus respectivos tempos. As V20 e V30 foram determinadas através de três a seis repetições, com coletas de sangue no 10º minuto e ao final do tiro. Para o grupo de 10 a 12 anos, a VC1 (m/s) (0,98 ± 0,17) e o LAn (0,97 ± 0,12) não foram diferentes entre si, sendo maiores do que a VC2 (0,92 ± 0,16), VC3 (0,89 ± 0,18), V20 (0,92 ± 0,11) e V30 (0,90 ± 0,11). Para o grupo de 13 a 15 anos, a VC1 (m/s)(1,11 ± 0,11) foi maior do que o LAn (1,02 ± 0,07), V20 (0,99 ± 0,09), V30 (0,97 ± 0,09), VC2 (0,98 ± 0,11) e VC3 (1,00 ± 0,11). Pode-se concluir que a distância utilizada na determinação da VC interfere no valor obtido, independente da idade cronológica. A VC determinada com distâncias entre 50 e 400m pode ser utilizada na avaliação da capacidade aeróbia de crianças e adolescentes, substituindo os testes contínuos máximos com durações próximas a 20 ou 30 minutos.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Following the discussion-in state-space language-presented in a preceding paper, we work on the passage from the phase-space description of a degree of freedom described by a finite number of states (without classical counterpart) to one described by an infinite (and continuously labelled) number of states. With this it is possible to relate an original Schwinger idea to the Pegg-Barnett approach to the phase problem. In phase-space language, this discussion shows that one can obtain the Weyl-Wigner formalism, for both Cartesian and angular coordinates, as limiting elements of the discrete phase-space formalism.
Resumo:
If we replace the general spacetime group of diffeomorphisms by transformations taking place in the tangent space, general relativity can be interpreted as a gauge theory, and in particular as a gauge theory for the Lorentz group. In this context, it is shown that the angular momentum and the energy-momentum tensors of a general matter field can be obtained from the invariance of the corresponding action integral under transformations taking place, not in spacetime, but in the tangent space, in which case they can be considered as gauge currents.