968 resultados para wrist monitor


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The autonomic nervous system (ANS) plays a role as a modulator in the pathogenesis of paroxysmal atrial fibrillation (PAF). The clinical pattern of vagally mediated PAF has been observed mainly in young patients. Neurocardiogenic responses during orthostatic stress are related to autonomic reflexes in which the vagal influence predominates. AIM: To evaluate the susceptibility of elderly patients with PAF to activation of vasovagal syncope mechanisms. METHODS: We performed passive head-up tilt testing (HUT) in 34 patients (62% women, aged 72 +/- 7 years), with > or = 1 year of clinical history of PAF--19 without structural heart disease, 11 with hypertensive heart disease and 4 with coronary artery disease (who had no previous myocardial infarction, had undergone myocardial revascularization, and had no documented ischemia) (PAF group), and compared the results with those obtained in a group of 34 age-matched patients (53% women, aged 74 +/- 6 years), who underwent HUT due to recurrent syncope (Sc group). In this group, 21 had no documented heart disease and none had a clinical history of AF. There was no diabetes, congestive heart failure or syncope in the PAF group. After a supine resting period, the subjects were tilted at 70 degrees for 20 minutes while in sinus rhythm. No provocative agents were used to complement the HUT. ECG and blood pressure were continuously monitored (Task Force Monitor, CNSystems). The test was considered positive when syncope or presyncope occurred with bradycardia and/or arterial hypotension. Abnormal responses were classified as cardioinhibitory, vasodepressor or mixed. RESULTS: HUT was positive in seven patients of the PAF group--vasodepressor response in five and mixed in two (20.5% of the total; 26.3% of those without heart disease)--and in eight patients (vasodepressor in six and mixed in two) of the Sc group (p=NS). During HUT, three patients of the PAF group had short periods of self-limited PAF (in one, after vasodepressor syncope). There were no differences in gender distribution, age or heart disease. No cardioinhibitory responses or orthostatic hypotension were observed. CONCLUSION: In elderly patients with PAF, a significant number of false positive results during passive HUT may be expected, suggesting increased vasovagal reactions despite aging. This suggests that ANS imbalances may be observed in this population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The autonomic nervous system (ANS) is known to be an important modulator in the pathogenesis of paroxysmal atrial fibrillation (PAF). Changes in ANS control of heart rate variability (HRV) occur during orthostatism to maintain cardiovascular homeostasis. Wavelet transform has emerged as a useful tool that provides time-frequency decomposition of the signal under investigation, enabling intermittent components of transient phenomena to be analyzed. AIM: To study HRV during head-up tilt (HUT) with wavelet transform analysis in PAF patients and healthy individuals (normals). METHODS: Twenty-one patients with PAF (8 men; age 58 +/- 14 yrs) were examined and compared with 21 normals (7 men, age 48 +/- 12 yrs). After a supine resting period, all subjects underwent passive HUT (60 degrees) while in sinus rhythm. Continuous monitoring of ECG and blood pressure was carried out (Task Force Monitor, CNSystems). Acute changes in RR-intervals were assessed by wavelet analysis and low-frequency power (LF: 0.04-0.15 Hz), high-frequency power (HF: 0.15-0.60 Hz) and LF/HF (sympathovagal) were calculated for 1) the last 2 min of the supine period; 2) the 15 sec of tilting movement (TM); and 3) the 1st (TT1) and 2nd (TT2) min of HUT. Data are expressed as means +/- SEM. RESULTS: Baseline and HUT RR-intervals were similar for the two groups. Supine basal blood pressure was also similar for the two groups, with a sustained increase in PAF patients, and a decrease followed by an increase and then recovery in normals. Basal LF, HF and LF/ HF values in PAF patients were 632 +/- 162 ms2, 534 +/- 231 ms2 and 1.95 +/- 0.39 respectively, and 1058 +/- 223 ms2, 789 +/- 244 ms2 and 2.4 +/- 0.36 respectively in normals (p = NS). During TM, LF, HF and LF/HF values for PAF patients were 747 +/- 277 ms2, 387 +/- 94 ms2 and 2.9 +/- 0.6 respectively, and 1316 +/- 315 ms2, 698 +/- 148 ms2 and 2.8 +/- 0.6 respectively in normals (p < 0.05 for LF and HF). During TF1, LF, HF and LF/ HF values for PAF patients were 1243 +/- 432 ms2, 302 +/- 88 ms2 and 7.7 +/- 2.4 respectively, and 1992 +/- 398 ms2, 333 +/- 76 ms2 and 7.8 +/- 0.98 respectively for normals (p < 0.05 for LF). During TF2, LF, HF and LF/HF values for PAF patients were 871 +/- 256 ms2, 242 +/- 51 ms2 and 4.7 +/- 0.9 respectively, and 1263 +/- 335 ms2, 317 +/- 108 ms2 and 8.6 +/- 0.68 respectively for normals (p < 0.05 for LF/HF). The dynamic profile of HRV showed that LF and HF values in PAF patients did not change significantly during TM or TT2, and LF/HF did not change during TM but increased in TT1 and TT2. CONCLUSION: Patients with PAF present alterations in HRV during orthostatism, with decreased LF and HF power during TM, without significant variations during the first minutes of HUT. These findings suggest that wavelet transform analysis may provide new insights when assessing autonomic heart regulation and highlight the presence of ANS disturbances in PAF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Clopidogrel is frequently associated with thrombotic thrombocytopenic purpura, however this drug is rarely related to severe isolated thrombocytopenia. Pentoxifylline has previously been associated with thrombocytopenia only once. To the best of our knowledge, this is the first report of severe isolated thrombocytopenia after therapy with both clopidogrel and pentoxyfilline. CASE PRESENTATION: We report the case of a 79-year-old Caucasian man who presented to our facility with intermittent claudication. He had obliterative arterial disease and started therapy with clopidogrel and pentoxifylline. His basal platelet count was 194 × 109 cells/L. At three days after the start of treatment, our patient had lower limb petechia and stopped taking clopidogrel and pentoxifylline. His platelet count lowered to 4 × 109 cells/L and our patient was admitted to hospital. Our patient had purpura with no other hemorrhages or splenomegaly. Results of a blood smear were normal, and a bone marrow study showed dysmegakaryopoiesis. Antiplatelet antibody test results were negative, as were all viral serology tests. Imaging study results were normal. Our patient was given immunoglobulin but there was no sustained platelet increase, so corticotherapy was started as the next treatment step. At five months after clopidogrel and pentoxifylline were discontinued, his platelet count continued increasing even after prednisolone was tapered. CONCLUSIONS: Severe isolated thrombocytopenia may appear as a side effect when using clopidogrel and pentoxifylline. These drugs are widely used by general physicians, internists, cardiologists and vascular surgeons. We hope this report will raise awareness of the need to monitor the platelet count in patients taking these drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este relatório foi realizado no âmbito da unidade curricular de DIPRE (Dissertação/Projecto/Estágio) lecionada no Mestrado em Engenharia Civil – Infraestruturas, no Instituto Superior de Engenharia do Porto. O estágio foi realizado na Divisão Municipal de Obras e Iluminação Pública, na Câmara Municipal do Porto. Neste relatório procurou-se descrever e caracterizar todos os tipos de pavimentos, desenvolver e estudar novas técnicas de orçamentação e planeamento, e ainda analisar vários casos para mostrar a validade do que se realizou. Este relatório inicia-se com uma primeira parte de âmbito teórico, em que se faz referência aos diferentes tipos de pavimentos, analisando-se o seu comportamento, execução, patologias e métodos de dimensionamento. Para além disso faz-se a interpretação do Decreto-Lei nº 163/2006 e das questões de mobilidade urbana. Para o estágio foram necessárias diversas ferramentas de trabalho, não só fornecidas pela Divisão Municipal de Obras e Iluminação Pública, mas também propostas e exploradas pelo aluno. Com estas ferramentas conseguiu-se desenvolver um novo método de orçamentação, estudando os Rendimentos dos operários para um maior rigor nas estimativas de custo efetuadas. As soluções que se apresentam para mostrar o trabalho desenvolvido foram escolhidas de acordo com a sua importância e abrangência para demonstrar tudo o que foi acompanhado e realizado durante o estágio. Começando pela Rua do Dr. Magalhães Lemos, que foi selecionada porque houve a oportunidade de acompanhar e fiscalizar uma obra que contempla a execução de dois pavimentos distintos, o pavimento flexível e o rígido, em Betão Armado Contínuo. Optou-se também por selecionar dois casos de melhoria da acessibilidade no centro da cidade, porque foram dois projetos desenvolvidos pelo aluno em que se conseguiu explorar as diferentes decisões que teve de se tomar. Por fim, apresenta-se o estudo do dimensionamento da Rua de Santo Ildefonso de acordo com as diretrizes da Câmara Municipal do Porto no percurso académico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O elevado consumo de água associado à escassez deste recurso contribuiu para que alternativas de reutilização/reciclagem de água fossem estudadas que permitam diminuir o seu consumo e minimizar a dependência das indústrias. Monitorizar e avaliar os consumos de água, a nível industrial, é imprescindível para assegurar uma gestão sustentável dos recursos hídricos, sendo este o objetivo da presente dissertação. As alternativas encontradas na unidade industrial em estudo foram a substituição do equipamento sanitário e o aproveitamento do efluente tratado para operações de lavagem e/ou arrefecimento por contacto direto. A maioria do equipamento sanitário não é eficiente, tendo-se proposto a substituição desse sistema por um de menor consumo que permitirá uma poupança de 30 % no consumo de água, que corresponderá a 12 149,37 €/ano, sendo o retorno do investimento estimado em 3 meses. O efluente industrial na entrada da ETAR e nas diferentes etapas - tratamento primário de coagulação/floculação; tratamento secundário ou biológico em SBR; tratamento terciário de coagulação/floculação - foi caracterizado através da medição da temperatura, pH, oxigénio dissolvido e pela determinação da cor, turvação, sólidos suspensos totais (SST), azoto total, carência química de oxigénio (CQO), Carência Bioquímica de Oxigénio ao fim de 5 dias (CBO5) e razão CBO5/CQO. Esta caracterização permitiu avaliar o efluente industrial bruto que se caracteriza por um pH alcalino (8,3 ± 1,7); condutividade baixa (451 ± 200,2 μS/cm); elevada turvação (11 255 ± 8812,8 FTU); cor aparente (63 670 ± 42293,4 PtCo) e cor verdadeira (33 621 ± 19547,9 PtCo) elevadas; teores elevados de CQO (24 753 ± 11806,7 mg/L O2) SST (5 164 ± 3845,5 mg/L) e azoto total (718 mg/L) e um índice de biodegradabilidade baixo (razão CBO5/CQO de 1,4). Este estudo permitiu verificar que a eficiência global do tratamento do efluente foi 82 % na remoção da turvação, 83 % na remoção da cor aparente, 96 % na remoção da cor verdadeira, 85 % na remoção da CQO e 30 % na remoção dos SST. Quanto às eficiências de remoção associadas ao tratamento primário no que diz respeito à turvação, cor aparente, CQO e SST, apresentam valores inferiores aos referidos na literatura para o mesmo tipo de tratamento em efluentes similares. As eficiências de remoção obtidas no tratamento secundário são inferiores às do tratamento primário: turvação, cor aparente, CQO e SST, pelo que procurou-se otimizar a primeira etapa do processo de tratamento Neste estudo de otimização estudou-se a influência de cinco coagulantes – Sulfato de Alumínio, PAX XL – 10, PAX 18, cloreto de ferro e a conjugação de PAX 18 com sulfato de ferro - e seis floculantes – Superfloc A 150, Superfloc A 130, PA 1020, Ambifloc 560, Ambifloc C58 e Rifloc 54 - no tratamento físico-químico do efluente. O PAX 18 e o Ambifloc 560 UUJ foram os que apresentaram as mais elevadas eficiências de remoção (99,85 % na cor, 99,87 % na turvação, 90,12 % na CQO e 99,87 % nos SST). O custo associado a este tratamento é de 1,03 €/m3. Pela comparação com os critérios de qualidade no guia técnico ERSAR, apenas o parâmetro da CQO excede o valor, contudo o valor obtido permite diminuir os custos associados a um tratamento posterior para remoção da CQO remanescente no efluente residual tratado.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O outsourcing tem aumentado exponencialmente nos últimos anos, o que se deve ao aumento da especialização das organizações. Como consequência, a responsabilidade do departamento de compras também aumenta. O mesmo será dizer que cada vez mais as organizações se tornam dependentes dos seus fornecedores, necessitando por isso de recorrer a metodologias que lhes permitam monitorizar/avaliar fornecedores capazes de, em conjunto, criar valor e reduzir custos. O propósito deste trabalho é analisar e desenvolver um procedimento de Monitorização e Avaliação de Fornecedores que permita avaliar o desempenho dos fornecedores, identificando aqueles que são capazes de acompanhar o desenvolvimento e a sustentabilidade da organização.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Smart Cities are designed to be living systems and turn urban dwellers life more comfortable and interactive by keeping them aware of what surrounds them, while leaving a greener footprint. The Future Cities Project [1] aims to create infrastructures for research in smart cities including a vehicular network, the BusNet, and an environmental sensor platform, the Urban Sense. Vehicles within the BusNet are equipped with On Board Units (OBUs) that offer free Wi-Fi to passengers and devices near the street. The Urban Sense platform is composed by a set of Data Collection Units (DCUs) that include a set of sensors measuring environmental parameters such as air pollution, meteorology and noise. The Urban Sense platform is expanding and receptive to add new sensors to the platform. The parnership with companies like TNL were made and the need to monitor garbage street containers emerged as air pollution prevention. If refuse collection companies know prior to the refuse collection which route is the best to collect the maximum amount of garbage with the shortest path, they can reduce costs and pollution levels are lower, leaving behind a greener footprint. This dissertation work arises in the need to monitor the garbage street containers and integrate these sensors into an Urban Sense DCU. Due to the remote locations of the garbage street containers, a network extension to the vehicular network had to be created. This dissertation work also focus on the Multi-hop network designed to extend the vehicular network coverage area to the remote garbage street containers. In locations where garbage street containers have access to the vehicular network, Roadside Units (RSUs) or Access Points (APs), the Multi-hop network serves has a redundant path to send the data collected from DCUs to the Urban Sense cloud database. To plan this highly dynamic network, the Wi-Fi Planner Tool was developed. This tool allowed taking measurements on the field that led to an optimized location of the Multi-hop network nodes with the use of radio propagation models. This tool also allowed rendering a temperature-map style overlay for Google Earth [2] application. For the DCU for garbage street containers the parner company provided the access to a HUB (device that communicates with the sensor inside the garbage containers). The Future Cities use the Raspberry pi as a platform for the DCUs. To collect the data from the HUB a RS485 to RS232 converter was used at the physical level and the Modbus protocol at the application level. To determine the location and status of the vehicles whinin the vehicular network a TCP Server was developed. This application was developed for the OBUs providing the vehicle Global Positioning System (GPS) location as well as information of when the vehicle is stopped, moving, on idle or even its slope. To implement the Multi-hop network on the field some scripts were developed such as pingLED and “shark”. These scripts helped upon node deployment on the field as well as to perform all the tests on the network. Two setups were implemented on the field, an urban setup was implemented for a Multi-hop network coverage survey and a sub-urban setup was implemented to test the Multi-hop network routing protocols, Optimized Link State Routing Protocol (OLSR) and Babel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To compare sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of self-diagnosis for head lice infestation with visual inspection, we conducted a study in an urban slum in Brazil. Individuals were asked about active head lice infestation (self-diagnosis); we performed visual inspection and thereafter wet combing (gold standard). Of the 175 individuals included, 77 (44%) had an active head lice infestation. For self-diagnosis, sensitivity (80.5%), specificity (91.8%), PPV (88.6%) and NPV (85.7%) were high. Sensitivity of visual inspection was 35.1%. Public health professionals can use self-diagnosis as a diagnostic tool, to estimate accurately prevalence of pediculosis in a community, and to monitor ongoing intervention strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este relatório apresenta o estágio curricular relativo ao curso de mestrado em engenharia civil na área de especialização de estruturas. O estágio decorreu no grupo O Feliz, S.A, uma metalomecânica sedeada em Braga. No âmbito do estágio, foi efetuada uma pesquisa e de seguida um projeto real aplicando a metodologia Building Information Modeling. Inicialmente, será feita uma apresentação da empresa e definidos os objetivos propostos para o estágio. Seguidamente, será apresentada toda a pesquisa realizada sobre o BIM para poder, seguidamente, realizar um projeto real utilizando esta metodologia, proposta pela empresa. Posteriormente é apresentado o projeto realizado com a metodologia BIM e todo o seu processo até chegar à sua construção. Por último, são apresentadas algumas das obras que estavam em curso durante a realização do presente trabalho e que houve a oportunidade de acompanhar, refletindo a experiência adquirida na área, durante o desenvolvimento do estágio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study was carried out in the area of influence of the Porto Primavera Hydroelectric Power Station, in western São Paulo State, to investigate ecological and epidemiological aspects of malaria in the area and monitor the profile of the anopheline populations following the environmental changes brought about by the construction of the lake. Mosquitoes captured were analyzed by standardized indicator species analysis (ISA) before and during different flooding phases (253 m and 257 m elevations). The local human population was studied by means of parasitological (thin/thick blood smears), molecular (PCR) and serological tests. Serological tests consisted of Enzyme Linked Immunosorbent Assay (ELISA) with synthetic peptides of the circumsporozoite protein (CSP) from classic Plasmodium vivax, P. vivax variants (VK247 and "vivax-like"), P. malariae and P. falciparum and Indirect Immunofluorescence Assay (IFA) with asexual forms of P. vivax, P. malariae and P. falciparum. The results of the entomological survey indicated that, although the Anopheles darlingi population increased after the flooding, the population density remained very low. No malaria, parasite infection or DNA was detected in the inhabitants of the study area. However, there was a low frequency of antibodies against asexual forms and a significant prevalence of antibodies against P. vivax, P. vivax variants, P. falciparum and P. malariae; the presence of these antibodies may result from recent or less recent contact with human or simian Plasmodium (a parallel study in the same area revealed the existence of a sylvatic cycle). Nevertheless, these results suggest that, as in other places where malaria is present and potential vectors circulate, the local epidemiological conditions observed could potentially support the transmission of malaria in Porto Primavera Lake if infected individuals are introduced in sufficient numbers. Further studies are required to elucidate the phenomena described in this paper.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertation to obtain the Master degree in Electrical Engineering and Computer Science

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The quantitation of serum HBeAg is not commonly used to monitor viral response to therapy in chronic hepatitis B. METHODS: In this study, 21 patients receiving varying therapies were followed and their viral response monitored by concomitant viral load and HBeAg quantitation in order to study the meaning and the kinetics of both parameters. RESULTS: It was possible to distinguish between three different patterns of viral response. The first was characterized by a simultaneous decrease in serum HBV DNA and HBeAg. The second pattern was characterized by a decrease in serum HBeAg but persistent detection of HBV DNA. The third pattern was characterized by undetectable HBV DNA with persistent HBeAg positivity, which points to a non-response (Pattern III-B) except when HBeAg levels showed a slow but steady drop, characterizing a "slow responder" patient (Pattern III-A). CONCLUSIONS: The first pattern is compatible with a viral response. A long-term HBeAg seropositivity with a slow and persistent decrease (Pattern III-A) is also compatible with a viral response and calls for a prolongation of anti-viral treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente trabalho enquadra-se na área das redes de computadores, fazendo referência aos protocolos e ao conjunto de equipamentos e softwares necessários para a administração, controlo e monitorização desse tipo de infra-estruturas. Para a gestão de uma rede de dados, é essencial dispor de conhecimentos e documentação de nível técnico para representar da forma mais fiel possível a configuração da rede, seguindo passo a passo a interligação entre equipamentos existentes e oferecendo assim uma visão o mais fidedigna possível das instalações. O protocolo SNMP é utilizado em larga escala sendo praticamente um standard para a administração de redes baseadas na tecnologia TCP/IP. Este protocolo define a comunicação entre um administrador e um agente, estabelecendo o formato e o significado das mensagens trocadas entre ambos. Tem a capacidade de suportar produtos de diferentes fabricantes, permitindo ao administrador manter uma base de dados com informações relevantes da monitorização de vários equipamentos, que pode ser consultada e analisada por softwares NMS concebidos especialmente para a gestão de redes de computadores. O trabalho apresentado nesta dissertação teve como objectivo utilizar uma ferramenta NMS, para fazer a monitorização e a gestão da infra-estrutura de comunicações de forma que permitisse conhecer em tempo real o estado dos elementos de rede, ajudar no diagnóstico de possíveis problemas, instalados pela Nonius nos diversos navios da frota Douro Azul. O software NMS escolhido utiliza as potencialidades do protocolo SNMP para adquirir dados de monitorização de equipamentos de rede presentes na rede, bem como monitorizar redes remotas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Temporomandibular disorders (TMD) consist of a group of pathologies that affect the masticatory muscles, temporomandibular joints (TMJ), and/or related structures. String instrumentalists, like many orchestra musicians, can spend hours with head postures that may influence the biomechanical behavior of the TMJ and the muscles of the craniocervicomandibular complex (CCMC). The adoption of abnormal postures acquired during performance by musicians can lead to muscular hyperactivity of the head and cervical muscles, with the possible appearance of TMD. Medical infrared thermography is a non-invasive procedure that can monitor the changes in the superficial tissue related to blood circulation and may serve as a complement to the clinical examination. The objective of this study was to use infrared thermography to evaluate, in one subject, the cutaneous thermal changes adjacent to the CCMC that occur before, during, and after playing a string instrument.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To examine the combined effects of physical activity and weight status on blood pressure (BP) in preschool-aged children. Study design The sample included 733 preschool-aged children (49% female). Physical activity was objectively assessed on 7 consecutive days by accelerometry. Children were categorized as sufficiently active if they met the recommendation of at least 60 minutes daily of moderate-to-vigorous physical activity (MVPA). Body mass index was used to categorize children as nonoverweight or overweight/obese, according to the International Obesity Task Force benchmarks. BP was measured using an automated BP monitor and categorized as elevated or normal using BP percentile-based cut-points for age, sex, and height. Results The prevalence of elevated systolic BP (SBP) and diastolic BP was 7.7% and 3.0%, respectively. The prevalence of overweight/obese was 32%, and about 15% of children did not accomplish the recommended 60 minutes of daily MVPA. After controlling for age and sex, overweight/obese children who did not meet the daily MVPA recommendation were 3 times more likely (OR 3.8; CI 1.6-8.6) to have elevated SBP than nonoverweight children who met the daily MVPA recommendation. Conclusions Overweight or obese preschool-aged children with insufficient levels of MVPA are at significantly greater risk for elevated SBP than their non overweight and sufficiently active counterparts. (J Pediatr 2015;167:98-102).