974 resultados para rotational band
Resumo:
We present time-resolved J-band spectroscopy of the short-period cataclysmic variable SDSS J143317.78+101123.3. We detect absorption lines from the sub-stellar donor star in this system, which contributes 38 +/- 5 per cent to the J-band light. From the relative strengths of the absorption lines in the J band, we estimate the spectral type of the donor star to be L2 +/- 1. These data are the first spectroscopic detection of a donor with a confirmed sub-stellar mass in a cataclysmic variable, and the spectral type is consistent with that expected from semi-empirical evolutionary models.
Using skew mapping, we have been able to derive an estimate for the radial velocity of the donor of K-d = 520 +/- 60 km/s. This value is consistent with, though much less precise than, predictions from mass determinations found via photometric fitting of the eclipse light curves.
Resumo:
This Letter reports in situ Fourier transform infrared (FTIR) spectroscopic data on thermal TiO films fabricated by heating titanium plates in air at 475, 700 and 800 °C. The films were studied in the dark and under UV-irradiation in aqueous 0.1MNaClO in the presence and absence of 0.1 M Na(OOC) and at 10, 25 and 50 °C. The film fabricated at 800 °C showed a broad feature near 1580cm under UV-irradiation that was not observed in the dark, whilst the films fabricated at lower temperatures, 475 and 700 °C, showed no such feature. This feature appears to be associated with the accumulation of surface-mobile holes at the complex, porous film-electrolyte interface and the capacity of such holes to enhance the absorption cross-section of optical phonons characteristic of the rutile crystal form at and near the surface of the TiO/electrolyte interface. © 2001 Elsevier Science B.V.
Resumo:
We present the probable ground-based detection of the secondary eclipse of the transiting exoplanet WASP-19b. The observations were made in the Sloan z'-band using the ULTRACAM triple-beam CCD camera mounted on the NTT. The measurement shows a 1±0.2mmag eclipse depth, consistent with a dayside temperature of 2900K, matching previous predictions based on H- and K-band measurements. However, since this is based on a single observation, the eclipse depth - at the moment - is not particularly well constrained, and would benefit from additional observations at similar wavelengths. Our technique for the data reduction and analysis is described, along with our approach to dealing with systematic errors associated with ground-based secondary eclipse observations.
Resumo:
Purpose: In this study the Octavius detector 729 ionization chamber (IC) array with the Octavius 4D phantom was characterized for flattening filter (FF) and flattening filter free (FFF) static and rotational beams. The device was assessed for verification with FF and FFF RapidArc treatment plans.
Methods: The response of the detectors to field size, dose linearity, and dose rate were assessed for 6 MV FF beams and also 6 and 10 MV FFF beams. Dosimetric and mechanical accuracy of the detector array within the Octavius 4D rotational phantom was evaluated against measurements made using semiflex and pinpoint ionization chambers, and radiochromic film. Verification FF and FFF RapidArc plans were assessed using a gamma function with 3%/3 mm tolerances and 2%/2 mm tolerances and further analysis of these plans was undertaken using film and a second detector array with higher spatial resolution.
Results: A warm-up dose of >6 Gy was required for detector stability. Dose-rate measurements were stable across a range from 0.26 to 15 Gy/min and dose response was linear, although the device overestimated small doses compared with pinpoint ionization chamber measurements. Output factors agreed with ionization chamber measurements to within 0.6% for square fields of side between 3 and 25 cm and within 1.2% for 2 x 2 cm(2) fields. The Octavius 4D phantom was found to be consistent with measurements made with radiochromic film, where the gantry angle was found to be within 0.4. of that expected during rotational deliveries. RapidArc FF and FFF beams were found to have an accuracy of >97.9% and >90% of pixels passing 3%/3 mm and 2%/2 mm, respectively. Detector spatial resolution was observed to be a factor in determining the accurate delivery of each plan, particularly at steep dose gradients. This was confirmed using data from a second detector array with higher spatial resolution and with radiochromic film.
Conclusions: The Octavius 4D phantom with associated Octavius detector 729 ionization chamber array is a dosimetrically and mechanically stable device for pretreatment verification of FF and FFF RapidArc treatments. Further improvements may be possible through use of a detector array with higher spatial resolution (detector size and/or detector spacing). (C) 2013 American Association of Physicists in Medicine.
Resumo:
Single and double layer frequency selective surfaces (FSS) for Circular polarization (CP) operation were designed. The designed FSS provide reflection in the Ku-band (11.7 – 12.75 GHz) and transmission in the Ka-band (17.3 – 20.2 GHz). CP is conserved in each of the bands. For the double layer design over the Ku-band the reflection loss was less than 0.05 dB for TE and TM polarizations while the axial ratio was below 0.2 dB. Over the Ka-band transmission loss and axial ratio were each less than 0.25 dB.
Resumo:
A frequency selective surface (FSS) which can be utilized as a diplexer for circular polarization (CP) applications is proposed. The structure consists of two dipole-based FSS placed parallel to each other. The dipoles in one array are rotated by 90° with respect to those in the other. For an angle of incidence of 45° at one frequency band the structure allows a CP signal to be transmitted while at a further band it converts a linearly polarized (LP) signal to CP upon reflection. Full-wave simulation results validated the concept.
Resumo:
This paper presents the design and implementation of a differential 4-way power-combining amplifier operating at E-band. The proposed 4-way power combiner (4WPC) facilitates short interconnects to the PA cells, thereby resulting in reduced loss. Simple C-L-C and L-C networks are deployed in order to compensate inductive loading due to the routing lines that would otherwise introduce mismatch and subsequently increase overall loss. Realized in SiGe technology, the PA prototype delivered 13.2 dBm output-referred 1-dB compression point and 14.3 dBm saturated output power when operated from a single 3.3 V DC supply at 75 GHz.
Resumo:
Various grades of Thermoplastic Polyurethane (TPU) supplied by Bayer were studied to determine their suitability for the rotational moulding process. Following grinding, parts were produced using a variety of peak internal air temperatures and cooling rates. The tensile and impact properties of these parts were then analysed and it was found that both the grade and moulding conditions had a large bearing on the quality and mechanical strength of the part produced.
Resumo:
Rotational moulding promises designers attractive economics and a low-pressure process. The benefits of rotational moulding are compared here with other manufacturing methods such as injection and blow moulding.
Resumo:
The potential of multiple layer fibre-reinforced mouldings is of growing interest to the rotational moulding industry because of their cost/performance ratio. The particular problem that arises when using reinforcements in this process relate to the fact that the process is low shear and good mixing of resin and reinforcement is not optimum under those conditions. There is also a problem of the larger/heavier reinforcing agents segregating out of the powder to lay up on the inner part surface. In this study, short glass fibres were incorporated and distributed into a polymer matrix to produce fibre-reinforced polymer composites using the rotational moulding process and characterised in terms of morphology and mechanical properties. © 2011 American Institute of Physics.
Resumo:
This paper reports the findings from internal mould cooling trials using a water spray configuration applied at various internal mould air temperatures from 120°C to 180°C for an aluminium mould. To achieve maximum benefit in terms of cycle time reduction, internal mould water cooling was used in conjunction with a combination of external forced air and water cooling. Savings in cooling times of up to 30% were achieved compared to conventional external only forced air cooling.