905 resultados para metabolizable energy requirements
Resumo:
This paper investigates cooling energy performance of commercial building before and after green roof and living wall application based on integrated building heat gain model developed from Overall Thermal Transfer Value (OTTV) of building wall and steady state heat transfer process of roof in sub-tropical climate. Using the modelled equation and eQUEST energy simulation tool, commercial building envelope parameters and relevant heat gain parameters have been accumulated to analyse the heat gain and cooling energy consumption of commercial building. Real life commercial building envelope and air-conditioned load data for the sub-tropical climate zone have been collected and compared with the modelled analysis. Relevant temperature data required for living wall and green roof analysis have been collected from experimental setup comprised of both green roof and west facing living wall. Then, Commercial building heat flux and cooling energy performance before and after green roof and living wall application have been scrutinized.
Resumo:
Air conditioning systems have become an integral part of many modern buildings. Proper design and operation of air conditioning systems have significant impact not only on the energy use and greenhouse gas emissions from the buildings, but also on the thermal comfort and productivity of the occupants. In this paper, the purpose and need of installing air conditioning systems is first introduced. The methods used for the classification of air conditioning systems are then presented. This is followed by a discussion on the pros and cons of each type of the air conditioning systems, including both common and new air conditioning technologies. The procedures used to design air conditioning systems are also outlined, and the implications of air conditioning systems, including design, selection, operation and maintenance, on building energy efficiency is also discussed.
Resumo:
This paper discusses and summarises a recent systematic study on the implication of global warming on air conditioned office buildings in Australia. Four areas are covered, including analysis of historical weather data, generation of future weather data for the impact study of global warming, projection of building performance under various global warming scenarios, and evaluation of various adaptation strategies under 2070 high global warming conditions. Overall, it is found that depending on the assumed future climate scenarios and the location considered, the increase of total building energy use for the sample Australian office building may range from 0.4 to 15.1%. When the increase of annual average outdoor temperature exceeds 2 °C, the risk of overheating will increase significantly. However, the potential overheating problem could be completely eliminated if internal load density is significantly reduced.
Resumo:
Exploiting wind-energy is one possible way to ex- tend flight duration for Unmanned Arial Vehicles. Wind-energy can also be used to minimise energy consumption for a planned path. In this paper, we consider uncertain time-varying wind fields and plan a path through them. A Gaussian distribution is used to determine uncertainty in the Time-varying wind fields. We use Markov Decision Process to plan a path based upon the uncertainty of Gaussian distribution. Simulation results that compare the direct line of flight between start and target point and our planned path for energy consumption and time of travel are presented. The result is a robust path using the most visited cell while sampling the Gaussian distribution of the wind field in each cell.
Resumo:
The emergence of semantic technologies to deal with the underlying meaning of things, instead of a purely syntactical representation, has led to new developments in various fields, including business process modeling. Inspired by artificial intelligence research, technologies for semantic Web services have been proposed and extended to process modeling. However, the applicablility of semantic Web services for semantic business processes is limited because business processes encompass wider requirements of business than Web services. In particular, processes are concerned with the composition of tasks, that is, in which order activities are carried out, regardless of their implementation details; resources assigned to carry out tasks, such as machinery, people, and goods; data exchange; and security and compliance concerns.
Resumo:
Voltage drop and rise at network peak and off–peak periods along with voltage unbalance are the major power quality problems in low voltage distribution networks. Usually, the utilities try to use adjusting the transformer tap changers as a solution for the voltage drop. They also try to distribute the loads equally as a solution for network voltage unbalance problem. On the other hand, the ever increasing energy demand, along with the necessity of cost reduction and higher reliability requirements, are driving the modern power systems towards Distributed Generation (DG) units. This can be in the form of small rooftop photovoltaic cells (PV), Plug–in Electric Vehicles (PEVs) or Micro Grids (MGs). Rooftop PVs, typically with power levels ranging from 1–5 kW installed by the householders are gaining popularity due to their financial benefits for the householders. Also PEVs will be soon emerged in residential distribution networks which behave as a huge residential load when they are being charged while in their later generation, they are also expected to support the network as small DG units which transfer the energy stored in their battery into grid. Furthermore, the MG which is a cluster of loads and several DG units such as diesel generators, PVs, fuel cells and batteries are recently introduced to distribution networks. The voltage unbalance in the network can be increased due to the uncertainties in the random connection point of the PVs and PEVs to the network, their nominal capacity and time of operation. Therefore, it is of high interest to investigate the voltage unbalance in these networks as the result of MGs, PVs and PEVs integration to low voltage networks. In addition, the network might experience non–standard voltage drop due to high penetration of PEVs, being charged at night periods, or non–standard voltage rise due to high penetration of PVs and PEVs generating electricity back into the grid in the network off–peak periods. In this thesis, a voltage unbalance sensitivity analysis and stochastic evaluation is carried out for PVs installed by the householders versus their installation point, their nominal capacity and penetration level as different uncertainties. A similar analysis is carried out for PEVs penetration in the network working in two different modes: Grid to vehicle and Vehicle to grid. Furthermore, the conventional methods are discussed for improving the voltage unbalance within these networks. This is later continued by proposing new and efficient improvement methods for voltage profile improvement at network peak and off–peak periods and voltage unbalance reduction. In addition, voltage unbalance reduction is investigated for MGs and new improvement methods are proposed and applied for the MG test bed, planned to be established at Queensland University of Technology (QUT). MATLAB and PSCAD/EMTDC simulation softwares are used for verification of the analyses and the proposals.
Resumo:
Background Socioeconomically-disadvantaged adults in developed countries experience a higher prevalence of a number of chronic diseases, such as cardiovascular disease, type 2 diabetes, osteoarthritis and some forms of cancer. Overweight and obesity are major risk factors for these diseases. Lower socioeconomic groups have a greater prevalence of overweight and obesity and this may contribute to their higher morbidity and mortality. International studies suggest that socioeconomic groups may differ in their self-perceptions of weight status and their engagement in weightcontrol behaviours (WCBs). Research has shown that lower socioeconomic adults are more likely to underestimate their weight status, and are less likely to engage in WCBs. This may contribute (in part) to the marked inequalities in weight status observed at the population level. There are few, and somewhat limited, Australian studies that have examined the types of weight-control strategies people adopt, the barriers to their weight control, the determinants of their perceived weight status and WCBs. Furthermore, there are no known Australian studies that have examined socioeconomic differences in these factors to better understand the reasons for socioeconomic inequalities in weight status. Hence, the overall aim of this Thesis is to examine why socioeconomically-disadvantaged group experience a greater prevalence of overweight and obesity than their more-advantaged counterparts. Methods This Thesis used data from two sources. Men and women aged 45 to 60 years were examined from both data source. First, the longitudinal Australian Diabetes, Obesity and Lifestyle (AusDiab) Study were used to advance our knowledge and understanding of socioeconomic differences in weight change, perceived weight status and WCBs. A total of 2753 participants with measured weights at both baseline (1999-2000) and follow-up (2004-2005) were included in the analyses. Percent weight change over the five-year interval was calculated and perceived weight status, WCBs and highest attained education were collected at baseline. Second, the Candidate conducted a postal questionnaire from 1013 Brisbane residents (69.8 % response rate) to investigate the relationship between socioeconomic position, determinants of perceived weight status, WCBs, and barriers and reasons to weight control. A test-retest reliability study was conducted to determine the reliability of the new measures used in the questionnaire. Most new measures had substantial to almost perfect reliability when considering either kappa coefficient or crude agreement. Results The findings from the AusDiab Study (accepted for publication in the Australian and New Zealand Journal of Public Health) showed that low-educated men and women were more likely to be obese at baseline compared to their higheducated respondents (O.R. = 1.97, 95 % C.I. = 1.30-2.98 and O.R. = 1.52, 95 % C.I. = 1.03-2.25, respectively). Over the five year follow-up period (1999-2000 to 2004- 05) there were no socioeconomic differences in weight change among men, however socioeconomically-disadvantaged women had greater weight gains. Participants perceiving themselves as overweight gained less weight than those who saw themselves as underweight or normal weight. There was no relationship between engaging in WCBs and five-year weight change. The postal questionnaire data showed that socioeconomically-disadvantaged groups were less likely to engage in WCBs. If they did engage in weight control, they were less likely to adopt exercise strategies, including moderate and vigorous physical activities but were more likely to decrease their sitting time to control their weight. Socioeconomically-disadvantaged adults reported more barriers to weight control; such as perceiving weight loss as expensive, requiring a lot of cooking skills, not being a high priority and eating differently from other people in the household. These results have been accepted for publication in Public Health Nutrition. The third manuscript (under review in Social Science and Medicine) examined socioeconomic differences in determinants of perceived weight status and reasons for weight control. The results showed that lower socioeconomic adults were more likely to specify the following reasons for weight control: they considered themselves to be too heavy, for occupational requirements, on recommendation from their doctor, family members or friends. Conversely, high-income adults were more likely to report weight control to improve their physical condition or to look more attractive compared with those on lower-incomes. There were few socioeconomic differences in the determinants of perceived weight status. Conclusions Education inequalities in overweight/obesity among men and women may be due to mis-perceptions of weight status; overweight or obese individuals in loweducated groups may not perceive their weight as problematic and therefore may not pay attention to their energy-balance behaviours. Socioeconomic groups differ in WCBs, and their reasons and perceived barriers to weight control. Health promotion programs should encourage weight control among lower socioeconomic groups. More specifically, they should encourage the engagement of physical activity or exercise and dietary strategies among disadvantaged groups. Furthermore, such programs should address potential barriers for weight control that disadvantaged groups may encounter. For example, disadvantaged groups perceive that weight control is expensive, requires cooking skills, not a high priority and eating differently from other people in the household. Lastly, health promotion programs and policies aimed at reducing overweight and obesity should be tailored to the different reasons and motivations to weight control experienced by different socioeconomic groups. Weight-control interventions targeted at higher socioeconomic groups should use improving physical condition and attractiveness as motivational goals; while, utilising social support may be more effective for encouraging weight control among lower socioeconomic groups.
Resumo:
Green building is building that the focus is to maximize the energy efficiency and resources used. While, retrofitting is the process of renovate or refurnish the existing building. Therefore by retrofit existing buildings that comply with green building requirement, it improves the environmental attributes of the buildings. In Malaysia, existing buildings and its communities contribute over 40% of green house gases to the environment. This paper describes a study that explores the potential to retrofit existing campus buildings that response to sustainable green building standard. A validation survey was carried out and the data collected was analysed using SPSS in order to confirm the significance of retrofitting Universiti Teknologi Malaysia (UTM) buildings toward green building initiative. The results show that all the twenty eight identified green elements recorded average index of higher than 3.5 which means that there is significant needs to retrofit the existing buildings to green buildings. This study concludes that it is urgently need for the campus to response to green building requirements in order to achieve higher energy effeciency and this can be done through effective etrofitting of existing buildings.
Resumo:
Lower energy and protein intakes are well documented in patients on texture modified diets. In acute hospital settings, the provision of appropriate texture modified foods to meet industry standards is essential for patient safety and nutrition outcomes. The texture modified menu at an acute private hospital was evaluated in accordance with their own nutritional standards (NS) and Australian National Standards (Dietitians Association of Australia and Speech Pathology Australia, 2007). The NS documents portion sizes and nutritional requirements for each menu. Texture B and C menus were analysed qualitatively and quantitatively over 9 days of a 6 day cyclic menu for breakfast (n=4), lunch (n=34) and dinner (n=34). Results indicated a lack of portion control, as specified by the NS, across all meals including breakfast (65–140%), soup (55–115%), meat (45–165%), vegetables (55–185%) and desserts (30–300%). Dilution factors and portion sizes influenced the protein and energy availability of Texture B & C menus. While the Texture B menu provided more energy, neither menu met the NS. Limited dessert options on the Texture C menu restricted the ability of this menu to meet protein NS. A lack of portion control and menu items incorrectly modified can compromise protein and energy intakes. Strategies to correct serving sizes and provision of alternate protein sources were recommended. Suggestions included cost-effectively increasing the variety of foods to assist protein and energy intake and the procurement of standardised equipment and visual aids to assist food preparation and presentation in accordance with texture modified guidelines and the NS.
Resumo:
This work is a theoretical investigation into the coupling of a single excited quantum emitter to the plasmon mode of a V groove waveguide. The V groove waveguide consists of a triangular channel milled in gold and the emitter is modeled as a dipole emitter, and could represent a quantum dot, nitrogen vacancy in diamond, or similar. In this work the dependence of coupling efficiency of emitter to plasmon mode is determined for various geometrical parameters of the emitter-waveguide system. Using the finite element method, the effect on coupling efficiency of the emitter position and orientation, groove angle, groove depth, and tip radius, is studied in detail. We demonstrate that all parameters, with the exception of groove depth, have a significant impact on the attainable coupling efficiency. Understanding the effect of various geometrical parameters on the coupling between emitters and the plasmonic mode of the waveguide is essential for the design and optimization of quantum dot–V groove devices.
Resumo:
Appearance-based localization is increasingly used for loop closure detection in metric SLAM systems. Since it relies only upon the appearance-based similarity between images from two locations, it can perform loop closure regardless of accumulated metric error. However, the computation time and memory requirements of current appearance-based methods scale linearly not only with the size of the environment but also with the operation time of the platform. These properties impose severe restrictions on longterm autonomy for mobile robots, as loop closure performance will inevitably degrade with increased operation time. We present a set of improvements to the appearance-based SLAM algorithm CAT-SLAM to constrain computation scaling and memory usage with minimal degradation in performance over time. The appearance-based comparison stage is accelerated by exploiting properties of the particle observation update, and nodes in the continuous trajectory map are removed according to minimal information loss criteria. We demonstrate constant time and space loop closure detection in a large urban environment with recall performance exceeding FAB-MAP by a factor of 3 at 100% precision, and investigate the minimum computational and memory requirements for maintaining mapping performance.
Resumo:
Vertical vegetation is vegetation growing on, or adjacent to, the unused sunlit exterior surfaces of buildings in cities. Vertical vegetation can improve the energy efficiency of the building on which it is installed mainly by insulating, shading and transpiring moisture from foliage and substrate. Several design parameters may affect the extent of the vertical vegetation's improvement of energy performance. Examples are choice of vegetation, growing medium geometry, north/south aspect and others. The purpose of this study is to quantitatively map out the contribution of several parameters to energy savings in a subtropical setting. The method is thermal simulation based on EnergyPlus configured to reflect the special characteristics of vertical vegetation. Thermal simulation results show that yearly cooling energy savings can reach 25% with realistic design choices in subtropical environments. Heating energy savings are negligible. The most important parameter is the aspect of walls covered by vegetation. Vertical vegetation covering walls facing north (south for the northern hemisphere) will result in the highest energy savings. In making plant selections, the most significant parameter is Leaf Area Index (LAI). Plants with larger LAI, preferably LAI>4, contribute to greater savings whereas vertical vegetation with LAI<2 can actually consume energy. The choice of growing media and its thickness influence both heating and cooling energy consumption. Change of growing medium thickness from 6cm to 8cm causes dramatic increase in energy savings from 2% to 18%. For cooling, it is best to use a growing material with high water retention, due to the importance of evapotranspiration for cooling. Similarly, for increased savings in cooling energy, sufficient irrigation is required. Insufficient irrigation results in the vertical vegetation requiring more energy to cool the building. To conclude, the choice of design parameters for vertical vegetation is crucial in making sure that it contributes to energy savings rather than energy consumption. Optimal design decisions can create a dramatic sustainability enhancement for the built environment in subtropical climates.