982 resultados para mapping technique
Resumo:
Any transportation infrastructure system is inherently concerned with durability and performance issues. The proportioning and uniformity control of concrete mixtures are critical factors that directly affect the longevity and performance of the portland cement concrete pavement systems. At present, the only means available to monitor mix proportions of any given batch are to track batch tickets created at the batch plant. However, this does not take into account potential errors in loading materials into storage silos, calibration errors, and addition of water after dispatch. Therefore, there is a need for a rapid, cost-effective, and reliable field test that estimates the proportions of as-delivered concrete mixtures. In addition, performance based specifications will be more easily implemented if there is a way to readily demonstrate whether any given batch is similar to the proportions already accepted based on laboratory performance testing. The goal of the present research project is to investigate the potential use of a portable x-ray fluorescence (XRF) technique to assess the proportions of concrete mixtures as they are delivered. Tests were conducted on the raw materials, paste and mortar samples using a portable XRF device. There is a reasonable correlation between the actual and calculated mix proportions of the paste samples, but data on mortar samples was less reliable.
Resumo:
Debris flows and related landslide processes occur in many regions all over Norway and pose a significant hazard to inhabited areas. Within the framework of the development of a national debris flows susceptibility map, we are working on a modeling approach suitable for Norway with a nationwide coverage. The discrimination of source areas is based on an index approach, which includes topographic parameters and hydrological settings. For the runout modeling, we use the Flow-R model (IGAR, University of Lausanne), which is based on combined probabilistic and energetic algorithms for the assessment of the spreading of the flow and maximum runout distances. First results for different test areas have shown that runout distances can be modeled reliably. For the selection of source areas, however, additional factors have to be considered, such as the lithological and quaternary geological setting, in order to accommodate the strong variation in debris flow activity in the different geological, geomorphological and climate regions of Norway.
Resumo:
OBJECTIVE: The purpose of this article is to assess the effect of the adaptive statistical iterative reconstruction (ASIR) technique on image quality in hip MDCT arthrography and to evaluate its potential for reducing radiation dose. SUBJECTS AND METHODS: Thirty-seven patients examined with hip MDCT arthrography were prospectively randomized into three different protocols: one with a regular dose (volume CT dose index [CTDIvol], 38.4 mGy) and two with a reduced dose (CTDIvol, 24.6 or 15.4 mGy). Images were reconstructed using filtered back projection (FBP) and four increasing percentages of ASIR (30%, 50%, 70%, and 90%). Image noise and contrast-to-noise ratio (CNR) were measured. Two musculoskeletal radiologists independently evaluated several anatomic structures and image quality parameters using a 4-point scale. They also jointly assessed acetabular labrum tears and articular cartilage lesions. RESULTS: With decreasing radiation dose level, image noise statistically significantly increased (p=0.0009) and CNR statistically significantly decreased (p=0.001). We also found a statistically significant reduction in noise (p=0.0001) and increase in CNR (p≤0.003) with increasing percentage of ASIR; in addition, we noted statistically significant increases in image quality scores for the labrum and cartilage, subchondral bone, overall diagnostic quality (up to 50% ASIR), and subjective noise (p≤0.04), and statistically significant reductions for the trabecular bone and muscles (p≤0.03). Regardless of the radiation dose level, there were no statistically significant differences in the detection and characterization of labral tears (n=24; p=1) and cartilage lesions (n=40; p≥0.89) depending on the ASIR percentage. CONCLUSION: The use of up to 50% ASIR in hip MDCT arthrography helps to reduce radiation dose by approximately 35-60%, while maintaining diagnostic image quality comparable to that of a regular-dose protocol using FBP.
Resumo:
PURPOSE: At 7 Tesla (T), conventional static field (B0 ) projection mapping techniques, e.g., FASTMAP, FASTESTMAP, lead to elevated specific absorption rates (SAR), requiring longer total acquisition times (TA). In this work, the series of adiabatic pulses needed for slab selection in FASTMAP is replaced by a single two-dimensional radiofrequency (2D-RF) pulse to minimize TA while ensuring equal shimming performance. METHODS: Spiral gradients and 2D-RF pulses were designed to excite thin slabs in the small tip angle regime. The corresponding selection profile was characterized in phantoms and in vivo. After optimization of the shimming protocol, the spectral linewidths obtained after 2D localized shimming were compared with conventional techniques and published values from (Emir et al NMR Biomed 2012;25:152-160) in six different brain regions. RESULTS: Results on healthy volunteers show no significant difference (P > 0.5) between the spectroscopic linewidths obtained with the adiabatic (TA = 4 min) and the new low-SAR and time-efficient FASTMAP sequence (TA = 42 s). The SAR can be reduced by three orders of magnitude and TA accelerated six times without impact on the shimming performances or quality of the resulting spectra. CONCLUSION: Multidimensional pulses can be used to minimize the RF energy and time spent for automated shimming using projection mapping at high field. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.
Resumo:
BACKGROUND: Chest wall resection and reconstruction can be performed with minimal mortality and excellent functional and cosmetic results using synthetic meshes, methylmethacrylate, or other substitutes. However, these techniques are less easily applicable if chest wall resections have to be performed for infections. METHODS: We report a novel technique for this purpose using a modified latissimus dorsi flap harvested in continuity with the thoracolumbar fascia. The vascularized fascia was sutured into the chest wall defect, providing a stable base for the muscular component of the flap. Three patients requiring large full-thickness resections of the anterolateral chest wall for chronic infections were treated accordingly, two presenting with chronic radionecrosis and osteomyelitis and one with chest wall invasion by pulmonary aspergillosis. RESULTS: There were no intraoperative or postoperative complications and immediate extubation was possible in all 3 patients without the need for postoperative ventilation or tracheotomy. Healing of the infected chest wall was observed in all 3 patients. Postoperative cinemagnetic resonance imaging revealed concordant movements of the replaced segments without evidence of paradoxical motion during inspiration and expiration. CONCLUSIONS: This technique is easy and safe. It allows a stable and satisfactory reconstruction after large anterolateral full-thickness chest wall resections of infected, previously irradiated tissues, using only well-vascularized autologous tissue.
Resumo:
PURPOSE: To compare different techniques for positive contrast imaging of susceptibility markers with MRI for three-dimensional visualization. As several different techniques have been reported, the choice of the suitable method depends on its properties with regard to the amount of positive contrast and the desired background suppression, as well as other imaging constraints needed for a specific application. MATERIALS AND METHODS: Six different positive contrast techniques are investigated for their ability to image at 3 Tesla a single susceptibility marker in vitro. The white marker method (WM), susceptibility gradient mapping (SGM), inversion recovery with on-resonant water suppression (IRON), frequency selective excitation (FSX), fast low flip-angle positive contrast SSFP (FLAPS), and iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) were implemented and investigated. RESULTS: The different methods were compared with respect to the volume of positive contrast, the product of volume and signal intensity, imaging time, and the level of background suppression. Quantitative results are provided, and strengths and weaknesses of the different approaches are discussed. CONCLUSION: The appropriate choice of positive contrast imaging technique depends on the desired level of background suppression, acquisition speed, and robustness against artifacts, for which in vitro comparative data are now available.
Resumo:
The regulation of gene expression is crucial for an organism's development and response to stress, and an understanding of the evolution of gene expression is of fundamental importance to basic and applied biology. To improve this understanding, we conducted expression quantitative trait locus (eQTL) mapping in the Tsu-1 (Tsushima, Japan) × Kas-1 (Kashmir, India) recombinant inbred line population of Arabidopsis thaliana across soil drying treatments. We then used genome resequencing data to evaluate whether genomic features (promoter polymorphism, recombination rate, gene length, and gene density) are associated with genes responding to the environment (E) or with genes with genetic variation (G) in gene expression in the form of eQTLs. We identified thousands of genes that responded to soil drying and hundreds of main-effect eQTLs. However, we identified very few statistically significant eQTLs that interacted with the soil drying treatment (GxE eQTL). Analysis of genome resequencing data revealed associations of several genomic features with G and E genes. In general, E genes had lower promoter diversity and local recombination rates. By contrast, genes with eQTLs (G) had significantly greater promoter diversity and were located in genomic regions with higher recombination. These results suggest that genomic architecture may play an important a role in the evolution of gene expression.
Resumo:
Treatment of symptomatic pharyngeal and esophageal strictures requires endoscopic dilatation. The Savary-Gilliard bougienage was developed by our department and has been used since 1980 for this purpose. We report our experience using this technique. The records of patients seen from January 1, 1963 to December 31, 2005, who had pharyngeal and esophageal strictures needing dilatation, were reviewed. The prevalence of different etiologies, and the incidence of complications using the Savary-Gilliard dilators were assessed. Efficiency of dilatation was assessed over a 17-year segment of this period, using number of dilatations and time intervals between dilatations until resolution of symptoms as outcome measures. Of the 2,652 pharyngeal and esophageal strictures reviewed, 90% were of organic origin (45% benign and 55% malignant stenoses), and 10% were of functional etiology. The most common etiologies were peptic strictures before the era of proton pump inhibitors, and postoperative anastomotic strictures thereafter. A total of 1,862 dilatations using the Savary-Gilliard technique were analyzed. Complication and mortality rates were 0.18 and 0.09% for benign and 4.58 and 0.81% for malignant etiologies, respectively. The number of dilatations per stricture and the time interval between different sessions were dependent on the type of strictures, varying from 1 to 23 dilatations and 7 days to 16 years, respectively. Pharyngeal and esophageal dilatations using the Savary-Gilliard technique were safe when used together with fluoroscopy. Overall, the efficiency of the dilatation procedure was good, but some types of strictures (e.g., caustic, post-surgical and/or post radiotherapy) were refractory to treatment and required repeated dilatations.
Resumo:
The paper presents the Multiple Kernel Learning (MKL) approach as a modelling and data exploratory tool and applies it to the problem of wind speed mapping. Support Vector Regression (SVR) is used to predict spatial variations of the mean wind speed from terrain features (slopes, terrain curvature, directional derivatives) generated at different spatial scales. Multiple Kernel Learning is applied to learn kernels for individual features and thematic feature subsets, both in the context of feature selection and optimal parameters determination. An empirical study on real-life data confirms the usefulness of MKL as a tool that enhances the interpretability of data-driven models.
Resumo:
OBJECTIVES: A straightforward original Chimney Graft (CG) protocol has been developed at our institution in selected cases of juxtarenal aortic aneurysm (JRAA). The aim of this study was to present our clinical experience of consecutive series with use of uncovered self-expanding stent (SES) as "Open Chimney" (OCh) in the endovascular repair (EVAR) of JRAA. METHODS: A standard endograft with suprarenal fixation struts is delivered with its proximal covered edge just below the highest RA in JRAA presenting the ostium of the two renal arteries at a different aortic level and the distance between the highest renal artery and the beginning of the aneurysm (improved landing zone) ≥10 mm. The low-lying renal artery is maintained patent by the OCh graft (standard SES) delivered from left brachial access (6 Fr). All clinical, anatomical, and operative data were prospectively collected and retrieved for the study analysis. RESULTS: From July 2010 to November 2012, OCh EVAR was offered to 22 consecutive patients considered unfit for JRAA open repair. All procedures were technically successful with aneurysm exclusion and patent OCh graft. One small perioperative type Ia endoleak spontaneously disappeared at the 3-month CT control. One patient died because of acute decompensated heart failure. One patient presented a left hemispheric stroke. The median follow-up of 18 months (range 7-35) showed aneurysm exclusion in all patients without type I and III endoleaks, SES stenosis, and/or renal impairment. CONCLUSIONS: OCh-EVAR is a straightforward technique that can be employed in selected cases of JRAA, avoiding the more complex and expensive fenestrated EVAR.