982 resultados para drug-susceptibility testing
Resumo:
Purpose: To test the strength to failure and fracture mode of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments vs cemented standard porcelain-fused-to-metal (PFM) crowns. Materials and Methods: Sixty-four locking taper abutments were randomly allocated to four groups and were cleaned in ethanol in an ultrasonic bath for 5 min. After drying under ambient conditions, the abutments were grit blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n = 16 per group) of Tescera (Bisco), Ceramage (Shofu), and Diamond Crown (DRM) according to the manufacturer`s instructions. The porcelain-fused-to-metal crowns were fabricated by conventional means involving the construction and a wax pattern and casting of a metallic coping followed by sintering of increasing layers of porcelain. All crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1 mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% level of significance was utilized for statistical analysis. Results: The single load to failure (+/- SD) results were: Tescera (1130 +/- 239 N), Ceramage (1099 +/- 257 N), Diamond Crown (1155 +/- 284 N), and PFM (1081 +/- 243 N). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment/metallic coping exposure. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. Conclusion: The three indirect composites and PFM systems fractured at loads higher than those typically associated with normal occlusal function. Although each material had a different composition and handling technique, no significant differences were found concerning their single load to fracture resistance among composite systems and PFM.
Resumo:
This study evaluated the stress levels at the core layer and the veneer layer of zirconia crowns (comprising an alternative core design vs. a standard core design) under mechanical/thermal simulation, and subjected simulated models to laboratory mouth-motion fatigue. The dimensions of a mandibular first molar were imported into computer-aided design (CAD) software and a tooth preparation was modeled. A crown was designed using the space between the original tooth and the prepared tooth. The alternative core presented an additional lingual shoulder that lowered the veneer bulk of the cusps. Finite element analyses evaluated the residual maximum principal stresses fields at the core and veneer of both designs under loading and when cooled from 900 degrees C to 25 degrees C. Crowns were fabricated and mouth-motion fatigued, generating master Weibull curves and reliability data. Thermal modeling showed low residual stress fields throughout the bulk of the cusps for both groups. Mechanical simulation depicted a shift in stress levels to the core of the alternative design compared with the standard design. Significantly higher reliability was found for the alternative core. Regardless of the alternative configuration, thermal and mechanical computer simulations showed stress in the alternative core design comparable and higher to that of the standard configuration, respectively. Such a mechanical scenario probably led to the higher reliability of the alternative design under fatigue.
Resumo:
Antibody isotypic responses (IgE, IgA, IgG1, IgG2, IgG3 and IgG4) to Schistosoma japonicum antigens-adult worm (AWA), soluble egg (SEA) and the recombinant proteins TEG (22.6-kDa tegumental antigen, Sj22) and PMY (paramyosin, Sj97)-were measured (in 1998) in a cohort of 179 Chinese subjects 2 years post-treatment. Subjects in the highest intensity re-infection group (> 100 eggs per gram faeces) had significantly higher levels of IgG1 and IgG4 against AWA. Analysis of IgG4/IgE ratios for AWA and SEA linked IgG4 excess to re-infection and IgE excess to non-re-infection. Two years after chemotherapeutic cure, 29 subjects, who were re-infected or never infected but highly water-exposed, were classified as epidemiologically susceptible (n = 15) or epidemiologically insusceptible to infection (n = 14). IgG4 levels against native antigens (AWA and SEA) were higher in susceptibles and IgE levels were higher in insusceptibles but antibody responses to the recombinant proteins (PMY and TEG) showed no clear pattern or difference between susceptibility groups. These and earlier findings provide evidence that immunity develops against schistosomiasis japonica in China and that susceptibility/resistance correlates with antibody isotypes against native schistosome antigens.
Resumo:
P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.
Resumo:
A range of topical products are used in veterinary medicine. The efficacy of many of these products has been enhanced by the addition of penetration enhancers. Evolution has led to not only a highly specialized skin in animals and humans, but also one whose anatomical structure and skin permeability differ between the various species. The skin provides an excellent barrier against the ingress of environmental contaminants, toxins, and microorganisms while performing a homeostatic role to permit terrestrial life. Over the past few years, major advances have been made in the field of transdermal drug delivery. An increasing number of drugs are being added to the list of therapeutic agents that can be delivered via the skin to the systemic circulation where clinically effective concentrations are reached. The therapeutic benefits of topically applied veterinary products is achieved in spite of the inherent protective functions of the stratum corneum (SQ, one of which is to exclude foreign substances from entering the body. Much of the recent success in this field is attributable to the rapidly expanding knowledge of the SC barrier structure and function. The bilayer domains of the intercellular lipid matrices within the SC form an excellent penetration barrier, which must be breached if poorly penetrating drugs are to be administered at an appropriate rate. One generalized approach to overcoming the barrier properties of the skin for drugs and biomolecules is the incorporation of suitable vehicles or other chemical compounds into a transdermal delivery system. Indeed, the incorporation of such compounds has become more prevalent and is a growing trend in transdermal drug delivery. Substances that help promote drug diffusion through the SC and epidermis are referred to as penetration enhancers, accelerants, adjuvants, or sorption promoters. It is interesting to note that many pour-on and spot-on formulations used in veterinary medicine contain inert ingredients (e.g., alcohols, amides, ethers, glycols, and hydrocarbon oils) that will act as penetration enhancers. These substances have the potential to reduce the capacity for drug binding and interact with some components of the skin, thereby improving drug transport. However, their inclusion in veterinary products with a high-absorbed dose may result in adverse dermatological reactions (e.g., toxicological irritations) and concerns about tissue residues. These a-re important considerations when formulating a veterinary transdermal product when such compounds ate added, either intentionally or otherwise, for their penetration enhancement ability. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Medication data retrieved from Australian Repatriation Pharmaceutical Benefits Scheme (RPBS) claims for 44 veterans residing in nursing homes and Pharmaceutical Benefits Scheme (PBS) claims for 898 nursing home residents were compared with medication data from nursing home records to determine the optimal time interval for retrieving claims data and its validity. Optimal matching was achieved using 12 weeks of RPBS claims data, with 60% of medications in the RPBS claims located in nursing home administration records, and 78% of medications administered to nursing home residents identified in RPBS claims. In comparison, 48% of medications administered to nursing home residents could be found in 12 weeks of PBS data, and 56% of medications present in PBS claims could be matched with nursing home administration records. RPBS claims data was superior to PBS, due to the larger number of scheduled items available to veterans and the veteran's file number, which acts as a unique identifier. These findings should be taken into account when using prescription claims data for medication histories, prescriber feedback, drug utilisation, intervention or epidemiological studies. (C) 2001 Elsevier Science Inc. All rights reserved.
Resumo:
A combination of modelling and analysis techniques was used to design a six component force balance. The balance was designed specifically for the measurement of impulsive aerodynamic forces and moments characteristic of hypervelocity shock tunnel testing using the stress wave force measurement technique. Aerodynamic modelling was used to estimate the magnitude and distribution of forces and finite element modelling to determine the mechanical response of proposed balance designs. Simulation of balance performance was based on aerodynamic loads and mechanical responses using convolution techniques. Deconvolution was then used to assess balance performance and to guide further design modifications leading to the final balance design. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
Tracking the reaction history is the means of choice to identify bioactive compounds in large combinatorial libraries. The authors describe two approaches to synthesis on silica beads: a) addition of a reporter dye tag during each synthesis step (see Figure), which attaches itself to the bead by colloidal forces, and b) encapsulating arrays of fluorescent dyes into the beads to encode them uniquely, for recognition with a flow cytometer after each reaction step.
Resumo:
The susceptibility of species of lutjanid, lethrinid and serranid fish to infection by either larval or post-larval (juvenile and adult) specimens of the capsalid monogenean Benedenia lutjani Whittington and Kearn (1993) was examined experimentally. Four species of lutjanids became infected when exposed to larvae of B. lutjani, but three species of lethrinids and four species of serranids were not susceptible to larvae under the same conditions. Variability in the intensity of infection by larvae occurred within and between lutjanid species. Few post-larval specimens of B. lutjani transferred between individuals of the specific host Lutjanus carponotatus (Richardson 1842) in 60-l aquaria and none transferred between specimens of L. carponotatus in a 7,500-l concrete tank. These results indicate that transfer of post-larval B. lutjani between individuals of the specific host is unlikely to occur in the wild. Other lutjanid species did not become infected when exposed to specimens of L. carponotatus infected heavily by post-larval B. lutjani, but two lethrinid species were susceptible to infection under the same conditions. These data indicate that different factors may mediate host-specificity for larval and post-larval B. lutjani.
Resumo:
A survey (N= 352) was conducted among British passengers of a cross-channel ferry. The survey aimed to test hypotheses drawn from Realistic Group Conflict, Social Identity and Contact theories using mainly a correlational design. However, an intervention by members of the outgroup (French fishermen blockading a port) also allowed a quasi-experimental test of the effects of a direct experience of intergroup conflict. Results supported the hypotheses since conflict and national identification were associated with more negative and with less positive attitudes toward the outgroup, while contact had the reverse effects. In addition, the salience of group membership in the contact relationship weakly moderated the effect of contact.
Resumo:
To obtain methotrexate (MTX) derivatives with a balanced hydrolipophilic character, we synthesized a series of conjugates in which the drug was linked to lipoamino acid (LAA)-glucose residues (LAAG-MTX). These conjugates displayed increased solubility in polar media compared with the corresponding LAA-MTX conjugates previously described. In vitro biological testing of LAAG-MTX indicated that the introduction of the sugar moiety decreased the biological activity of these MTX conjugates. The tetradecyl derivative 6b, however, was effective in inhibiting the dihydrofolate reductase activity in vitro and showed an inhibitory effect on human lymphoblastoid cell growth. (C) 2001 Wiley-Liss, Inc.
Resumo:
Objective: To assess the appropriateness of ipratropium bromide prescribing in two tertiary referral hospitals. Method: Criteria for optimal use were developed based on current literature and modified after consultation with respiratory physicians and clinical pharmacists. A prospective review of prescribing was performed over a 2-month period to assess conformity to these criteria. Results: Information was collected from 84 patients; 5% were receiving inhalers and 96% nebuliser therapy (one patient used both). 77% of patients (n = 65) had a principal diagnosis of chronic obstructive pulmonary disease, 14% (n = 12) asthma and 8% (n = 7) had neither diagnosis. 75% of patients were using ipratropium outside the guidelines. The major areas where the guidelines were not met were a lack of therapeutic justification, use of inappropriate doses, and use of an inappropriate delivery device. Feedback and educational interventions were designed and delivered based on the data obtained. Conclusions: There was widespread use of ipratropium outside the developed guidelines. Interventions in specific areas could lead to significant improvements in the use of this high cost drug