920 resultados para Sensitivity analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The aim of this work was to verify the differentiation between normal and pathological human carotid artery tissues by using fluorescence and reflectance spectroscopy in the 400- to 700-nm range and the spectral characterization by means of principal components analysis. Background Data: Atherosclerosis is the most common and serious pathology of the cardiovascular system. Principal components represent the main spectral characteristics that occur within the spectral data and could be used for tissue classification. Materials and Methods: Sixty postmortem carotid artery fragments (26 non-atherosclerotic and 34 atherosclerotic with non-calcified plaques) were studied. The excitation radiation consisted of a 488-nm argon laser. Two 600-mu m core optical fibers were used, one for excitation and one to collect the fluorescence radiation from the samples. The reflectance system was composed of a halogen lamp coupled to an excitation fiber positioned in one of the ports of an integrating sphere that delivered 5 mW to the sample. The photo-reflectance signal was coupled to a 1/4-m spectrograph via an optical fiber. Euclidean distance was then used to classify each principal component score into one of two classes, normal and atherosclerotic tissue, for both fluorescence and reflectance. Results: The principal components analysis allowed classification of the samples with 81% sensitivity and 88% specificity for fluorescence, and 81% sensitivity and 91% specificity for reflectance. Conclusions: Our results showed that principal components analysis could be applied to differentiate between normal and atherosclerotic tissue with high sensitivity and specificity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To evaluate the intratumoral reliability of color Doppler parameters and the contribution of Doppler sonography to the gray-scale differential diagnosis of ovarian masses. Methods: An observational study was performed including 67 patients, 15 (22.4%) with malignant ovarian neoplasm and 52 (77.6%) with benign ovarian diseases. We performed the Doppler evaluation in two distinct vessels selected after decreasing the Doppler gain to sample only vessels with higher velocity flow. Doppler measurements were obtained from each identified vessel, and resistive index (RI), pulsatility index (PI), peak systolic velocity (PSV), and end-diastolic velocity (EDV) were measured. Intraclass coefficient of correlation (ICC), sensitivity, specificity, and potential improvement in gray-scale ultrasound performance were calculated. Results: The general ICC were 0.60 (95% CI 0.42- 0.73) for RI, 0.65 (95% CI 0.49- 0.77) for PI, 0.07 (95% CI- 0.17-0.30) for PSV, and 0.19 (95% CI -0.05-0.41) for EDV. The sensitivity and specificity were respectively 84.6% and 86.7% for RI, 69.2% and 93.3% for PI, 80.0% and 65.4% for gray-scale sonography, and 93.3% and 65.4% for gray-scale plus RI (p = 0.013). Conclusions: Gynecologists must be careful in interpreting results from Doppler evaluation of ovarian masses because PSV and EDV present poor intratumoral reliability. The lower RI value, evaluated in at least two distinct sites of the tumor, was able to improve the performance of gray-scale ultrasound in differential diagnosis of ovarian masses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Tuberculosis is one of the most prominent health problems in the world, causing 1.75 million deaths each year. Rapid clinical diagnosis is important in patients who have comorbidities such as Human Immunodeficiency Virus (HIV) infection. Direct microscopy has low sensitivity and culture takes 3 to 6 weeks [1-3]. Therefore, new tools for TB diagnosis are necessary, especially in health settings with a high prevalence of HIV/TB co-infection. Methods: In a public reference TB/HIV hospital in Brazil, we compared the cost-effectiveness of diagnostic strategies for diagnosis of pulmonary TB: Acid fast bacilli smear microscopy by Ziehl-Neelsen staining (AFB smear) plus culture and AFB smear plus colorimetric test (PCR dot-blot). From May 2003 to May 2004, sputum was collected consecutively from PTB suspects attending the Parthenon Reference Hospital. Sputum samples were examined by AFB smear, culture, and PCR dot-blot. The gold standard was a positive culture combined with the definition of clinical PTB. Cost analysis included health services and patient costs. Results: The AFB smear plus PCR dot-blot require the lowest laboratory investment for equipment (US$ 20,000). The total screening costs are 3.8 times for AFB smear plus culture versus for AFB smear plus PCR dot blot costs (US$ 5,635,760 versus US$ 1,498, 660). Costs per correctly diagnosed case were US$ 50,773 and US$ 13,749 for AFB smear plus culture and AFB smear plus PCR dot-blot, respectively. AFB smear plus PCR dot-blot was more cost-effective than AFB smear plus culture, when the cost of treating all correctly diagnosed cases was considered. The cost of returning patients, which are not treated due to a negative result, to the health service, was higher in AFB smear plus culture than for AFB smear plus PCR dot-blot, US$ 374,778,045 and US$ 110,849,055, respectively. Conclusion: AFB smear associated with PCR dot-blot associated has the potential to be a cost-effective tool in the fight against PTB for patients attended in the TB/HIV reference hospital.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Esophageal ulcer (EU) represents an important comorbidity in AIDS. We evaluated the prevalence of EU, the accuracy of the endoscopic and histologic methods used to investigate viral EU in HIV-positive Brazilian patients and the numerical relevance of tissue sampling. A total of 399 HIV-positive patients underwent upper gastrointestinal (UGI) endoscopy. HIV-positive patients with EU determined by UGI endoscopy followed by biopsies were analyzed by the hematoxylin-eosin (HE) and immunohistochemical (IH) methods. EU was detected in 41 patients (mean age, 39.2 years; 23 males), with a prevalence of 10.27%. The median CD4 count was 49 cells/mm(3) (range, 1-361 cells/mm(3)) and the viral load was 58,869 copies per milliliter (range, 50-77,3290 copies per milliliter). UGI endoscopy detected 29 of 41 EU suggestive of cytomegalovirus (CMV) infection and 7 of 41 indicating herpes simplex virus (HSV) infection. HE histology confirmed 4 of 29 ulcers induced by CMV, 2 of 7 induced by HSV, and 1 of 7 induced by HSV plus CMV. IH for CMV and HSV confirmed the HE findings and detected one additional CMV-induced case. UGI endoscopy showed 100% sensitivity and 15% specificity for the diagnosis of EU due to CMV or HSV compared to HE and IH. HE proved to be an adequate method for etiologic evaluation, with 87% sensitivity and 100% specificity compared to IH. The number of samples did not influence the etiologic evaluation. The data support the importance of IH as a complementary method for HE in the diagnosis of EU of viral etiology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Mites (Acari) have traditionally been treated as monophyletic, albeit composed of two major lineages: Acariformes and Parasitiformes. Yet recent studies based on morphology, molecular data, or combinations thereof, have increasingly drawn their monophyly into question. Furthermore, the usually basal (molecular) position of one or both mite lineages among the chelicerates is in conflict to their morphology, and to the widely accepted view that mites are close relatives of Ricinulei. Results: The phylogenetic position of the acariform mites is examined through employing SSU, partial LSU sequences, and morphology from 91 chelicerate extant terminals (forty Acariformes). In a static homology framework, molecular sequences were aligned using their secondary structure as guide, whereby regions of ambiguous alignment were discarded, and pre-aligned sequences analyzed under parsimony and different mixed models in a Bayesian inference. Parsimony and Bayesian analyses led to trees largely congruent concerning infraordinal, well-supported branches, but with low support for inter-ordinal relationships. An exception is Solifugae + Acariformes (P. P = 100%, J. = 0.91). In a dynamic homology framework, two analyses were run: a standard POY analysis and an analysis constrained by secondary structure. Both analyses led to largely congruent trees; supporting a (Palpigradi (Solifugae Acariformes)) clade and Ricinulei as sister group of Tetrapulmonata with the topology (Ricinulei (Amblypygi (Uropygi Araneae))). Combined analysis with two different morphological data matrices were run in order to evaluate the impact of constraining the analysis on the recovered topology when employing secondary structure as a guide for homology establishment. The constrained combined analysis yielded two topologies similar to the exclusively molecular analysis for both morphological matrices, except for the recovery of Pedipalpi instead of the (Uropygi Araneae) clade. The standard (direct optimization) POY analysis, however, led to the recovery of trees differing in the absence of the otherwise well-supported group Solifugae + Acariformes. Conclusions: Previous studies combining ribosomal sequences and morphology often recovered topologies similar to purely morphological analyses of Chelicerata. The apparent stability of certain clades not recovered here, like Haplocnemata and Acari, is regarded as a byproduct of the way the molecular homology was previously established using the instrumentalist approach implemented in POY. Constraining the analysis by a priori homology assessment is defended here as a way of maintaining the severity of the test when adding new data to the analysis. Although the strength of the method advocated here is keeping phylogenetic information from regions usually discarded in an exclusively static homology framework; it still has the inconvenience of being uninformative on the effect of alignment ambiguity on resampling methods of clade support estimation. Finally, putative morphological apomorphies of Solifugae + Acariformes are the reduction of the proximal cheliceral podomere, medial abutting of the leg coxae, loss of sperm nuclear membrane, and presence of differentiated germinative and secretory regions in the testis delivering their products into a common lumen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Using the published KTeV samples of K(L) -> pi(+/-)e(-/+)nu and K(L) -> pi(+/-)mu(-/+)nu decays, we perform a reanalysis of the scalar and vector form factors based on the dispersive parametrization. We obtain phase-space integrals I(K)(e) = 0.15446 +/- 0.00025 and I(K)(mu) = 0.10219 +/- 0.00025. For the scalar form factor parametrization, the only free parameter is the normalized form factor value at the Callan-Treiman point (C); our best-fit results in InC = 0.1915 +/- 0.0122. We also study the sensitivity of C to different parametrizations of the vector form factor. The results for the phase-space integrals and C are then used to make tests of the standard model. Finally, we compare our results with lattice QCD calculations of F(K)/F(pi) and f(+)(0).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes the coupling of a biomimetic sensor to a flow injection system for the sensitive determination of paracetamol. The sensor was prepared as previously described in the literature (M. D. P. T. Sotomayor, A. Sigoli, M. R. V. Lanza, A. A. Tanaka and L. T. Kubota, J. Braz. Chem. Soc., 2008, 19, 734) by modifying a glassy carbon electrode surface with a Nafion (R) membrane doped with iron tetrapyridinoporphyrazine (FeTPyPz), a biomimetic catalyst of the P450 enzyme. The performance of the sensor for paracetamol detection was investigated and optimized in a flow injection system (FIA) using a wall jet electrochemical cell. Under optimized conditions a wide linear response range (1.0 x 10(-5) to 5.0 x 10(-2) mol L(-1)) was obtained, with a sensitivity of 2579 (+/- 129) mu A L mu mol(-1). The detection and quantification limits of the sensor for paracetamol in the FIA system were 1.0 and 3.5 mu mol L(-1), respectively. The analytical frequency was 51 samples h(-1), and over a period of five days (320 determinations) the biosensor maintained practically the same response. The system was successfully applied to paracetamol quantification in seven pharmaceutical formulations and in water samples from six rivers in Sao Paulo State, Brazil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A green and highly sensitive analytical procedure was developed for the determination of free chlorine in natural waters, based on the reaction with N,N-diethyl-p-phenylenediamine (DPD). The flow system was designed with solenoid micro-pumps in order to improve mixing conditions by pulsed flows and to minimize reagent consumption as well as waste generation. A 100-cm optical path flow cell based on a liquid core waveguide was employed to increase sensitivity. A linear response was observed within the range 10.0 to 100.0 mu g L(-1), with the detection limit, coefficient of variation and sampling rate estimated as 6.8 mu g (99.7% confidence level), 0.9% (n = 20) and 60 determinations per hour, respectively. The consumption of the most toxic reagent (DPD) was reduced 20,000-fold and 30-fold in comparison to the batch method and flow injection with continuous reagent addition, respectively. The results for natural and tap water samples agreed with those obtained by the reference batch spectrophotometric procedure at the 95% confidence level. (C) 2010 Elsevier By. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A fully automated multipumping flow system (MPFS) using water-soluble CdTe quantum dots (QD) as sensitizers is proposed for the chemiluminometric determination of the anti-diabetic drugs gliclazide and glipizide in pharmaceutical formulations. The nanocrystals acted as enhancers of the weak CL emission produced upon oxidation of sulphite by Ce(IV) in acidic medium, thus improving sensitivity and expanding the dynamical analytical concentration range. By interacting with the QD, the two analytes prevented their sensitizing effect yielding a chemiluminescence quenching of the Ce(IV)-SO(3)(2-)CdTe QD system. The pulsed flow inherent to MPFS assured a fast and efficient mixing of all solutions inside the flow cell, circumventing the need for a reaction coil and facilitating the monitoring of the short-lived generated chemiluminescent species. QD crystal size, concentration and spectral region for measurement were investigated. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper a new boundary element method formulation for elastoplastic analysis of plates with geometrical nonlinearities is presented. The von Mises criterion with linear isotropic hardening is considered to evaluate the plastic zone. Large deflections are assumed but within the context of small strain. To derive the boundary integral equations the von Karman`s hypothesis is taken into account. An initial stress field is applied to correct the true stresses according to the adopted criterion. Isoparametric linear elements are used to approximate the boundary unknown values while triangular internal cells with linear shape function are adopted to evaluate the domain value influences. The nonlinear system of equations is solved by using an implicit scheme together with the consistent tangent operator derived along the paper. Numerical examples are presented to demonstrate the accuracy and the validity of the proposed formulation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Void fraction sensors are important instruments not only for monitoring two-phase flow, but for furnishing an important parameter for obtaining flow map pattern and two-phase flow heat transfer coefficient as well. This work presents the experimental results obtained with the analysis of two axially spaced multiple-electrode impedance sensors tested in an upward air-water two-phase flow in a vertical tube for void fraction measurements. An electronic circuit was developed for signal generation and post-treatment of each sensor signal. By phase shifting the electrodes supplying the signal, it was possible to establish a rotating electric field sweeping across the test section. The fundamental principle of using a multiple-electrode configuration is based on reducing signal sensitivity to the non-uniform cross-section void fraction distribution problem. Static calibration curves were obtained for both sensors, and dynamic signal analyses for bubbly, slug, and turbulent churn flows were carried out. Flow parameters such as Taylor bubble velocity and length were obtained by using cross-correlation techniques. As an application of the void fraction tested, vertical flow pattern identification could be established by using the probability density function technique for void fractions ranging from 0% to nearly 70%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple theoretical framework is presented for bioassay studies using three component in vitro systems. An equilibrium model is used to derive equations useful for predicting changes in biological response after addition of hormone-binding-protein or as a consequence of increased hormone affinity. Sets of possible solutions for receptor occupancy and binding protein occupancy are found for typical values of receptor and binding protein affinity constants. Unique equilibrium solutions are dictated by the initial condition of total hormone concentration. According to the occupancy theory of drug action, increasing the affinity of a hormone for its receptor will result in a proportional increase in biological potency. However, the three component model predicts that the magnitude of increase in biological potency will be a small fraction of the proportional increase in affinity. With typical initial conditions a two-fold increase in hormone affinity for its receptor is predicted to result in only a 33% increase in biological response. Under the same conditions an Ii-fold increase in hormone affinity for receptor would be needed to produce a two-fold increase in biological potency. Some currently used bioassay systems may be unrecognized three component systems and gross errors in biopotency estimates will result if the effect of binding protein is not calculated. An algorithm derived from the three component model is used to predict changes in biological response after addition of binding protein to in vitro systems. The algorithm is tested by application to a published data set from an experimental study in an in vitro system (Lim et al., 1990, Endocrinology 127, 1287-1291). Predicted changes show good agreement (within 8%) with experimental observations. (C) 1998 Academic Press Limited.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The gamma-aminobutyric acid type A (GABA(A)) receptor mediates fast inhibitory synaptic transmission in the CNS. Dysfunction of the GABA(A) receptor would be expected to cause neuronal hyperexcitability, a phenomenon linked with epileptogenesis. We have investigated the functional consequences of an arginine-to-glutamine mutation at position 43 within the GABA(A) gamma(2)-subunit found in a family with childhood absence epilepsy and febrile seizures. Rapid-application experiments performed on receptors expressed in HEK-293 cells demonstrated that the mutation slows GABA(A) receptor deactivation and increases the rate of desensitization, resulting in an accumulation of desensitized receptors during repeated, short applications. In Xenopus laevis oocytes, two-electrode voltage-clamp analysis of steady-state currents obtained from alpha(1)beta(2)gamma(2) or alpha(1)beta(2)gamma(2)(R43Q) receptors did not reveal any differences in GABA sensitivity. However, differences in the benzodiazepine pharmacology of mutant receptors were apparent. Mutant receptors expressed in oocytes displayed reduced sensitivity to diazepam and flunitrazepam but not the imiclazopyricline zolpidem. These results provide evidence of impaired GABA(A) receptor function that could decrease the efficacy of transmission at inhibitory synapses, possibly generating a hyperexcitable neuronal state in thalamocortical networks of epileptic patients possessing the mutant subunit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Obesity affects aspects of glucose homeostasis such as insulin secretion and insulin sensitivity. Hormones secreted by adipocytes like leptin mediate the metabolic consequences of obesity. Incretin hormones like glucagon-like peptide-1 (GLP-1) increase insulin secretion in response to changes in blood glucose concentration and have been proposed to regulate insulin secretion in fasting, overweight dogs. The aim of this study was to examine hormonal mechanisms by which adiposity alters glucose homeostasis, plasma insulin concentration, and insulin sensitivity in spontaneously overweight dogs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Capillary C4d deposition has been recognized as a marker of antibody-mediated rejection (AMR). Although the detection of capillary C4d by means of immunofluorescence (IF) in cryostat sections is well established, frozen tissue is not always available, thus limiting the diagnosis of AMR. The aim of the present study was to analyze different techniques for C4d staining and the prevalence of C4d in renal allograft biopsies. Detection of C4d was carried out using IF or immunohistochemistry (IHC) on frozen and paraffin sections of renal allograft biopsies available from the same patients. Biopsies obtained from 20 patients were classified into 3 groups: no rejection, acute rejection, and chronic allograft nephropathy (CAN). The capillary C4d deposition prevalence in frozen-IF, considered the gold standard technique for C4d detection, was 45% (9/20 cases). Compared with frozen-IF, the frozen-IHC technique presented an 85% concordance rate (17/20 cases; r =.70; P <.001; sensitivity = 77.8%; specificity = 90.9%). The paraffin-IF technique showed similar results, with an 80% concordance rate (16/20 cases; r =.64; P <.005; sensitivity = 55.6%; specificity = 100%), whereas C4d detection occurred in only 65% of paraffin-IHC cases (13/20; r =.30; not significant; sensitivity = 66.7%; specificity = 63.6%). No capillary C4d deposition was detected in cases without evidence of rejection. However, 4/7 cases (57%) of acute rejection were C4d positive. In the CAN group, 5111 cases (45%) were C4d positive. In conclusion, these results demonstrated that frozen-IHC and paraffin-IF can be considered alternative techniques to frozen-IF for C4d detection. The paraffin-IHC technique displayed the lowest concordance rate for C4d detection.