Background The onsite treatment of sewage and effluent disposal within the premises is widely prevalent in rural and urban fringe areas due to the general unavailability of reticulated wastewater collection systems. Despite the seemingly low technology of the systems, failure is common and in many cases leading to adverse public health and environmental consequences. Therefore it is important that careful consideration is given to the design and location of onsite sewage treatment systems. It requires an understanding of the factors that influence treatment performance. The use of subsurface effluent absorption systems is the most common form of effluent disposal for onsite sewage treatment and particularly for septic tanks. Additionally in the case of septic tanks, a subsurface disposal system is generally an integral component of the sewage treatment process. Therefore location specific factors will play a key role in this context. The project The primary aims of the research project are: • to relate treatment performance of onsite sewage treatment systems to soil conditions at site; • to identify important areas where there is currently a lack of relevant research knowledge and is in need of further investigation. These tasks were undertaken with the objective of facilitating the development of performance based planning and management strategies for onsite sewage treatment. The primary focus of the research project has been on septic tanks. Therefore by implication the investigation has been confined to subsurface soil absorption systems. The design and treatment processes taking place within the septic tank chamber itself did not form a part of the investigation. In the evaluation to be undertaken, the treatment performance of soil absorption systems will be related to the physico-chemical characteristics of the soil. Five broad categories of soil types have been considered for this purpose. The number of systems investigated was based on the proportionate area of urban development within the Brisbane region located on each soil types. In the initial phase of the investigation, though the majority of the systems evaluated were septic tanks, a small number of aerobic wastewater treatment systems (AWTS) were also included. This was primarily to compare the effluent quality of systems employing different generic treatment processes. It is important to note that the number of different types of systems investigated was relatively small. As such this does not permit a statistical analysis to be undertaken of the results obtained. This is an important issue considering the large number of parameters that can influence treatment performance and their wide variability. The report This report is the second in a series of three reports focussing on the performance evaluation of onsite treatment of sewage. The research project was initiated at the request of the Brisbane City Council. The work undertaken included site investigation and testing of sewage effluent and soil samples taken at distances of 1 and 3 m from the effluent disposal area. The project component discussed in the current report formed the basis for the more detailed investigation undertaken subsequently. The outcomes from the initial studies have been discussed, which enabled the identification of factors to be investigated further. Primarily, this report contains the results of the field monitoring program, the initial analysis undertaken and preliminary conclusions. Field study and outcomes Initially commencing with a list of 252 locations in 17 different suburbs, a total of 22 sites in 21 different locations were monitored. These sites were selected based on predetermined criteria. To obtain house owner agreement to participate in the monitoring study was not an easy task. Six of these sites had to be abandoned subsequently due to various reasons. The remaining sites included eight septic systems with subsurface effluent disposal and treating blackwater or combined black and greywater, two sites treating greywater only and six sites with AWTS. In addition to collecting effluent and soil samples from each site, a detailed field investigation including a series of house owner interviews were also undertaken. Significant observations were made during the field investigations. In addition to site specific observations, the general observations include the following: • Most house owners are unaware of the need for regular maintenance. Sludge removal has not been undertaken in any of the septic tanks monitored. Even in the case of aerated wastewater treatment systems, the regular inspections by the supplier is confined only to the treatment system and does not include the effluent disposal system. This is not a satisfactory situation as the investigations revealed. • In the case of separate greywater systems, only one site had a suitably functioning disposal arrangement. The general practice is to employ a garden hose to siphon the greywater for use in surface irrigation of the garden. • In most sites, the soil profile showed significant lateral percolation of effluent. As such, the flow of effluent to surface water bodies is a distinct possibility. • The need to investigate the subsurface condition to a depth greater than what is required for the standard percolation test was clearly evident. On occasion, seemingly permeable soil was found to have an underlying impermeable soil layer or vice versa. The important outcomes from the testing program include the following: • Though effluent treatment is influenced by the physico-chemical characteristics of the soil, it was not possible to distinguish between the treatment performance of different soil types. This leads to the hypothesis that effluent renovation is significantly influenced by the combination of various physico-chemical parameters rather than single parameters. This would make the processes involved strongly site specific. • Generally the improvement in effluent quality appears to take place only within the initial 1 m of travel and without any appreciable improvement thereafter. This relates only to the degree of improvement obtained and does not imply that this quality is satisfactory. This calls into question the value of adopting setback distances from sensitive water bodies. • Use of AWTS for sewage treatment may provide effluent of higher quality suitable for surface disposal. However on the whole, after a 1-3 m of travel through the subsurface, it was not possible to distinguish any significant differences in quality between those originating from septic tanks and AWTS. • In comparison with effluent quality from a conventional wastewater treatment plant, most systems were found to perform satisfactorily with regards to Total Nitrogen. The success rate was much lower in the case of faecal coliforms. However it is important to note that five of the systems exhibited problems with regards to effluent disposal, resulting in surface flow. This could lead to possible contamination of surface water courses. • The ratio of TDS to EC is about 0.42 whilst the optimum recommended value for use of treated effluent for irrigation should be about 0.64. This would mean a higher salt content in the effluent than what is advisable for use in irrigation. A consequence of this would be the accumulation of salts to a concentration harmful to crops or the landscape unless adequate leaching is present. These relatively high EC values are present even in the case of AWTS where surface irrigation of effluent is being undertaken. However it is important to note that this is not an artefact of the treatment process but rather an indication of the quality of the wastewater generated in the household. This clearly indicates the need for further research to evaluate the suitability of various soil types for the surface irrigation of effluent where the TDS/EC ratio is less than 0.64. • Effluent percolating through the subsurface absorption field may travel in the form of dilute pulses. As such the effluent will move through the soil profile forming fronts of elevated parameter levels. • The downward flow of effluent and leaching of the soil profile is evident in the case of podsolic, lithosol and kransozem soils. Lateral flow of effluent is evident in the case of prairie soils. Gleyed podsolic soils indicate poor drainage and ponding of effluent. In the current phase of the research project, a number of chemical indicators such as EC, pH and chloride concentration were employed as indicators to investigate the extent of effluent flow and to understand how soil renovates effluent. The soil profile, especially texture, structure and moisture regime was examined more in an engineering sense to determine the effect of movement of water into and through the soil. However it is not only the physical characteristics, but the chemical characteristics of the soil also play a key role in the effluent renovation process. Therefore in order to understand the complex processes taking place in a subsurface effluent disposal area, it is important that the identified influential parameters are evaluated using soil chemical concepts. Consequently the primary focus of the next phase of the research project will be to identify linkages between various important parameters. The research thus envisaged will help to develop robust criteria for evaluating the performance of subsurface disposal systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The onsite treatment of sewage and effluent disposal is widely prevalent in rural and urban fringe areas due to the general unavailability of reticulated wastewater collection systems. Despite the low technology of the systems, failure is common and in many cases leading to adverse public health and environmental consequences. It is important therefore that careful consideration is given to the design and location of onsite sewage treatment systems. This requires an understanding of the factors that influence treatment performance. The use of subsurface absorption systems is the most common form of effluent disposal for onsite sewage treatment, particularly for septic tanks. Also, in the case of septic tanks, a subsurface disposal system is generally an integral component of the sewage treatment process. Site specific factors play a key role in the onsite treatment of sewage. The project The primary aims of the research project were: • to relate treatment performance of onsite sewage treatment systems to soil conditions at site; • to evaluate current research relating to onsite sewage treatment; and, • to identify key issues where currently there is a lack of relevant research. These tasks were undertaken with the objective of facilitating the development of performance based planning and management strategies for onsite sewage treatment. The primary focus of this research project has been on septic tanks. By implication, the investigation has been confined to subsurface soil absorption systems. The design and treatment processes taking place within the septic tank chamber itself did not form a part of the investigation. Five broad categories of soil types prevalent in the Brisbane region have been considered in this project. The number of systems investigated was based on the proportionate area of urban development within the Brisbane region located on each of the different soil types. In the initial phase of the investigation, the majority of the systems evaluated were septic tanks. However, a small number of aerobic wastewater treatment systems (AWTS) were also included. The primary aim was to compare the effluent quality of systems employing different generic treatment processes. It is important to note that the number of each different type of system investigated was relatively small. Consequently, this does not permit a statistical analysis to be undertaken of the results obtained for comparing different systems. This is an important issue considering the large number of soil physico-chemical parameters and landscape factors that can influence treatment performance and their wide variability. The report This report is the last in a series of three reports focussing on the performance evaluation of onsite treatment of sewage. The research project was initiated at the request of the Brisbane City Council. The project component discussed in the current report outlines the detailed soil investigations undertaken at a selected number of sites. In the initial field sampling, a number of soil chemical properties were assessed as indicators to investigate the extent of effluent flow and to help understand what soil factors renovate the applied effluent. The soil profile attributes, especially texture, structure and moisture regime were examined more in an engineering sense to determine the effect of movement of water into and through the soil. It is important to note that it is not only the physical characteristics, but also the chemical characteristics of the soil as well as landscape factors play a key role in the effluent renovation process. In order to understand the complex processes taking place in a subsurface effluent disposal area, influential parameters were identified using soil chemical concepts. Accordingly, the primary focus of this final phase of the research project was to identify linkages between various soil chemical parameters and landscape patterns and their contribution to the effluent renovation process. The research outcomes will contribute to the development of robust criteria for evaluating the performance of subsurface effluent disposal systems. The outcomes The key findings from the soil investigations undertaken are: • Effluent renovation is primarily undertaken by a combination of various soil physico-chemical parameters and landscape factors, thereby making the effluent renovation processes strongly site dependent. • Decisions regarding site suitability for effluent disposal should not be based purely in terms of the soil type. A number of other factors such as the site location in the catena, the drainage characteristics and other physical and chemical characteristics, also exert a strong influence on site suitability. • Sites, which are difficult to characterise in terms of suitability for effluent disposal, will require a detailed soil physical and chemical analysis to be undertaken to a minimum depth of at least 1.2 m. • The Ca:Mg ratio and Exchangeable Sodium Percentage are important parameters in soil suitability assessment. A Ca:Mg ratio of less than 0.5 would generally indicate a high ESP. This in turn would mean that Na and possibly Mg are the dominant exchangeable cations, leading to probable clay dispersion. • A Ca:Mg ratio greater than 0.5 would generally indicate a low ESP in the profile, which in turn indicates increased soil stability. • In higher clay percentage soils, low ESP can have a significant effect. • The presence of high exchangeable Na can be counteracted by the presence of swelling clays, and an exchange complex co-dominated by exchangeable Ca and exchangeable Mg. This aids absorption of cations at depth, thereby reducing the likelihood of dispersion. • Salt is continually added to the soil by the effluent and problems may arise if the added salts accumulate to a concentration that is harmful to the soil structure. Under such conditions, good drainage is essential in order to allow continuous movement of water and salt through the profile. Therefore, for a site to be sustainable, it would have a maximum application rate of effluent. This would be dependent on subsurface characteristics and the surface area available for effluent disposal. • The dosing regime for effluent disposal can play a significant role in the prevention of salt accumulation in the case of poorly draining sites. Though intermittent dosing was not considered satisfactory for the removal of the clogging mat layer, it has positive attributes in the context of removal of accumulated salts in the soil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The following summary report provides a concise overview of the research undertaken and the outcomes derived from the performance evaluation study of onsite sewage treatment systems. Additionally, a number of recommendations have been provided to enhance the treatment performance of these systems. This report also identifies a number of areas, which merit further investigations. The focus of the study was on subsurface effluent disposal systems. The reader is referred to the three project reports that were produced for more detailed information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There have been calls for Malaysian local authorities to be more transparent and accountable in the discharge of their functional responsibilities. This study empirically evaluates the extent and quality of current performance reporting by local authorities. The disclosure of relevant information for discharging accountability obligations, as defined by a broad range of stakeholders, falls short of best practice. Therefore, the performance of Malaysian local authorities lacks transparency. The findings could assist in the development of more comprehensive guidelines for local authority reporting and raise awareness of information stakeholders expect to be reported in the context of accountability

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Giant freshwater prawn (GFP; Macrobrachium rosenbergii) aquaculture has expanded rapidly since 1990. Most local culture industries, however, have developed in an unsystematic way. Fiji has a small culture industry producing the ‘Anuenue’ strain; however, performance of this strain has never been systematically evaluated. Recently, some Fijian farmers have reported declines in stock productivity. The current project evaluated the relative performance of three exotic strains with different genetic backgrounds from Malaysia, Indonesia and Vietnam, against the ‘local’ strain in Fiji in a 4 × 3 replicated pond trial experiment. A total of 5827 prawns were harvested after 143 days growout. Individual growth rate and relative survival of the Fiji strain were not statistically different from any of the introduced strains, but Vietnam strain was superior to that of the Malaysia strain. Genetic diversity showed significant differences in variability among strains, with the Malaysian strain displaying the lowest genetic diversity. Indonesia strain showed that females were reaching maturation earlier than other strains and were smaller in size. This study suggests that Malaysian and Indonesian strains would constitute a poor choice for Fiji, whereas the Vietnam strain consistently performed well on all criteria measured. High variation among replicate ponds within strains unfortunately confounded among-strain variation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During an intensive design-led workshop multidisciplinary design teams examined options for a sustainable multi-residential tower on an inner urban site in Brisbane (Australia). The main aim was to demonstrate the key principles of daylight to every habitable room and cross-ventilation to every apartment in the subtropical climate while responding to acceptable yield and price points. The four conceptual design proposals demonstrated a wide range of outcomes, with buildings ranging from 15 to 30 storeys. Daylight Factor (DF), view to the outside, and the avoidance of direct sunlight were the only quantitative and qualitative performance metrics used to implement daylighting to the proposed buildings during the charrette. This paper further assesses the daylighting performance of the four conceptual designs by utilizing Climate-based daylight modeling (CBDM), specifically Daylight Autonomy (DA) and Useful Daylight Illuminance (UDI). Results show that UDI 100-2000lux calculations provide more useful information on the daylighting design than DF. The percentage of the space with a UDI <100-2000lux larger than 50% ranged from 77% to 86% of the time for active occupant behaviour (occupancy from 6am to 6pm). The paper also highlights the architectural features that mostly affect daylighting design in subtropical climates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traditional shading design principles guide the vertical and horizontal orientation of fins, louvres and awnings being applied to orthogonal planar façades. Due to doubly curved envelopes characterising many contemporary designs, these rules of thumb are now not always applicable. Operable blinds attempt to regulate the fluctuating luminance of daylight and aid in shading direct sunlight. Mostly they remain closed, as workers are commonly too preoccupied to continually adjust them so a reliance on electrically powered lights remains a preference. To remedy these problems, the idea of what it is to sustainable enclose space is reconsidered through the geometric and kinetic optimisation of a parametric skin, with sunlight responsive modules that regulate interior light levels. This research concludes with an optimised design and also defines some unique metrics to gauge the design’s performance in terms of, the amount of exterior unobstructed view, its ability to shade direct sunlight and, its daylight glare probability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Management scholars and practitioners emphasize the importance of the size and diversity of a knowledge worker's social network. Constraints on knowledge workers’ time and energy suggest that more is not always better. Further, why and how larger networks contribute to valuable outcomes deserves further understanding. In this study, we offer hypotheses to shed insight on the question of the diminishing returns of large networks and the specific form of network diversity that may contribute to innovative performance among knowledge workers. We tested our hypotheses using data collected from 93 R&D engineers in a Sino-German automobile electronics company located in China. Study findings identified an inflection point, confirming our hypothesis that the size of the knowledge worker's egocentric network has an inverted U-shaped effect on job performance. We further demonstrate that network dispersion richness (the number of cohorts that the focal employee has connections to) rather than network dispersion evenness (equal distribution of ties across the cohorts) has more influence on the knowledge worker's job performance. Additionally, we found that the curvilinear effect of network size is fully mediated by network dispersion richness. Implications for future research on social networks in China and Western contexts are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies time integration methods for large stiff systems of ordinary differential equations (ODEs) of the form u'(t) = g(u(t)). For such problems, implicit methods generally outperform explicit methods, since the time step is usually less restricted by stability constraints. Recently, however, explicit so-called exponential integrators have become popular for stiff problems due to their favourable stability properties. These methods use matrix-vector products involving exponential-like functions of the Jacobian matrix, which can be approximated using Krylov subspace methods that require only matrix-vector products with the Jacobian. In this paper, we implement exponential integrators of second, third and fourth order and demonstrate that they are competitive with well-established approaches based on the backward differentiation formulas and a preconditioned Newton-Krylov solution strategy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A number of tests and test batteries are available for the prediction of older driver safety, but many of these have not been validated against standardized driving outcome measures. The aim of this study was to evaluate a series of previously described screening tests in terms of their ability to predict the potential for safe and unsafe driving. Participants included 79 community-dwelling older drivers (M=72.16 years, SD=5.46; range 65-88 years; 57 males and 22 females) who completed a previously validated multi-disciplinary driving assessment, a hazard perception test, a hazard change detection test and a battery of vision and cognitive tests. Participants also completed a standardized on-road driving assessment. The multi-disciplinary test battery had the highest predictive ability with a sensitivity of 80% and a specificity of 73%, followed by the hazard perception test which demonstrated a sensitivity of 75% and a specificity of 61%. These findings suggest that a relatively simple and practical battery of tests from a range of domains has the capacity to predict safe and unsafe driving in older adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The traditional model of visual arts practice is one that privileges highly individuated reflection and research on studio based, predominately material outcomes. This archetypal approach to thinking about cultural production tends to overlook all of the conceptual and contextual collaborations that take place, both informally and formally in the process of making artworks. The aim of this practice-led research project is to creatively and critically explore the potential for actively engaging in a collaborative process for making artworks. It will focus on this approach to research and making through performance and video based works made in conjunction with Kate Woodcroft. Through doing this it aims to explore the possibilities for thinking and working beyond singular, materially based practices and develop new understandings for this as a model for generating new and unexpected creative outcomes. Key departure points for this discussion include; tertiary performance, conceptual art, and humour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The traditional model of visual arts practice is one that privileges highly individuated and predominantly material investigations and outcomes. This approach overlooks and devalues the formal and informal dialogues and collaborations that take place in the process of making art. This Masters research project considers how the experience of working in collaboration can generate a new model for thinking about practice-led methodologies in visual arts. It aims to do this by mapping out and elaborating on the processes and approaches to making that fellow Masters student Catherine Sagin and I have come to use in our alliance as ‘Fiona Mail’, ‘Catherine Sagin’ and ‘Catherine or Kate’ respectively. The fluidity of our collaborative moniker is one example of the way this project creatively explores and re-assesses the implications of collaboration. Drawing upon the contextual frames of conceptual art, performance art, and comedy this research looks at the significance of and possibilities for working as a collaborative duo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: There is a lack of theory relating to destination brand performance measurement in the destination branding literature, which emerged in the late 1990s (see for example Dosen, Vransevic, & Prebezac, 1998). Additionally, there is a lack of research about the importance of travel context in consumers’ destination decision making (Hu & Ritchie, 1993). This study develops a structural model to measure destination brand performance across different travel situations. The theory of planned behaviour (TpB) was utilised as a framework to underpin the consumer-based brand equity (CBBE) hierarchy to develop a model of destination brand performance. Research approach: A proposed model of destination brand performance was developed through a review of the literature. The first study was used to identify destination image attributes (the core construct) using an analysis of the literature, a document analysis, and personal interviews using the Repertory Test qualitative technique. Underpinned by Personal Construct Theory (PCT), the Repertory Test enables the elicitation of attributes consumers use to evaluate destinations when considering travel. Data was examined in the first study to i) identify any attribute differences in travel contexts and ii) create a scale for use in a questionnaire. A second study was conducted to test the proposed model using a questionnaire with eight groups of participants to assess four destinations across two travel contexts. The model was tested utilising structural equation modelling. Findings: The first study resulted in a list of 29 destination image attributes for use in a scale index. Attributes were assessed across travel contexts and few differences were identified. The second study assessed the congruence of destination brand identity (the destination marketing organisation’s desired image) and destination brand image (the actual perceptions held by consumers) using importance-performance analyses. Finally, the proposed model of destination brand performance was tested. Overall the data supported the model of destination brand performance across travel contexts and destinations. Additionally, this was compared to consumers’ decision sets, further supporting the model. Value: This research provides a contribution to the destination marketing literature through the development of a measurement of destination brand performance underpinned by TpB. Practically; it will provide destination marketing organisations with a tool to track destination brand performance, relative to key competing places, over time. This is important given the development of a destination brand is a long term endeavour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the effect of engine backpressure on the performance and emissions of a CI engine under different speed and load conditions. A 4-stroke single cylinder naturally aspirated direct injection (DI) diesel engine was used for the investigation with the backpressure of 0, 40, 60 and 80 mm of Hg at engine speed of 600, 950 and 1200 rpm. Two parameters were measured during the engine operation: one is engine performance (brake thermal efficiency and brake specific fuel consumption), and the other is the exhaust emissions (NOx, CO and odor). NOx and CO emission were measured by flue gas analyzer (IMR 1400). The engine backpressure produced by the flow regulating valve in the exhaust line was measured by Hg (mercury) manometer. The result showed that, the brake thermal efficiency and brake specific fuel consumption (bsfc) are almost unchanged with increasing backpressure up to 40 mm of Hg pressure for all engine speed and load conditions. The NOx emission became constant or a little decreased with increasing backpressure. The formation of CO was slightly higher with increase of load and back pressure at low engine speed condition. However, under high speed conditions, CO reduced significantly with increasing backpressure for all load conditions. The odor level was similar or a little higher with increasing backpressure for all engine speed and load conditions. Hence, backpressure up to a certain level is not detrimental for a CI engine.