845 resultados para Potência de membros inferiores


Relevância:

20.00% 20.00%

Publicador:

Resumo:

About 10% of faults involving the electrical system occurs in power transformers. Therefore, the protection applied to the power transformers is essential to ensure the continuous operation of this device and the efficiency of the electrical system. Among the protection functions applied to power transformers, the differential protection appears as one of the main schemes, presenting reliable discrimination between internal faults and external faults or inrush currents. However, when using the low frequency components of the differential currents flowing through the transformer, the main difficulty of the conventional methods of differential protection is the delay for detection of the events. However, internal faults, external faults and other disturbances related to the transformer operation present transient and can be appropriately detected by the wavelet transform. In this paper is proposed the development of a wavelet-based differential protection for detection and identification of external faults to the transformer, internal faults, and transformer energizing by using the wavelet coefficient energy of the differential currents. The obtained results reveal the advantages of using of the wavelet transform in the differential protection compared to conventional protection, since it provides reliability and speed in detection of these events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the drilling of oil and natural gas are generated solid waste, liquid and gaseous. These solid fragments, which are known as cuttings, are carried to the surface through the drilling fluid. Furthermore, this fluid serves to cool the bit, keeping the internal pressure of the well, and others. This solid residue is very polluting, because it has incorporated beyond the drilling fluid, which has several chemical additives harmful to the environment, some heavy metals that are harmful to the environment, such as lead. To minimize the residue generated, are currently being studied numerous techniques to mitigate the problems that such waste can cause to the environment, like addition of cuttings in the composition of soil cement brick masonry construction, addition of cuttings on the clay matrix for the manufacture of solid masonry bricks and ceramic blocks and coprocessing of the cuttings in cement. So, the main objective of this work is the incorporation of cuttings drilling of oil wells, the cement slurry used in the cementing operation of the well. This cuttings used in this study, arising from the formation Pendências, was milled and separated in a sieve of 100 mesh. After grinding had a mean particle sike in order of 86 mm and crystal structure containing phases of quartz and calcite type, characteristic of the Portland cement. Were formulated and prepared slurries of cement with density 13 lb / gal, containing different concentrations of gravel, and realized characterization tests API SPEC 10A and RP 10B. Free water tests showed values lower than 5.9% and the rheological model that best described the behavior of the mixtures was the power. The results of compressive strength (10.3 MPa) and stability (Dr <0.5 lb / gal) had values within the set of operational procedures. Thus, the gravel from the drilling operation, may be used as binders in addition to Portland cement oil wells, in order to reuse this waste and reduce the cost of the cement paste.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conventional control schemes applied to Shunt Active Power Filters (SAPF) are Harmonic extractor-based strategies (HEBSs) because their effectiveness depends on how quickly and accurately the harmonic components of the nonlinear loads are identified. The SAPF can be also implemented without the use of the load harmonic extractors. In this case, the harmonic compensating term is obtained from the system active power balance. These systems can be considered as balanced-energy-based schemes (BEBSs) and their performance depends on how fast the system reaches the equilibrium state. In this case, the phase currents of the power grid are indirectly regulated by double sequence controllers with two degrees of freedom, where the internal model principle is employed to avoid reference frame transformation. Additionally the DSC controller presents robustness when the SAPF is operating under unbalanced conditions. Furthermore, SAPF implemented without harmonic detection schemes compensate simultaneously harmonic distortion and reactive power of the load. Their compensation capabilities, however, are limited by the SAPF power converter rating. Such a restriction can be minimized if the level of the reactive power correction is managed. In this work an estimation scheme for determining the filter currents is introduced to manage the compensation of reactive power. Experimental results are shown for demonstrating the performance of the proposed SAPF system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of the power monitoring in electrical power systems is to promote the reliablility as well as the quality of electrical power.Therefore, this dissertation proposes a new theory of power based on wavelet transform for real-time estimation of RMS voltages and currents, and some power amounts, such as active power, reactive power, apparent power, and power factor. The appropriate estimation the of RMS and power values is important for many applications, such as: design and analysis of power systems, compensation devices for improving power quality, and instruments for energy measuring. Simulation and experimental results obtained through the proposed MaximalOverlap Discrete Wavelet Transform-based method were compared with the IEEE Standard 1459-2010 and the commercial oscilloscope, respectively, presenting equivalent results. The proposed method presented good performance for compact mother wavelet, which is in accordance with real-time applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical disturbances such as voltage sags, interruptions and voltage unbalances might cause serious problems for the end-user and for the companies of generation and transmission of energy. Few years ago, those companies have been using methods and equipments of protection to avoid the disturbances’ presence or to mitigate their effects on the power system. Disturbances generators are used to analyse the behavior of electrical and electronic equipments affected by disturbances. The analysis of those failures allows the development of appropriated protection equipments. In this paper, the development of a disturbances generator based on power converters is presented. The disturbance generator developed is able to generate some symmetrical disturbances, such as: voltage sags, voltage swells and harmonic distortion. The control strategy used in the disturbance generator is based on discrete and repetitive control. The steps of the design of the control and of the filter used for reducing harmonic in the output, are detailed in the text. Are presented the obtained results on computational simulations and the obtained results on laboratory tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation aims at showing the importance of the Nietzsche s and Spinoza s philosophy in Deleuze thought, about body, force, and potency concepts. The search starts from Deleuze texts around two authors of his inspiration, reaching understand in the plan of immanence of the relationship between concepts and the way life as ethics and political affirmation. The first goal is the concept of rhizome; propose by Deleuze in what manner to walk the ways traced by philosophers and at the same time to create self ways. The second chapter examines the body in Nietzsche as force s relations. Find to show the genesis of the force in its determination as relative quantity strong or weak, and as absolute quality active or reactive; and for other side the genesis of the force from two poles of the will to power affirmation or negation, examining the consequences for life and thought. In the third chapter explained the definitions of body in Spinoza. The body, in Spinoza, defines itself complex relation of movement and repose, velocity and slowness and by it s to affect and be affecter s power. Find to show understanding the mediums for to amplify the power of to exist or the potency of to act, in what manner ethics of to live. The fourth chapter makes one parallel between the war and the thought in the constitution of socials body and collectives agenciamientos, for understand in the fifth chapter the body as war s machine of the thought, from the relationship between nomad way life and war s machine showed in Tractate of Nomadologia. Wait like this to show the importance of the ethics and political thought than affirm the existence in the world through active force from that body s power.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper makes a comparative study of two Soft Single Switched Quadratic Boost Converters (SSS1 and SSS2) focused on Maximum Power Point Tracking (MPPT) of a PV array using Perturb and Observe (P&O) algorithm. The proposed converters maintain the static gain characteristics and dynamics of the original converter with the advantage of considerably reducing the switching losses and Electromagnetic Interference (EMI). It is displayed the input voltage Quadratic Boost converter modeling; qualitative and quantitative analysis of soft switching converters, defining the operation principles, main waveforms, time intervals and the state variables in each operation steps, phase planes of resonant elements, static voltage gain expressions, analysis of voltage and current efforts in semiconductors and the operational curves at 200 W to 800 W. There are presented project of PI, PID and PID + Notch compensators for MPPT closed-loop system and resonant elements design. In order to analyze the operation of a complete photovoltaic system connected to the grid, it was chosen to simulate a three-phase inverter using the P-Q control theory of three-phase instantaneous power. Finally, the simulation results and experimental with the necessary comparative analysis of the proposed converters will be presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: A arterite de células gigantes (ACG), de etiologia desconhecida, é a vasculite sistémica mais comum nos adultos e pode ter uma ampla variedade de apresentações clínicas. Atinge mais frequentemente os ramos extracranianos da artéria carótida mas, em 10-15% dos casos, pode ocorrer o envolvimento das artérias subclávia, axilar e braquial. Caso clínico: Tratava-se de uma doente do sexo feminino, de 80 anos, com antecedentes de HTA e doença cerebrovascular. Foi observada no serviço de urgência por arrefecimento e dor em repouso nos membros superiores, com evidências de cianose digital distal bilateral. As queixas tinham tido início 2 meses antes e agravamento progressivo desde então. Realizou um angio-TC que mostrou a existência de oclusão de ambas as artérias axilares/braquiais proximais e imagens sugestivas de vasculite ao nível de ambas as artérias subclávias, aorta e artérias femorais comuns. Foi medicada com corticoterapia; contudo, por não apresentar melhoria significativa após 5 dias, optou-se por realizar um bypass carotídeo-umeral bilateral. Após a cirurgia, ocorreu resolução completa das queixas e a doente apresentava pulso radial palpável bilateralmente. Seis meses após a cirurgia, a doente encontrava-se assintomática e os bypasses permeáveis. Conclusão: O presente trabalho pretende expor o caso de uma doente com o diagnóstico inaugural e ACG,que se apresentou com isquemia crítica bilateral e simultânea. Este quadro clínico exigiu a realização de um procedimento de revascularização raro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents the development and modification of techniques to reduce the effects of load variation and mains frequency deviation in repetitive controllers applied to active power filters. To minimize the effects of aperiodic signals resulting from the connection or disconnection of non-linear loads is developed a technique which recognizes linear and nonlinear loads, and operates to reset the controller only when the error due to the transition of considerable value, and the transition is from non-linear to linear load. An algorithm to adapt the gain of the repetitive controller, based on a sigmoid function adaptation, in order to minimize the effects caused by random noise in the measurement system is also used. This work also analyzes the effects of frequency variation and presents the main methods to cope with this situation. Some solutions are the change in the number of samples per period and the variation of the sampling rate. The first has the advantage of using linear design techniques and results in a time invariant system. The second method changes the sampling frequency and leads to a time variant system that demands a difficult analysis of stability. The proposed algorithms were tested using the methods of truncation of the number of samples and the method of changing the sampling rate of the system to compensate possible frequency variations of the grid. Experimental results are presented to validate the proposal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La terapia subacuática se considera una alternativa innovadora para los pacientes con algún déficit en la realización de los movimientos que se ven afectados por algún padecimiento, razón por la cual es necesario de alguna manera aumentar su fuerza que es en si la causa de la debilidad muscular. Es por ello que los ejercicios dentro del agua proporcionan un mayor rendimiento debido a las propiedades físicas de ella, ya que se logra realizar los movimientos con un grado mínimo de dificultad. Es por esta razón que se considera importante la investigación mediante el cual se beneficiaron; los pacientes ya que tuvieron la oportunidad de lograr una máxima funcionabilidad con el aumento de la fuerza muscular y mejorar su calidad de vida. Así como la institución ya que estará aportando una nueva forma de tratamiento. A los profesionales en Fisioterapia y Terapia Ocupacional el estudio permitirá conocer y aplicar una nueva modalidad de tratamiento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of non-linear loads at a point in the distribution system may deform voltage waveform due to the consumption of non-sinusoidal currents. The use of active power filters allows significant reduction of the harmonic content in the supply current. However, the processing of digital control structures for these filters may require high performance hardware, particularly for reference currents calculation. This work describes the development of hardware structures with high processing capability for application in active power filters. In this sense, it considers an architecture that allows parallel processing using programmable logic devices. The developed structure uses a hybrid model using a DSP and an FPGA. The DSP is used for the acquisition of current and voltage signals, calculation of fundamental current related controllers and PWM generation. The FPGA is used for intensive signal processing, such as the harmonic compensators. In this way, from the experimental analysis, significant reductions of the processing time are achieved when compared to traditional approaches using only DSP. The experimental results validate the designed structure and these results are compared with other ones from architectures reported in the literature.