967 resultados para Papillary Muscles


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Posteroanterior stiffness of the lumbar spine is influenced by factors, including trunk muscle activity and intra-abdominal pressure (IAP). Because these factors vary with breathing, this study investigated whether stiffness is modulated in a cyclical manner with respiration. A further aim was to investigate the relationship between stiffness and IAP or abdominal and paraspinal muscle activity. Stiffness was measured from force-displacement responses of a posteroanterior force applied over the spinous process of L-2 and L-4. Recordings were made of IAP and electromyographic activity from L-4/L-2 erector spinae, abdominal muscles, and chest wall. Stiffness was measured with the lung volume held at the extremes of tidal volume and at greater and lesser volumes. Stiffness at L-4 and L-2 increased above base-level values at functional residual capacity (L-2 14.9 N/mm and L-4 15.3 N/mm) with both inspiratory and expiratory efforts. The increase was related to the respiratory effort and was greatest during maximum expiration (L-2 24.9 N/mm and L-4 23.9 N/mm). The results indicate that changes in trunk muscle activity and IAP with respiratory efforts modulate spinal stiffness. In addition, the diaphragm may augment spinal stiffness via attachment of its crural fibers to the lumbar vertebrae.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To investigate the ability of ultrasonography to estimate musactivity, we measured architectural parameters (pennation angles, fascicle lengths, and muscle thickness) of several human muscles (tibialis anterior, biceps brachii, brachialis, transversus abdominis, obliquus internus abdominis, and obliquus externus abdominis) during isometric contractions of from 0 to 100% maximal voluntary contraction (MVC). Concurrently, electromyographic (EMG) activity was measured with surface (tibialis anterior only) or fine-wire electrodes. Most architectural parameters changed markedly with contractions up to 30% MVC but changed little at higher levels of contraction. Thus, ultrasound imaging can be used to detect low levels of muscle activity but cannot discriminate between moderate and strong contractions. Ultrasound measures could reliably detect changes in EMG of as little as 4% MVC (biceps muscle thickness), 5% MVC (brachialis muscle thickness), or 9% MVC (tibialis anterior pennation angle). They were generally less sensitive to changes in abdominal muscle activity, but it was possible to reliably detect contractions of 12% MVC in transversus abdominis (muscle length) and 22% MVC in obliquus internus (muscle thickness). Obliquus externus abdominis thickness did not change consistently with muscle contraction, so ultrasound measures of thickness cannot be used to detect activity of this muscle. Ultrasound imaging can thus provide a non-invasive method of detecting isometric muscle contractions of certain individual muscles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: For treatment of various knee disorders, muscles are trained in open or closed kinetic chain tasks. Coordination between the heads of the quadriceps muscle is important for stability and optimal joint loading for both the tibiofemoral and the patellofemoral joint. The aim of this study was to examine whether the quadriceps femoris muscles are activated differently in open versus closed kinetic chain tasks. Methods: Ten healthy men and women (mean age 28.5 +/- 0.7) extended the knees isometrically in open and closed kinetic chain tasks in a reaction time paradigm using moderate force. Surface electromyography (EMG) recordings were made from four different parts of the quadriceps muscle. The onset and amplitude of EMG and force data were measured. Results: In closed chain knee extension, the onset of EMG activity of the four different muscle portions of the quadriceps was more simultaneous than in the open chain. In open chain, rectus femoris (RF) had the earliest EMG onset while vastus medialis obliquus was activated last (7 +/- 13 ms after RF EMG onset) and with smaller amplitude (40 +/- 30% of maximal voluntary contraction (MVC)) than in closed chain (46 +/- 43% MVC). Conclusions: Exercise in closed kinetic chain promotes more balanced initial quadriceps activation than does exercise in open kinetic chain. This may be of importance in designing training programs aimed toward control of the patellofemoral joint.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Actively warming patients during surgery is considered the best method of preventing inadvertent hypothermia due to multiple causes: anaesthetic depression of the hypothalamic thermoregulatory centre, cutaneous vasodilatation, reduction of heat production by skeletal muscles, cold intravenous fluid administration and heat loss from opened body cavities. To compare the effects of active peripheral skin warming and trunk warming on body temperature during surgery, 15 dogs undergoing ovariohysterectomy were studied using a prospective randomised trial design. Dogs were randomised into two groups: one group was warmed by compress leg pads (n=7) on limbs and the other group by a circulating warm water mattress (n=8), applied to the trunk. The rectal, oesophageal and room temperatures and relative humidity were measured. The results showed that the compress leg pads (active peripheral warming) were significantly (P

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated how the relative direction of limb movements in external space (iso- and non-isodirectionality), muscular constraints (the relative timing of homologous muscle activation) and the egocentric frame of reference (moving simultaneously toward/away the longitudinal axis of the body) contribute to the stability of coordinated movements. In the first experiment, we attempted to determine the respective stability of isodirectional and non-isodirectional movements in between-persons coordination. In a second experiment, we determined the effect of the relative direction in external space, and of muscular constraints, on pattern stability during a within-person bimanual coordination task. In the third experiment we dissociated the effects on pattern stability of the muscular constraints, relative direction and egocentric frame of reference. The results showed that (1) simultaneous activation of homologous muscles resulted in more stable performance than simultaneous activation of non-homologous muscles during within-subject coordination, and that (2) isodirectional movements were more stable than non-isodirectional movements during between-persons coordination, confirming the role of the relative direction of the moving limbs in the stability of bimanual coordination. Moreover, the egocentric constraint was to some extent found distinguishable from the effect of the relative direction of the moving limbs in external space, and from the effect of the relative timing of muscle activation. In summary, the present study showed that relative direction of the moving limbs in external space and muscular constraints may interact either to stabilize or destabilize coordination patterns. (C) 2003 Published by Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of the present study was to investigate the between-days reliability of electromyographic (EMG) measurement of 6 bilateral trunk muscles and also the torque output in 3 planes during isometric right and left axial rotation at different exertion levels. Methods: Ten healthy subjects performed isometric right and left axial rotation at 100, 70, 50 and 30% maximum voluntary contractions in two testing sessions at least 7 days apart. EMG amplitude and frequency analyses of the recorded surface EMG signals were performed for rectus abdominis, external oblique, internal oblique, latissimus dorsi, iliocostalis lumborum and multifidus bilaterally. The primary torque in the transverse plane and the coupling torques in sagittal and coronal planes were measured. Results: For both EMG amplitude and frequency values, good (intraclass correlation coefficient, ICC = 0.75-0.89) to excellent (ICC greater than or equal to 0.90) reliability was found in the 6 trunk muscles at different exertion levels during axial rotation. The reliability of both maximal isometric axial rotation torque and coupling torques in sagittal and coronal planes were found to be excellent (ICC greater than or equal to 0.93). Conclusions: Good to excellent reliability of EMG measures of trunk muscles and torque measurements during isometric axial rotation was demonstrated. This provides further confidence of using EMG and triaxial torque assessment as outcome measures in rehabilitation and in the evaluation of the human performance in the work place. (C) 2003 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background The reduction of exercise capacity because of fatigue and dyspnea in patients with heart failure can be improved with exercise training. We sought to examine the mechanisms of exercise training, as an adjunctive treatment strategy for patients with heart failure. Methods a reviewed the published data on the possible mechanisms of effect of exercise training in heart failure. Results Symptoms of heart failure may be explained on the basis of abnormal skeletal muscle perfusion and structure and endothelial function. Exercise training has been shown to engender changes in muscle structure and biochemistry and vascular function, although effects on cardiac function have not been detected uniformly and may require longer training periods. Conclusions A suitable, long-term program of exercise training may reverse unfavorable interactions among the heart, vessels, and skeletal muscles. These improvements may be preserved with an ongoing maintenance program.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Determinar as alterações de atividade da enzima conversora de angiotensina (ECA) no coração com infarto do miocárdio (IM) e comparar os efeitos do captopril e losartan em parâmetros morfológicos e funcionais de ratos com IM. Métodos: O IM foi produzido em ratos Wistar por ligadura de ramos da artéria coronária esquerda. Os controles (Con) foram submetidos a uma cirurgia fictícia. Animais com IM e Con foram tratados com captopril (30mg/kg/dia) ou losartan (15mg/kg/dia) e estudados 30 dias após, determinando-se a atividade da ECA nos ventrículos direito (VD) e esquerdo (VE), as alterações hemodinâmicas e as concentrações de hidroxiprolina (OH-Pro) e proteína total no VD e VE. Resultados: A atividade da ECA aumentou no VD (+25%) e VE (+70%) após IM. A maior atividade foi observada na cicatriz fibrótica, onde atingiu cerca de 4,5 vezes a do músculo do VE que sobreviveu ao IM (420±68 vs 94±8nmoles/g/min; P<0,01). O IM determinou aumento da pressão diastólica final e hipertrofia do VD e VE. Captopril e losartan foram igualmente eficazes em atenuar a hipertrofia e o aumento da pré-carga. O captopril também atenuou o aumento de OH-Pro no VD e VE após IM. O IM reduziu a concentração de proteína principalmente no músculo de VE, efeito esse acentuado pelo captopril. Conclusão: A grande atividade da ECA na cicatriz deve produzir altas concentrações de angiotensina II (AII) no sangue que drena da cicatriz. Os efeitos dos inibidores da ECA seriam decorrentes, principalmente, da redução de geração local de AII, e não de aumento de cininas, uma vez que captopril e losartan exerceram efeitos similares no remodelamento pós-infarto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O Acidente Vascular Cerebral (AVC) é uma das principais causas de prejuízos ao sistema neuromuscular. Dispositivos Robóticos vêm sendo amplamente desenvolvidos e estudados com a finalidade de serem utilizados na assistência à marcha e para o treinamento da marcha durante a reabilitação. O objetivo deste trabalho é avaliar a marcha assistida pelo AROW (Assistive Robotic Walker) em indivíduos hemiparéticos pós-AVC, através da análise de sinais de acelerometria e sinais mioelétricos de superfície (sEMG) provenientes dos músculos vasto medial (VM), bíceps femoral (BF), tibial anterior (TA) e gastrocnêmio medial (GM), e também utilizando os métodos de avaliação GAS (Goal Attainment Scaling) e SUS (System Usability Scale). Nove indivíduos hemiparéticos participaram dos testes. A velocidade da marcha foi reduzida com o uso do AROW e, consequentemente, houve algumas alterações na duração das fases da marcha, por exemplo, uma maior duração da fase de apoio (p = 0,0174). O padrão de ativação muscular para o grupo analisado não apresentou diferença estatisticamente significativa (início da ativação VM: p= 0,4999; término da ativação VM: p= 0,5647; início BF: p= 0,1186; término BF: p= 0,7823; início TA: p= 0,5833; término TA: p= 0,8393; início GM: p= 0,6077; término GM: p= 0,1429). Entretanto, avaliando o padrão de ativação muscular individualmente, podem-se notar algumas alterações benéficas, por exemplo, redução da coativação dos músculos tibial anterior e gastrocnêmio medial. Os resultados das avaliações através do GAS (54,8) e SUS (81,4) sobre o uso do AROW mostraram boa aceitação pelos usuários, e os objetivos esperados durante o uso do andador foram atingidos. A adaptação rápida, facilidade de utilização e sentimento de segurança ao usar o dispositivo são pontos positivos obtidos com o uso do AROW.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Poly(vinylidene fluoride-trifluoethylene) electrospun membranes were obtained from a blend of dimethylformamide (DMF) and methylethylketone (MEK) solvents. The inclusion of the MEK to the solvent system promotes a faster solvent evaporation allowing complete polymer crystallization during the jet travelling between the tip and the grounded collector. Several processing parameters were systematically changed to study their influence on fiber dimensions. Applied voltage and inner needle diameter do not have large influence on the electrospun fiber average diameter but in the fiber diameter distribution. On the other hand, the increase of the distance between the needle tip to collector results in fibers with larger average diameter. Independently on the processing conditions, all mats are produced in the electroactive phase of the polymer. Further, MC-3T3-E1cell adhesion was not inhibited by the fiber mats preparation, indicating their potential use for biomedical applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is shown that electrospun poly(vynilidene fluoride) nanofibers are fully poled right after preparation and show b-phase contents of 70%, therefore being able to be implemented into electroactive devices without further processing steps. Further,the local piezoelectric properties of individual electrospun fibers have been studied by piezoresponse force microscopy. Piezoelectric response, polarization switching, and nanoscale patterning of the fibers have been demonstrated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electroactivematerials can be taken to advantage for the development of sensors and actuators as well as for novel tissue engineering strategies. Composites based on poly(vinylidenefluoride),PVDF,have been evaluated with respect to their biological response. Cell viability and proliferation were performed in vitro both with Mesenchymal Stem Cells differentiated to osteoblasts and Human Fibroblast Foreskin 1. In vivo tests were also performed using 6-week-old C57Bl/6 mice. It was concluded that zeolite and clay composites are biocompatible materials promoting cell response and not showing in vivo pro-inflammatory effects which renders both of them attractive for biological applications and tissue engineering, opening interesting perspectives to development of scaffolds from these composites. Ferrite and silver nanoparticle composites decrease osteoblast cell viability and carbon nanotubes decrease fibroblast viability. Further, carbon nanotube composites result in a significant increase in local vascularization accompanied an increase of inflammatory markers after implantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thermal and hydrolytic degradation of electrospun gelatin membranes cross-linked with glutaraldehyde in vapor phase has been studied. In vitro degradation of gelatin membranes was evaluated in phosphate buffer saline solution at 37 ºC. After 15 days under these conditions, a weight loss of 68 % was observed, attributed to solvation and depolymerization of the main polymeric chains. Thermal degradation kinetics of the gelatin raw material and as-spun electrospun membranes showed that the electrospinning processing conditions do not influence polymer degradation. However, for cross-linked samples a decrease in the activation energy was observed, associated with the effect of glutaraldehyde cross-linking reaction in the inter- and intra-molecular hydrogen bonds of the protein. It is also shown that the electrospinning process does not affect the formation of the helical structure of gelatin chains.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Poly(hydroxybutyrate) (PHB) obtained from sugar cane was dissolved in a blend of chloroform and dimethylformamide (DMF) and electrospun at 40 ºC. By adding DMF to the solution, the electrospinning process for the PHB polymer becomes more stable, allowing complete polymer crystallization during the jet travelling between the tip and the grounded collector. The influence of processing parameters on fiber size and distribution was systematically studied. It was observed that an increase of tip inner diameter promotes a decrease of the fiber average size and a broader distribution. On the other hand, an increase of the electric field and flow rate produces an increase of fiber diameter until a maximum of ~2.0 m, but for electric fields higher than 1.5 kV.cm-1, a decrease of the fiber diameter was observed. Polymer crystalline phase seems to be independent of the processing conditions and a crystallinity degree of 53 % was found. Moreover, thermal degradation of the as-spun membrane occurs in single step degradation with activation energy of 91 kJ/mol. Furthermore, MC-3T3-E1 cell adhesion was not inhibited by the fiber mats preparation, indicating their potential use for biomedical applications.