991 resultados para Mini-implante


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Twenty-nine HCV-infected patients were treated with pegylated interferon alpha. Diagnosis was based on serum HCV RNA-PCR positive results and liver biopsy. All patients had elevated serum levels of alanine aminotransferase at the time of the study, but liver disease was compensated. Patients were evaluated at baseline treatment and after 4 and 12 weeks of antiviral treatment with the Medical Outcomes Study 36-item Short-Form Health Survey. The Mini-International Neuropsychiatric Interview was used to exclude previous or current psychiatric diagnoses. Both patients and psychiatrists were blind to the HCV RNA status, and serum HCV RNA test results only became available after the visit at week 12. After antiviral treatment, 16 patients (55.2%) were classified as nonresponders and 13 (44.8%) were classified as responders. When compared to nonresponders, responders had a greater improvement in the HRQOL scores for the mental health domain (P<.019). Differences in other domains were not significant. The present study confirms that active viral infection is one possible reason for the poor Health-Related Quality of Life in this population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: To present the prevalence of cognitive and functional impairment (CFI) in community-dwelling elderly subjects from the city of Sao Paulo. Methods: The population was aged 60 years and older (n = 1,563; 68.7% women and 31.3% men) and lived in different socioeconomic areas. The following instruments were administered to the elderly: the Mini Mental State Examination and the Fuld Object Memory Evaluation. The Informant Questionnaire on Cognitive Decline in the Elderly and the Bayer-Activities of Daily Living scale were administered to an informant. Results: The prevalence of CFI (n = 250) was 16% (95% confidence interval, CI: 14.2-17.8%) or 15.8% (95% CI: 13.8-17.8%). In regression models, the increase in the odds ratio (OR) of CFI was associated with age, for elderly individuals aged 75 years or older, illiterates or with 1-4 years of schooling, and with a history of stroke and diabetes mellitus. On the other hand, for subjects with a tumor history, the OR of CFI was significantly reduced. Conclusion: CFI was high and increased at older ages and in subjects with low education. Potentially changeable factors were identified (stroke and diabetes), and the possible `protective effect` of tumor/cancer against CFI should be further investigated by longitudinal studies. Copyright (C) 2007 S. Karger AG, Basel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although several stage-specific genes have been identified in Leishmania, the molecular mechanisms governing developmental gene regulation in this organism are still not well understood. We have previously reported an attenuation of virulence in Leishmania major and L braziliensis carrying extra-copies of the spliced leader RNA gene. Here, we surveyed the major differences in proteome and transcript expression profiles between the spliced leader RNA overexpressor and control lines using two-dimensional gel electrophoresis and differential display reverse transcription PCR, respectively. Thirty-nine genes related to stress response, cytoskeleton, proteolysis, cell cycle control and proliferation, energy generation, gene transcription, RNA processing and post-transcriptional regulation have abnormal patterns of expression in the spliced leader RNA overexpressor line. The evaluation of proteolytic pathways in the mutant revealed a selective increase of cysteine protease activity and an exacerbated ubiquitin-labeled protein population. Polysome profile analysis and measurement of cellular protein aggregates showed that protein translation in the spliced leader RNA overexpressor line is increased when compared to the control line. We found that L major promastigotes maintain homeostasis in culture when challenged with a metabolic imbalance generated by spliced leader RNA surplus through modulation of intracellular proteolysis. However, this might interfere with a fine-tuned gene expression control necessary for the amastigote multiplication in the mammalian host. (c) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The prevention and treatment of diseases related to changes in body composition require accurate methods for the measurement of body composition. However, few studies have dealt specifically with the assessment of body composition of undernourished older subjects by different methodologies. To assess the body composition of undernourished older subjects by two different methods, dual energy x-ray absorptiometry (DXA) and bioelectric impedance (BIA), and to compare results with those of an eutrophic group. The study model was cross-sectional; the study was performed at the University Hospital of the School of Medicine of Ribeiro Preto, University of So Paulo, Brazil. Forty-one male volunteers aged 62 to 91 years. The groups were selected on the basis of anamnesis, physical examination and nutritional assessment according to the Mini Nutritional Assessment (MNA) score. Body composition was assessed by DXA and BIA. Body weight, arm and calf circumference, body mass index (BMI), fat free mass (FFM) and fat mass (FM) were significantly lower in the undernourished group as compared to the eutrophic group. There were no significant differences between FFM and FM mean values determined by DXA and BIA in both groups, but the agreement between methods in the undernourished group was less strong. Our results suggest caution when BIA is to be applied in studies including undernourished older subjects. This study does not support BIA as an accurate method for the individual assessment of body composition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. To analyze the psychometric properties of the Brazilian Portuguese version of the Beck Anxiety Inventory (BAI) in terms of its internal consistency, scores distribution, concurrent and discriminant validity, and factorial analysis in a sample of university students and social anxiety disorder (SAD) cases and non-cases. Methods. A sample of Brazilian university students from the general population (N = 2314) and a sample of university students identified as cases (N = 88) and non-cases (N = 90) of SAD were assessed, using as a parameter the Structured Clinical Interview for the DSM-IV. The different instruments were completed individually in the presence of an experienced rater. Results. The BAI showed adequate internal consistency (0.88-0.92) and discriminant validity, with 0.74 sensitivity and 0.71 specificity for a cut-off score of 10. The factorial analysis suggested a three-factor solution to be the most adequate. Conclusions. The version of the BAI studied is quite adequate to be used in the context of Brazilian university students, identifying the presence of anxiety indicators. However, its usefulness to screen for SAD seems limited.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Generalized Social Anxiety Disorder (SAD) is one of the most common anxiety conditions with impairment in social life. Cannabidiol (CBD), one major non-psychotomimetic compound of the cannabis sativa plant, has shown anxiolytic effects both in humans and in animals. This preliminary study aimed to compare the effects of a simulation public speaking test (SPST) on healthy control (HC) patients and treatment-naive SAD patients who received a single dose of CBD or placebo. A total of 24 never-treated patients with SAD were allocated to receive either CBD (600 mg; n = 12) or placebo (placebo; n = 12) in a double-blind randomized design 1 h and a half before the test. The same number of HC (n = 12) performed the SPST without receiving any medication. Each volunteer participated in only one experimental session in a double-blind procedure. Subjective ratings on the Visual Analogue Mood Scale (VAMS) and Negative Self-Statement scale (SSPS-N) and physiological measures (blood pressure, heart rate, and skin conductance) were measured at six different time points during the SPST. The results were submitted to a repeated-measures analysis of variance. Pretreatment with CBD significantly reduced anxiety, cognitive impairment and discomfort in their speech performance, and significantly decreased alert in their anticipatory speech. The placebo group presented higher anxiety, cognitive impairment, discomfort, and alert levels when compared with the control group as assessed with the VAMS. The SSPS-N scores evidenced significant increases during the testing of placebo group that was almost abolished in the CBD group. No significant differences were observed between CBD and HC in SSPS-N scores or in the cognitive impairment, discomfort, and alert factors of VAMS. The increase in anxiety induced by the SPST on subjects with SAD was reduced with the use of CBD, resulting in a similar response as the HC. Neuropsychopharmacology (2011) 36, 1219-1226; doi: 10.1038/npp.2011.6; published online 9 February 2011

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of the study was to study the psychometric properties of the Social Phobia Inventory (SPIN) in its version for the context of Brazilian adults. Methods: A sample of Brazilian university students from the general population (n = 2314) and a sample of university students identified as cases (n = 88) and noncases (n = 90) of social phobia were assessed, using as a parameter the Structured Clinical Interview for the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition. The different instruments were applied individually in the presence of a rater. Results: The SPIN showed adequate internal consistency (.63-.90) and concurrent validity with different instruments of auto- and hetero-evaluation of social phobia. Discriminative validity showed 0.84 to 0.86 sensitivity and 0.84 to 0.87 specificity for cutoff notes between 19 and 21. Factorial analysis showed the presence of a variable number of factors as a function of the different samples. Conclusions: The version of the SPIN studied is quite adequate for use in the context of Brazilian university students, favoring the screening of social phobia. However, further studies using more diverse samples are needed. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Social anxiety disorder (SAD) is a highly prevalent condition even though its recognition and diagnosis are underestimated by both patients and clinicians. In view of the importance of assessment scales for systematic diagnosis in psychiatry, the objective of this investigation was to present studies of validation for the Brazilian population of three instruments for the assessment of different aspects of SAD. The following psychometric studies were carried out: a) discriminative validity of the Mini Social Phobia Inventory (Mini-SPIN-MS), a reduced instrument for the screening of SAD; b) reliability and discriminative validity of the Brief Social Phobia Scale (BSPS), a hetero-applied instrument for the assessment of different aspects of SAD, and c) discriminative validity of the items and subscales of the Self-Statements during Public Speaking Scale (SSPS), an instrument for the assessment of cognitive aspects related to public speaking. All instruments showed excellent psychometric qualities, especially indicators of discrimination between persons with and without SAD, with diagnostic confirmation by the Structured Clinical Interview for DSM-IV (SCID-IV). It was concluded that this set of instruments, with specificity regarding their objectives, could be of great clinical usefulness, especially for the Brazilian population that, until recently, had no such resources for the measurement and assessment of the different aspects of SAD. New multicenter and intercultural studies may provide further information about cultural influences on SAD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: It has been suggested that individuals with social anxiety disorder (SAD) are exaggeratedly concerned about approval and disapproval by others. Therefore, we assessed the recognition of facial expressions by individuals with SAD, in an attempt to overcome the limitations of previous studies. Methods: The sample was formed by 231 individuals (78 SAD patients and 153 healthy controls). All individuals were treatment naive, aged 18-30 years and with similar socioeconomic level. Participants judged which emotion (happiness, sadness, disgust, anger, fear, and surprise) was presented in the facial expression of stimuli displayed on a computer screen. The stimuli were manipulated in order to depict different emotional intensities, with the initial image being a neutral face (0%) and, as the individual moved on across images, the expressions increased their emotional intensity until reaching the total emotion (100%). The time, accuracy, and intensity necessary to perform judgments were evaluated. Results: The groups did not show statistically significant differences in respect to the number of correct judgments or to the time necessary to respond. However, women with SAD required less emotional intensity to recognize faces displaying fear (p = 0.002), sadness (p = 0.033) and happiness (p = 0.002), with no significant differences for the other emotions or men with SAD. Conclusions: The findings suggest that women with SAD are hypersensitive to threat-related and approval-related social cues. Future studies investigating the neural basis of the impaired processing of facial emotion in SAD using functional neuroimaging would be desirable and opportune. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To perform a psychometric analysis of the Brazilian version of the Brief Social Phobia Scale (BSPS). Materials and methods: Hundred and seventy-eight university students of both genders aged on average 21.2 years and identified as Social Anxiety Disorder (SAD) cases and non-cases was studied, with the structured clinical interview for DSM-IV being used as a parameter. The different instruments were applied in an individual manner in the presence of a rater and of an observer. Results: The BSPS showed adequate internal consistency (0.48-0.88) and concurrent and divergent validity with the Beck Anxiety Inventory (BAI) (0.21-0.62), Social Phobia Inventory (0.24-0.82) and Self Statements During Public Speaking Scale (SSPS) (0.23-0.31). Discriminative validity revealed a sensitivity of 0.88-0.90 and a specificity of 0.81(0.83 for cut-off notes of 18/19. Factorial analysis demonstrated the presence of six factors that jointly explained 71.79% of data variance. Construct validity indicated some limits of the scale regarding the diagnosis of SAD. Inter-rater reliability was strong (0.86-1.00, p < 0.001). Conclusions: The BSPS is adequate for use with university students, although further studies in different cultures, samples and contexts are still necessary. (C) 2009 Elsevier Masson SAS. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Benign Paroxysmal Positional Vertigo is the most common peripheral vestibular disorder, especially in the elderly and presents as the predominant etiology in this population of the degeneration of the utricular macula. Aim: To compare the effectiveness of the approaches after Epley maneuver. Study Design: longitudinal cohort. Materials and Methods: The study included 53 volunteers with Benign Paroxysmal Positional Vertigo of the posterior semicircular canal, divided into Group 1, who underwent Epley maneuver associated with the use of neck collar and post-maneuver instructions, Group 2 underwent the Epley maneuver without the use cervical collar and/or post-maneuver restrictions, and Group 3 underwent the Epley maneuver associated with the use of a mini vibrator, without the use of neck collar and/or post-maneuver restrictions. Results: In the three groups, the number of Epley maneuvers ranged from one to three. We employed the Brazilian Dizziness Handicap Inventory - pre- and post-treatment and observed a statistically significant difference on most scores pre- and post-treatment for both groups. Conclusion: Regardless of the post Epley maneuver treatment selected for the treatment of Benign Paroxysmal Positional Vertigo, it was effective when comparing the Brazilian Dizziness Handicap Inventory pre- and post-treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this in vitro study was to compare the bond strength between fiber post and laser-treated root canals. Forty single-rooted bovine teeth were endodontically treated and randomly divided into four groups of equal size according to the root canal treatment: group 1 conventional treatment (without laser irradiation); group 2 Nd:YAG laser (1.5 W, 10 Hz, 100 mJ); group 3 Er,Cr:YSGG laser (0.75 W, 20 Hz); and group 4 Nd:YAG + Er,Cr:YSGG lasers. The fiber posts were cemented with an adhesive system + resin cement, in accordance with the manufacturer`s instructions. A mini acrylic pipe was fixed on the coronal section of the post using a light-polymerized resin. Specimens were mounted on an acrylic pipe with a self-polymerized resin. Retention forces were determined using a universal testing machine (0.5 mm/min). Data were analyzed using one-way ANOVA and Tukey tests (p < 0.05). The post retention force in group 2 was found to be lower than that in the other experimental groups. Fractures were observed at the interface between the dentin and the resin in all groups. High-intensity lasers can be used in conventional endodontic treatment; however, root canal surface irradiation using the Nd:YAG laser was shown to negatively affect the post retention force.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereo lithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. Materials and Methods: Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. Results: The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. Conclusions: The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:860-865

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The aim of this study was to compare the influence of preflaring on the accuracy of 4 electronic apex locators (EALs): Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex Locator, and Apex DSP. Methods: Forty extracted teeth were preflared by using S1 and SX ProTaper instruments. The working length was established by reducing 1 mm from the total length (TL). The ability of the EALs to detect precise (-1 mm from TL) and acceptable (-1+/-0.5 mm from TL) measurements in unflared and preflared canals was determined. Results: The precise and acceptable (P/A) readings in unflared canals for Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex and Apex DSP were 50%/97.5%, 47.5%/95%, 50%/97.5%, and 45%/67.5%, respectively. For preflared canals, the readings were 75%/97.5%, 55%/95%, 75%/97.5%, and 60%/87.5%, respectively. For precise criteria, the preflared procedure increased the percentage of accurate electronic readings for the Root ZX and the Mini Apex Locator (P < .05). For acceptable criteria, no differences were found among Root ZX, Elements Diagnostic Unit and Apex Locator, and Mini Apex Locator (P > .05). Fisher test indicated the lower accuracy for Apex DSP (P < .05). Conclusions: The Root ZX and the Mini Apex Locator devices increased significantly the precision to determine the real working length after the preflaring procedure. All the EALs showed an acceptable determination of the working length between the ranges of+/-0.5mm except for the Apex DSP device, which had the lowest accuracy. (J Endod 2009;35:1300-1302)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Mini-implants are placed in restricted sites, requiring an accurate surgical technique. However, no systematic study has quantified technique accuracy to reliably predict the surgical risks. Therefore, a graduated 3-dimensional radiographic-surgical guide (G-RSG) was proposed, and its inaccuracy and risk index (RI) were estimated. Methods: The sample consisted of 6 subjects (4 male, 2 female), who used mini-implant anchorage. Ten drill-free screws (DFS) were placed by using the G-RSG. The central point of the mesiodistal septum width (SW) was the selected implant site on the presurgical radiograph. The distances between DFS and the adjacent teeth (5-DFS and 6-DFS) were measured to evaluate screw centralization and inaccuracy degree (ID). These distances were statistically compared by independent t tests, and inaccuracy was determined by the expression ID = (5-DFS-6-DFS)/2, which represents deviation of the mini-implant`s final position regarding the central point initially selected. Then SW, ID, and screw diameter (SO) were combined to estimate the surgical risk with RI expressed by RI = SO/SW-ID. Results: The 5-DFS and 6-DFS distances were not significantly different. The ID of the G-RSG was 0.17 mm. The low ID ensured a safe RI (<1) in spite of the restricted SW. Conclusions: The G-RSG accuracy allowed fine prediction of the final DFS position in the inter-radicular septum, with a low RI, which is a helpful tool to estimate surgical risks. (Am J Orthod Dentofacial Orthop 2009; 136: 722-35)