Predictable drill-free screw positioning with a graduated 3-dimensional radiographic-surgical guide: A preliminary report


Autoria(s): ESTELITA, Sergio; JANSON, Guilherme; CHIQUETO, Kelly; JANSON, Marcos; FREITAS, Marcos Roberto de
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

19/10/2012

19/10/2012

2009

Resumo

Introduction: Mini-implants are placed in restricted sites, requiring an accurate surgical technique. However, no systematic study has quantified technique accuracy to reliably predict the surgical risks. Therefore, a graduated 3-dimensional radiographic-surgical guide (G-RSG) was proposed, and its inaccuracy and risk index (RI) were estimated. Methods: The sample consisted of 6 subjects (4 male, 2 female), who used mini-implant anchorage. Ten drill-free screws (DFS) were placed by using the G-RSG. The central point of the mesiodistal septum width (SW) was the selected implant site on the presurgical radiograph. The distances between DFS and the adjacent teeth (5-DFS and 6-DFS) were measured to evaluate screw centralization and inaccuracy degree (ID). These distances were statistically compared by independent t tests, and inaccuracy was determined by the expression ID = (5-DFS-6-DFS)/2, which represents deviation of the mini-implant`s final position regarding the central point initially selected. Then SW, ID, and screw diameter (SO) were combined to estimate the surgical risk with RI expressed by RI = SO/SW-ID. Results: The 5-DFS and 6-DFS distances were not significantly different. The ID of the G-RSG was 0.17 mm. The low ID ensured a safe RI (<1) in spite of the restricted SW. Conclusions: The G-RSG accuracy allowed fine prediction of the final DFS position in the inter-radicular septum, with a low RI, which is a helpful tool to estimate surgical risks. (Am J Orthod Dentofacial Orthop 2009; 136: 722-35)

Identificador

AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, v.136, n.5, p.722-735, 2009

0889-5406

http://producao.usp.br/handle/BDPI/26039

10.1016/j.ajodo.2007.12.028

http://dx.doi.org/10.1016/j.ajodo.2007.12.028

Idioma(s)

eng

Publicador

MOSBY-ELSEVIER

Relação

American Journal of Orthodontics and Dentofacial Orthopedics

Direitos

restrictedAccess

Copyright MOSBY-ELSEVIER

Palavras-Chave #INTERMAXILLARY FIXATION SCREWS #MINI-IMPLANT ANCHORAGE #SELF-TAPPING SCREWS #ORTHODONTIC ANCHORAGE #TITANIUM SCREWS #CLINICAL-APPLICATIONS #CANINE RETRACTION #MAXILLARY #MINISCREWS #PLACEMENT #Dentistry, Oral Surgery & Medicine
Tipo

article

original article

publishedVersion